Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Passive Capture Joint with Three Degrees of Freedom

A passive capture joint with three degrees of freedom is presented wherein two structural elements are joined together solely by moving the two elements into position, and which when joined together have rotation in all three axes. The inventive apparatus is comprised of two halves: (1) a joint ball mounted on a stem as in a common trailer hitch, and; (2) a socket. The socket consists of a base having an exterior wall and forming an interior chamber, the chamber having a top end and a bottom end, and an interior wall. The chamber is open at the top end, and forms a spherical cup at the bottom end. The socket base's interior chamber is sized to accept the joint ball. The base also forms at least one bore at an acute angle away from the interior chamber's open end. The bores have a first opening in the interior wall of the chamber, and a second opening in the exterior wall of the base. Retaining balls sized to fit within the bores, but to only partially pass through the first opening, are moveably housed within the bores. The retaining balls are moveably held in the first opening by a compression spring housed in the bore. As the joint ball is inserted in the chamber it forces the retaining balls back into the bore until the equator of the joint ball passes. Because the bore is at an acute angle to the chamber the joint ball cannot exit the chamber without the joint being unlocked. The joint is unlocked by rotating a locking ring which encircles the base and covers the second opening. The locking ring has a radial slot for each retaining ball, disposed angularly from the base, and sized to allow passage of the retaining ball in the radial direction when the locking ring is rotated to align the radial slot with the second opening.

Richard A Cloyd↗

Estimation Filter for Alignment of the Spitzer Space Telescope

A document presents a summary of an onboard estimation algorithm now being used to calibrate the alignment of the Spitzer Space Telescope (formerly known as the Space Infrared Telescope Facility). The algorithm, denoted the S2P calibration filter, recursively generates estimates of the alignment angles between a telescope reference frame and a star-tracker reference frame. At several discrete times during the day, the filter accepts, as input, attitude estimates from the star tracker and observations taken by the Pointing Control Reference Sensor (a sensor in the field of view of the telescope). The output of the filter is a calibrated quaternion that represents the best current mean-square estimate of the alignment angles between the telescope and the star tracker. The S2P calibration filter incorporates a Kalman filter that tracks six states - two for each of three orthogonal coordinate axes. Although, in principle, one state per axis is sufficient, the use of two states per axis makes it possible to model both short- and long-term behaviors. Specifically, the filter properly models transient learning, characteristic times and bounds of thermomechanical drift, and long-term steady-state statistics, whether calibration measurements are taken frequently or infrequently. These properties ensure that the S2P filter performance is optimal over a broad range of flight conditions, and can be confidently run autonomously over several years of in-flight operation without human intervention.

Bayard, David↗

A fixed-base simulation study of two STOL aircraft flying curved, descending instrument approach paths

A real-time, fixed-base simulation study has been conducted to determine the curved, descending approach paths (within passenger-comfort limits) that would be acceptable to pilots, the flight-director-system logic requirements for curved-flight-path guidance, and the paths which can be flown within proposed microwave landing system (MLS) coverage angles. Two STOL aircraft configurations were used in the study. Generally, no differences in the results between the two STOL configurations were found. The investigation showed that paths with a 1828.8 meter turn radius and a 1828.8 meter final-approach distance were acceptable without winds and with winds up to at least 15 knots for airspeeds from 75 to 100 knots. The altitude at roll-out from the final turn determined which final-approach distances were acceptable. Pilots preferred to have an initial straight leg of about 1 n. mi. after MLS guidance acquisition before turn intercept. The size of the azimuth coverage angle necessary to meet passenger and pilot criteria depends on the size of the turn angle: plus or minus 60 deg was adequate to cover all paths execpt ones with a 180 deg turn.

Benner, M. S.↗

Achromatic nested Kirkpatrick-Baez mirror optics for hard x-ray nanofocusing.

The first test of nanoscale-focusing Kirkpatrick-Baez (KB) mirrors in the nested (or Montel) configuration used at a hard X-ray synchrotron beamline is reported. The two mirrors are both 40 mm long and coated with Pt to produce a focal length of 60 mm at 3 mrad incident angle, and collect up to a 120 {micro}m by 120 {micro}m incident X-ray beam with maximum angular acceptance of 2 mrad and a broad bandwidth of energies up to 30 keV. In an initial test a focal spot of about 150 nm in both horizontal and vertical directions was achieved with either polychromatic or monochromatic beam. The nested mirror geometry, with two mirrors mounted side-by-side and perpendicular to each other, is significantly more compact and provides higher demagnification than the traditional sequential KB mirror arrangement. Ultimately, nested mirrors can focus larger divergence to improve the diffraction limit of achromatic optics. A major challenge with the fabrication of the required mirrors is the need for near-perfect mirror surfaces near the edge of at least one of the mirrors. Special polishing procedures and surface profile coating were used to preserve the mirror surface quality at the reflecting edge. Further developments aimed at achieving diffraction-limited focusing below 50 nm are underway.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation for a Measurement of Charge Asymmetry in the Bethe-Heitler Process

