Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Changes in soluble sugar, starch, and alcohol dehydrogenase in Arabidopsis thaliana exposed to N2 diluted atmospheres

Proper exchange of atmospheric gases is important for normal root and shoot metabolism in plants. This study was conducted to determine how restricted air supply affects foliar carbohydrates, while using the marker enzyme alcohol dehydrogenase (ADH) to report on the oxygenation status of the rootzone. Fourteen-day-old Arabidopsis thaliana (L.) Heynh. plants grown singly in 7-ml tubes containing agarified nutrient medium were placed in coupled Magenta vessels and exposed for six days to either ambient air or one of six different air/nitrogen dilutions. Redox potential of the agar medium was measured immediately after harvesting and freezing leaf tissue, and then root systems were quickly extracted from the agar and frozen for subsequent analyses. Redox potential measurements indicated that this series of gas mixtures produced a transition from hypoxia to anoxia in the root zones. Root ADH activity increased at higher rates as the redox potential neared anoxic levels. In contrast, ADH mRNA expression quickly neared its maximum as the medium became hypoxic and showed little further increase as it became anoxic. Foliar carbohydrate levels increased 1.5- to 2-fold with decreased availability of metabolic gases, with starch increasing at higher concentrations of air than soluble carbohydrate. The results serve as a model for plant performance under microgravity conditions, where absence of convective air movement prevents replenishment of metabolic gases.

NASA Discipline Plant Biology↗

Lessons Learned Using in-situ TEM Liquid Corrosion of Al Alloys

Al and Al alloys are of interest in energy applications due to their strength and low weight [1] in addition to their electrochemical properties for aluminum-air batteries for energy storage [2]. However, Al alloys also are susceptible to corrosion in a variety of environments including liquid electrolytes and in solar panels [3], which has led to a great deal of research to understand and improve corrosion resistance in these materials. Al metal forms a native, passivating oxide layer in the presence of ambient air, which slows corrosion initiation. However, pitting still occurs as this protective layer breaks down in the presence of electrolytes. Thin metal Al films were used in these experiments to observe initiation and growth of pitting, which can be used as an approximation of corrosion initiation behavior in bulk samples.

alluminum alloys↗

MODEL DEVELOPMENT AND VERIFICATION OF A 1,350°C AIR RECEIVER TEST SYSTEM

Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multicycle power plants. A novel additively manufactured (AM) silicon carbide (SiC), ceramic matrix composite (CMC) volumetric receiver was developed that consisted of a lattice structure, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous receiver was transferred to heated ambient air. The receiver acted as a convective heat exchanger, transferring heat to the fluid through convection. Engineering was facilitated to develop a high-temperature air receiver test bed at Sandia national Laboratories (SNL) capable of demonstrating a 50kWth open-loop volumetric SiC air receiver module developed by General Electric Aerospace Research (GE Aerospace). This paper presents the development of the high temperature AM SiC-CMC air receiver, the test bed, and the first testing operations of this device, which was experimentally demonstrated to achieve 1,350°C for over 3.5 hours of operation, based on input flux levels of 67–91 W/cm2 0.5-2.5 kg/s flow rates. From the test campaign results, based on the measured convective heat transfer to the airflow and bounded radiative-loss assumptions, the solar-thermal efficiency of HOTSSTAR test module was estimated to be approximately as high as 74% for representative test conditions.

14 SOLAR ENERGY↗

Infrared Signature Masking by Air Plasma Radiation

Detailed measurements and modeling of the spectral emission of an atmospheric pressure air plasma at temperatures up to -3400 K have been made. The cold gas injected in the plasma torch contained an estimated mole fraction of water vapor of approximately 4.5 x 10(exp -3) and an estimated carbon dioxide mole fraction of approximately 3.3 x 10(exp -4). Under these conditions, the minimum level of air plasma emission is found to be between 3.9 and 4.15 microns. Outside this narrow region, significant spectral emission is detected that can be attributed to the fundamental and overtone bands of NO and OH, and to the v(sub 3) and the (v(sub 1)+v(sub 3)) bands Of CO2. Special attention was paid to the effects of ambient air absorption in the optical path between the plasma and the detector. Excellent quantitative agreement is obtained between the measured and simulated spectra, which are both on absolute intensity scales, thus lending confidence in the radiation models incorporated into NEQAIR2-IR over the course of this research program.

