Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total Dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-F-T-70: A High Dose Rate Total Skin Electron Irradiation Technique with A Specific Inter-Film Variation Correction Method for Very Large Electron Beam Fields

Purpose: Rotational total skin electron irradiation (RTSEI) is used in the treatment of cutaneous T-cell lymphoma. Due to inter-film uniformity variations the dosimetry measurement of a large electron beam of a very low energy is challenging. This work provides a method to improve the accuracy of flatness and symmetry for a very large treatment field of low electron energy used in dual beam RTSEI. Methods: RTSEI is delivered by dual angles field a gantry of ±20 degrees of 270 to cover the upper and the lower halves of the patient body with acceptable beam uniformity. The field size is in the order of 230cm in vertical height and 120 cm in horizontal width and beam energy is a degraded 6 MeV (6 mm of PMMA spoiler). We utilized parallel plate chambers, Gafchromic films and OSLDs as a measuring devices for absolute dose, B-Factor, stationary and rotational percent depth dose and beam uniformity. To reduce inter-film dosimetric variation we introduced a new specific correction method to analyze beam uniformity. This correction method uses some image processing techniques combining film value before and after radiation dose to compensate the inter-variation dose response differences among films. Results: Stationary and rotational depth of dose demonstrated that the Rp is 2 cm for rotational and the maximum dose is shifted toward the surface (3mm). The dosimetry for the phantom showed that dose uniformity reduced to 3.01% for the vertical flatness and 2.35% for horizontal flatness after correction thus achieving better flatness and uniformity. The absolute dose readings of calibrated films after our correction matched with the readings from OSLD. Conclusion: The proposed correction method for Gafchromic films will be a useful tool to correct inter-film dosimetric variation for the future clinical film dosimetry verification in very large fields, allowing the optimizations of other parameters.

60 APPLIED LIFE SCIENCES↗

Radiation induced effects on mechanical properties of nanoporous gold foams

Previously, it was demonstrated that due to a high surface-to-volume ratio, nanoporous materials display radiation tolerance. The abundance of surfaces, which are perfect sinks for defects, and the relation between ligament size, defect diffusion, and time combine to define a window of radiation resistance [Fu et al., Appl. Phys. Lett. 101, 191607 (2012)]. Outside this window, the dominant defect created by irradiation in Au nanofoams are stacking fault tetrahedra (SFT). Molecular dynamics computer simulations of nanopillars, taken as the elemental constituent of foams, predict that SFTs act as dislocation sources inducing softening, in contrast to the usual behavior in bulk materials, where defects are obstacles to dislocation motion, producing hardening. In this work we test that prediction and answer the question whether irradiation actually hardens or softens a nanofam. Ne ion irradiations of gold nanofoams were performed at room temperature for a total dose up to 4 dpa, and their mechanical behavior was measured by nanoindentation. We observe that hardness increases after irradiation, a result that we analyze in terms of the role of SFTs on the deformation mode of foams.

36 MATERIALS SCIENCE↗

Radiation Tolerance Studies of Commercial Strippable Coatings and Fixatives used for Decontamination - 18642

