Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Self-Similar Multimode Bubble-Front Evolution of the Ablative Rayleigh-Taylor Instability in Two and Three Dimensions

Here, the self-similar nonlinear evolution of the multimode ablative Rayleigh-Taylor instability (ARTI) is studied numerically in both two and three dimensions. It is shown that the nonlinear multimode bubble-front penetration follows the α b A T (∫√gdt) 2 scaling law with α b dependent on the initial conditions and ablation velocity. The value of α b is determined by the bubble competition theory, indicating that mass ablation reduces α b with respect to the classical value for the same initial perturbation amplitude. It is also shown that ablation-driven vorticity accelerates the bubble velocity and prevents the transition from the bubble competition to the bubble merger regime at large initial amplitudes leading to higher α b than in the classical case. Because of the dependence of α b on initial perturbation and vorticity generation, ablative stabilization of the nonlinear ARTI is not as effective as previously anticipated for large initial perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Outer shell symmetry for double shell capsules with aluminum ablators

Double shell targets are a promising potential avenue to obtain robust neutron yield at current laser facilities. Similar to single shell designs, double shells require the symmetric implosion of an ablator in order to uniformly compress and heat a fuel volume, with the goal of achieving thermonuclear burn. Significant differences between double and single shells include the usage of an aluminum ablator as well as a reverse ramp laser pulse. In addition, double shells require a different convergence than single shells for fuel ignition. Numerical implosion studies at various energies with comparisons to experimental outcomes are required to gain confidence that simulations can capture the ablator shape from subscale to full scale. The current work builds on previous implosion experiments conducted at 1-MJ laser energy to con firm achieved ablator symmetry at 1.25 and 1.5 MJ. Average ablator P2 and P4 shapes measured in these experiments are within 5% of the simulated shape, which merits the platforms for further experimental studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solvent Influence on the Magnetization and Phase of Fe-Ni Alloy Nanoparticles Generated by Laser Ablation in Liquids

The synthesis of bimetallic iron-nickel nanoparticles with control over the synthesized phases, particle size, surface chemistry, and oxidation level remains a challenge that limits the application of these nanoparticles. Pulsed laser ablation in liquid allows the properties tuning of the generated nanoparticles by changing the ablation solvent. Organic solvents such as acetone can minimize nanoparticle oxidation. Yet, economical laboratory and technical grade solvents that allow cost-effective production of FeNi nanoparticles contain water impurities, which are a potential source of oxidation. Here, we investigated the influence of water impurities in acetone on the properties of FeNi nanoparticles generated by pulsed laser ablation in liquids. To remove water impurities and produce “dried acetone”, cost-effective and reusable molecular sieves (3 Å) are employed. The results show that the Fe50Ni50 nanoparticles’ properties are influenced by the water content of the solvent. The metastable HCP FeNi phase is found in NPs prepared in acetone, while only the FCC phase is observed in NPs formed in water. Mössbauer spectroscopy revealed that the FeNi nanoparticles oxidation in dried acetone is reduced by 8% compared to acetone. The high-field magnetization of Fe50Ni50 nanoparticles in water is the highest, 68 Am2/kg, followed by the nanoparticles obtained after ablation in acetone without water impurities, 59 Am2/kg, and acetone, 52 Am2/kg. The core-shell structures formed in these three liquids are also distinctive, demonstrating that a core-shell structure with an outer oxide layer is formed in water, while carbon external layers are obtained in acetone without water impurity. The results confirm that the size, structure, phase, and oxidation of FeNi nanoparticles produced by pulsed laser ablation in liquids can be modified by changing the solvent or just reducing the water impurities in the organic solvent.