Kruger, C. H.↗

Measurement of volatile organic chemicals at selected sites in California

Urban air concentrations of 24 selected volatile organic chemicals that may be potentially hazardous to human health and environment were measured during field experiments conducted at two California locations, at Houston, and at Denver. Chemicals measured included chlorofluorocarbons, halomethanes, haloethanes, halopropanes, chloroethylenes, and aromatic hydrocarbons. With emphasis on California sites, data from these studies are analyzed and interpreted with respect to variabilities in ambient air concentrations, diurnal changes, relation to prevailing meteorology, sources and trends. Except in a few instances, mean concentrations are typically between 0 and 5 ppb. Significant variabilities in atmospheric concentrations associated with intense sources and adverse meteorological conditions are shown to exist. In addition to short-term variability, there is evidence of systematic diurnal and seasonal trends. In some instances it is possible to detect declining trends resulting from the effectiveness of control strategies.

Singh, Hanwant B.↗

Abstract for CRADA between Capture6 CORP and NETL

The National Energy Technology Laboratory (NETL) and Capture6 CORP (Participant) will collaborate to refine Capture6’s transformative air contactor design for optimal direct air capture (DAC) under an awarded project from the Department of Energy’s Direct Air Capture Pre-Commercialization Technology Prize. Current cooling tower designs require exponentially more resources as the concentration of CO 2 in the gas phase decreases, resulting in a low conversion rate of carbonates, a large physical footprint, and high evaporation of water, which consequently limits the energy and water benefits that a DAC process can create. Capture6’s innovative tower design AURA (Absorption Unit Reactor for Ambient air) seeks to improve the mass transfer characteristics of legacy cooling towers and reduces total energy demand by: (1) introducing laminar and turbulent flow to increase mass transfer, (2) generating a solvent gradient to improve CO 2 absorption, (3) leveraging venturi and packed towers to increase the surface for the mass-transfer process, (4) adding charged/cool plates to reduce overall water loss in the system, and (5) utilizing surfactant additives to increase mass transfer. The collaboration will facilitate the deployment of technologies that reduce the total energy required and carbon footprint of solvent-based carbon dioxide removal (CDR) technologies. The anticipated results support NETL’s goal of fostering rapid development and commercialization pathways for technologies that remove CO 2 from the atmosphere.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examination of the physical, electrical, and microwave evolution of sea water into young ice

Knowledge of the relationships between ice thickness, its temperature profile, the distribution of salinity, the dielectric property profile, and roughness of the air-ice interface is important to the understanding of the backscatter response of new and young sea ice. Backscatter, physical property, and electrical property measurements made in the laboratory during the first 120 h of growth aid in describing the evolution of first-year ice, in this case open water to gray ice (14.5 cm thick). Results on the evolution response for the case when the ambient air temperature is about -15 C are given, providing insight into the effects of upper ice sheet temperatures, the accompanying dielectric constant response, and the collection of brine and free water at the air-ice interface on the backscatter response.

Onstott, Robert G.↗

Direct Air Capture and Utilization System (DACUS): FEED Study of CarbonCapture Inc. DAC and CarbonCure Utilization Technologies Using United States Steel’s Gary Works Plant Waste Heat