A number of commercially available products, designed for use as strippable coating and fixatives for decontamination purposes, were tested to determine their tolerability to high radiation fields and how they potentially degrade. Each product was cured and exposed to γ-radiation from a Co-60 source, up to a total dose of 500 kGy. Obvious physical colour changes and deformities were detected by visual inspection, and images captured by scanning electron microscope (SEM) showed major differences post-irradiation in some coatings. Other physical changes to the coatings were measured using Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDS); both pre- and post-irradiation. FT-IR suggested that some chemical changes were taking place in the coatings, in particular the C-H bonds and the fingerprint region appeared to be drastically altered in some coatings. EDS data indicated an increase in surface oxygen content as a result of irradiation in the majority of the samples. Additionally, coating samples were subjected to analysis by gas chromatography mass spectrometry (GCMS) in order to determine the evolved gases. The GC-MS results show that short chain hydrocarbons are produced to some degree in all the coatings during irradiation. Finally, three of the best performing coatings were selected and were irradiated using an ion beam, mimicking Pu alpha particles (with energy of around 5.25 MeV). Using the Dalton Cumbrian Facility's 5 MV tandem accelerator, coating samples were irradiated by ∼5.25 MeV He{sup 2+} particles to total dose of approximately 500 kGy. Samples were analysed using SEM, FT-IR, Raman and EDS, as was done for the gamma irradiated samples, allowing a comparison to be made between α-particle and γ-ray damage. Results from the alpha and gamma irradiations showed many similarities for the comparable assessments. A number of spectral changes observed in the FT-IR analysis were consistent across both γ-ray and α-particle irradiated samples. While there were some differences, these may be attributed to the conditions under which the irradiations were carried out. The observed similarities may allow for the inference of alpha degradation by Co-60 gamma irradiation as a more easily accessible method for determining the extent of radiolytic damage. Furthermore, gamma irradiation allows for additional analysis that is currently otherwise not possible to achieve with ion-beam exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alteration of cytokine profiles in mice exposed to chronic low-dose ionizing radiation

While a high-dose of ionizing radiation is generally harmful and causes damage to living organisms, a low-dose of radiation has been shown to be beneficial in a variety of animal models. To understand the basis for the effect of low-dose radiation in vivo, we examined the cellular and immunological changes evoked in mice exposed to low-dose radiation at very low (0.7 mGy/h) and low (3.95 mGy/h) dose rate for the total dose of 0.2 and 2 Gy, respectively. Mice exposed to low-dose radiation, either at very low- or low-dose rate, demonstrated normal range of body weight and complete blood counts. Likewise, the number and percentage of peripheral lymphocyte populations, CD4{sup +} T, CD8{sup +} T, B, or NK cells, stayed unchanged following irradiation. Nonetheless, the sera from these mice exhibited elevated levels of IL-3, IL-4, leptin, MCP-1, MCP-5, MIP-1{alpha}, thrombopoietin, and VEGF along with slight reduction of IL-12p70, IL-13, IL-17, and IFN-{gamma}. This pattern of cytokine release suggests the stimulation of innate immunity facilitating myeloid differentiation and activation while suppressing pro-inflammatory responses and promoting differentiation of naive T cells into T-helper 2, not T-helper 1, types. Collectively, our data highlight the subtle changes of cytokine milieu by chronic low-dose {gamma}-radiation, which may be associated with the functional benefits observed in various experimental models.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Stereotactic Body Radiotherapy for Primary Hepatocellular Carcinoma

Purpose: To evaluate the safety and efficacy of stereotactic body radiotherapy (SBRT) for the treatment of primary hepatocellular carcinoma (HCC). Methods and Materials: From 2005 to 2009, 60 patients with liver-confined HCC were treated with SBRT at the Indiana University Simon Cancer Center: 36 Child-Turcotte-Pugh (CTP) Class A and 24 CTP Class B. The median number of fractions, dose per fraction, and total dose, was 3, 14 Gy, and 44 Gy, respectively, for those with CTP Class A cirrhosis and 5, 8 Gy, and 40 Gy, respectively, for those with CTP Class B. Treatment was delivered via 6 to 12 beams and in nearly all cases was prescribed to the 80% isodose line. The records of all patients were reviewed, and treatment response was scored according to Response Evaluation Criteria in Solid Tumors v1.1. Toxicity was graded according to the Common Terminology Criteria for Adverse Events v4.0. Local control (LC), time to progression (TTP), progression-free survival (PFS), and overall survival (OS) were calculated according to the method of Kaplan and Meier. Results: The median follow-up time was 27 months, and the median tumor diameter was 3.2 cm. The 2-year LC, PFS, and OS were 90%, 48%, and 67%, respectively, with median TTP of 47.8 months. Subsequently, 23 patients underwent transplant, with a median time to transplant of 7 months. There were no {>=}Grade 3 nonhematologic toxicities. Thirteen percent of patients experienced an increase in hematologic/hepatic dysfunction greater than 1 grade, and 20% experienced progression in CTP class within 3 months of treatment. Conclusions: SBRT is a safe, effective, noninvasive option for patients with HCC {<=}6 cm. As such, SBRT should be considered when bridging to transplant or as definitive therapy for those ineligible for transplant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Best practices for predictions of radionuclide activity concentrations and total absorbed dose rates to freshwater organisms exposed to uranium mining/milling

