Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Ground Validation Network for the Global Precipitation Measurement Mission

A prototype Validation Network (VN) is currently operating as part of the Ground Validation System for NASA's Global Precipitation Measurement (GPM) mission. The VN supports precipitation retrieval algorithm development in the GPM prelaunch era. Postlaunch, the VN will be used to validate GPM spacecraft instrument measurements and retrieved precipitation data products. The period of record for the VN prototype starts on 8 August 2006 and runs to the present day. The VN database includes spacecraft data from the Tropical Rainfall Measuring Mission (TRMM) precipitation radar (PR) and coincident ground radar (GR) data from operational meteorological networks in the United States, Australia, Korea, and the Kwajalein Atoll in the Marshall Islands. Satellite and ground radar data products are collected whenever the PR satellite track crosses within 200 km of a VN ground radar, and these data are stored permanently in the VN database. VN products are generated from coincident PR and GR observations when a significant rain event occurs. The VN algorithm matches PR and GR radar data (including retrieved precipitation data in the case of the PR) by calculating averages of PR reflectivity (both raw and attenuation corrected) and rain rate, and GR reflectivity at the geometric intersection of the PR rays with the individual GR elevation sweeps. The algorithm thus averages the minimum PR and GR sample volumes needed to "matchup" the spatially coincident PR and GR data types. The result of this technique is a set of vertical profiles for a given rainfall event, with coincident PR and GR samples matched at specified heights throughout the profile. VN data can be used to validate satellite measurements and to track ground radar calibration over time. A comparison of matched TRMM PR and GR radar reflectivity factor data found a remarkably small difference between the PR and GR radar reflectivity factor averaged over this period of record in stratiform and convective rain cases when samples were taken from high in the atmosphere. A significant difference in PR and GR reflectivity was found in convective cases, particularly in convective samples from the lower part of the atmosphere. In this case, the mean difference between PR and corrected GR reflectivity was -1.88 dBZ. The PR-GR bias was found to increase with the amount of PR attenuation correction applied, with the PR-GR bias reaching -3.07 dBZ in cases where the attenuation correction applied is greater than 6 dBZ. Additional analysis indicated that the version 6 TRMM PR retrieval algorithm underestimates rainfall in case of convective rain in the lower part of the atmosphere by 30%-40%.

Schwaller, Mathew R.↗

Lessons Learned in Building Long-Term Multi-Satellite Global Precipitation Records

Efforts to construct long-term global precipitation data sets from the decades-long record of satellite (and other) data historically have fallen into one of two categories. Climate Data Records (CDR), such as the Global Precipitation Climatology Project (GPCP), prioritize homogeneity over fine-scale accuracy. On the other hand, High Resolution Precipitation Products (HRPP), such as the Tropical Rainfall Measuring Mission (TRMM) Multi-satellite Precipitation Analysis (TMPA), emphasize the use of data from all available satellites. For both types of products, experience has shown that it is critical to choose the appropriate reference standard to intercalibrate an ever-evolving constellation of satellite sensors. Towards this end, we have used passive microwave (PMW) in developing GPCP, and combined PMW-radar in TMPA.The launch of the TRMM follow-on Global Precipitation Measurement (GPM) mission in 2014 gave birth to several nearly-global HRPP's, including the Integrated Multi-satellitE Retrievals for GPM (IMERG). Our strategy in refining IMERG has been to first focus on the tropics and mid-latitudes, where we have relatively high confidence, and only more recently begin to expand into the lower-confidence high latitudes. Similarly, although GPCP has provided nearly-global estimates since its inception in the early 1990's, the advent of sensors such as CloudSat has facilitated new efforts to modernize its estimates at high latitudes.For each of these data sets, it is expected that the final merged estimate should tend to track along with its respective calibration standard. Time series depicting GPCP, TMPA, and IMERG will be presented, in order to demonstrate the extent to which this is so. Additionally, comparisons amongst the products will show areas of agreement and highlight areas where further improvements are needed.

