Search NASA⌕ Search

SEARCH · Search NASA

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The development of a microprocessor-controlled linearly-actuated valve assembly

The development of a proportional fluid control valve assembly is presented. This electromechanical system is needed for space applications to replace the current proportional flow controllers. The flow is controlled by a microprocessor system that monitors the control parameters of upstream pressure and requested volumetric flow rate. The microprocessor achieves the proper valve stem displacement by means of a digital linear actuator. A linear displacement sensor is used to measure the valve stem position. This displacement is monitored by the microprocessor system as a feedback signal to close the control loop. With an upstream pressure between 15 and 47 psig, the developed system operates between 779 standard CU cm/sec (SCCS) and 1543 SCCS.

Wall, R. H.↗

Precise-Conductance Valve Insert

Valve modification provides two operating modes fully open and small, precise leak. Copper insert with radially oriented holes allows small, controllable, precise effusion rate when valve closed or nearly unobstructed flow when valve open. Numerous applications in surface physics, vacuum physics, materials science, gas kinetics, thin films, and other areas of research requiring measured flows of gas into or out of system.

Outlaw, R. A.↗

Dual-Flow-Rate Valve

Flow-control device precisely adjusted for two rates. Heart of twoposition valve is sliding poppet. At far-right position, poppet allows low flow. At far-left position, allows high flow. Valve supplies high-pressure gas at either of two preselected flow rates. Valve adjustable between 0.12 and 1.2 lb/s (0.054 and 0.54 kg/s) of hydrogen at 3,300 lb/in.2 (23 MN/m2) and 80 degrees F (27 degrees C). Two flow rates preadjusted between these limits in increments of 0.01 lb/s (0.0045 kg/s).

Allbritain, R. H.↗

Relief Valve Opens And Closes Quickly

Relief valve opens quickly to relieve excess pressure and closes quickly when pressure drops slightly below relief pressure. O-ring exposes one or more ports under high pressure, releasing excess pressurized fluid. Adjusting screw used to change compression on Belleville-spring washers and to set pressure at which valve opens. Designed for use aboard Space Shuttle to vent pressurized hydrazine to vacuum, valve concept useful in industrial applications where rapid opening, rapid closing, or low susceptibility to blockage by vented fluid required.

Svejkovsky, Paul A.↗

Rotary-To-Axial Motion Converter For Valve

Nearly frictionless mechanism converts rotary motion into axial motion. Designed for use in electronically variable pressure-regulator valve. Changes rotary motion imparted by motor into translation that opens and closes valve poppet. Cables spaced equidistantly around edge of fixed disk support movable disk. As movable disk rotated, cables twist, lifting it. When rotated in opposite direction, cables untwist, lowering it. Spider disk helps to prevent cables from tangling. Requires no lubrication and insensitive to contamination in fluid flowing through valve.

Reinicke, Robert H.↗

Lock For Valve Stem

Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.

Burley, Richard K.↗

Lightweight Valve Closes Duct Quickly

Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.

Fournier, Walter L.↗

Valve for waste collection and storage

A method and valve apparatus for collection of fecal matter designed to operate efficiently in a zero gravity environment is presented. The system comprises a waste collection area within a body having a seat opening. Low pressure within the waste collection area directs fecal matter away from the user's buttocks and prevents the escape of undersirable gases. The user actuates a piston covered with an absorbent pad that sweeps through the waste collection area to collect the fecal matter, scrub the waste collection area, press the waste against an end of the waste collection area and retracts, leaving the used pad. Multiple pads are provided on the piston to accommodate multiple uses of the system. Also a valve allows air to be drawn through the body, so the valve will not be plugged with fecal matter. A sheet feeder feeds fresh sheets of absorbent pads to a face of the piston with each actuation.

Thornton, William E., Jr.↗

Mathematical model of the Space Shuttle Main Engine gaseous oxygen control valve

A computer program for modeling transient flow behavior of the GOX control valve (GCV) has been developed which makes it possible to model a variety of operating conditions and changes of physical hardware. The SSME GCV controls the flow of GOX that pressurizes the Pogo accumulator. The model simulates the transient flow behavior of the original, tight stacked, and redesigned valve configurations during start and shutdown. The model reads a user-prepared input file that defines the valve configurations and thus provides maximum flexibility.

Langer, Susan L.↗

Disk Valve For Cryogenics

Lightweight disk valve designed to have dimensions and capabilities similar to those of valve described in "Lightweight Right-Angle Valve For Cryogenics" (MSC-21889). Simple unit remains leaktight over wide range of pressures and temperatures without need for manual readjustment of packing gland. Weighs less than 60 g and made relatively inexpensively from some commercial and few simple custom-machined components.

Calhoun, Richard B.↗

Development of an iron nitrate resistant injector valve for the Space Shuttle orbiter primary thruster

Design of a direct-acting valve (DAV) for a primary thruster which is fully interchangeable with a thruster equipped with pilot-operated valves is described. The DAV is based on a bellows to isolate propellants form the actuator for maximum resistance to iron nitrate and other contamination and to select optimum materials for the actuator. It provides improved seal performance under all operating conditions and insensitivity to pressure transients. As compared with the existing pilot-operated valve, the DAV design is much simpler, consists of fewer parts, and will be lower in cost.