36 MATERIALS SCIENCE↗

Comparison of ablators for the polar direct drive exploding pusher platform

We examine the performance of pure boron, boron carbide, high density carbon, and boron nitride ablators in the polar direct drive exploding pusher (PDXP) platform. The platform uses the polar direct drive conguration at the National Ignition Facility to drive high ion temperatures in a room temperature capsule and has potential applications for plasma physics studies and as a neutron source. The higher tensile strength of these materials compared to plastic enables a thinner ablator to support higher gas pressures, which could help optimize its performance for plasma physics experiments, while ablators containing boron enable the possiblity of collecting addtional data to constrain models of the platform. Applying recently developed and experimentally validated equation of state models for the boron materials, we examine the performance of these materials as ablators in 2D simulations, with particular focus on changes to the ablator and gas areal density, as well as the predicted symmetry of the inherently 2D implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plume collimation for laser ablation electrospray ionization mass spectrometry

In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

47 OTHER INSTRUMENTATION↗

Plume collimation for laser ablation electrospray ionization mass spectrometry

In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

47 OTHER INSTRUMENTATION↗

Synthesis of Mg(OH)2, MgO, and Mg nanoparticles using laser ablation of magnesium in water and solvents

laser ablation of magnesium in deionized water (OW), solutions of OW and sodium dodecyl sulfate (50S) with different concentrations, acetone and 2-propanol has been conducted, The results showed that ablation in acetone and 2-propanol yielded MgO and Mg nanocrystallites as isolated particles and agglomerated chains probably intermixed with organic residues resulting from the alterationj decomposition of the solvents under the high-energy conditions. Brucite-like Mg(OH)2 particles were mainly produced by laser ablation of Mg in either OW or OW~SOS solutions. Ablation in OW yielded particles of fiber-like shapes having a diameter of about 5-lOnm and length as long as 150nm. Materials produced in DW-SOS solutions were composed of various size and shape particles, Some had rough surfaces with irregular shapes. Small particles were about 20-30nm and larger particles were about 120 nm. Particles with rod-like, triangular, and plate-like shapes were also observed.

36 MATERIALS SCIENCE↗

Radiofrequency Ablation of Renal Tumors with an Expandable Multitined Electrode: Results, Complications, and Pilot Evaluation of Cooled Pyeloperfusion for Collecting System Protection

The objective of this study was to retrospectively evaluate the results of radiofrequency ablation (RFA) of renal tumors with an impedance-based system using an expandable multitined electrode. Twenty-two patients (30 tumors) were treated with RFA over a 7-year period, percutaneously (16 tumors) or intraoperatively (14 tumors). Follow-up imaging was performed at 1-3, 6, and 12 months and yearly thereafter. Twenty-seven of 30 tumors (19/22 patients) showed no residual tumor on the first imaging control. Two residual tumors were successfully ablated by a second RFA procedure. Our mean follow-up period was 35 months (range, 3-84 months). Two tumors that had been completely ablated based on imaging criteria recurred 11 and 48 months after RFA. One was treated by partial nephrectomy. The other one was not treated because the patient developed bone metastases. One patient had nephrectomy because of an RFA-induced ureteropelvic junction stricture. Nine patients (11 sessions) had a pyeloperfusion of cooled saline during RFA. None developed symptomatic complications, even though in three patients the ablation zone extended to the closest calyx (3-5 mm from the tumor). We conclude that RFA of renal tumors is promising, but serious complications to the collecting system must be taken into consideration. Prophylactic per-procedural cooling of the collecting system is feasible but needs further assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Radiofrequency Ablation in Patients with Hepatic Metastases from Breast Cancer

