Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Dynamic Regulation of Sub-Atmospheric Pressure for Constant and Cyclic Gas Loads During Testing of Spacesuit Components

New iterations of the various subsystems within the spacesuit will benefit from a new sorbent technology. For example, sorbents used in the Trace Contaminant Control (TCC) and the Rapid Cycle Amine (RCA) systems within the Exploration Portable Life Support System (xPLSS), part of the Extra-Vehicular Mobility Unit (xEMU). For proper validation, the sub-atmospheric pressure needs to be maintained within a simulated 2 ft 3 spacesuit volume. The traditional approach, which involves placing the entire vent loop within a hypobaric chamber, is not practical for the widespread testing of components and prototypes, as these specialized chambers are costly and not widely available. A two-stage regulator based sub-atmospheric pressure system is presented in this work. The method regulates the pressure based on pressure differentials between the pressure regulation pump, the test system, and the ambient environment. The performance of this system is demonstrated using data collected during a 150+ hour non-regenerative TCC sorbent evaluation, several 24-hour regenerative TCC sorbent evaluations with different regeneration cycles, and an 8-hour RCA sorbent evaluation, all under xEMU operating conditions. For regulation, the inlet regulator was set to propagate a small leak to increase the stability of the system as the gas load from the testing system changes. It was also found that controlling the input flow rate that replaces the material lost during regeneration is critical for ensuring the stability of the system. This system provided excellent pressure regulation, without adjustments, for constant loads during shorter time evaluations (hours), while longer time evaluations (days) are easily obtainable with periodic regulator adjustments. A second method is under development to address longer-term stability and to automate pressure regulation. It will incorporate flow and pressure measurements to dynamically control a set of electronically controlled proportional valves for adjusting the pumping speed and air bleed supply.

Nicholas F Materer↗

Analysis and composition of a model trace gaseous mixture for a spacecraft

Growing concern over trace gaseous contaminant accumulations in the enclosed atmospheres of long duration spacecraft missions has prompted the development of a trace contaminant data base on the basis of gas, lithium hydroxide, and charcoal samples collected on Space Shuttle missions. A model trace contaminant gas mixture containing 14 compounds was chosen with the aid of a FORTRAN program, on the strength of contaminant chemical and toxicological categories, frequency of occurrence, and worst-case concentration. The model gas mixture can be used to test trace contaminant control hardware for a manned spacecraft environment.

Schwartz, M. R.↗

Preliminary results Skylab experiment TO27 optical contamination in space

Current results from the TO27 experiment which was performed on the first two Skylab missions are presented. The purpose of the experiment was to determine the change in optical properties of various transmissive windows, mirrors, and diffraction gratings caused by the deposition of contaminants found about the orbital assembly and to measure the sky brightness background caused by solar illumination of particulate contaminants. The sample array system containing 248 optical surfaces and exposed outside the orbital workshop did not collect any significant contaminants. Only trace amounts of surface deposited contaminants have been seen, in all cases the measurement was near the limiting sensitivity of the instrument. Unfortunate performance compromises and the relative cleanliness of the assembly on the anti-solar side appeared to place the amount of available surface contaminants near the limiting sensitivity of the sample array. Mass spectroscopy on the trace contaminants show the presence of high molecular weight species, up to 773 amu. The data suggests the presence of condensed aromatics.

Muscari, J. A.↗

Offgassing Characterization of the Columbus Laboratory Module

Trace gaseous contamination in the cabin environment is a major concern for manned spacecraft, especially those designed for long duration missions, such as the International Space Station (ISS). During the design phase, predicting the European-built Columbus laboratory module s contribution to the ISS s overall trace contaminant load relied on "trace gas budgeting" based on material level and assembled article tests data. In support of the Qualification Review, a final offgassing test has been performed on the complete Columbus module to gain cumulative system offgassing data. Comparison between the results of the predicted offgassing load based on the budgeted material/assembled article-level offgassing rates and the module-level offgassing test is presented. The Columbus module offgassing test results are also compared to results from similar tests conducted for Node 1, U.S. Laboratory, and Airlock modules.