The effects of climate change are drastically perceived through the alarming rates of severe events such as flooding, hurricanes, wildfires, global temperature rise, sea-level rise, and ocean acidification etc., which has prompted the nations across the globe to control & reduce greenhouse gas (GHG) emissions, by massive adoption of electric vehicles, switching to renewal energy sources and promoting sustainable green products. However, recent climate studies have shown that such efforts will not be enough to keep the global temperature rising under 1.5° Celsius by the year 2050, which lead to the development of multiple Direct Air Capture (DAC) technologies. A DAC system extracts CO2 directly from the atmosphere, which is either stored underground for long term or utilized in other processes. The DACUS proposed at U.S. Steel Corporation’s Gary Works Plant in Gary, Indiana, will include an innovative DAC technology from CarbonCapture Inc. (CCI), which will be collocated and powered by waste heat from the steel plant to capture CO2 from ambient air, and CarbonCure CO2 utilization technology- which is a commercial technology that is already installed and in use by early adopters in more than 150 concrete mixing plants across North America and Asia. The University of Illinois at Urbana Champaign spearheaded this Front-End Engineering Design (FEED) study project, which was funded by US Department of Energy (DOE), aimed at designing a state-of-the art DACU system that can remove minimum of 5,000 tonne/year net CO2 from air (based on cradle-to-gate LCA) and converting the captured CO2 into low carbon intensity products. The off takers of the low Carbon product produced by the DACUS have also been identified near the steel plant in the Indiana, Illinois & Wisconsin Region. This creates a full CO2 value chain and provides a means to assess the impact of this holistic approach on job creation, regional economic impact, and environmental justice. DACUS is a promising new technology for reducing greenhouse gas in the atmosphere. Operation costs are minimized by locating CCI’s innovative DAC collector at United States Steel's Gary Works site where waste heat is utilized. Carbon emissions are minimized in CO2 transportation. The captured CO2 will be permanently sequestered in concrete used as construction material. This DOE funded FEED study demonstrates a full CO2 value chain for a DACU system, supported by an industrial facility. If this project were constructed, it would have a very positive and lasting impact on both the environment and the community.

42 ENGINEERING↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scientific Verification Test of Orbitec Deployable Vegetable Production System for Salad Crop Growth on ISS- Gas Exchange System design and function

The ability to produce and maintain salad crops during long term missions would be a great benefit to NASA; the renewable food supply would save cargo space, weight and money. The ambient conditions of previous ground controlled crop plant experiments do not reflect the microgravity and high CO2 concentrations present during orbit. It has been established that microgravity does not considerably alter plant growth. (Monje, Stutte, Chapman, 2005). To support plants in a space-craft environment efficient and effective lighting and containment units are necessary. Three lighting systems were previously evaluated for radish growth in ambient air; fluorescent lamps in an Orbitec Biomass Production System Educational (BPSE), a combination of red, blue, and green LED's in a Deployable Vegetable Production System (Veggie), and a combination of red and blue LED's in a Veggie. When mass measurements compared the entire possible growing area vs. power consumed by the respective units, the Veggies clearly exceeded the BPSE indicating that the LED units were a more resource efficient means of growing radishes under ambient conditions in comparison with fluorescent lighting. To evaluate the most productive light treatment system for a long term space mission a more closely simulated ISS environment is necessary. To induce a CO2 dense atmosphere inside the Veggie's and BPSE a gas exchange system has been developed to maintain a range of 1000-1200 ppm CO2 during a 21-day light treatment experiment. This report details the design and function of the gas exchange system. The rehabilitation, trouble shooting, maintenance and testing of the gas exchange system have been my major assignments. I have also contributed to the planting, daily measurements and harvesting of the radish crops 21-day light treatment verification test.

Eldemire, Ashleigh↗

Ground cloud air quality effects

The effects of the ground cloud associated with launching of a large rocket on air quality are discussed. The ground cloud consists of the exhaust emitted by the rocket during the first 15 to 25 seconds following ignition and liftoff, together with a large quantity of entrained air, cooling water, dust and other debris. Immediately after formation, the ground cloud rises in the air due to the buoyant effect of its high thermal energy content. Eventually, at an altitude typically between 0.7 and 3 km, the cloud stabilizes and is carried along by the prevailing wind at that altitude. For the use of heavy lift launch vehicles small quantities of nitrogen oxides, primarily nitric oxide and nitrogen dioxide, are expected to be produced from a molecular nitrogen impurity in the fuel or liquid oxygen, or from entrainment and heating of ambient air in the hot rocket exhaust. In addition, possible impurities such as sulfur in the fuel would give rise to a corresponding amount of oxidation products such as sulfur dioxide.

Brubaker, K. L.↗

Advancements in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerges as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment location sand the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study introduces a significant advancement in DAC technology with the development of a Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration. Its exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale.

Wang, Qiuming↗

Innovations in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerged as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment locations and the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of an efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study explores a novel Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration (is 90 oC really low temperature?). FAM’s exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale. The synthesis process involves a simple dip-coating technique, allowing crosslinked amines to coat glass substrates.

