Search NASA⌕ Search

SEARCH · Search NASA

Results for “Three dimensional imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Three Dimensional Instantaneous Spray Measurements of Additively Manufactured Candidate Injector Schemes at Varying Pressure Drops

Additively manufactured (AM) injectors have the potential to improve upon the combustion performance achieved using traditionally manufactured (TM) injectors. Traditionally manufactured injector combustion performance decreases greatly in off-design conditions. Additively manufactured injectors hold the potential to sustain high combustion performance over a broader range of operating conditions than currently seen in TM injectors. Additively manufactured injectors promise to offer higher resistances to instability and achieve better overall propellant mixing and atomization for all types of combustion devices. This study expands upon previous studies that used 2-D imaging techniques to characterize the injector spray pattern of candidate AM injector elements. In this study, 3-D instantaneous measurements of the injector spray pattern are taken, allowing for deeper insight into the liquid spray breakup, an inherently 3-D phenomena. Stereo imaging is used for three dimensional analysis, which utilizes two cameras at different angles to reconstruct a three dimensional reconstruction. With this information, AM injectors can be designed to improve propellant mixing and atomization and reduce breakup length. As part of this work, a high-pressure, cold flow experimental spray facility was modified to measure each injector’s spray characteristics in terms of 𝑅𝑒 𝐿 and 𝑊𝑒 𝑔 . This facility is operated to capture instantaneous stereo photographic images, mass flow rates, and injector element thrust for pressure drop across the injector face ranging from 100 to 200 psig at a stiffness ratio of 1.0.

Murphy Mitchell↗

Imaging infrared: Scene simulation, modeling, and real image tracking; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

Various papers on scene simulation, modeling, and real image tracking using IR imaging are presented. Individual topics addressed include: tactical IR scene generator, dynamic FLIR simulation in flight training research, high-speed dynamic scene simulation in UV to IR spectra, development of an IR sensor calibration facility, IR celestial background scene description, transmission measurement of optical components at cryogenic temperatures, diffraction model for a point-source generator, silhouette-based tracking for tactical IR systems, use of knowledge in electrooptical trackers, detection and classification of target formations in IR image sequences, SMPRAD: simplified three-dimensional cloud radiance model, IR target generator, recent advances in testing of thermal imagers, generic IR system models with dynamic image generation, modeling realistic target acquisition using IR sensors in multiple-observer scenarios, and novel concept of scene generation and comprehensive dynamic sensor test.

Triplett, Milton J.↗

Left ventricular endocardial surface detection based on real-time 3D echocardiographic data

OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

Non-NASA Center↗

Three-dimensional ballistocardiography and respiratory motion in sustained microgravity

BACKGROUND: We measured the three-dimensional ballistocardiogram (BCG) in a free-floating subject in sustained microgravity during spaceflight to test the usefulness of such measurements for future non-invasive monitoring of cardiac function, and to examine the effects of respiratory movement on the BCG in three axes. METHODS: Acceleration was measured using a three-axis accelerometer fastened to the lumbar region of the subject while simultaneous recordings of ECG, and respiratory motion via impedance plethysmography were also made. Data were recorded during a 146-s period of inactivity on the part of the subject during which time there was no contact with the spacecraft. RESULTS: Total body motion due to respiratory activity was consistent with that calculated from the known action of the diaphragm and conservation of momentum. The accelerations due to cardiac activity, ensemble averaged over the R-R interval, were greatest along the head-to-foot axis. Maximum amplitude of the HIJK complex of the BCG generated by ventricular ejection was greatest in the head to foot axis (approximately 70 x 10(-3) m x s(-2)), but there were also substantial accelerations along the dorsoventral axis of up to 43 10(-3) m x s(-2), that are not measured interrestrial two-dimensional studies. The amplitude of the BCG was strongly affected by lung volume, with accelerations being reduced 50 to 70% between end-inspiration and end-expiration. CONCLUSIONS: These data suggest a greatly reduced transmission of the cardiac motion to the body at end-expiration (FRC) than at higher lung volumes. The BCG might be further developed as a non-invasive means of monitoring parameters such as stroke volume in microgravity.