Predictions of radionuclide dose rates to freshwater organisms can be used to evaluate the radiological environmental impacts of releases from uranium mining and milling projects. These predictions help inform decisions on the implementation of mitigation measures. The objective of this study was to identify how dose rate modelling could be improved to reduce uncertainty in predictions to non-human biota. For this purpose, we modelled the activity concentrations of 210 Pb, 210 Po, 226 Ra, 230 Th, and 238 U downstream of uranium mines and mills in northern Saskatchewan, Canada, together with associated weighted absorbed dose rates for a freshwater food chain using measured activity concentrations in water and sediments. Differences in predictions of radionuclide activity concentrations occurred mainly from the different default partition coefficient and concentration ratio values from one model to another and including all or only some 238 U decay daughters in the dose rate assessments. Consequently, we recommend a standardized best-practice approach to calculate weighted absorbed dose rates to freshwater biota whether a facility is at the planning, operating or decommissioned stage. At the initial planning stage, the best-practice approach recommend using conservative site-specific baseline activity concentrations in water, sediments and organisms and predict conservative incremental activity concentrations in these media by selecting concentration ratios based on species similarity and similar water quality conditions to reduce the uncertainty in dose rate calculations. At the operating and decommissioned stages, the best-practice approach recommends relying on measured activity concentrations in water, sediment, fish tissue and wholebody of small organisms to further reduce uncertainty in dose rate estimates. This approach would allow for more realistic but still conservative dose assessments when evaluating impacts from uranium mining projects and making decision on adequate controls of releases.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Impact of total ionizing dose irradiation on electrical property of ferroelectric-gate field-effect transistor

P-type channel metal-ferroelectric-insulator-silicon field-effect transistors (FETs) with a 300 nm thick SrBi{sub 2}Ta{sub 2}O{sub 9} ferroelectric film and a 10 nm thick HfTaO layer on silicon substrate were fabricated and characterized. The prepared FeFETs were then subjected to {sup 60}Co gamma irradiation in steps of three dose levels. Irradiation-induced degradation on electrical characteristics of the fabricated FeFETs was observed after 1 week annealing at room temperature. The possible irradiation-induced degradation mechanisms were discussed and simulated. All the irradiation experiment results indicated that the stability and reliability of the fabricated FeFETs for nonvolatile memory applications will become uncontrollable under strong irradiation dose and/or long irradiation time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of total ionizing dose irradiation on Pt/SrBi{sub 2}Ta{sub 2}O{sub 9}/HfTaO/Si memory capacitors

In this work, metal-ferroelectric-insulator-semiconductor (MFIS) structure capacitors with SrBi{sub 2}Ta{sub 2}O{sub 9} (300 nm) as ferroelectric thin film and HfTaO (6 nm, 8 nm, 10 nm, and 12 nm) as insulating buffer layer were proposed and investigated. The prepared capacitors were fabricated and characterized before radiation and then subjected to {sup 60}Co gamma irradiation in steps of two dose levels. Significant irradiation-induced degradation of the electrical characteristics was observed. The radiation experimental results indicated that stability and reliability of as-fabricated MFIS capacitors for nonvolatile memory applications could become uncontrollable under strong irradiation dose and/or long irradiation time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation defect dynamics in Si at room temperature studied by pulsed ion beams