Rampini, riccardo↗

Destruction of problematic airborne contaminants by hydrogen reduction using a Catalytically Active, Regenerable Sorbent (CARS)

Thermally regenerable sorbent beds were demonstrated to be a highly efficient means for removal of toxic airborne trace organic contaminants aboard spacecraft. The utilization of the intrinsic weight savings available through this technology was not realized since many of the contaminants desorbed during thermal regeneration are poisons to the catalytic oxidizer or form highly toxic oxidation by-products in the Trace Contaminant Control System (TCCS). Included in this class of compounds are nitrogen, sulfur, silicon, and halogen containing organics. The catalytic reduction of these problematic contaminants using hydrogen at low temperatures (200-300 C) offers an attractive route for their destruction since the by-products of such reactions, hydrocarbons and inorganic gases, are easily removed by existing technology. In addition, the catalytic oxidizer can be operated more efficiently due to the absence of potential poisons, and any posttreatment beds can be reduced in size. The incorporation of the catalyst within the sorbent bed further improves the system's efficiency. The demonstration of this technology provides the basis for an efficient regenerable TCCS for future NASA missions and can be used in more conventional settings to efficiently remove environmental pollutants.

Thompson, John O.↗

Predictive Techniques for Spacecraft Cabin Air Quality Control

As assembly of the International Space Station (ISS) proceeds, predictive techniques are used to determine the best approach for handling a variety of cabin air quality challenges. These techniques use equipment offgassing data collected from each ISS module before flight to characterize the trace chemical contaminant load. Combined with crew metabolic loads, these data serve as input to a predictive model for assessing the capability of the onboard atmosphere revitalization systems to handle the overall trace contaminant load as station assembly progresses. The techniques for predicting in-flight air quality are summarized along with results from early ISS mission analyses. Results from groundbased analyses of in-flight air quality samples are compared to the predictions to demonstrate the technique's relative conservatism.

Perry, J. L.↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, pressure range from 3.5 to 14.7 psi, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under liquid water saturation. This paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a spacesuit portable Life support system and the analytical characterization of the optical sensors interrogated by the novel optoelectronic system. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the spacesuit, which may interfere with gas sensor readings. The paper also presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in spacesuits. The studies were conducted with the spacecraft maximum allowable concentrations for those trace gases and the calculated 8-hr. concentrations resulting from having no trace contaminant control system in the ventilation loop. Finally, a profile of temperature, pressure, humidity, and gas composition for a typical EVA mission has been defined, and the performance of sensors operated repeatedly under simulated EVA mission conditions has been studied.

Delgado, Jesus↗

Advanced Life Support Systems: Opportunities for Technology Transfer

NASA's future missions to explore the solar system will be of long-duration possibly lasting years at a time. Human life support systems will have to operate with very high reliability for these long periods with essentially no resupply from Earth. Such life support systems will make extensive use of higher plants, microorganisms, and physicochemical processes for recycling air and water, processing wastes, and producing food. Development of regenerative life support systems will be a pivotal capability for NASA's future human missions. A fully functional closed loop human life support system currently does not exist and thus represents a major technical challenge for space exploration. Technologies where all life support consumables are recycled have many potential terrestrial applications as well. Potential applications include providing human habitation in hostile environments such as the polar regions or the desert in such a way as to minimize energy expenditures and to minimize negative impacts on those often ecologically-sensitive areas. Other potential applications include production of food and ornamental crops without damaging the environment from fertilizers that contaminate water supplies; removal of trace gas contaminants from tightly sealed, energy-efficient buildings (the so-called sick building syndrome); and even the potential of gaining insight into the dynamics of the Earth's biosphere such that we can better manage our global environment. Two specific advanced life support technologies being developed by NASA, with potential terrestrial application, are the zeoponic plant growth system and the Hybrid Regenerative Water Recovery System (HRWRS). The potential applications for these candidate dual use technologies are quite different as are the mechanisms for transfer. In the case of zeoponics, a variety of commercial applications has been suggested which represent potentially lucrative markets. Also, the patented nature of this product offers opportunities for licensing to commercial entities. In the case of the HRWRS, commercial markets with broad applications have not been identified but some terrestrial applications are being explored where this approach has advantages over other methods of waste water processing. Although these potential applications do not appear to have the same broad attraction from the standpoint of rapid commercialization, they represent niches where commercialization possibilities as well as social benefits could be realized.

Fields, B.↗

Evaluating Crustal Contamination Effects On The Lithophile Trace Element Budget Of Shergottites, NWA 856 As A Test Case

The issue of whether crustal contamination has affected the lithophile trace element budget of shergottites has been a point of contention for decades. The evaluation has focused on the enriched shergottite compositions as an outcome of crustal contamination of mantle-derived parent magmas or, alternatively, the compositions of these stones reflect an incompatible trace element (ITE) enriched mantle source.

