Search NASA⌕ Search

SEARCH · Search NASA

Results for “XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

On the Sn loss from thin films of the material system Cu-Zn-Sn-S in high vacuum

In this paper the Sn loss from thin films of the material system Cu-Zn-Sn-S and the subsystems Cu-Sn-S and Sn-S in high vacuum is investigated. A combination of in situ x-ray diffractometry and x-ray fluorescence (XRF) at a synchrotron light source allowed identifying phases, which tend to decompose and evaporate a Sn-containing compound. On the basis of the XRF results a quantification of the Sn loss from the films during annealing experiments is presented. It can be shown that the evaporation rate from the different phases decreases according to the order SnS{yields}Cu{sub 2}SnS{sub 3}{yields}Cu{sub 4}SnS{sub 4}{yields}Cu{sub 2}ZnSnS{sub 4}. The phase SnS is assigned as the evaporating compound. The influence of an additional inert gas component on the Sn loss and on the formation of Cu{sub 2}ZnSnS{sub 4} thin films is discussed.

36 MATERIALS SCIENCE↗

Improved micro x-ray fluorescence spectrometer for light element analysis

Since most available micro x-ray fluorescence (micro-XRF) spectrometers operate in air, which does not allow the analysis of low-Z elements (Z{<=}14), a special micro-XRF spectrometer has been designed to extend the analytical range down to light elements (Z{>=}6). It offers improved excitation and detection conditions necessary for light element analysis. To eliminate absorption of the exciting and fluorescent radiation, the system operates under vacuum condition. Sample mapping is automated and controlled by specialized computer software developed for this spectrometer. Several different samples were measured to test and characterize the spectrometer. The spot size has been determined by scans across a 10 {mu}m Cu wire which resulted in a full width at half maximum of 31 {mu}m for Mo K{alpha} line (17.44 keV) and 44 {mu}m effective beam size for the Cu K edge and 71 {mu}m effective beam size for the Cu L edge. Lower limits of detection in the picogram range for each spot (or {mu}g/cm{sup 2}) were obtained by measuring various thin metal foils under different conditions. Furthermore, detection limits in the parts per million range were found measuring NIST621 standard reference material. Area scans of a microscopic laser print and NaF droplet were performed to show mapping capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Archaeometrical studies using X-ray fluorescence methods

Elemental analysis contributes to authentication (knowing the elemental composition and considering the information about the usual composition of the objects in different historical periods it can be established if the item is original or fake), provenance studies (minor and trace elements indicates ores origin and 'consequently' mines location), (relative) dating of archaeological objects (e.g. for painted items--the chemical recipes for pigments can offer information about the age of objects). The paper gives a general layout for the NIPNE Archaeometry Laboratory's applications using X-Ray Fluorescence (XRF), micro--Proton Induced X-Ray Emission (micro-PIXE), micro-Synchrotron Radiation Induced X-Ray Fluorescence (micro--SR-XRF) methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Synchrotron Based X-ray Fluorescence and Scattering Measurements During Atomic Layer Deposition: Initial Growth of HfO2 on Si and Ge Substrates

The initial growth of HfO{sub 2} was studied by means of synchrotron based in situ x-ray fluorescence (XRF) and grazing incidence small angle x-ray scattering (GISAXS). HfO{sub 2} was deposited by atomic layer deposition (ALD) using tetrakis(ethylmethylamino)hafnium and H{sub 2}O on both oxidized and H-terminated Si and Ge surfaces. XRF quantifies the amount of deposited material during each ALD cycle and shows an inhibition period on H-terminated substrates. No inhibition period is observed on oxidized substrates. The evolution of film roughness was monitored using GISAXS. A correlation is found between the inhibition period and the onset of surface roughness.

36 MATERIALS SCIENCE↗

An in situ approach to study trace element partitioning in the laser heated diamond anvil cell

Data on partitioning behavior of elements between different phases at in situ conditions are crucial for the understanding of element mobility especially for geochemical studies. Here, we present results of in situ partitioning of trace elements (Zr, Pd, and Ru) between silicate and iron melts, up to 50 GPa and 4200 K, using a modified laser heated diamond anvil cell (DAC). This new experimental set up allows simultaneous collection of x-ray fluorescence (XRF) and x-ray diffraction (XRD) data as a function of time using the high pressure beamline ID27 (ESRF, France). The technique enables the simultaneous detection of sample melting based to the appearance of diffuse scattering in the XRD pattern, characteristic of the structure factor of liquids, and measurements of elemental partitioning of the sample using XRF, before, during and after laser heating in the DAC. We were able to detect elements concentrations as low as a few ppm level (2-5 ppm) on standard solutions. In situ measurements are complimented by mapping of the chemical partitions of the trace elements after laser heating on the quenched samples to constrain the partitioning data. Our first results indicate a strong partitioning of Pd and Ru into the metallic phase, while Zr remains clearly incompatible with iron. This novel approach extends the pressure and temperature range of partitioning experiments derived from quenched samples from the large volume presses and could bring new insight to the early history of Earth.