We have prepared a measurement of the energy asymmetry in wide- and medium-angle electron/positron pair production off protons and heavy targets. This asymmetry is caused by the interference between the first- and second-order Born diagrams and the Compton scattering diagram. It directly probes aspects of QED, as well as providing a direct measurement of the real part of the Compton amplitude. It will be conducted at the HI??S facility at Duke University, using a 60 MeV photon beam. This dissertation serves as documentation of the preparation stage of the Bethe-Heitler experiment. The major was the recommissioning of the vertical drift chambers previously used in the Q-weak experiment at the Jefferson Lab. Cosmic test runs were conducted, drift time data were collected and efficiency plateaus were measured. We made modifications to the JLAB Hall A analyzer to suit the geometry and drift characteristics of these wire chambers. The analyzer was used for the reconstruction of the trajectories of cosmic ray test runs with the results confirmed by direct measurement of trigger geometry. Spatial and angular resolution is estimated to ~300?? and 0.17° respectively. Geant 4 simulations with generated Bethe-Heitler pairs satisfying theoretical differential cross sections. It was used to check detector acceptance, optimize apparatus layout, and estimate measurable energy asymmetry. The measurable asymmetries from electron/positron pairs with polar angles around between approximately 5° and 8°, azimuthal angles differing by 180°, and energy differing by approximately 9 MeV to 15 MeV are predicted to be above 10%. The kinematics of primary vertices are reconstructed using the data from wire chambers in the simulation. The energy resolution is determined to be better than 1MeV.

Chen, Haoyu↗

Domain crossover in the reductase subunit of NADPH-dependent assimilatory sulfite reductase

NADPH-dependent assimilatory sulfite reductase (SiR) from Escherichia coli performs a six-electron reduction of sulfite to the bioavailable sulfide. SiR is composed of a flavoprotein (SiRFP) reductase subunit and a hemoprotein (SiRHP) oxidase subunit. There is no known high-resolution structure of SiR or SiRFP, thus we do not yet fully understand how the subunits interact to perform their chemistry. Here, we used small-angle neutron scattering to understand the impact of conformationally restricting the highly mobile SiRFP octamer into an electron accepting (closed) or electron donating (open) conformation, showing that SiR remains active, flexible, and asymmetric even with these conformational restrictions. From these scattering data, we then model the first solution structure of SiRFP. Further, computational modeling of the N-terminal 52 amino acids that are responsible for SiRFP oligomerization suggests an eight-helical bundle tethers together the SiRFP subunits to form the SiR core. Finally, mass spectrometry analysis of the closed SiRFP variant show that SiRFP is capable of inter-molecular domain crossover, in which the electron donating domain from one polypeptide is able to interact directly with the electron accepting domain of another polypeptide. This structural characterization suggests that SiR performs its high-volume electron transfer through both inter- and intramolecular pathways between SiRFP domains and, thus, cis or trans transfer from reductase to oxidase subunits. Such highly redundant potential for electron transfer makes this system a potential target for designing synthetic enzymes.

59 BASIC BIOLOGICAL SCIENCES↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

STATUS OF THE JLEIC ION COLLIDER RING DESIGN

We present an update on the lattice design and beam dynamics study of the ion collider ring of JLEIC (Jefferson Lab Electron Ion Collider). The collider ring consists of two 261.7 degree arcs connected by two straight sections crossing each other. One of the straights houses an interaction region (IR) and is shaped to make a 50 mrad crossing angle with the electron beam at the interaction point (IP) to meet physics requirements. The forward acceptance requirements downstream of the IP in the ion direction lead to an asymmetric IR lattice design. The detector solenoid effects and the multipole fields of the IR magnets further complicate this picture. In this paper, compensation of the detector solenoid effects is considered together with orbit correction and multipole effects. We also study local compensation of the magnet multipoles using dedicated multipole correctors. And an optimization of the betatron tunes is also presented.