Nelkin, Eric J.↗

SNPP VIIRS Reflective Solar Bands On-Orbit Calibration Using the Moon

The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the Suomi National Polar-Orbiting Partnership (SNPP) satellite has been on orbit for more than eight years since its launch on October 28, 2011. The VIIRS has 22 spectral bands, among which 14 are reflective solar bands(RSBs) covering a spectral range from 0.41 to 2.25 m. The VIIRS RSBs are primarily calibrated on-orbit by an onboard solar diffuser (SD) panel and a solar diffuser stability monitor (SDSM). Besides the SD and SDSM calibration, the RSBs are scheduled to view the Moon approximately monthly through the instrument’s space view (SV). The lunar observations have also been used to calibrate the RSBs on-orbit since early mission. Due to the non uniformity of the SD’s degradation, the calibration coefficients that are derived from the SD/SDSM calibration have long-term biases, especially at short wavelengths. In addition, the SDSM has no capability to monitor the SD degradation beyond 0.935 m, resulting in long-term bias in the shortwave infrared bands, about 0.72% for band M8 (1.238 m). These biases induce significant errors and long-term drifts in the VIIRS sensor data records (SDR) and consequently in the environmental data records (EDR). Unlike the SD, the Moon is a known stable target and any temporal drifts observed while viewing the Moon can be attributed to the sensor’s degradation. Thus, the VIIRS lunar calibration is used to track the RSB on-orbit changes, especially to provide an accurate long-term baseline. Due to the non-uniformity of the lunar surface, the lunar irradiance, instead of the lunar radiance, is used to calibrate the RSBs. The lunar irradiance strongly depends on lunar view geometry and it is still a challenge to accurately characterize the geometric effects associated with the lunar measurements and any residual errors can induce seasonal oscillations in the derived calibration coefficients. The errors of the geometric dependence correction induce seasonal oscillations in the derived RSB lunar calibration coefficients. In this paper, the algorithms for the view geometric effect correction are significantly improved, resulting in a significant reduction in the seasonal oscillations observed in the calibration coefficient time-series. The lunar and SD/SDSM calibration results are properly incorporated to generate a set of hybrid calibration coefficients and implementation of these coefficients is shown to significantly improve the long-term stability of the VIIRS SDR. This is of fundamental importance in making accurate Earth observations from which reliable and high quality science products are generated. The consequent improvements in SNPP VIIRS RSB SDRs and EDRs are shown and discussed. The lunar calibration methodology can be directly applied to follow-on VIIRS instruments.

Junqiang Sun↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

3D Scanning System to Assess Gravity-Dependent Body Shape Changes

The human body shows unique physiological and morphological changes when exposed to different gravity conditions, including muscle atrophy, fluid shift, spinal elongation, and body posture adjustments. Such changes need to be incorporated for human-system integration in the vehicle habitat, garment, and spacesuit designs, as inaccurate body measurements can result in suboptimal crew protection that can potentially decrease injury tolerance. However, the traditional linear measurements, such as stature, segment lengths or circumferences measured using a caliper or tape measure, often show limited consistency and are unable to capture the nonlinear characteristics of the human body. While 3D body scanning can provide significant advantages over linear measurements, the technologies have not been fully developed or customized for in-flight scanning. For ground laboratory use, several different scanner types are commercially available. However, in-flight scanning requires additional technical considerations, such as minimal scan time, simplified calibration, and sufficient capture volume. This work aims to develop a prototype 3-D body scanning system that is customized for in-flight use to scan crewmembers, with the configuration and performance optimized for detecting known gravity-dependent body shape and posture changes. A hardware system will be custom built using a network of commercial off-the-shelf 3D sensors. The sensor parameters and settings will be optimized to detect the targeted body shape changes, specifically using body manikins of which the shape and size are iteratively permuted to simulate the known changes by fluid shift and spinal elongation. The capture volume will be also matched for a range of body sizes from a 1st percentile female to 99th percentile male. Unintentional body motions or floating in microgravity will be also simulated and incorporated. A data acquisition software will be developed for efficient in-flight operations with minimal overhead and easy-to-use user interface. A simplified calibration procedure will be designed for robust scanning against frequent vibration or unexpected sensor position shifts. The system will be tested in the ground laboratory for accuracy and reliability against a reference scanning system. New anthropometry measurements will be also identified to sensitively capture the gravity dependent body shape changes, in addition to the traditional anthropometry measurements. A novel landmark-based technique will be tested for consistent anthropometry measurements across posture variations. If successfully developed and deployed, the new system is expected to provide previously unavailable body shape and size data from different gravitational environments, including 0-g, 1/6-g, and 1-g. Such data can improve suit fit, habitat design, exercise efficacy quantification and sizing of orthostatic intolerance garments.

