Search NASA⌕ Search

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Method of separation of celestial gamma-ray bursts from solar flares

We recently discovered 217 'new' celestial gamma-ray burst candidates from the 'new' burst search of the PVO real time data base. The burst search covered the time period from September 1978 to July 1988. Sixty were confirmed by at least one other spacecraft, e.g., ISEE-3, V-II, V-12, etc. None triggered the PVO high time resolution memory. In this paper we describe a new algorithm based on the relationship between time width T(w) and hardness ratio HR, to distinguish cosmic gamma-ray bursts from solar flares without knowing the directions of the events. The algorithm was tested with 83 triggered and 60 nontriggered confirmed gamma-ray bursts and 30 confirmed solar flares from PVO.

Chuang, K. W.↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Millisecond time variations in hard X-ray solar flares

The results of a search for fast spikes in 2830 hard X-ray solar flares as observed with the hard X-ray burst spectrometer on the Solar Maximum Mission (SMM) are presented. Hundreds of fast spikes with durations of less than 1 sec have been detected at time resolutions of 128 msec and 10 msec. Fast spikes have been detected with rise and decay times as short as 20 msec and with widths as short as 45 msec. They are the fastest hard X-ray variations yet seen from the sun. The observations of such fast variations place new constraints on the physical nature of the source, and these observations and constraints are discussed in terms of nonthermal and thermal models of flares.

Kiplinger, A. L.↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The High Resolution Spectrograph for the Space Telescope

The High Resoltuion Spectrograph (HRS) in conjunction with the Space Telescope (ST), extends ultraviolet astronomical spectroscopy to higher spectra, spatial, and time resolutions than previously achieved, as well as to fainter and more distant celestial objects. Other significant advances inherent in the instrument are high photometric accuracy and efficient operation via exposure meter control and real time rejection of bad data. These capabilities are provided to accomplish the scientific programs of the HRS investigation definition team, which concern the interstellar medium, stellar winds, and evolutionary aspects of stellar atmosphere studies; the determination of chemical abundances relevant to stellar evolution; the investigation of quasars and Seyfert galaxy nuclei; and the analysis of the atmospheres of solar system objects, including comets.

Brandt, J. C.↗

Large Observatory for X-ray Timing (LOFT-P): A Probe-Class Mission Concept Study

LOFT-P is a mission concept for a NASA Astrophysics Probe-Class (less than $1B) X-ray timing mission, based on the LOFT M-class concept originally proposed to ESA's M3 and M4 calls. LOFT-P requires very large collecting area, high time resolution, good spectral resolution, broadband spectral coverage (2-30 keV), highly flexible scheduling, and an ability to detect and respond promptly to time-critical targets of opportunity. Many of LOFTP's targets are bright, rapidly varying sources, so these measurements are synergistic to imaging and high-resolution spectroscopy instruments, addressing much smaller distance scales than are possible without very long baseline X-ray interferometry, and using complementary techniques to address the geometry and dynamics of emission regions. LOFT-P was presented as an example mission to the head of NASA's Astrophysics Division, to demonstrate the strong community support for creation of a probe-class, for missions costing between $500M and $1B. We submitted a white paper4 in response to NASA PhysPAG's call for white papers: Probe-class Mission Concepts, describing LOFT-P science and a simple extrapolation from the ESA study costs. The next step for probe-class missions will be input into the NASA Astrophysics Decadal Survey to encourage the creation of a probe-class opportunity. We report on a 2016 study by MSFC's Advanced Concepts Office of LOFT-P, a US-led probe-class LOFT concept.

x-ray↗

UWB Tracking System Design for Free-Flyers

This paper discusses an ultra-wideband (UWB) tracking system design effort for Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A tracking algorithm TDOA (Time Difference of Arrival) that operates cooperatively with the UWB system is developed in this research effort. Matlab simulations show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. Lab experiments demonstrate the UWB tracking capability with fine resolution.

