Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

FPGA-based trigger system for the LUX dark matter experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Measurements of Inclusive Muon Neutrino Charged Current Differential Cross Sections on Argon at 0.8 GeV Average Neutrino Energy with the MicroBooNE Detector

Current and next-generation precision neutrino oscillation experiments aim to determine the neutrino mass ordering, to measure the extent of CP violation in the lepton sector and to probe beyond Standard Model physics, such as sterile neutrinos. These experiments rely on models for neutrino interactions with matter that are complicated by nuclear effects and final state interactions. To date, these effects cannot be modelled precisely, especially for heavy target nuclei, typically used in modern neutrino experiments. Many future experiments will employ detectors based on the liquid argon time projection chamber technology. As a consequence, neutrino-argon cross-section measurements are of the outmost importance, especially given the relative scarcity of neutrino-argon data, due to the novelty of the technology. This thesis presents the first measurement of muon-neutrino charged-current inclusive cross section on argon at a mean neutrino energy of 0.8 GeV. Data were collected using the MicroBooNE liquid argon time projection chamber in the Fermilab Booster neutrino beam during a period of six months, corresponding to an exposure of $1.6 \times 10^{20}$ protons on target. The measured cross section is presented as a function of the outgoing muon momentum, using multiple Coulomb scattering as a measurement technique, as well as the muon angle with respect to the beam direction. A comparison of the measured cross section obtained with two different configurations of the \textsc{Genie} neutrino event generator is performed, and better agreement is found when using nuclear-effect modelling in the theoretical calculations. Additionally, the total flux integrated cross section is measured to be $0.693 \pm 0.010 \, (\text{stat.}) \pm 0.165 \, (\text{syst.}) \times 10^{-38} \, \text{cm}^{2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Neutrons in MicroBooNE

A significant challenge in measurements of neutrino oscillations is reconstructing the incoming neutrino energies. While modern fully-active tracking calorimeters such as liquid argon time projection chambers in principle allow the measurement of all final state particles above some detection threshold, undetected neutrons remain a considerable source of missing energy with little to no data constraining their production rates and kinematics. We present the first demonstration of tagging neutrino-induced neutrons in liquid argon time projection chambers using secondary protons emitted from neutron-argon interactions in the MicroBooNE detector. We describe the method developed to identify neutrino-induced neutrons and demonstrate its performance using neutrons produced in muon-neutrino charged current interactions. The method is validated using a small subset of MicroBooNE's total dataset. The selection yields a sample with $60\%$ of selected tracks corresponding to neutron-induced secondary protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Neutrons in MicroBooNE

A significant challenge in measurements of neutrino oscillations is reconstructing the incoming neutrino energies. While modern fully-active tracking calorimeters such as liquid argon time projection chambers in principle allow the measurement of all final state particles above some detection threshold, undetected neutrons remain a considerable source of missing energy with little to no data constraining their production rates and kinematics. We present the first demonstration of tagging neutrino-induced neutrons in liquid argon time projection chambers using secondary protons emitted from neutron-argon interactions in the MicroBooNE detector. We describe the method developed to identify neutrino-induced neutrons and demonstrate its performance using neutrons produced in muon-neutrino charged current interactions. The method is validated using a small subset of MicroBooNE's total dataset. The selection yields a sample with $60\%$ of selected tracks corresponding to neutron-induced secondary protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗

Semantic segmentation with a sparse convolutional neural network for event reconstruction in MicroBooNE

We present the performance of a semantic segmentation network, SparseSSNet, that provides pixel-level classification of MicroBooNE data. The MicroBooNE experiment employs a liquid argon time projection chamber for the study of neutrino properties and interactions. SparseSSNet is a submanifold sparse convolutional neural network, which provides the initial machine learning based algorithm utilized in one of MicroBooNE's ν e -appearance oscillation analyses. The network is trained to categorize pixels into five classes, which are re-classified into two classes more relevant to the current analysis. The output of SparseSSNet is a key input in further analysis steps. This technique, used for the first time in liquid argon time projection chambers data and is an improvement compared to a previously used convolutional neural network, both in accuracy and computing resource utilization. Here, the accuracy achieved on the test sample is ≥ 99%. For full neutrino interaction simulations, the time for processing one image is ≈ 0.5 sec, the memory usage is at 1 GB level, which allows utilization of most typical CPU worker machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of new MeV-scale capabilities in large neutrino LArTPCs using ambient radiogenic and cosmogenic activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by reconstructing and interpreting MeV-scale energy depositions, or blips, present in their data. We demonstrate new calorimetric and particle discrimination capabilities at the MeV energy scale using reconstructed blips in data from the MicroBooNE LArTPC at Fermilab. We observe a concentration of low-energy (<3 MeV) blips around fiberglass mechanical support struts along the time projection chamber edges with energy spectrum features consistent with the Compton edge of 2.614 MeV 208 Tl decay 𝛾 rays. These features are used to verify proper calibration of electron energy scales in MicroBooNE’s data to few percent precision and to measure the specific activity of 208 Tl in the fiberglass composing these struts, (11.7 ± 0.2⁢(stat) ± 3.1⁢(syst)) Bq/kg. Cosmogenically produced blips above 3 MeV in reconstructed energy are used to showcase the ability of large LArTPCs to distinguish between low-energy proton and electron energy depositions. An enriched sample of low-energy protons selected using this new particle discrimination technique is found to be smaller in data than in dedicated corsika cosmic-ray simulations, suggesting either incorrect corsika modeling of incident cosmic fluxes or particle transport modeling issues in geant4.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GAMPix: a novel fine-grained, low-noise and ultra-low power pixelated charge readout for TPCs

Here, we report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize the use of liquid argon time projection chamber technology for gamma ray astrophysics, for which a fine grained low power charge readout is essential. GAMPix uses a new architecture with coarse and fine scale instrumented electrodes to solve the twin problems of loss of measured charge after diffusion, and high readout power. Fundamentally, it enables low noise and ultra low power charge readout at the spatial scale limited by diffusion in a time projection chamber, and has other possibly applications, including future DUNE modules.