Flight Experiment↗

Improving 3D Wavelet-Based Compression of Hyperspectral Images

Two methods of increasing the effectiveness of three-dimensional (3D) wavelet-based compression of hyperspectral images have been developed. (As used here, images signifies both images and digital data representing images.) The methods are oriented toward reducing or eliminating detrimental effects of a phenomenon, referred to as spectral ringing, that is described below. In 3D wavelet-based compression, an image is represented by a multiresolution wavelet decomposition consisting of several subbands obtained by applying wavelet transforms in the two spatial dimensions corresponding to the two spatial coordinate axes of the image plane, and by applying wavelet transforms in the spectral dimension. Spectral ringing is named after the more familiar spatial ringing (spurious spatial oscillations) that can be seen parallel to and near edges in ordinary images reconstructed from compressed data. These ringing phenomena are attributable to effects of quantization. In hyperspectral data, the individual spectral bands play the role of edges, causing spurious oscillations to occur in the spectral dimension. In the absence of such corrective measures as the present two methods, spectral ringing can manifest itself as systematic biases in some reconstructed spectral bands and can reduce the effectiveness of compression of spatially-low-pass subbands. One of the two methods is denoted mean subtraction. The basic idea of this method is to subtract mean values from spatial planes of spatially low-pass subbands prior to encoding, because (a) such spatial planes often have mean values that are far from zero and (b) zero-mean data are better suited for compression by methods that are effective for subbands of two-dimensional (2D) images. In this method, after the 3D wavelet decomposition is performed, mean values are computed for and subtracted from each spatial plane of each spatially-low-pass subband. The resulting data are converted to sign-magnitude form and compressed in a manner similar to that of a baseline hyperspectral- image-compression method. The mean values are encoded in the compressed bit stream and added back to the data at the appropriate decompression step. The overhead incurred by encoding the mean values only a few bits per spectral band is negligible with respect to the huge size of a typical hyperspectral data set. The other method is denoted modified decomposition. This method is so named because it involves a modified version of a commonly used multiresolution wavelet decomposition, known in the art as the 3D Mallat decomposition, in which (a) the first of multiple stages of a 3D wavelet transform is applied to the entire dataset and (b) subsequent stages are applied only to the horizontally-, vertically-, and spectrally-low-pass subband from the preceding stage. In the modified decomposition, in stages after the first, not only is the spatially-low-pass, spectrally-low-pass subband further decomposed, but also spatially-low-pass, spectrally-high-pass subbands are further decomposed spatially. Either method can be used alone to improve the quality of a reconstructed image (see figure). Alternatively, the two methods can be combined by first performing modified decomposition, then subtracting the mean values from spatial planes of spatially-low-pass subbands.

Klimesh, Matthew↗

Three-dimensional characterization of tethered microspheres by total internal reflection fluorescence microscopy

Tethered particle microscopy is a powerful tool to study the dynamics of DNA molecules and DNA-protein complexes in single-molecule experiments. We demonstrate that stroboscopic total internal reflection microscopy can be used to characterize the three-dimensional spatiotemporal motion of DNA-tethered particles. By calculating characteristic measures such as symmetry and time constants of the motion, well-formed tethers can be distinguished from defective ones for which the motion is dominated by aberrant surface effects. This improves the reliability of measurements on tether dynamics. For instance, in observations of protein-mediated DNA looping, loop formation is distinguished from adsorption and other nonspecific events.