Ni, Jianjun↗

Astrophysical applications of high angular resolution array-telescopes

The air shower array-telescopes which are currently being used to search for and study point sources of UHE gamma-rays have angular resolution similar to 1 deg, limited by either the small total area of particle detectors or poor timing resolution. As the signal to noise ratio depends sensitively on the angular resolution, it seems certain that this figure will quickly be surpassed when second generation instruments come into operation. Since the trajectories of galactic cosmic rays with E 100,000 GeV are practically straight lines on scales of 1 A.U. or less, these new instruments will be able to observe a shadow cast by the Moon (angular diameter 0.5 deg). Although the angular diameter of the Sun is practically the same, its shadow will be more complex because of its magnetic field. Thus, high angular resolution observations of the Sun afford a means of investigating the solar magnetic field, and also the charge composition of cosmic rays, including the ratio of antiprotons to protons.

Linsley, J.↗

SGR J1550-5418 Bursts Detected with the Fermi Gamma-Ray Burst Monitor during Its Most Prolific Activity

We have performed detailed temporal and time-integrated spectral analysis of 286 bursts from SGR J1550-5418 detected with the Fermi Gamma-ray Burst Monitor (GBM) in 2009 January, resulting in the largest uniform sample of temporal and spectral properties of SGR J1550-5418 bursts. We have used the combination of broadband and high time-resolution data provided with GBM to perform statistical studies for the source properties.We determine the durations, emission times, duty cycles, and rise times for all bursts, and find that they are typical of SGR bursts. We explore various models in our spectral analysis, and conclude that the spectra of SGR J15505418 bursts in the 8-200 keV band are equally well described by optically thin thermal bremsstrahlung (OTTB), a power law (PL) with an exponential cutoff (Comptonized model), and two blackbody (BB) functions (BB+BB). In the spectral fits with the Comptonized model, we find a mean PL index of -0.92, close to the OTTB index of -1. We show that there is an anti-correlation between the Comptonized E(sub peak) and the burst fluence and average flux. For the BB+BBfits, we find that the fluences and emission areas of the two BB functions are correlated. The low-temperature BB has an emission area comparable to the neutron star surface area, independent of the temperature, while the high temperature BB has a much smaller area and shows an anti-correlation between emission area and temperature.We compare the properties of these bursts with bursts observed from other SGR sources during extreme activations, and discuss the implications of our results in the context of magnetar burst models.

bursts↗

Multifrequency eddy-current detection of fast transient thermal signatures for in situ monitoring applications

Eddy-current (EC) nondestructive evaluation has a long history of use in a variety of ex situ defect monitoring applications because of its exquisite sensitivity to local material variations. Due to the relationship between a material's conductivity and its temperature, EC methods have also been used to investigate quasistatic, long-range temperature variations in casting applications. However, these techniques remain underutilized for the measurement of rapidly varying, spatially nonuniform temperature distributions. In this work, we construct a model system capable of generating repeatable temperature transients in steel plates and measure real-time eddy-current signals with millisecond time resolution and spatial resolution of the order of 1 mm. Using a combination of Multiphysics simulations, fast thermal imaging, and time-resolved holographic interferometry, we tease apart contributions to the eddy-current signals arising from temperature variations and transient plate deformation. Finally, we perform a systematic study in which we vary the plate thickness and the eddy-current excitation frequency to demonstrate that eddy-current techniques can provide information about a three-dimensional, time-varying, subsurface thermal distribution, which is inaccessible to the traditional thermal imaging techniques.

Rosenberg, Ethan R. [Lawrence Livermore National L↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Space and velocity focusing in time-of-flight mass spectrometers

A focusing equation is developed describing the relationship between space and velocity focusing for all one-dimensional time-of-flight mass spectrometers with constant electric fields. As a result of this equation, first-order double time focusing in one dimension is impossible. The possibility of large improvements in the resolving power of the time-of-flight mass spectrometers is discussed on this basis. The focusing equation also leads to an expression for the minimum time resolution obtainable. This second equation is applied to the conventional Wiley and McLaren (1955) two-field time-of-flight mass spectrometer with and without time-lag focusing, and to the mirror instrument of Karataev et al. (1972).