The purpose of this study was to evaluate technical success, technique effectiveness, and survival following radiofrequency ablation for breast cancer liver metastases and to determine prognostic factors. Forty-three patients with 111 breast cancer liver metastases underwent CT-guided percutaneous radiofrequency (RF) ablation. Technical success and technique effectiveness was evaluated by performing serial CT scans. We assessed the prognostic value of hormone receptor status, overexpression of human epidermal growth factor receptor 2 (HER2), and presence of extrahepatic tumor spread. Survival rates were calculated using the Kaplan-Meier method. Technical success was achieved in 107 metastases (96%). Primary technique effectiveness was 96%. During follow-up local tumor progression was observed in 15 metastases, representing a secondary technique effectiveness of 86.5%. The overall time to progression to the liver was 10.5 months. The estimated overall median survival was 58.6 months. There was no significant difference in terms of survival probability with respect to hormone receptor status, HER2 overexpression, and presence of isolated bone metastases. Survival was significantly lower among patients with extrahepatic disease, with the exception of skeletal metastases. We conclude that CT-guided RF ablation of liver metastases from breast cancer can be performed with a high degree of technical success and technique effectiveness, providing promising survival rates in patients with no visceral extrahepatic disease. Solitary bone metastases did not negatively affect survival probability after RF ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided Laser Ablation of Osteoid Osteoma in an Open High-Field System (1.0 T)

Computed tomography is the standard imaging modality to minimize the extent of surgical or ablative treatment in osteoid osteomas. In the last 15 years, since a description of thermal ablation of osteoid osteomas was first published, this technique has become a treatment of choice for this tumor. We report the case of a 20-year-old man with an osteoid osteoma treated with laser ablation in an open high-field magnetic resonance imaging scanner (1.0 T). The tumor, located in the right fibula, was safely and effectively ablated under online monitoring. We describe the steps of this interventional procedure and discuss related innovative guidance and monitoring features and potential benefits compared with computed tomographic guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovenous Laser Ablation of Incompetent Perforator Veins: A New Technique in Treatment of Chronic Venous Disease

The aim of this study was to assess the feasibility of endovenous laser ablation of incompetent perforator veins in a patient with incompetency of the small saphenous vein and multiple perforator veins. Two different methods were used to ablate seven perforator veins with a laser giving 50-60 J/cm energy. Total occlusion was observed in six perforators, and partial ablation in one perforator, at 1-month follow-up. To our knowledge, endovenous laser ablation of incompetent perforator veins is easy and a good therapeutic method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of Fibroid Ablation Rates Using Radio Frequency or High-Intensity Focused Ultrasound

This study compared the technical success of fibroid devascularization using high-intensity focused ultrasound (HIFU) and radio frequency (RF) to provide an experimental basis for the clinical selection of a suitable, minimally invasive method for treating uterine fibroids. Patients were randomly divided into two groups and treated with HIFU or RF accordingly. The two groups of patients were divided again into subgroups A, B, and C based on fibroid diameter and subgroups A', B', and C' based on fibroid blood supply grades. The fibroid diameters in subgroups A, B, and C were 2.0 cm {<=} D < 4.0 cm, 4.0 cm {<=} D<6.0 cm and 6.0 cm {<=} D<8.0 cm, respectively, and fibroid blood supplies were classified into three grades corresponding to subgroups A', B', and C', respectively. The complete ablation rates of the two treatments were compared by contrast-enhanced ultrasound. Both treatments were effective, but the general complete ablation rate of RF was higher than that of HIFU (p < 0.05). The comparison between the two treatments in subgroup A and subgroup A' showed that the complete ablation rate of HIFU was as good as that of RF (p > 0.05). In other subgroups, the complete ablation rates of RF were better than those of HIFU (p < 0.05). No severe complications were observed after these two treatments. RF can be applied for the majority of fibroids. As a noninvasive therapy, HIFU could be the preferred method for the treatment of small, hypovascular fibroids.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irreversible Electroporation for Focal Ablation at the Porta Hepatis

Patients with chemotherapy-refractory liver metastases who are not candidates for surgery may be treated with focal ablation techniques with established survival benefits. Irreversible electroporation is the newest of these and has the putative advantages of a nonthermal action, preventing damage to adjacent biliary structures and bowel. This report describes the use of irreversible electroporation in a 61-year-old man with a solitary chemoresistant liver metastasis unsuitable for radiofrequency ablation as a result of its proximity to the porta hepatis. At 3 months, tumor size was decreased on computed tomography from 28 Multiplication-Sign 19 to 20 Multiplication-Sign 17 mm, representing stable disease according to the response evaluation criteria in solid tumors. This corresponded to a decrease in tumor volume size from 5.25 to 3.16 cm{sup 3}. There were no early or late complications. Chemoresistant liver metastases in the proximity of the porta hepatis that are considered to be too high a risk for conventional surgery or thermal ablation may be considered for treatment by the novel ablation technique of irreversible electroporation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