36 MATERIALS SCIENCE↗

Neural induced embryoid bodies present high levels of metals detected by x-ray microfluorescence

Molecular mechanisms driving neural differentiation in human embryonic stem cells are not completely elucidated, specially, the role of atomic elements within this process. In this work, we described the distribution of trace elements in those stem cells growing as embryoid bodies by using synchrotron radiation X-ray microfluorescence (SR-XRF). Naive and neural induced embryoid bodies derived from embryonic stem cells were irradiated with a spatial resolution of 20 {mu}m to make elemental maps and qualitative chemical analyses. We consistently detected metallic elements content raise on neural induced embryoid bodies, mimicking characteristic brain development. The use of SR-XRF reveals that human embryoid bodies exhibit self-organization at the atomic level, which is enhanced during neurogenesis triggered in vitro.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real time x-ray studies during nanostructure formation on silicon via low energy ion beam irradiation using ultrathin iron films

Real time grazing incidence small angle x-ray scattering and x-ray fluorescence (XRF) are used to elucidate nanodot formation on silicon surfaces during low energy ion beam irradiation of ultrathin iron-coated silicon substrates. Four surface modification stages were identified: (1) surface roughening due to film erosion, (2) surface smoothing and silicon-iron mixing, (3) structure formation, and (4) structure smoothing. The results conclude that 2.5 Multiplication-Sign 10{sup 15} iron atoms in a 50 nm depth triggers surface nanopatterning with a correlated nanodots distance of 25 nm. Moreover, there is a wide window in time where the surface can have correlated nanostructures even after the removal of all the iron atoms from the sample as confirmed by XRF and ex-situ x-ray photoelectron spectroscopy (XPS). In addition, in-situ XPS results indicated silicide formation, which plays a role in the structure formation mechanism.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

36 MATERIALS SCIENCE↗

Synthesis and characterization of NiO nanopowder by sol-gel process

Preparation of nickel oxide (NiO) nanopowder by sol-gel process has been studied. NiO nanopowders were obtained by sol-gel method by using nickel nitrate hexahydrate and sodium hydroxide and aquadest were used as precursor, agent precipitator and solvent, respectively. The powders were formed by drying at 110°C and followed by heating in the furnace at 400°C for 1.5 hours. The product was obtained black powder. The product was characterized by Energy Dispesive X-ray Fluorescence (ED-XRF), X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM). The ED-XRF pattern shows the composition of NiO produced was 97.1%. The XRD pattern showed NiO forms were produced generally in monoclinic stucture. The crystalline size of NiO was obtained in the range 40-85 nm. SEM micrograph clearly showed that powder had a spherical with uniform distribution size is 0.1-1.0 µm approximately.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detector or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.

07 ISOTOPE AND RADIATION SOURCES↗

Molecular and structural properties of polymer composites filled with activated charcoal particles

We have studied the molecular properties, structural properties, and chemical composition of composites by Fourier transform infrared (FTIR) spectroscopy, X-ray diffraction (XRD) spectroscopy, and X-ray fluorescence (XRF) spectroscopy, respectively. FTIR spectra shows absorption band of hydroxyl group (-OH), methyl group (-CH{sub 3}) and aromatic group (C-C). The absorption band for aromatic group (C-C) shows the formation of carbonaceous in composites. XRF shows chemical composition of composites, which the main chemicals are SO{sub 3}, Cl, and ZnO. The loss on ignition value (LOI) of activated charcoal indicates high carbonaceous matter. The crystallite size for diffraction pattern from hydrogel polymer is about 17 nm and for activated charcoal are about 19 nm. The crystallite size of the polymer is lower than that of activated charcoal, which make possible of the particle from filler in contact with each other to form continuous conducting polymer through polymer matrix.