Stein, R.↗

Discovery of radio emission from AE Aquarii

VLA 1.4-GHz and 4.9-GHz observations of six DQ Her cataclysmic variables, obtained in the C/D hybrid configuration with 50-MHz bandwidth, 7-sec time resolution, and limiting flux density about 200 microJy on July 21, 1984, are reported. Variable radio emission with time scale less than 5 min, circular polarization less than 15 percent, and flux density 3-5 mJy at 1.4 GHz and 8-16 mJy at 4.9 GHz is detected from AE Aqr. This emission is tentatively attributed to synchrotron emission from mildly relativistic electrons, powered by the MHD torque coupling the magnetic white dwarf to either (1) a secondary with a strong magnetic field or (2) an accretion disk.

Bookbinder, J. A.↗

Implications of RHESSI Observations for Solar Flare Models and Energetics

Observations of solar flares in X-rays and gamma-rays provide the most direct information about the hottest plasma and energetic electrons and ions accelerated in flares. The Ramaty High Energy Solar Spectroscopic Imager (RHESSI) has observed over 18000 solar flares in X-rays and gamma-rays since its launch in February of 2002. RHESSI observes the full Sun at photon energies from as low as 3 keV to as high as 17 MeV with a spectral resolution on the order of 1 keV. It also provides images in arbitrary bands within this energy range with spatial resolution as good as 3 seconds of arc. Full images are typically produced every 4 seconds, although higher time resolution is possible. This unprecedented combination of spatial, spectral, and temporal resolution, spectral range and flexibility has led to fundamental advances in our understanding of flares. I will show RHESSI and coordinated observations that confirm coronal magnetic reconnection models for eruptive flares and coronal mass ejections, but also present new puzzles for these models. I will demonstrate how the analysis of RHESSI spectra has led to a better determination of the energy flux and total energy in accelerated electrons, and of the energy in the hot, thermal flare plasma. I will discuss how these energies compare with each other and with the energy contained in other flare-related phenomena such as interplanetary particles and coronal mass ejections.

Holman, Gordon D.↗

Equatorial wave activity derived from fluctuations in observed convection

The spectrum of equatorial wave activity propagating vertically into the stratosphere is calculated from high-resolution imagery of the global convective pattern. Synoptic Global Cloud Imagery (GCI), constructed from six satellites simultaneously observing the earth, is used to diabatically force the linearized primitive equations. Having resolution of 0.5 deg and 3 h, that imagery captures the dominant scales of organized convection, including several harmonics of the diurnal cycle. Its global coverage with high space-time resolution allows the GCI to represent heating variability and dynamical behavior excited by it over a wide range of scales. The dynamical response above the heating is evaluated globally in terms of a space-time spectrum of Hough modes, one which includes planetary-scale Kelvin waves, Rossby waves, and gravity waves down to the resolution of the GCI. The geopotential response, which is indicative of temperature fluctuations observed by satellite, is very red in frequency. Therefore, planetary-scale waves with periods longer than two days dominate the spectrum of geopotential, while high-frequency gravity waves make a comparatively small contribution. Some 80% of the geopotential variance is accounted for by the Kelvin and gravest-symmetric Rossby modes, while the Rossby-gravity mode is comparatively weak. In horizontal eddy motion, the excited wave spectrum is still dominated by planetary-scale components. However, meridional wind fluctuations associated with the Rossby-gravity mode have variance comparable to that of zonal wind fluctuations associated with the Kelvin mode, even though the Rossby-gravity mode is nearly invisible in the geopotential response. Estimates of tropospheric heating lead to amplitudes and propagation characteristics that are broadly consistent with satellite and radiosonde observations of wave activity in the lower stratosphere. The space-time spectrum of EP flux is significantly whiter than the response in either geopotential or motion. Gravity waves of small scale and high frequency carry a large fraction of the upward flux. Although it dominates eastward variance of geopotential and motion, the Kelvin mode carries only about 50% of the eastward EP flux at phase speeds of 20-40 m/s and only 35% of the total eastward flux transmitted to the stratosphere. The remainder is carried by the gravity wave spectrum, which carries nearly all of the westward flux at phase speeds greater than 20 m/s. The gravity wave spectrum also contributes significantly at phase speeds of 10-20 m/s, where only 25% of the flux is accounted for by zonal wavenumbers less than 20. The broad nature of the gravity wave spectrum suggests its absorption at critical levels will be distributed over a deep layer of the middle atmosphere.

Bergman, John W.↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