Search NASA⌕ Search

SEARCH · Search NASA

Results for “and fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

TO252: Parabolic Flight Demonstration of Fluid Dispensing Tube Performance Limits for Drop Delivery

Ring Shear Drop (RSD) ISS flight hardware failed to pin sample fluid drops between two rings, likely due to dynamic instability inherent to the dispensing tube (D-Tube) design. The first parabolic flight tested 5 D-tube tip designs with two bounding surface tension fluids, enabling an engineering design decision. D-tube Tip Cage Design was selected based on the November 2020 parabolic flight test data. Flight Operations Program (FOP) approved a reflight proposal to include 2 parabolic flight days during the April/May 2021 campaign with following objectives: • Validate ISS hardware flight design with actual flight fluids (test as you fly), demonstrating the ability to deliver 1” fluid drops in near-microgravity conditions. • Demonstrate pinning of 1” flight fluid drops: a secondary pinning ring is planned to be installed in the parabolic flight hardware to meet this objective. Fluid flow rates will also be varied as needed and as possible. • Provide data to validate computational models used to guide ISS operational deployment decisions and demonstrate the viability of the redesigned hardware to accommodate a range of future flight investigations. This presentation introduces highlights and lessons learned during this recent flight campaign for discussion in the Flight Opportunities Program Panel, “Leveraging Suborbital Flight Tests to Advance Science and Technology."

Sridhar Gorti↗

Modeling of Particle Transport and Impact in Transient, Multiphase Oxidizer-Rich Environments Using Computational Fluid Dynamics and Lagrangian Particle Tracking

Particle impacts from foreign object debris (FOD) in an oxidizer-rich environment have been shown to be a credible and significant risk for ignition and failure of components and vehicles. The risk of particle ignition is dependent on many factors, including particle impact velocity/energy and fluid composition (i.e. fluid phase, species presence, and state). Prediction of particle transport and particle impacts in relevant environments, including transient, multiphase flows, is important for assessing the risk and avoiding repeated expensive system level tests. The capability to model both the fluid dynamics and particle transport in complex three-dimensional geometries and multiphase environments has been developed at Marshall Space Flight Center (MSFC) in the propulsion fluid dynamic branch (ER42) by utilizing computational fluid dynamics (CFD) simulations and Lagrangian particle tracking. Using CFD tools, including density-based Loci/CHEM with a cavitation model and pressure-based Loci/STREAM with a volume of fluids model, MSFC/ER42 has provided particle impact predictions to multiple projects for oxidizer compatibility assessments. Simulations of transient, multiphase environments such as liquid slugs flowing through tubing and cavitating flow in valves have been completed alongside one-way coupled Lagrangian particle tracking to predict particle impacts.

M.V. Fischels↗

Effects of 10 days 6 degrees head-down tilt on the responses to fluid loading and lower body negative pressure

In an international collaborative project six normal male subjects were studied before, during and after 10 days 6 degrees HDT. Fluid intake was controlled at 40 ml/(kgbw day). Urine volume and body weight were determined daily. Fluid loading and LBNP were performed in all three phases of the study. Body weight diminished by 2.6% because of fluid loss. Blood volume diminished by 13%. The responses to fluid loading were similar in the three phases of the study. Sixty minutes after end of infusion only 5.5% of the infused saline remained in the intravascular compartment. Excess interstitial fluid was eliminated in the next 24 hs but a negative balance was recorded also in the following day. The compliance of the lower limbs expressed as the rate of limb volume change/unit LBNP change was increased at the end of the HDT phase and during the post HDT phase. The set point of intravascular volume was defended, as shown by the response to FL. HDT increased the compliance of the lower limbs.

Non-NASA Center↗

A review of the consequences of fluid and electrolyte shifts in weightlessness

This review describes the renal-endocrine mechanisms related to the early losses of fluid-electrolytes from the body during weightlessness as well as their contribution to longer term adaptation of fluid-electrolyte balance. The hypotheses presented were generated by a systematic analysis of body fluid and renal dynamics observed under conditions of actual and simulated spaceflight. These have increased our understanding of the effects of acute headward fluid shifts on renal excretion, the factors promoting excess sodium excretion and the regulation of extracellular fluid composition.