36 MATERIALS SCIENCE↗

Study of chloride ion transport of composite by using cement and starch as a binder

This study presents the chemical bonding and the structural properties of composites from accelerator chloride test migration (ACTM). The volume fractions between binder (cement and starch) and charcoal in composites are 20:80 and 60:40. The effect of the binder to the chemical composition, chemical bonding, and structural properties before and after chloride ion passing through the composites was determined by X-ray fluorescence (XRF), by Fourier transform infra-red (FTIR), and x-ray diffraction (XRD), respectively. From the XRD data, XRF data, and the FTIR data shows the amount of chemical composition, the type of binding, and the structure of composites are depending on the type of binder. The amount of chloride migration using starch as binder is higher than that of cement as a binder due to the density effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron-based investigation of transition-metal getterability in n-type multicrystalline silicon

Solar cells based on n-type multicrystalline silicon (mc-Si) wafers are a promising path to reduce the cost per kWh of photovoltaics; however, the full potential of the material and how to optimally process it are still unknown. Process optimization requires knowledge of the response of the metal-silicide precipitate distribution to processing, which has yet to be directly measured and quantified. To supply this missing piece, we use synchrotron-based micro-X-ray fluorescence (μ-XRF) to quantitatively map >250 metal-rich particles in n-type mc-Si wafers before and after phosphorus diffusion gettering (PDG). We find that 820°C PDG is sufficient to remove precipitates of fast-diffusing impurities and that 920°C PDG can eliminate precipitated Fe to below the detection limit of μ-XRF. Thus, the evolution of precipitated metal impurities during PDG is observed to be similar for n- and p-type mc-Si, an observation consistent with calculations of the driving forces for precipitate dissolution and segregation gettering. Measurements show that minority-carrier lifetime increases with increasing precipitate dissolution from 820°C to 880°C PDG, and that the lifetime after PDG at 920°C is between the lifetimes achieved after 820°C and 880°C PDG.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterisation of silica derived from rice husk (Muar, Johor, Malaysia) decomposition at different temperatures

Rice husk was thermally decomposed to yield powder composed of silica (SiO{sub 2}). Temperatures of 700°C and 1000°C were chosen as the decomposition temperatures. X-Ray Diffraction (XRD), X-Ray Florescence (XRF), Fourier Transform Infrared (FTIR), and Field Emission Scanning Electron Microscope (FESEM) analyses were conducted on a synthetic silica powder (SS-SiO{sub 2}) and the rice husk ash as for the comparative characterisation study. XRD analyses clearly indicated that the decomposed rice husk yielded silica of different nature which are Crystalline Rice Husk Silica (C-RHSiO{sub 2}) and Amorphous Rice Husk Silica (A-RHSiO{sub 2}). Moreover, it was found that SS-SiO{sub 2} was of Quartz phase, C-RHSiO{sub 2} was of Trydimite and Cristobalite. Through XRF detection, the highest SiO{sub 2} purity was detected in SS-SiO{sub 2} followed by C-RHSiO{sub 2} and A-RHSiO{sub 2} with purity percentages of 99.60%, 82.30% and 86.30% respectively. FTIR results clearly indicated silica (SiO{sub 2}) bonding 1056, 1064, 1047, 777, 790 and 798 cm{sup −1}) increased as the crystallinity silica increased. The Cristobalite phase was detected in C-RH SiO{sub 2} at the wavelength of 620 cm{sup −1}. Morphological features as observed by FESEM analyses confirmed that, SS-SiO{sub 2} and C-RH SiO{sub 2} showed prominent coarse granular morphology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and composition control of epitaxial FeWO4 thin films using pulsed laser deposition

We report the growth of epitaxial FeWO4 thin films on c-plane sapphire via pulsed laser deposition using a Fe 2 O 3 /WO 3 target ablated in an O 2 atmosphere. At a constant O 2 pressure of 1 mTorr, x-ray diffraction (XRD) confirms FeWO 4 as the major crystalline phase for substrate temperatures from 500 to 800 °C. As temperature increases, x-ray fluorescence (XRF) shows the Fe/W ratio remains nearly constant at 0.90 ± 0.02, while x-ray photoelectron spectroscopy (XPS) shows Fe 3+ to Fe 2+ conversion increases from 20% to 35%. Morphological analysis reveals phase separation, likely of amorphous Fe 3+ oxide from crystalline FeWO 4 , increasing with Fe 3+ conversion. This is attributed to an O-rich laser ablated flux, where conversion is driven by the Arrhenius temperature dependence of Fe 3+ → Fe 2+ reduction on the film surface. At a constant substrate temperature of 750 °C, XRD confirms FeWO 4 formation for O 2 pressures from 0.5 to 10 mTorr. As pressure increases, XRF shows the Fe/W ratio decreases from 0.98 to 0.70, while XPS shows Fe 3+ conversion rises from 15% to 70%. Morphology shows phase separation decreasing with increasing Fe 3+ conversion. This is attributed to scattering, where higher O 2 pressure makes the laser ablated flux O-deficient relative to Fe and W, facilitating Fe 2+ formation. Films with Fe 3+ conversion above ∼30% and Fe/W ratios from 0.86 to 0.96 exhibit FeWO 4 optical and electronic properties suitable for photoanode applications.

