Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Using solenoid as multipurpose tool for measuring beam parameters

Solenoids are frequently used for focusing low-energy beams. In this paper, we show how they can serve as multipurpose diagnostics tools to measure various beam parameters, including energy, emittance, the second moments of the transverse distribution, and the beam position and angle with respect to the solenoid’s axis. The energy measurement is based on rotation of the plane of the transverse motion, as opposed to generating dispersion with a dipole. Measurement of the beam trajectory with respect to the solenoid axis is done by analyzing the beam orbit downstream of the solenoid while varying its current. The second moments are calculated by analyzing the beam image on a profile monitor while accounting for the beam rotation caused by the solenoid. We describe in detail the corresponding procedures and the experimental results of these measurements.

43 PARTICLE ACCELERATORS↗

Towards High-Repetition-Rate Fast Neutron Sources Using Novel Enabling Technologies

High-flux, high-repetition-rate neutron sources are of interest in studying neutron-induced damage processes in materials relevant to fusion, ultimately guiding designs for future fusion reactors. Existing and upcoming petawatt laser systems show great potential to fulfill this need. Here, we present a platform for producing laser-driven neutron beams based on a high-repetition-rate cryogenic liquid jet target and an adaptable stacked lithium and beryllium converter. Selected ion and neutron diagnostics enable monitoring of the key parameters of both beams. A first single-shot proof-of-principle experiment successfully implemented the presented platform at the Texas Petawatt Laser facility, achieving efficient generation of a forward-directed neutron beam. This work lays the foundation for future high-repetition-rate experiments towards pulsed, high-flux, fast neutron sources for radiation-induced effect studies relevant for fusion science and applications that require neutron beams with short pulse duration.

47 OTHER INSTRUMENTATION↗

Physical Sciences Vistas: Perspectives on Simultaneous Excellence (Issue 1, 2023)

The issue begins with an article highlighting Physics Division’s involvement in diagnostic development that led to the measurement of ignition at the National Ignition Facility at Lawrence Livermore National Laboratory. Subsequent articles transition to some of the materials development occurring in Sigma, Materials Science and Technology, and Materials Physics and Applications divisions. This is inclusive of the development of next generation moderator materials as an enabling technology of small modular reactors. These materials will most likely be qualified at a facility at Idaho National Laboratory. The issue also highlights development of novel, additively manufactured foams for next generation weapons. This work is being done in close collaboration with the Kansas City National Security Campus to enable transition of materials development to production in a more agile way. Finally, an article describes Accelerator Operations and Technology Division’s hard work to replace the legacy remote instrumentation and control equipment at the Los Alamos Neutron Science Center (LANSCE) with a modern control system. The story discusses how that engineering success will lead to improved sustainability of the beam during operation and thus a better experience for all of our collaborators and partners in the LANSCE user program.

36 MATERIALS SCIENCE↗

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS↗

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosis of the imploding shell asymmetry in polar-direct-drive deuterium–tritium cryogenic target implosions on OMEGA

We discuss the analyses of gated, x-ray imaging data from polar-direct-drive experiments with cryogenically layered deuterium–tritium targets on the OMEGA laser. The in-flight shell asymmetries were diagnosed at various times during the implosion, which was caused by the beam pointing geometry and preimposed variations in the energy partition between the different groups of laser beams. The shape of the ablation surface during the acceleration phase of the implosion was measured along two different lines of sight, and a Legendre mode (ℓ-mode) decomposition was applied for modes of up to ten to investigate shell asymmetries. A clear causal relationship between the imposed beam imbalance and the shape of the in-flight shell asymmetries was observed. The imploded shell with a balanced energy ratio shows smaller values of the amplitudes of ℓ-mode 2 compared to that from implosions with an imbalanced ring energy ratio. The amplitudes of ℓ-modes 4 and 6 are the same within the measurement uncertainty with respect to the change in beam energy ratio.

47 OTHER INSTRUMENTATION↗

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

NSLS-II longitudinal impedance budget

From the beginning of the NSLS-II project, the vacuum chamber of the NSLS-II storage ring has been optimized to reduce its impedance. The optimization, performed in close collaboration with the Diagnostic, Vacuum, RF, and Mechanical Engineering groups, has been achieved via calculating the impedance of the vacuum chamber components with the use of both analytical and numerical tools, with the numerical computations carried out with the GdfidL code. Fore reliable NSLS-II operation with the total beam current of 500 mA, each component of the vacuum chamber has been individually optimized to minimize the beam-induced heating and to prevent single-bunch and coupled-bunch instabilities. In this study, the impedance calculation and optimization know-how are summarized for all the chamber components, and the total longitudinal impedance budget is analyzed. As a result of this extensive research and engineering effort, the design beam current of 500 mA has been recently accumulated in NSLS-II without any major problem caused by collective effects.

43 PARTICLE ACCELERATORS↗

Beam-Based Diagnostics of Electric Guide Fields and Lattice Parameters for Run-1 of the Muon g-2 Storage Ring at Fermilab

A portion of the Muon g-2 Storage Ring electric system, which provides vertical beam focusing, exhibited an unexpected time dependence that produced a characteristic evolution of the stored beam during Run-1 of the Muon g-2 Experiment at Fermilab (E989). A method to reconstruct the Run-1 electric guide fields has been developed, which is based on a numerical model of the muon storage ring and optimization algorithms supported by COSY INFINITY. This method takes beam profile measurements from the Muon g-2 straw tracking detectors as input, and it produces a full reconstruction of the time-dependent fields. The fields can then be used for the reproduction of detailed beam tracking simulations and the calculation of ring lattice parameters for acceptance studies and systematic error evaluations.

