Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

P-MASS and P-GBA: Two new hardware developments for growing plants in space

Plant growth, and especially plant performance experiments in microgravity are limited by the currently available plant growth facilities (low light levels, inadequate nutrient delivery and atmosphere conditioning systems, insufficient science instrumentation, infrequent flight opportunities). In addition, mission durations of 10 to 14 days aboard the NSTS Space Shuttle allow for only brief periods of microgravity exposure with respect to the life cycle of a plant. Based on seed germination experiments, using the Generic BioProcessing Apparatus hardware (GBA), two new payloads have been designed specifically for plant growth. These payloads provide new opportunities for plant gravitational and space biology research and emphasize the investigation of plant performance (photosynthesis, biomass accumulations) in microgravity. The Plant-Module for Autonomous Space Support (P-MASS) was designed to utilize microgravity exposure times in excess of 30 days on the first flight of the recoverable COMET satellite (Commercial Experiment Transporter). The Plant-Generic Bioprocessing Apparatus (P-GBA), is designed for the National Space Transportation System (NSTS) Space Shuttle middeck and the SPACEHAB environment. The P-GBA is an evolution from the GBA hardware and P-MASS (plant chamber and instrumentation). The available light levels of both payloads more than double currently available capabilities.

Hoehn, Alexander↗

Attitude identification for SCOLE using two infrared cameras

An algorithm is presented that incorporates real time data from two infrared cameras and computes the attitude parameters of the Spacecraft COntrol Lab Experiment (SCOLE), a lab apparatus representing an offset feed antenna attached to the Space Shuttle by a flexible mast. The algorithm uses camera position data of three miniature light emitting diodes (LEDs), mounted on the SCOLE platform, permitting arbitrary camera placement and an on-line attitude extraction. The continuous nature of the algorithm allows identification of the placement of the two cameras with respect to some initial position of the three reference LEDs, followed by on-line six degrees of freedom attitude tracking, regardless of the attitude time history. A description is provided of the algorithm in the camera identification mode as well as the mode of target tracking. Experimental data from a reduced size SCOLE-like lab model, reflecting the performance of the camera identification and the tracking processes, are presented. Computer code for camera placement identification and SCOLE attitude tracking is listed.

Shenhar, Joram↗

Automated High-Temperature Hall-Effect Apparatus

Automated apparatus takes Hall-effect measurements of specimens of thermoelectric materials at temperatures from ambient to 1,200 K using computer control to obtain better resolution of data and more data points about three times as fast as before. Four-probe electrical-resistance measurements taken in 12 electrical and 2 magnetic orientations to characterize specimens at each temperature. Computer acquires data, and controls apparatus via three feedback loops: one for temperature, one for magnetic field, and one for electrical-potential data.

Parker, James B.↗

Small Vocabulary Recognition Using Surface Electromyography in an Acoustically Harsh Environment

This paper presents results of electromyographic-based (EMG-based) speech recognition on a small vocabulary of 15 English words. The work was motivated in part by a desire to mitigate the effects of high acoustic noise on speech intelligibility in communication systems used by first responders. Both an off-line and a real-time system were constructed. Data were collected from a single male subject wearing a fireghter's self-contained breathing apparatus. A single channel of EMG data was used, collected via surface sensors at a rate of 104 samples/s. The signal processing core consisted of an activity detector, a feature extractor, and a neural network classifier. In the off-line phase, 150 examples of each word were collected from the subject. Generalization testing, conducted using bootstrapping, produced an overall average correct classification rate on the 15 words of 74%, with a 95% confidence interval of [71%, 77%]. Once the classifier was trained, the subject used the real-time system to communicate and to control a robotic device. The real-time system was tested with the subject exposed to an ambient noise level of approximately 95 decibels.