Shutt, Tom↗

Kinematics reconstruction in solenoidal spectrometers operated in active target mode

Here, we discuss the reconstruction of low-energy nuclear reaction kinematics from charged-particle tracks in solenoidal spectrometers working in Active Target Time Projection Chamber mode. In this operation mode, reaction products are tracked within the active gas medium of the Active Target with a three dimensional space point cloud. We have inferred the reaction kinematics from the point cloud using an algorithm based on a linear quadratic estimator (Kalman filter). The performance of this algorithm has been evaluated using experimental data from nuclear reactions measured with the Active Target Time Projection Chamber (AT-TPC) detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Recent Results from ArgoNeuT and Status of MicroBooNE

Liquid Argon Time Projection Chamber (LArTPC) detectors hold the key to answering the outstanding questions about the role of neutrinos in the Standard Model of Particle physics and beyond. Their fine granularity combined with calorimetric capabilities allows for precision measurements that answering these questions will require. Here, we discuss the recent results from the ArgoNeuT experiment as well as the status and prospects for MicroBooNE, both a part of the US-based LArTPC neutrino program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meas. K+ -Ar Total Inelastic Cross Section at ProtoDUNE-SP

ProtoDUNE-SP is a single-phase liquid argon time projection chamber that took hadron test beam data in 2018. The test beam included positively charged kaons with test beam momenta of 6 GeV/c and 7 GeV/c, providing a sample to study kaons to benefit future DUNE proton decay and neutrino interaction studies with kaons in the final state. The total inelastic cross section of a positively charged kaon was measured at these test beam settings using the LArIAT thin-slice method of dividing the wires of the time projection chamber into target slices for calculating the cross section, which leverages the monolithic quality of liquid argon detectors. A Bayesian-like unfolding method using RooUnfold was applied to both the incident and interacting slice distributions to measure the cross sections at both test beam momenta. The talk will discuss the method of unfolding, optimization studies for unfolding, and applying systematic uncertainties using a LArIAT-style hadronic cross section using unfolding to extract a kaon total inelastic cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Large Area Gas Electron Multiplier Detector and Its Application to a Digital Hadron Calorimeter for Future Collider Experiments

The UTA High Energy Physics Group conducted generic detector development based on large area, very thin and high sensitivity gas detector using gas electron multiplier (GEM) technology. This is in preparation for a use as a sensitive medium for sampling calorimeters in future collider experiments at the Energy Frontier as well as part of the tracking detector in Intensity Frontier experiments. We also have been monitoring the long term behavior of one of the prototype detectors (30cmx30cm) read out by the SLAC-developed 13-bit KPiX analog chip over three years and have made presentations of results at various APS meetings. While the important next step was the development of large area (1m x 1m) GEM planes, we also have looked into opportunities of applying this technology to precision tracking detectors to significantly improve the performance of the Range Stack detector for CP violation experiments and to provide an amplification layer for the liquid Argon Time Projection Chamber in the LBNE experiment. We have jointly developed 33cmx100cm large GEM foils with the CERN gas detector development group to construct 33cm x100cm unit chambers. Three of these unit chambers will be put together to form a 1m x 1m detector plane. Following characterization of one 33cmx100cm unit chamber prototype, a total of five 1m x 1m planes will be constructed and inserted into an existing 1m3 RPC DHCAL stack to test the performance of the new GEM DHCAL in particle beams. The large area GEM detector we planned to develop in this proposal not only gives an important option to DHCAL for future collider experiments but also the potential to expand its use to Intensity Frontier and Cosmic Frontier experiments as high efficiency, high amplification anode planes for liquid Argon time projection chambers. Finally, thanks to its sensitivity to X-rays and other neutral radiations and its light-weight characteristics, the large area GEM has a great potential for the use in medical imaging and homeland security, as well as satellite based astronomy experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Voltage Insulation and Gas Absorption of Polymers in High Pressure Argon and Xenon Gases

High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which have not been well characterized in high pressure noble gas environments. As HPGTPCs are scaled up in size toward ton-scale detectors, assemblies become larger and more complex, creating a need for detailed understanding of how structural supports and high voltage insulators behave. This includes the identification of materials with predictable mechanical properties and without surface charge accumulation that may lead to field deformation or sparking. This paper explores the mechanical and electrical effects of high pressure gas environments on insulating polymers PTFE, HDPE, PEEK, POM and UHMW in Argon and Xenon, including studying absorption, swelling and high voltage insulation strength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗

Low-mass Dark Matter Search with the DarkSide-50 Experiment

We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.

Agnes, P↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