Wei, Guohui↗

On optical imaging through aircraft turbulent boundary layers

Optical resolution quality as affected by aircraft turbulent boundary layers is analyzed. Wind-tunnel data was analyzed to obtained the variation of boundary layer turbulence scale length and mass density rms fluctuations with Mach number. The data gave good agreement with a mass density fluctuation turbulence spectrum that is either isotropic of orthogonally anisotropic. The data did not match an isotropic turbulence velocity spectrum which causes an anisotropic non-orthogonal mass density fluctuation spectrum. The results indicate that the average mass density rms fluctuation is about 10% of the maximum mass density across the boundary layer and that the transverse turbulence scale size is about 10% of the boundary layer thickness. The results indicate that the effect of the turbulent boundary layer is large angle scattering which decreases contrast but not resolution. Using extinction as a criteria the range of acceptable aircraft operating conditions are given.

Sutton, G. W.↗

Flutter Clearance of the F-18 High-angle-of-attack Research Vehicle with Experimental Wingtip Instrumentation Pods

An F-18 aircraft was modified with wingtip instrumentation pods for use in NASA's high-angle-of-attack research program. Ground vibration and flight flutter testing were performed to clear an acceptable flight envelope for the aircraft. Flight test utilized atmospheric turbulence for structural excitation; the aircraft displayed no adverse aeroelastic trends within the envelope tested. The data presented in this report include mode shapes from the ground vibration and estimates of frequency and damping as a function of Mach number.

Freudinger, Lawrence C.↗

Interstellar Pickup Hydrogen Observations from the Pioneer 10 and 11 Plasma Analyzers

The Pioneer 10 and 11 Ames plasma analyzers included off-angle integrating counters used for the first exploration of magnetospheric plasmas at Jupiter and Saturn. When summed over multi-day intervals during interplanetary cruise, at times of relatively constant solar wind speed during 1972 to 1977, the resulting count rates show a dependence on acceptance energies of the plasma analyzer deflection plates. The count rates could be produced by energetic charged particles, solar wind protons moving at a large angle to the bulk flow, and interstellar pickup ions. We interpret the more energetic of two peaks that are sometimes observed as the signature of interstellar pickup hydrogen. This peak is located at just below twice the solar wind speed (V(sub SW)), when near 3 AU heliocentric distance, decreasing to just above V(sub SW) as the heliocentric distance increases. Also, in the 8 to 12 AU range of heliocentric distances, we identify the pickup hydrogen signature as a shelf that ends at an edge located below 2V(sub SW). During these observations, the spacecraft longitude relative to the upstream interstellar flow changes roughly from 25 deg, to 155 deg at the larger heliocentric distance. The peak at the smaller heliocentric distances is most consistent with a velocity distribution that is a shell in phase space, with limited thickening as the pickup ions are assimilated into the solar wind flow.

Mihalov, J. D.↗

Continuous, Full-Circle Arctangent Circuit

A circuit generates an analog voltage proportional to an angle, in response to two sinusoidal input voltages having magnitudes proportional to the sine and cosine of the angle, respectively. That is to say, given input voltages proportional to sin(Omega(t))sin(Theta) and sin(Omega(t))cos(Theta) [where Theta denotes the angle, mega denotes 2(pi) x a carrier frequency, and t denotes time], the circuit generates a steady voltage proportional to Theta. The output voltage varies continuously from its minimum to its maximum value as Theta varies from -180deg to 180deg. While the circuit could accept input modulated sine and cosine signals from any source, it must be noted that such signals are typical of the outputs of shaft-angle resolvers in electromagnetic actuators used to measure and control shaft angles for diverse purposes like aiming scientific instruments and adjusting valve openings. In effect, the circuit is an analog computer that calculates the arctangent of the ratio between the sine and cosine signals. The full-circle angular range of this arctangent circuit stands in contrast to the range of prior analog arctangent circuits, which is from slightly greater than -90deg to slightly less than +90deg. Moreover, for applications in which continuous variation of output is preferred to discrete increments of output, this circuit offers a clear advantage over resolver- to-digital integrated circuits.