36 MATERIALS SCIENCE↗

THE EARLY ASYMMETRIES OF SUPERNOVA 2008D/XRF 080109

Spectropolarimetry of the Type Ib SN 2008D, associated with the X-ray Flash (XRF) 080109, at two separate epochs, is presented. The epochs of these observations correspond to V-band light curve maximum and 15 days after light curve maximum (or 21 and 36 days after the XRF). We find SN 2008D to be significantly polarized, although the largest contribution is due to the interstellar polarization component of Q {sub ISP} = 0% +- 0.1% and U {sub ISP} = -1.2% +- 0.1%. At the two epochs, the spectropolarimetry of SN 2008D is classified as being D1+L(He I)+L(Ca II). The intrinsic polarization of continuum wavelength regions is <0.4%, at both epochs, implying an asymmetry of the photosphere of <10%. Similar to other Type Ibc SNe, such as 2005bf, 2006aj, and 2007gr, we observed significant polarization corresponding to the spectral features of Ca II, He I, Mg I, Fe II and, possibly, O I lambda7774, about a close-to-spherically symmetric photosphere. We introduce a new plot showing the chemically distinct line-forming regions in the ejecta and comment on the apparent ubiquity of highly polarized high-velocity Ca II features in Type Ibc SNe. The polarization angle of Ca II IR triplet was significantly different, at both epochs, to those of the other species, suggesting high-velocity Ca II forms in a separate part of the ejecta. The apparent structure in the outer layers of SN 2008D has implications for the interpretation of the early-time X-ray emission associated with shock breakout. We present two scenarios, within the jet-torus paradigm, which explain the lack of an apparent geometry discontinuity between the two observations: (1) a jet which punched a hole straight through the progenitor and deposited Ni outside the ejecta and (2) a jet which stalled inside the radius of the photosphere as observed at the second epoch. The lack of a peculiar polarization signature, suggesting strongly asymmetric excitation of the ejecta, and the reported properties of the shock-breakout favor the second scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

Multimodal X-ray nano-spectromicroscopy analysis of chemically heterogeneous systems

Abstract Understanding the nanoscale chemical speciation of heterogeneous systems in their native environment is critical for several disciplines such as life and environmental sciences, biogeochemistry, and materials science. Synchrotron-based X-ray spectromicroscopy tools are widely used to understand the chemistry and morphology of complex material systems owing to their high penetration depth and sensitivity. The multidimensional (4D+) structure of spectromicroscopy data poses visualization and data-reduction challenges. This paper reports the strategies for the visualization and analysis of spectromicroscopy data. We created a new graphical user interface and data analysis platform named XMIDAS (X-ray multimodal image data analysis software) to visualize spectromicroscopy data from both image and spectrum representations. The interactive data analysis toolkit combined conventional analysis methods with well-established machine learning classification algorithms (e.g. nonnegative matrix factorization) for data reduction. The data visualization and analysis methodologies were then defined and optimized using a model particle aggregate with known chemical composition. Nanoprobe-based X-ray fluorescence (nano-XRF) and X-ray absorption near edge structure (nano-XANES) spectromicroscopy techniques were used to probe elemental and chemical state information of the aggregate sample. We illustrated the complete chemical speciation methodology of the model particle by using XMIDAS. Next, we demonstrated the application of this approach in detecting and characterizing nanoparticles associated with alveolar macrophages. Our multimodal approach combining nano-XRF, nano-XANES, and differential phase-contrast imaging efficiently visualizes the chemistry of localized nanostructure with the morphology. We believe that the optimized data-reduction strategies and tool development will facilitate the analysis of complex biological and environmental samples using X-ray spectromicroscopy techniques.

36 MATERIALS SCIENCE↗