K H Kim↗

Muon Anomalous Precession Frequency Measurement Using Lead Fluoride Calorimeters in the Muon g-2 Experiment

aThe Standard Model (SM) of particle physics has been strikingly successful in explaining a wide range of physical phenomena and almost all experimental results. One of the most significant discrepancies at present is the anomalous magnetic moment $a_\mu$=(g−2)/2 of the muon, which was measured by the E821 collaboration at BNL in 2004 to be more than three-standard-deviation greater than the SM prediction. Various models beyond SM physics have been proposed to explain this discrepancy, but the key to resolving this tension remains a more precise measurement of $a_{\mu}$. The Muon g-2 collaboration at Fermilab aims to measure $a_{\mu}$ with a precision goal of 140 parts per billion, a fourfold improvement over BNL's result. If the central values of the experimental result and the theoretical prediction remain unchanged, the discrepancy will exceed seven standard deviations which a clear indication of physics beyond SM. In this poster, preliminary results from th e ongoing physics data taking will be presented, especially on the measurement of the muon anomalous precession frequency using lead fluoride calorimeters. Energy calibration and timing alignment procedures of calorimeter channels will also be described, and their impact on high-level analyses will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of the Clear-Sky Spectral Error for Radiometer Classification in ISO 9060: Preprint

A recent update of the ISO 9060 standard for the classification of solar radiometers introduces the use of the clear sky spectral error. The spectral error is the change in responsivity that may occur when the spectral distribution of the incident solar radiation differs from the spectral distribution present at the time of calibration. Spectral errors may occur if the radiometer does not have a completely uniform spectral responsivity. This use of the clear sky spectral error is a significant change compared to the previous version of the 9060 standard as now not only thermopile radiometers, but also photodiode radiometers are covered by the standard. We explain the method used to derive the spectral error and present spectral errors for several radiometers of different technologies. The results demonstrate that the new method is helpful to classify radiometers, distinguishing between different radiometer types and excluding inappropriate instruments from the classification as pyranometers and pyrheliometers. We recommend that the method is also used for WMO's radiometer classification which up to our knowledge is currently not fulfilled by any field pyrheliometer and many pyranometers on the market due to its demanding requirements for the spectral responsivity.

14 SOLAR ENERGY↗

Hydrogen Internal Combustion Engine - Franco Ocampo

This intern poster is personal research on a Hydrogen Internal Combustion Engine. The poster oversees the core problems with the idea of a HICE. The main problem addressed is abnormal combustion which can be a safety hazard firstly, but also mitigate the performance of the engine severely. Solutions include direct fuel injection, alternative cooling systems, and closer attention to valve timing and calibration in relation to fuel delivery.

08 - HYDROGEN↗

VIIRS On-Orbit Calibration for Ocean Color Data Processing

The NASA VIIRS Ocean Science Team (VOST) has the task of evaluating Suomi NPP VIIRS ocean color data for the continuity of the NASA ocean color climate data records. The generation of science quality ocean color data products requires an instrument calibration that is stable over time. Since the VIIRS NIR Degradation Anomaly directly impacts the bands used for atmospheric correction of the ocean color data (Bands M6 and M7), the VOST has adapted the VIIRS on-orbit calibration approach to meet the ocean science requirements. The solar diffuser calibration time series and the solar diffuser stability monitor time series have been used to derive changes in the instrument response and diffuser reflectance over time for bands M1-M11.

Eplee, Robert E., Jr.↗

A Self Calibrating Emissivity and/or Transmissivity Independent Multiwavelength Pyrometer

Pyrometer is a favorite method to do remote temperature measurement in research and development. One-color, two-color and the disappearing filament pyrometers are most common, multicolor and multiwavelength pyrometers are being introduced recently. All these pyrometers invariably require, in one form or another, information concerning emissivity, the medium transmissivity, their ratio at some two spectral regions, the instrument's calibration constant, etc. for their operation. This information can come from hand books, from the manufacturer or in some instances, from results of dedicated separate experiments. Often this information is sample or instrument specific. Sometimes this information, though obtained from a special experiment, is obtained using a separate sample rather than the one pursued for temperature measurement. Then, there would be the question of variability from sample to sample and variability from batch to batch in the sample used. Also, previously determined calibrations can change with time, and the only way to reduce uncertainty is to perform the calibration more frequently or even immediately before the experiment. We have developed a multiwavelength pyrometer, which eliminates the need to supply the necessary emissivity and/or transmissivity information and the instrument calibration constants ahead of time. The pyrometer calibrates itself from its first cycle data.