The evolution of radiation defects after the thermalization of collision cascades often plays the dominant role in the formation of stable radiation disorder in crystalline solids of interest to electronics and nuclear materials applications. Here, we explore a pulsed-ion-beam method to study defect interaction dynamics in Si crystals bombarded at room temperature with 500 keV Ne, Ar, Kr, and Xe ions. The effective time constant of defect interaction is measured directly by studying the dependence of lattice disorder, monitored by ion channeling, on the passive part of the beam duty cycle. The effective defect diffusion length is revealed by the dependence of damage on the active part of the beam duty cycle. Results show that the defect relaxation behavior obeys a second order kinetic process for all the cases studied, with a time constant in the range of ∼4–13 ms and a diffusion length of ∼15–50 nm. Both radiation dynamics parameters (the time constant and diffusion length) are essentially independent of the maximum instantaneous dose rate, total ion dose, and dopant concentration within the ranges studied. However, both the time constant and diffusion length increase with increasing ion mass. This demonstrates that the density of collision cascades influences not only defect production and annealing efficiencies but also the defect interaction dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials

Synchrotron radiation is an innovative tool for the treatment of brain tumors. In the stereotactic synchrotron radiation therapy (SSRT) technique a radiation dose enhancement specific to the tumor is obtained. The tumor is loaded with a high atomic number (Z) element and it is irradiated in stereotactic conditions from several entrance angles. The aim of this work was to assess dosimetric properties of the SSRT for preparing clinical trials at the European Synchrotron Radiation Facility (ESRF). To estimate the possible risks, the doses received by the tumor and healthy tissues in the future clinical conditions have been calculated by using Monte Carlo simulations (PENELOPE code). The dose enhancement factors have been determined for different iodine concentrations in the tumor, several tumor positions, tumor sizes, and different beam sizes. A scheme for the dose escalation in the various phases of the clinical trials has been proposed. The biological equivalent doses and the normalized total doses received by the skull have been calculated in order to assure that the tolerance values are not reached.

61 RADIATION PROTECTION AND DOSIMETRY↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor excursion outside of the gating window, which, for our study group, is mainly caused by baseline shift, i.e., the change in general trend of the motion curve during extended period of treatment time. Conclusions: The dose deviation in PTV and CTV due to target motion is not always negligible in gated SBRT. Although CTVs are covered sufficiently with prescribed dose in most cases, some are on the verge of underdose due to large tumor excursion caused by factors such as baseline shift.

60 APPLIED LIFE SCIENCES↗

WE-D-BRA-05: Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom

Purpose: To test the feasibility of using 3D-printed patient-specific phantoms for intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We created a patient-specific whole-head phantom using a 3D printer. The printer data file was created from high-resolution DICOM computed tomography (CT) images of 3-year old child treated at our institution for medulloblastoma. A custom-modified extruder system was used to create tissue-equivalent materials. For the printing process, the Hounsfield Units from the CT images were converted to proportional volumetric densities. A 5-field IMRT plan was created from the patient CT and delivered to the 3D- phantom. Dose was measured by an ion chamber placed through the eye. The ion chamber was placed at the posterior edge of the planning target volume in a high dose gradient region. CT scans of the patient and 3D-phantom were fused by using commercial treatment planning software (TPS). The patient’s plan was calculated on the phantom CT images. The ion chamber’s active volume was delineated in the TPS; dose per field and total dose were obtained. Measured and calculated doses were compared. Results: The 3D-phantom dimensions and tissue densities were in good agreement with the patient. However, because of a printing error, there was a large discrepancy in the density in the frontal cortex. The calculated and measured treatment plan doses were 1.74 Gy and 1.72 Gy, respectively. For individual fields, the absolute dose difference between measured and calculated values was on average 3.50%. Conclusion: This study demonstrated the feasibility of using 3D-printed patient-specific phantoms for IMRT QA. Such phantoms would be particularly advantageous for complex IMRT treatment plans featuring high dose gradients and/or for anatomical sites with high variation in tissue densities. Our preliminary findings are promising. We anticipate that, once the printing process is further refined, the agreement between measured and calculated doses will improve.

60 APPLIED LIFE SCIENCES↗