Brandon, A. D.↗

Developmental Hardware Testing Results and Forward Plans for the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Developmental Hardware Testing Results and Forward Plans for Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM)

We present testing results for developmental hardware of the Spacecraft Water Impurity Monitor (SWIM) Organic Water Module (OWM). SWIM-OWM will monitor spacecraft potable water and system water for trace organic contaminants. The system will detect and identify the specific organic chemical that makes up a given total organic carbon reading. We have built a first development unit (1DU) for SWIM-OWM, which directly injects aqueous water samples and detects chemicals with both a thermal conductivity detector and mass spectrometer sensor. The gas chromatography mass spectrometer (GCMS) system that comprises SWIM-OWM draws on the success of ISS-proven mass spectrometer hardware, and the demonstration of GCMS detection of trace organic contaminants in ISS cabin air. SWIM-OWM benefits from the excellent sensitivity and specificity afforded by GCMS. We have demonstrated detection of a set of chemicals relevant to both crew health and performance as well as system monitoring; these target chemicals range from light, volatile organics such as acetone and ethanol, to heavier, very non-volatile compounds such as dimethyl sulfone and o-phthalaldehyde. Direct aqueous injection was chosen for the general applicability of the technique to clean water sampling and to preclude sample pre-processing, which facilitates an on-line implementation of the SWIM-OWM when deployed in a spacecraft or habitation module. A specific advantage of direct aqueous injection when coupled with appropriate methods is that both the light, volatile organics and heavier non-volatiles can be detected from a single injection, in a single chromatogram. Results from 1DU testing will be discussed, and forward plans will be outlined for continued maturation of SWIM-OWM with the goal of implementing a technology demonstration for the purposes of maturing the engineering design and operations in an environment relevant to NASA’s future goals of exploring and setting up habitation on the Moon and Mars.

Water Monitoring↗

Modeling Geometric Arrangements of TiO2-Based Catalyst Substrates and Isotropic Light Sources to Enhance the Efficiency of a Photocatalystic Oxidation (PCO) Reactor

The closed confined environments of the ISS, as well as in future spacecraft for exploration beyond LEO, provide many challenges to crew health. One such challenge is the availability of a robust, energy efficient, and re-generable air revitalization system that controls trace volatile organic contaminants (VOCs) to levels below a specified spacecraft maximum allowable concentration (SMAC). Photocatalytic oxidation (PCO), which is capable of mineralizing VOCs at room temperature and of accommodating a high volumetric flow, is being evaluated as an alternative trace contaminant control technology. In an architecture of a combined air and water management system, placing a PCO unit before a condensing heat exchanger for humidity control will greatly reduce the organic load into the humidity condensate loop ofthe water processing assembly (WPA) thereby enhancing the life cycle economics ofthe WPA. This targeted application dictates a single pass efficiency of greater than 90% for polar VOCs. ~ Although this target was met in laboratory bench-scaled reactors, no commercial or SBIR-developed prototype PCO units examined to date have achieved this goal. Furthermore, the formation of partial oxidation products (e.g., acetaldehyde) was not eliminated. It is known that single pass efficiency and partial oxidation are strongly dependent upon the contact time and catalyst illumination, hence the requirement for an efficient reactor design. The objective of this study is to maximize the apparent contact time and illuminated catalyst surface area at a given reactor volume and volumetric flow. In this study, a Ti02-based photocatalyst is assumed to be immobilized on porous substrate panels and illumination derived from linear isotropic light sources. Mathematical modeling using computational fluid dynamics (CFD) analyses were performed to investigate the effect of: 1) the geometry and configuration of catalyst-coated substrate panels, 2) porosity of the supporting substrate, and 3) varying the light source and spacing on contact time and illuminated catalyst area.

Richards, Jeffrey T.↗

Monitoring spacecraft atmosphere contaminants by laser absorption spectroscopy

Laser-based spectrophotometric methods which have been proposed for the detection of trace concentrations of gaseous contaminants include Raman backscattering (LIDAR) and passive radiometry (LOPAIR). Remote sensing techniques using laser spectrometry are presented and in particular a simple long-path laser absorption method (LOLA), which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels is discussed. A number of species were selected for study which are representative of those most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Computer programs were developed which will permit a real-time analysis of the monitored atmosphere. Estimates of the dynamic range of this monitoring technique for various system configurations, and comparison with other methods of analysis, are given.

Steinfeld, J. I.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