Wang, Qiuming↗

Understanding the performance of membrane for direct air capture of CO 2

Abstract Direct air capture (DAC) of CO 2 is becoming increasingly important for reducing greenhouse gas concentrations in the atmosphere. However, the cost and energy requirements associated with DAC make it less economically feasible than carbon capture from flue gases. While various methods like solid sorbents and gas–liquid absorption have been explored for DAC, membrane processes have only recently been investigated. The objective of this study is to examine the separation performance of a membrane unit for capturing CO 2 from ambient air. The performance of a membrane depends on several factors, including the composition of the feed gas, pressure ratio, material selectivity, and membrane area. The single‐stage separation process with the co‐current flow and constant permeability flux model is evaluated using a commercial module integrated with a process simulator to separate a binary mixture of carbon dioxide and nitrogen to assess the sensitivity of selectivity on purity and recovery of CO 2 in permeate, and power requirement. Additionally, three levels of CO 2 reduction from the feed stream to the retentate stream (25%, 50%, and 75%) are studied. A trade‐off between purity and recovery factor is observed, and achieving high purity in permeate requires high concentration in the retentate.

Panja, Palash↗

High-voltage water-scarce hydrogel electrolytes enable mechanically safe stretchable Li-ion batteries

Soft Li-ion batteries, based on conventional organic electrolytes, face performance degradation challenges due to moisture penetration and safety concerns due to possible leakage of toxic fluorine compounds and flammable solvents under mechanical damage. We design a water-scarce hydrogel electrolyte with fluorine-free lithium salt to achieve wide electrochemical stability window (up to 3.11 volts) in ambient air without hermetic packaging while balancing high stretchability (1348%), ion conductivity (41 millisiemens per centimeter), and self-healing capabilities for mechanically and chemically safe stretchable Li-ion batteries. Molecular synergy between hydrophilicity and lithiophilicity of zwitterionic polymer backbone is revealed by molecular dynamics simulations. The battery exhibits capacity retention under harsh mechanical stresses—enduring stretching, twisting, folding, and multiple through-punctures by a needle—while self-healing from repeated through cuts by a razor blade. Stable ambient operation for 1 month over 500 charge-discharge cycles (average coulomb efficiency, 95%) is achieved. A prototype self-healing electronic system with embedded soft batteries demonstrates practical application as a durable embodied energy source.

Science & Technology - Other Topics↗

Effects of Increased CO2 Level on the Well-Being, Growth and Renal Function of Rats

On the Space Shuttle the mean CO2 levels have been 0.3% which is ten times normal air, while there have been extended periods with mean levels of 0.7% and peak concentrations of 2%. On the Space Station the projected mean concentration of CO2 is 0.7% and not to exceed 1.0%. To ensure that high level of CO2 does not compromise the integrity of the science on the Space Station, the effects of chronic exposure to high levels of CO2 were investigated. Following 7 days of cage adaptation animals exposed to 2% CO2 for 30 days were compared to control (ambient air) animals and the effects on the well-being, growth and renal function analyzed. Ten male rats per group were placed in individual metabolic cages which allowed monitoring of daily food and water consumption, as well as feces and urine to be collected. Cages were placed in a plexiglass chamber with internal environment controlled by a computer in conjunction with gas sensors. The elevated CO2 was held constant at 2.0 +/- 0.03% and the O2 at 20.9 +/- 0.15%. Body weight and food and water intake were measured daily for the first ten days of exposure and then every three to four days for the remaining three weeks. Urine was measured for pH, CO2 (as an indicator for bicarbonate) and ammonia (as an indicator for ammonium). During 2% CO2 exposure, animal growth, weight, food and water consumption were within normal ranges suggesting that their well-being was not affected. Urine pH decreased from 7.12 to 6.77 over the first 6 days of exposure and increased the following 24 days returning to pre-exposure levels. Urine NH4+ increased 68% the first 6 days then dropped to and remained at 29% higher than pre-exposure level. Urine bicarbonate concentration did not change the first 6 days, but significantly increased by day 30. These results of chronic exposure to 2% C02 are consistent with renal compensation for respiratory acidosis which may impact science conducted on the Space Shuttle or the Space Station if CO2 levels reach 2%.

Lang, C.↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