Alhorn, Dean C.↗

Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans

Purpose: The authors investigated the performance of several patient-specific intensity-modulated radiation therapy (IMRT) quality assurance (QA) dosimeters in terms of their ability to correctly identify dosimetrically acceptable and unacceptable IMRT patient plans, as determined by an in-house-designed multiple ion chamber phantom used as the gold standard. A further goal was to examine optimal threshold criteria that were consistent and based on the same criteria among the various dosimeters. Methods: The authors used receiver operating characteristic (ROC) curves to determine the sensitivity and specificity of (1) a 2D diode array undergoing anterior irradiation with field-by-field evaluation, (2) a 2D diode array undergoing anterior irradiation with composite evaluation, (3) a 2D diode array using planned irradiation angles with composite evaluation, (4) a helical diode array, (5) radiographic film, and (6) an ion chamber. This was done with a variety of evaluation criteria for a set of 15 dosimetrically unacceptable and 9 acceptable clinical IMRT patient plans, where acceptability was defined on the basis of multiple ion chamber measurements using independent ion chambers and a phantom. The area under the curve (AUC) on the ROC curves was used to compare dosimeter performance across all thresholds. Optimal threshold values were obtained from the ROC curves while incorporating considerations for cost and prevalence of unacceptable plans. Results: Using common clinical acceptance thresholds, most devices performed very poorly in terms of identifying unacceptable plans. Grouping the detector performance based on AUC showed two significantly different groups. The ion chamber, radiographic film, helical diode array, and anterior-delivered composite 2D diode array were in the better-performing group, whereas the anterior-delivered field-by-field and planned gantry angle delivery using the 2D diode array performed less well. Additionally, based on the AUCs, there was no significant difference in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. Conclusions: IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.

60 APPLIED LIFE SCIENCES↗

Integrated three-dimensional photonic nanostructures for achieving near-unity solar absorption and superhydrophobicity

In this paper, we proposed and realized 3D photonic nanostructures consisting of ultra-thin graded index antireflective coatings (ARCs) and woodpile photonic crystals. The use of the integrated ARC and photonic crystal structure can achieve broadband, broad-angle near unity solar absorption. The amorphous silicon based photonic nanostructure experimentally shows an average absorption of ∼95% for λ = 400–620 nm over a wide angular acceptance of θ = 0°–60°. Theoretical studies show that a Gallium Arsenide (GaAs) based structure can achieve an average absorption of >95% for λ = 400–870 nm. Furthermore, the use of the slanted SiO{sub 2} nanorod ARC surface layer by glancing angle deposition exhibits Cassie-Baxter state wetting, and superhydrophobic surface is obtained with highest water contact angle θ{sub CB} ∼ 153°. These properties are fundamentally important for achieving maximum solar absorption and surface self-cleaning in thin film solar cell applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

60 APPLIED LIFE SCIENCES↗

Mass spectrometer has wide angular acceptance

Higher mass resolution is achieved by replacing conventional mass/velocity spectrometers with system of planar ac-modulated grids. System gives focusing for all angles of incidence. Ac-modulation and detection scheme minimizes sensitivity to light and other types of radiation.

Neugebauer, M. M.↗

Trigger and Aperture of the Surface Detector Array of the Pierre Auger Observatory

The surface detector array of the Pierre Auger Observatory consists of 1600 water-Cherenkov detectors, for the study of extensive air showers (EAS) generated by ultra-high-energy cosmic rays. We describe the trigger hierarchy, from the identification of candidate showers at the level of a single detector, amongst a large background (mainly random single cosmic ray muons), up to the selection of real events and the rejection of random coincidences. Such trigger makes the surface detector array fully efficient for the detection of EAS with energy above $3\times 10^{18}$ eV, for all zenith angles between 0$^\circ$ and 60$^\circ$, independently of the position of the impact point and of the mass of the primary particle. In these range of energies and angles, the exposure of the surface array can be determined purely on the basis of the geometrical acceptance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of polarisation transfer $C$$^{n}_{x'}$ in deuteron photodisintegration

A first measurement of the polarisation transfer from a circularly-polarised photon to the final state neutron ($C$$^{n}_{x'}$) in deuterium photodisintegration has been carried out. This quantity is determined over the photon energy range 370 – 700 MeV and for neutron centre-of-mass breakup angles ~ 45 – 120°. The polarisation of the final state neutrons was determined by an ancillary large-acceptance nucleon polarimeter, surrounding a cryogenic liquid deuterium target within the Crystal Ball detector at MAMI. The polarimeter characterised (n, p) charge exchange of the ejected neutrons to determine their polarisation. The new $C$$^{n}_{x'}$ data are also compared to a theoretical model based on nucleonic and nucleon resonance degrees of freedom constrained by the current world-database of deuterium photodisintegration measurements. Structures in $C$$^{n}_{x'}$ observed in the region of the d*(2380) could not be explained by conventional models of deuteron photodisintegration.

79 ASTRONOMY AND ASTROPHYSICS↗