Betts, Bradley J.↗

Improved Thermal-Diffusivity-Measuring Apparatus

Accuracy at high temperature improved. Furnace heats specimen to experimental temperature, and flash tube raises specimen temperature by small amount and for short time so diffusivity (composite property of heat capacity and conductivity) determined. Specimen mount ensures minimum heat loss during temperature-rise measurement. Measurement temperatures up to 1,000 degrees C realized with fused-quartz light pipe and up to 1,600 degrees C with sapphire light pipe.

Wood, C.↗

Vibration Studies for the CLARA Interferometer

The purpose of the CLARA experiment is to study the nature of undulator radiation emitted by single electrons circulating in the IOTA storage ring. The classical and quantum properties of the radiation are investigated by measuring its coherence length, intensity fluctuations and time correlations. The experiment took data in IOTA Run 4 (2022-2023). The key component of the apparatus is a Mach-Zehnder interferometer (MZI), in which the optical length of one of the arms can be precisely controlled. For some measurements, the fine regulation of the arm length must be smaller than the radiation wavelength. For this reason, the apparatus is particularly sensitive to mechanical vibrations. In this note, we model and measure the effect of vibrations on the performance of the MZI under various conditions. Several improvements of the setup were implemented to minimize systematic distortions of the observed interference patterns. In this report, we present a mathematical model of the effect of mechanical vibrations on observed detector and coincidence rates. We also describe the measurements that were made to estimate the magnitude and spectra of rate fluctuations and their sources in the CLARA MZI under various conditions. Finally, we estimate the magnitude of arm length fluctuations and we deduce the sensitivity to coincidence-rate variations in our apparatus.

43 PARTICLE ACCELERATORS↗

Operating characteristics of the Langley Mach 10 high Reynolds number helium tunnel

Operating characteristics of the Langley Mach 10 high Reynolds number helium tunnel are presented for stagnation pressures from 138 N/sq cm to 1655 N/sq cm. The characteristics include detailed Mach number surveys in the test section from which usable core size and regions of disturbed flow were determined, preliminary blockage test results, and maximum run time to be expected at various stagnation pressures. Important tunnel dimensions including details of the model mounting apparatus are given. Measurements show the variation in average core Mach number in the test section to be between 9.4 and 10 for the present range of test conditions. The core radius is from 23 cm to 31.5 cm, depending on stagnation pressure and axial location in the test section.

Watson, R. D.↗

Video luminescent barometry - The induction period

Video monitoring of oxygen quenching of the photoluminescence of platinum octaethylporphyrin (PtOEP) in silicone polymer resin may be used to measure pressure distribution over an airfoil. A continuous increase of the luminescence intensity of PtOEP on exposure to the exciting light is known as the induction effect. The effect of several factors on PtOEP photoluminescence and the induction effect was investigated. The experimental apparatus is described and results are presented. It was observed that the relative induction amplitude and induction time increase at higher oxygen pressure and with thicker films. These observations may be explained if the singlet oxygen produced by oxygen quenching is consumed by the polymer and is therefore unavailable for further quenching. Researchers using this method for measuring pressure distribution on airfoil surfaces should be aware of the induction effect and its implications.

Uibel, Rory H.↗

Four-Spot Time-Of-Flight Laser Anemometer For Turbomachinery

Two-color, four-spot time-of-flight laser anemometer designed for measuring flow velocity within narrow confines of small centrifugal compressor. Apparatus well suited for measuring fast (typical speeds 160 to 700 m/s), highly turbulent gas flows in turbomachinery. Other potential applications include measurement of gas flows in pipelines and in flows from explosions.

Wernet, Mark P.↗

Instrumentation for Studies of Electron Emission and Charging From Insulators

Making measurements of electron emission properties of insulators is difficult since insulators can charge either negatively or positively under charge particle bombardment. In addition, high incident energies or high fluences can result in modification of a material s conductivity, bulk and surface charge profile, structural makeup through bond breaking and defect creation, and emission properties. We discuss here some of the charging difficulties associated with making insulator-yield measurements and review the methods used in previous studies of electron emission from insulators. We present work undertaken by our group to make consistent and accurate measurements of the electron/ion yield properties for numerous thin-film and thick insulator materials using innovative instrumentation and techniques. We also summarize some of the necessary instrumentation developed for this purpose including fast response, low-noise, high-sensitivity ammeters; signal isolation and interface to standard computer data acquisition apparatus using opto-isolation, sample-and-hold, and boxcar integration techniques; computer control, automation and timing using Labview software; a multiple sample carousel; a pulsed, compact, low-energy, charge neutralization electron flood gun; and pulsed visible and UV light neutralization sources. This work is supported through funding from the NASA Space Environments and Effects Program and the NASA Graduate Research Fellowship Program.