Ng, Daniel↗

Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

Tripp, John S.↗

Calibration of the 11x11-Foot Transonic Wind Tunnel at NASA Ames Research Center

A static pipe calibration characterizing the streamwise static pressure distribution was conducted at the 11-By 11-Foot Transonic Wind Tunnel at NASA Ames Research Center. This data is used to determine the local Mach number within the test section and evaluate buoyancy corrections to axial force measurements. The 60 foot long, 6 inch diameter pipe contained 444 static pressure taps spanning the test section and nozzle regions of the tunnel. The forward end of the pipe extends into the settling chamber and is held by four cables mounting to the tunnel shell, and the aft end is fixed on the institutional model support system. A hydraulic cylinder at the aft end of the pipe provides tension on the system to reduce vibration and to keep the pipe as level as possible throughout the test section. The previous calibration was improved upon by using pressure scanners with greater accuracy, ensuring a uniform pressure tube length for each tap to control pneumatic lag, optically tracking any streamwise movement of the pipe, and more tightly controlling the tunnel condition set points. Typically this calibration is conducted with the pipe on tunnel centerline and 33 inches below centerline for sting-mounted models and semi-span (i.e. floor-mounted) models respectively, however schedule demands permitted only the centerline calibration. The semi-span calibration is planned to be completed in the summer of 2020. Immediately following the static pipe calibration, a shorter, 9 foot static pipe used as the calibration check standard was installed to obtain its first post-calibration pressure dataset. This short static pipe consists of 148 static pressure taps distributed along the pipe section and one total pressure tap at the end of an ogive nose. Performing the calibration test and its check standard back-to-back allows this dataset to establish a reliable baseline for future calibration check standard testing. Over time the use of a calibration check standard offers the ability to assess the stability of the calibration through statistical process control in an efficient and costeffective manner, thereby potentially increasing the time required between full tunnel calibrations.

White, Bethany↗

First Evaluation of the Climatological Calibration Algorithm in the Real-time TMPA Precipitation Estimates over Two Basins at High and Low Latitudes

The TRMM Multi-satellite Precipitation Analysis (TMPA) system underwent a crucial upgrade in early 2009 to include a climatological calibration algorithm (CCA) to its realtime product 3B42RT, and this algorithm will continue to be applied in the future Global Precipitation Measurement era constellation precipitation products. In this study, efforts are focused on the comparison and validation of the Version 6 3B42RT estimates before and after the climatological calibration is applied. The evaluation is accomplished using independent rain gauge networks located within the high-latitude Laohahe basin and the low-latitude Mishui basin, both in China. The analyses indicate the CCA can effectively reduce the systematic errors over the low-latitude Mishui basin but misrepresent the intensity distribution pattern of medium-high rain rates. This behavior could adversely affect TMPA's hydrological applications, especially for extreme events (e.g., floods and landslides). Results also show that the CCA tends to perform slightly worse, in particular, during summer and winter, over the high-latitude Laohahe basin. This is possibly due to the simplified calibration-processing scheme in the CCA that directly applies the climatological calibrators developed within 40 degrees latitude to the latitude belts of 40 degrees N-50 degrees N. Caution should therefore be exercised when using the calibrated 3B42RT for heavy rainfall-related flood forecasting (or landslide warning) over high-latitude regions, as the employment of the smooth-fill scheme in the CCA bias correction could homogenize the varying rainstorm characteristics. Finally, this study highlights that accurate detection and estimation of snow at high latitudes is still a challenging task for the future development of satellite precipitation retrievals.

TMPA-RT Precipitation Estimates↗

Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solid water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.

60 APPLIED LIFE SCIENCES↗

In-flight radiometric calibration of AVIRIS in 1994

The AVIRIS sensor must be calibrated at the time it measures spectra from the ER-2 airborne platform in order to achieve research and application objectives that are both quantitative and physically based. However, the operational environment inside the Q-bay of the ER-2 at 20 km altitude differs from that in the AVIRIS laboratory with respect to temperature, pressure, vibration, and high-frequency electromagnetic fields. Experiments at surface calibration targets are used in each flight season to confirm the accuracy of AVIRIS in-flight radiometric calibrations. For these experiments, the MODTRAN radiative transfer code is constrained by using in situ measurements to independently predict the upwelling spectral radiance arriving at AVIRIS for a specific calibration target. AVIRIS calibration is validated in flight by comparing the MODTRAN-predicted radiance to the laboratory-calibrated radiance measured by the AVIRIS sensor for the same time over the calibration target. We present radiometric calibration results for the AVIRIS in-flight calibration experiment held at the beginning of the 1994 flight season.

Green, Robert O.↗

In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall

The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