Wichmann, Horst↗

Developmental testing resulting in a simplified liquid oxygen check valve for the Space Shuttle Main Propulsion System

The coil spring in a Space Shuttle liquid oxygen check valve failed due to cyclic fatigue in September, 1991. The dual-flapper, swing check valve is used to prevent reverse flow to the Space Shuttle Main Engines. Upon inspection of the failed component, the spring tangs were found to be missing and heavy wear was observed on the inner diameter of the spring coils. The fracture surfaces revealed that the metal had been steadily worn away until a simple overload caused the final fracture. A series of flow tests using water and a water/gas mixture was conducted to identify the flow phenomenon which produced the cyclic wear. A Plexiglas outlet housing was utilized to view the flapper behavior under different flow conditions and to aid in high speed photography. The tests revealed that flow instabilities induced two oscillatory flapper responses: a rocking mode and a chattering mode. Initially, attempts were made to reduce the spring-flapper oscillations. However, the final solution to the problem was a springless configuration which satisfied the valve's design requirements and eliminated the oscillations. The springless design relied on the inherent ability of the reverse flow momentum to close the flappers.

Aber, Gregory S.↗

The N.A.C.A. Combustion Chamber Gas-sampling Valve and Some Preliminary Test Results

A gas sampling valve of the inertia-operated type was designed for procuring samples of the gases in the combustion chamber of internal combustion engines at identical points in successive cycles so that the analysis of the gas samples thus procured may aid in the study of the process of combustion. The operation of the valve is described. The valve was used to investigate the CO2 content of gases taken from the quiescent combustion chamber of a high speed compression-ignition engine when operating with two different multiple-orifice fuel injection nozzles. An analysis of the gas samples thus obtained shows that the state of quiescence in the combustion chamber is maintained during the combustion of the fuel.

Spanogle, J A↗

The N.A.C.A. Photographic Apparatus for Studying Fuel Sprays from Oil Engine Injection Valves and Test Results from Several Researches

Apparatus for recording photographically the start, growth, and cut-off of oil sprays from injection valves has been developed at the Langley Memorial Aeronautical Laboratory. The apparatus consists of a high-tension transformer by means of which a bank of condensers is charged to a high voltage. The controlled discharge of these condensers in sequence, at a rate of several thousand per second, produces electric sparks of sufficient intensity to illuminate the moving spray for photographing. The sprays are injected from various types of valves into a chamber containing gases at pressures up to 600 pounds per square inch. Several series of pictures are shown. The results give the effects of injection pressure, chamber pressure, specific gravity of the fuel oil used, and injection-valve design, upon spray characteristics.

Beardsley, Edward G↗

The Design and Development of an Automatic Injection Valve with an Annular Orifice of Varying Area

The purpose of this investigation was to provide an automatic injection valve of simple construction which would produce a finely atomized oil spray of broad cone angle and would fulfill the requirements of fuel injection in aircraft oil engines. The injection valve designed has only six parts - i. e., two concentric nozzle tubes flared at one end, two body parts, and two nuts. Analysis and engine tests indicate that the fuel spray from this type of injection valve has characteristics which reduce the time lag of autoignition and promote efficient combustion in high-speed oil engines.

Joachim, William F↗

The Effect of Valve Timing Upon the Performance of a Supercharged Engine at Altitude and an Unsupercharged Engine at Sea Level

This investigation was conducted to determine the comparative effects of valve timing on the performance of an unsupercharged engine at sea level and a supercharged engine at altitude. The tests were conducted on the NACA universal test engine. The timing of the four valve events was varied over a wide range; the engine speeds were varied between 1,050 and 1,500 r.p.m.; the compression ratios were varied between 4.35:1 and 7.35:1. The conditions of exhaust pressure and carburetor pressure of a supercharged engine were simulated for altitudes between 0 and 18,000 feet. The results show that optimum valve timing for a supercharged engine at an altitude of 18,000 feet differs slightly from that for an unsupercharged engine at sea level. A small increase in power is obtained by using the optimum timing for 18,000 feet for altitudes above 5,000 feet. The timing of the intake opening and exhaust closing becomes more critical as the compression ratio is increased.

Schey, Oscar W↗

Flow coefficients of monosleeve valves

The flow coefficients of the intake and the exhaust ports of a sleeve-valve cylinder were measured by attaching the cylinder to a large tank and measuring the changes in pressure and temperature in the tank that were caused by short periods of air flow through the valve ports. The derivation of the equations on which the flow coefficients are based is given. The distribution of total pressure in the arms of the sleeve-valve intake manifold was measured. The arms are found to have as little as 75 percent of the total pressure within the manifold entrance.

Waldron, C D↗

Valve-spring Surge

Test equipment is described that includes a system of three quartz indicators whereby three different pressures could be synchronized and simultaneously recorded on a single oscillogram. This equipment was used to test the reliction of waves at ends of valve spring, the dynamical stress of the valve spring for a single lift of the valve, and measurement of the curve of the cam tested. Other tests included simultaneous recording of the stress at both ends of the spring, spring oscillation during a single lift as a function of speed, computation of amplitude of oscillation for a single lift by harmonic analysis, effect of cam profile, the setting up of resonance, and forced spring oscillation with damping.

Marti, Willy↗