Non-NASA Center↗

Report on New Mission Concept Study: Stereo X-Ray Corona Imager Mission

Studies of the three-dimensional structure and dynamics of the solar corona have been severely limited by the constraint of single viewpoint observations. The Stereo X-Ray Coronal Imager (SXCI) mission will send a single instrument, an X-ray telescope, into deep space expressly to record stereoscopic images of the solar corona. The SXCI spacecraft will be inserted into a approximately 1 AU heliocentric orbit leading Earth by approximately 25 deg at the end of nine months. The SXCI X-ray telescope forms one element of a stereo pair, the second element being an identical X-ray telescope in Earth orbit placed there as part of the NOAA GOES program. X-ray emission is a powerful diagnostic of the corona and its magnetic fields, and three dimensional information on the coronal magnetic structure would be obtained by combining the data from the two X-ray telescopes. This information can be used to address the major solar physics questions of (1) what causes explosive coronal events such as coronal mass ejections (CMEs), eruptive flares and prominence eruptions and (2) what causes the transient heating of coronal loops. Stereoscopic views of the optically thin corona will resolve some ambiguities inherent in single line-of-sight observations. Triangulation gives 3D solar coordinates of features which can be seen in the simultaneous images from both telescopes. As part of this study, tools were developed for determining the 3D geometry of coronal features using triangulation. Advanced technologies for visualization and analysis of stereo images were tested. Results of mission and spacecraft studies are also reported.

Liewer, Paulett C.↗

Terahertz Computed Tomography of NASA Thermal Protection System Materials

A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.

Roth, D. J.↗

Recognition of 3-D symmetric objects from range images in automated assembly tasks

A new technique is presented for the three dimensional recognition of symmetric objects from range images. Beginning from the implicit representation of quadrics, a set of ten coefficients is determined for symmetric objects like spheres, cones, cylinders, ellipsoids, and parallelepipeds. Instead of using these ten coefficients trying to fit them to smooth surfaces (patches) based on the traditional way of determining curvatures, a new approach based on two dimensional geometry is used. For each symmetric object, a unique set of two dimensional curves is obtained from the various angles at which the object is intersected with a plane. Using the same ten coefficients obtained earlier and based on the discriminant method, each of these curves is classified as a parabola, circle, ellipse, or hyperbola. Each symmetric object is found to possess a unique set of these two dimensional curves whereby it can be differentiated from the others. It is shown that instead of using the three dimensional discriminant which involves evaluation of the rank of its matrix, it is sufficient to use the two dimensional discriminant which only requires three arithmetic operations.

Alvertos, Nicolas↗

Stereo Imaging Velocimetry

A system and a method for measuring three-dimensional velocities at a plurality of points in a fluid employing at least two cameras positioned approximately perpendicular to one another. The cameras are calibrated to accurately represent image coordinates in world coordinate system. The two-dimensional views of the cameras are recorded for image processing and centroid coordinate determination. Any overlapping particle clusters are decomposed into constituent centroids. The tracer particles are tracked on a two-dimensional basis and then stereo matched to obtain three-dimensional locations of the particles as a function of time so that velocities can be measured therefrom The stereo imaging velocimetry technique of the present invention provides a full-field. quantitative, three-dimensional map of any optically transparent fluid which is seeded with tracer particles.

McDowell, Mark↗

Temperature, Pressure, and Infrared Image Survey of an Axisymmetric Heated Exhaust Plume

The focus of this research is to numerically predict an infrared image of a jet engine exhaust plume, given field variables such as temperature, pressure, and exhaust plume constituents as a function of spatial position within the plume, and to compare this predicted image directly with measured data. This work is motivated by the need to validate computational fluid dynamic (CFD) codes through infrared imaging. The technique of reducing the three-dimensional field variable domain to a two-dimensional infrared image invokes the use of an inverse Monte Carlo ray trace algorithm and an infrared band model for exhaust gases. This report describes an experiment in which the above-mentioned field variables were carefully measured. Results from this experiment, namely tables of measured temperature and pressure data, as well as measured infrared images, are given. The inverse Monte Carlo ray trace technique is described. Finally, experimentally obtained infrared images are directly compared to infrared images predicted from the measured field variables.