Thomson, C. D.↗

The Hubble Space Telescope optical systems failure report

The findings of the Hubble Space Telescope Optical Systems Board of Investigation are reported. The Board was formed to determine the cause of the flaw in the telescope, how it occurred, and why it was not detected before launch. The Board conducted its investigation to include interviews with personnel involved in the fabrication and test of the telescope, review of documentation, and analysis and test of the equipment used in the fabrication of the telescope's mirrors. The investigation proved that the primary mirror was made in the wrong shape (a 0.4-wave rms wavefront error at 632.8 nm). The primary mirror was manufactured by the Perkin-Elmer Corporation (Hughes Danbury Optical Systems, Inc.). The critical optics used as a template in shaping the mirror, the reflective null corrector (RNC), consisted of two small mirrors and a lens. This unit had been preserved by the manufacturer exactly as it was during the manufacture of the mirror. When the Board measured the RNC, the lens was incorrectly spaced from the mirrors. Calculations of the effect of such displacement on the primary mirror show that the measured amount, 1.3 mm, accounts in detail for the amount and character of the observed image blurring. No verification of the reflective null corrector's dimensions was carried out by Perkin-Elmer after the original assembly. There were, however, clear indications of the problem from auxiliary optical tests made at the time. A special optical unit called an inverse null corrector, designed to mimic the reflection from a perfect primary mirror, was built and used to align the apparatus; when so used, it clearly showed the error in the reflective null corrector. A second null corrector was used to measure the vertex radius of the finished primary mirror. It, too, clearly showed the error in the primary mirror. Both indicators of error were discounted at the time as being themselves flawed. The Perkin-Elmer plan for fabricating the primary mirror placed complete reliance on the reflective null corrector as the only test to be used in both manufacturing and verifying the mirror's surface with the required precision. This methodology should have alerted NASA management to the fragility of the process and the possibility of gross error. Such errors had been seen in other telescope programs, yet no independent tests were planned, although some simple tests to protect against major error were considered and rejected. During the critical time period, there was great concern about cost and schedule, which further inhibited consideration of independent tests.

Source record↗

Test Apparatus For Oversize Ball-Bearing Models

See-through machine enables direct observation and indirect measurements at moderate speeds. Model of ball bearing, six times larger than real bearing, rotated in test machine. Transparency of walls and simulated lubricant reveal flow patterns and allow visible-light and infrared photographs to be made.

Wagner, William R.↗

Gravitational Influences on Flame Propagation Through Non-Uniform Premixed Gas Systems

We have built an apparatus for measuring flame spread rates through non-homogeneous fuel-air mixtures as a function of layer thickness and concentration. The layer thickness is adjusted by controlling the diffusion time above a fuel-saturated porous media, while the concentration is controlled by the fuel temperature. Normal gravity tests with methanol have so far explored largely the effect of temperature, as well as the effects of various aspects of the apparatus. Good agreement with previous research has been obtained. We have also demonstrated the ability of a rainbow schlieren system to quantitatively measure fuel vapor concentrations in the static case.