43 PARTICLE ACCELERATORS↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Development Of Non-Invasive Beam Diagnostics By Quantum Optics-Based Detection

We report our effort and latest progress developing diagnostics using quantum optics-based detection method for determining the spatial properties and current of electron beams. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin’s quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size and total current. We tested this method for an e-beam with currents ranging from 30 to 110 µA. Our study shows this approach is insensitive to electron kinetic energy, and is initially verified experimentally between 10 to 20 keV. A different approach was also performed with highly excited rubidium atoms in Rydberg states through a coherent two photon process. We use this detection scheme to measure the electric field generated by a

Zhang, S. [Thomas Jefferson National Accelerator F↗

Thermal emittance and lifetime of alkali-antimonide photocathodes grown on GaAs and molybdenum substrates evaluated in a –300 kV dc photogun

In this work, Cs x K y Sb photocathodes grown on GaAs and molybdenum substrates were evaluated using a –300 kV dc high voltage photogun and diagnostic beam line. Photocathodes grown on GaAs substrates, with varying antimony layer thickness (estimated range from <20 nm to >1 um), yielded similar thermal emittance per rms laser spot size values (~0.4 mmmrad=mm) but very different operating lifetime. Similar thermal emittance was obtained for a photocathode grown on a molybdenum substrate but with markedly improved lifetime. For this photocathode, no decay in quantum efficiency was measured at 4.5 mA average current and with peak current 0.55 A at the photocathode.

43 PARTICLE ACCELERATORS↗

A general Bayesian algorithm for the autonomous alignment of beamlines

Autonomous methods to align beamlines can decrease the amount of time spent on diagnostics, and also uncover better global optima leading to better beam quality. The alignment of these beamlines is a high-dimensional expensive-to-sample optimization problem involving the simultaneous treatment of many optical elements with correlated and nonlinear dynamics. Bayesian optimization is a strategy of efficient global optimization that has proved successful in similar regimes in a wide variety of beamline alignment applications, though it has typically been implemented for particular beamlines and optimization tasks. In this paper, we present a basic formulation of Bayesian inference and Gaussian process models as they relate to multi-objective Bayesian optimization, as well as the practical challenges presented by beamline alignment. We show that the same general implementation of Bayesian optimization with special consideration for beamline alignment can quickly learn the dynamics of particular beamlines in an online fashion through hyperparameter fitting with no prior information. We present the implementation of a concise software framework for beamline alignment and test it on four different optimization problems for experiments on X-ray beamlines at the National Synchrotron Light Source II and the Advanced Light Source, and an electron beam at the Accelerator Test Facility, along with benchmarking on a simulated digital twin. We discuss new applications of the framework, and the potential for a unified approach to beamline alignment at synchrotron facilities.

47 OTHER INSTRUMENTATION↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Summary for Z-Petawatt Laser Activities (CY2019)

The high-energy upgrade of the Z-Petawatt (ZPW) laser system involved a shot hiatus starting in October 2018 to allow the installation of full-aperture optics in the chain, including in the main amplifier section as well as in the branches associated with the ZPW compressor and co-injection (the narrowband nanosecond operating mode that is co-bored with Z-Beamlet). Laser shots resumed May 1 st , with most shots since being in the ns mode to reduce complexity (while conditioning optics and calibrating diagnostics) as well as to support experimental requests. To facilitate experimental needs while a final full-sized co-injection optic was prepared, a sub-apertured beam has been used for experimental applications and a full-apertured beam has been used to validate the system. In the latter case, the beam is directed to a large calorimeter placed before branching occurs to the ZPW compressor or co-injection. As of September 2019, full-aperture co-injection shots had ramped up to 960J in 2.3ns, with many cross-calibrations being used to map out a relative humidity dependency in the leaky diagnostic mirror. Several such cross-calibration shots have been done using a chirped pulse seed as well, verifying that the diagnostic calibrations are valid in both broadband and narrow-band modes. Summarizing, since May 1 st of 2019 when shots resumed, 93 full system shots were performed with the ZPW laser. This included 2 co-injection shots with ZBL into Z (in support of MagLIF), 26 Pecos gas cell shots (in support of MagLIF), 11 Conchas gas cell shots (in support of UXI applications development), 6 Jemez shots (in support of backlighter development), and 48 calorimeter shots (in support of validating the system performance). Of these 93 shots, 45 shots were in conjunction with ZBL.

43 PARTICLE ACCELERATORS↗

A Bayesian framework to investigate radiation reaction in strong fields

Recent experiments aiming to measure phenomena predicted by strong-field quantum electrodynamics (SFQED) have done so by colliding relativistic electron beams and high-power lasers. In such experiments, measurements of collision parameters are not always feasible. However, precise knowledge of these parameters is required to accurately test SFQED. Here, we present a novel Bayesian inference procedure that infers collision parameters that could not be measured on-shot. This procedure is applicable to all-optical non-linear Compton scattering experiments investigating radiation reaction. The framework allows multiple diagnostics to be combined self-consistently and facilitates the inclusion of known information pertaining to the collision parameters. Using this Bayesian analysis, the relative validity of the classical, quantum-continuous and quantum-stochastic models of radiation reaction was compared for several test cases, which demonstrates the accuracy and model selection capability of the framework and highlight its robustness if the experimental values of fixed parameters differ from their values in the models.

47 OTHER INSTRUMENTATION↗