Nelson, Edward L.↗

Direct Imaging of Hydrogen‐Driven Dislocation and Strain Field Evolution in a Stainless Steel Grain

Hydrogen embrittlement (HE) poses a significant challenge to the durability of materials used in hydrogen production and utilization. Disentangling the competing nanoscale mechanisms driving HE often relies on simulations and electron-transparent sample techniques, limiting experimental insights into hydrogen-induced dislocation behavior in bulk materials. This study employs in situ Bragg coherent X-ray diffraction imaging to track three-dimensional (3D) dislocation and strain field evolution during hydrogen charging in a bulk grain of austenitic 316 stainless steel. Tracking a single dislocation reveals hydrogen-enhanced mobility and relaxation, consistent with dislocation dynamics simulations. Subsequent observations reveal dislocation unpinning and climb processes, likely driven by osmotic forces. Additionally, nanoscale strain analysis around the dislocation core directly measures hydrogen-induced elastic shielding. These findings experimentally validate theoretical predictions and offer mechanistic insights into hydrogen-driven dislocation behavior. The quantified nanoscale phenomena serve as critical inputs for multiscale modeling frameworks to predict bulk material responses and accelerate the development of HE-resistant alloys.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physiological Feedback Method and System

A method and system provide physiological feedback for a patient and/or physician. At least one physiological effect experienced by a body part of a patient is measured noninvasively. A three-dimensional graphics model serving as an analogous representation of the body part is altered in accordance with the measurements. A binocular image signal representative of the three-dimensional graphics model so-altered is displayed for the patient and/or physician in a virtual reality environment.

Pope, Alan T.↗

Electron ptychography reveals a ferroelectricity dominated by anion displacements

Sodium niobate, a lead-free ferroic material, hosts delicately balanced, competing order parameters, including ferroelectric states that can be stabilized by epitaxial strain. Here we show that the resulting macroscopic ferroelectricity exhibits an unconventional microscopic structure using multislice electron ptychography. This technique overcomes multiple scattering artefacts limiting conventional electron microscopy, enabling both lateral spatial resolution beyond the diffraction limit and recovery of three-dimensional structural information. These imaging capabilities allow us to separate the ferroelectric interior of the sample from the relaxed surface structure and identify the soft phonon mode and related structural distortions with picometre precision. Unlike conventional ferroelectric perovskites, we find that the polar distortion in this material involves minimal distortions of the cation sublattices and is instead dominated by anion displacements relative to the niobium sublattice. We establish limits on film thickness for interfacial octahedral rotation engineering and directly visualize a random octahedral rotation pattern, arising from the flat dispersion of the associated phonon mode.

ferroelectrics and multiferroics↗

Screen of cylindrical lenses produces stereoscopic television pictures

Stereoscopic television pictures are produced by placing a colorless, transparent screen of adjacent parallel cylindrical lenses before a raster from two synchronized TV cameras. Alternate frames from alternate cameras are displayed. The viewers sensory perception fuses the two images into one three-dimensional picture.

Nork, C. L.↗

Quantitative density visualization in a transonic rotor

The flow in a two foot diameter transonic rotor has been visualized using a fluorescent gas, 2, 3 butanedione, as a tracer. The technique allows the three dimensional flow to be imaged as a set of distinct planes. Quantitative static density maps can be obtained after correcting the images for distortion and nonlinearities introduced by the illumination and imaging systems. The visualized flow is compared to data taken simultaneously by high frequency pressure transducers near the rotor entrance and exit planes.

Epstein, A. H.↗

Flow visualization studies of transverse fuel injection patterns in a nonreacting Mach 2 combustor

Planar visualization images are recorded of transverse jet mixing in a supersonic combustor flowfield, without chemical reaction, using laser-induced fluorescence from iodine molecules. Digital image processing and three-dimensional display enable complete representations of fuel penetration boundary and shock surfaces corresponding to several injection geometries and pressures.

Mcdaniel, J. C.↗