Miller, Fletcher J.↗

High-Temperature Switched-Reluctance Electric Motor

An eight-pole radial magnetic bearing has been modified into a switched-reluctance electric motor capable of operating at a speed as high as 8,000 rpm at a temperature as high as 1,000 F (=540 C). The motor (see figure) is an experimental prototype of starter-motor/generator units that have been proposed to be incorporated into advanced gas turbine engines and that could operate without need for lubrication or active cooling. The unique features of this motor are its electromagnet coils and, to some extent, its control software. Heretofore, there has been no commercial-off-the-shelf wire capable of satisfying all of the requirements for fabrication of electromagnet coils capable of operation at temperatures up to 1,000 F (=540 C). The issues addressed in the development of these electromagnet coils included thermal expansion, oxidation, pliability to small bend radii, micro-fretting, dielectric breakdown, tensile strength, potting compound, thermal conduction, and packing factor. For a test, the motor was supported, along with a rotor of 18 lb (.8-kg) mass, 3-in. (.7.6-cm) diameter, 21-in. (.53-cm) length, on bearings packed with high-temperature grease. The motor was located at the mid span of the rotor and wrapped with heaters. The motor stator was instrumented with thermocouples. At the time of reporting the information for this article, the motor had undergone 14 thermal cycles between room temperature and 1,000 F (.540 C) and had accumulated operating time >27.5 hours at 1,000 F (=540 C). The motor-controller hardware includes a personal computer equipped with analog-to-digital input and digital-to-analog output cards. The controller software is a C-language code that implements a switched-reluctance motor-control principle: that is, it causes the coils to be energized in a sequence timed to generate a rotating magnetic flux that creates a torque on a scalloped rotor. The controller can operate in an open- or closed-loop mode. In addition, the software has been modified to enable the simultaneous operation of the prototype motor or another, similar apparatus as both a motor and a magnetic bearing. Combined bearing/motor operation has been demonstrated at room temperature but had not yet been demonstrated at high temperature at the time of reporting the information for this article.

Montague, Gerald↗

Photoinduced correlations in stochastic dynamics of a solid-state ionic conductor

Photoexcitation by ultrashort laser pulses plays a crucial role in controlling reaction pathways, creating nonequilibrium material properties, and probing complex molecular dynamics. The photoresponse following a laser pulse is generally nonidentical between exposures due to spatiotemporal fluctuations or the stochastic nature of dynamical pathways. However, most ultrafast pump-probe experiments struggle to distinguish intrinsic sample fluctuations from extrinsic apparatus noise, often missing deviations from the averaged response. Leveraging the stability and high photon flux of time-resolved X-ray micro-diffraction at a synchrotron, we characterized stochastic photoinduced dynamics in a solid-state ionic conductor. By analyzing temporal evolutions of the lattice parameter of a single grain, we found that shot-to-shot fluctuations are not independent. Instead, correlations exist between nonequilibrium lattice trajectories following adjacent shots, with a characteristic correlation length of approximately 1500 shots, corresponding to an energy barrier of 0.4 ± 0.1 eV, close to the activation energy of lithium-ion diffusion.

36 MATERIALS SCIENCE↗

Metric analysis of minitrack optical and interferometer data

The network analysis program (NAP-2), which has the capability of simultaneously solving for orbits and tracking station error model terms, was, after several modifications, used in the calibration of minitrack stations using minitrack satellite measurements (self-calibration). Several support programs were written to aid in this task. A simultaneous four-arc solution was obtained. A comparison with optically determined arcs for the same time spans showed rms position differences of 67m, 86m, 124m and 168m for the 4 arcs considered. An apparatus incorporating a diffraction grating was designed and successfully used to measure the drift rate of the Fort Myers MOTS camera drive.

Brown, D. C.↗

Dense plasma focus production in a hypocycloidal pinch

A type of high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production were made. The collapse fronts of the current sheets are well organized, and dense plasma focuses are produced on the axis with radial stability in excess of 5 microns. A plasma density greater than 10 to the 18th power/cubic cm was determined with Stark broadening and CO2 laser absorption. A plasma temperature of approximately 1 keV was measured with differential transmission of soft X-rays through thin foils. Essentially complete absorption of a high-energy CO2 laser beam was observed. The advantages of this apparatus over the coaxial plasma focus are in (1) the plasma volume, (2) the stability, (3) the containment time, (4) the easy access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