US-Guided Femoral and Sciatic Nerve Blocks for Analgesia During Endovenous Laser Ablation

Endovenous laser ablation may be associated with significant pain when performed under standard local tumescent anesthesia. The purpose of this study was to investigate the efficacy of femoral and sciatic nerve blocks for analgesia during endovenous ablation in patients with lower extremity venous insufficiency. During a 28-month period, ultrasound-guided femoral or sciatic nerve blocks were performed to provide analgesia during endovenous laser ablation in 506 legs and 307 patients. The femoral block (n = 402) was performed at the level of the inguinal ligament, and the sciatic block at the posterior midthigh (n = 124), by injecting a diluted lidocaine solution under ultrasound guidance. After the blocks, endovenous laser ablations and other treatments (phlebectomy or foam sclerotherapy) were performed in the standard fashion. After the procedures, a visual analogue pain scale (1-10) was used for pain assessment. After the blocks, pain scores were 0 or 1 (no pain) in 240 legs, 2 or 3 (uncomfortable) in 225 legs, and 4 or 5 (annoying) in 41 legs. Patients never experienced any pain higher than score 5. The statistical analysis revealed no significant difference between the pain scores of the right leg versus the left leg (p = 0.321) and between the pain scores after the femoral versus sciatic block (p = 0.7). Ultrasound-guided femoral and sciatic nerve blocks may provide considerable reduction of pain during endovenous laser and other treatments, such as ambulatory phlebectomy and foam sclerotherapy. They may make these procedures more comfortable for the patient and easier for the operator.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Margin Size is an Independent Predictor of Local Tumor Progression After Ablation of Colon Cancer Liver Metastases

This study was designed to evaluate the relationship between the minimal margin size and local tumor progression (LTP) following CT-guided radiofrequency ablation (RFA) of colorectal cancer liver metastases (CLM). An institutional review board-approved, HIPPA-compliant review identified 73 patients with 94 previously untreated CLM that underwent RFA between March 2003 and May 2010, resulting in an ablation zone completely covering the tumor 4-8 weeks after RFA dynamic CT. Comparing the pre- with the post-RFA CT, the minimal margin size was categorized to 0, 1-5, 6-10, and 11-15 mm. Follow-up included CT every 2-4 months. Kaplan-Meier methodology and Cox regression analysis were used to evaluate the effect of the minimal margin size, tumor location, size, and proximity to a vessel on LTP. Forty-five of 94 (47.9 %) CLM progressed locally. Median LTP-free survival (LPFS) was 16 months. Two-year LPFS rates for ablated CLM with minimal margin of 0, 1-5 mm, 6-10 mm, 11-15 mm were 26, 46, 74, and 80 % (p < 0.011). Minimal margin (p = 0.002) and tumor size (p = 0.028) were independent risk factors for LTP. The risk for LTP decreased by 46 % for each 5-mm increase in minimal margin size, whereas each additional 5-mm increase in tumor size increased the risk of LTP by 22 %. An ablation zone with a minimal margin uniformly larger than 5 mm 4-8 weeks postablation CT is associated with the best local tumor control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Direct Heating During Radiofrequency and Microwave Ablation in Ex Vivo Liver

This study was designed to determine the magnitude and spatial distribution of temperature elevations when using 480 kHz RF and 2.45 GHz microwave energy in ex vivo liver models. A total of 60 heating cycles (20 s at 90 W) were performed in normal, RF-ablated, and microwave-ablated liver tissues (n = 10 RF and n = 10 microwave in each tissue type). Heating cycles were performed using a 480-kHz generator and 3-cm cooled-tip electrode (RF) or a 2.45-GHz generator and 14-gauge monopole (microwave) and were designed to isolate direct heating from each energy type. Tissue temperatures were measured by using fiberoptic thermosensors 5, 10, and 15 mm radially from the ablation applicator at the depth of maximal heating. Power delivered, sensor location, heating rates, and maximal temperatures were compared using mixed effects regression models. No significant differences were noted in mean power delivered or thermosensor locations between RF and microwave heating groups (P > 0.05). Microwaves produced significantly more rapid heating than RF at 5, 10, and 15 mm in normal tissue (3.0 vs. 0.73, 0.85 vs. 0.21, and 0.17 vs. 0.09 Degree-Sign C/s; P < 0.05); and at 5 and 10 mm in ablated tissues (2.3 {+-} 1.4 vs. 0.7 {+-} 0.3, 0.5 {+-} 0.3 vs. 0.2 {+-} 0 Degree-Sign C/s, P < 0.05). The radial depth of heating was {approx}5 mm greater for microwaves than RF. Direct heating obtained with 2.45-GHz microwave energy using a single needle-like applicator is faster and covers a larger volume of tissue than 480-kHz RF energy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Intraductal Radiofrequency Ablation is a Safe Treatment for Malignant Biliary Obstruction: Feasibility and Early Results

Purpose. Previous clinical studies have shown the safety and efficacy of this novel radiofrequency ablation catheter when used for endoscopic palliative procedures. We report a retrospective study with the results of first in man percutaneous intraductal radiofrequency ablation in patients with malignant biliary obstruction. Methods. Thirty-nine patients with inoperable malignant biliary obstruction were included. These patients underwent intraductal biliary radiofrequency ablation of their malignant biliary strictures following external biliary decompression with an internal-external biliary drainage. Following ablation, they had a metal stent inserted. Results. Following this intervention, there were no 30-day mortality, hemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the 39 patients, 28 are alive and 10 patients are dead with a median survival of 89.5 (range 14-260) days and median stent patency of 84.5 (range 14-260) days. One patient was lost to follow-up. All but one patient had their stent patent at the time of last follow-up or death. One patient with stent blockage at 42 days postprocedure underwent percutaneous transhepatic drain insertion and restenting. Among the patients who are alive (n = 28) the median stent patency was 92 (range 14-260) days, whereas the patients who died (n = 10) had a median stent patency of 62.5 (range 38-210) days. Conclusions. In this group of patients, it appears that this new approach is feasible and safe. Efficacy remains to be proven in future, randomized, prospective studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal Hydrothermal Ablation: Preliminary Investigation of a New Concept

PurposeTo determine whether focal tissue ablation is possible with interstitial instillation of steam.MethodsFresh swine livers were used. Through a 20 gauge needle, steam was instilled every 5 s, 3 (n = 5), 6 (n = 5), 9 (n = 5), or 12 (n = 5 + 5) times in a liver lobe. The ablated zones were sectioned parallel (n = 20) or perpendicular (n = 5) to the needle track. The longitudinal long and short axis diameters, or transverse long and short axis diameters of areas with discoloration on macroscopic examination, were measured. The experiment was repeated in vivo on a pig. Steam instillation was performed once every 5 s for 5 min in the liver (n = 3) and in muscle (n = 4), and temperature changes at three neighboring sites were monitored. Long and short axis diameters of the discolored areas were measured.ResultsA well-defined area of discoloration was invariably present at the site of steam instillation. The median longitudinal long axis diameter were 2.0, 2.5, 2.5, and 3.5 cm for 3, 6, 9, and 12 steam instillations in vitro, while median short axis diameters were 1.0, 1.5, 1.5, and 1.5 cm, respectively. Six attempts at ablation in vivo could be successfully completed. The long axis diameters of the ablated zones in the liver were 7.0 and 8.0 cm, while in muscle it ranged from 5.5 to 7.0 cm.ConclusionInstillation of steam in the liver in vitro and in vivo, and in muscle in vivo rapidly leads to circumscribed zones of coagulation necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