Review↗

Measurement of Local Heat Transfer Coefficients for Flow of Hydrogen and Helium in a Smooth Tube at High Surface to Fluid Bulk Temperature Ratios

Local values of heat transfer coefficients have been measured experimentally for helium and hydrogen gas flowing through an electrically heated inconel tube. The experiment was conducted pri­marily to determine the effect on the heat transfer coefficient of a large density change, radially, in the heat transfer fluid. This large density change was accomplished with relatively high surface temperatures as compared to fluid bulk temperatures or more commonly referred to as high surface to fluid bulk tempera­ture ratio. The large temperature ratio was achieved by precooling the gas with liquid nitrogen. Data were measured for local values of surface to fluid bulk temperature ratios up to 4.5, Reynolds numbers in the turbulent flow region, surface temperatures up to 2300° R, heat flux up to 1,600,000 Btu/(hr)(sq ft) and length to diameter ratio of 250. A comparison of this data with the conventional heat transfer· correlation equation (Dittus-Boelter eq.) is shown on a curve of Nusselt number divided by Prandtl number versus the Reynolds number. The gas properties were evaluated at the film temperature and the Reynolds number was modified by evaluating the velocity term at the fluid bulk temperature and the density at the film temperature.

Weiland, Walter F.↗

Rheology of synovial fluid and its role in joint lubrication

A review of studies by Barnett, Davies, MacConaill, Charnley, Ogston, Sundblad, and others indicates that there exists a tendency to explain the lubricating mechanism existing in synovial joints by either the lubricating properties of synovial fluid or the lubricating properties of the articular surfaces. The proponents of the respective hypothesis attempted to apply either the theory of hydrodynamic lubrication or the theory of boundary lubrication. Neither of these theories, however, can represent the lubrication mechanism in joints; both theories are too crude for this purpose. The nearest approach to reality appears to be represented by more recent elastohydrodynamic theories. It is the aim of this paper to show that both the synovial fluid and the articular cartilage play an important role in the joint lubrication, and that thixotropy of synovial fluid is the key parameter in the lubricating performance of the synovial fluid itself, and of the cartilage whose pores it fills. It will be suggested also that any pathological changes in either the synovial fluid or the articular cartilage, lead to a breakdown of joint lubrication.

LUBRICATION↗

Fluid technology (selected components, devices, and systems): A compilation

Developments in fluid technology and hydraulic equipment are presented. The subjects considered are: (1) the use of fluids in the operation of switches, amplifiers, and servo devices, (2) devices and data for laboratory use in the study of fluid dynamics, and (3) the use of fluids as controls and certain methods of controlling fluids.

Source record↗

Low-G fluid behavior technology summaries

This report presents a summarization and categorization of the pertinent literature associated with low-g fluid behavior technology. Initially a literature search was conducted to obtain pertinent documents for review. Reports determined to be of primary significance are summarized in detail. Each summary, where applicable, consists of; (1) report identification, (2) objective(s) of the work, (3) description of pertinent work performed, (4) major results, and (5) comments of the reviewer (GD/C). Pertinent figures are presented on a single facing page separate from the text. Specific areas covered are; interface configuration, interface stability, natural frequency and damping, liquid reorientation, bubbles and droplets, fluid inflow, fluid outflow, convection, boiling and condensation heat transfer, venting effects, and fluid properties. Reports which were reviewed and not summarized, along with reasons for not summarizing, are also listed. Cryogenic thermal control and fluid management systems technology are presented.

Stark, J. A.↗

Anthropometric changes and fluid shifts

Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

Thornton, W. E.↗

Stability of flow of a thermoviscoelastic fluid between rotating coaxial circular cylinders

The stability problem of thermoviscoelastic fluid flow between rotating coaxial cylinders is investigated using nonlinear thermoviscoelastic constitutive equations due to Eringen and Koh. The velocity field is found to be identical with that of the classical viscous case and the case of the viscoelastic fluid, but the temperature and pressure fields are found to be different. By imposing some physically reasonable mechanical and geometrical restrictions on the flow, and by a suitable mathematical analysis, the problem is reduced to a characteristic value problem. The resulting problem is solved and stability criteria are obtained in terms of critical Taylor numbers. In general, it is found that thermoviscoelastic fluids are more stable than classical viscous fluids and viscoinelastic fluids under similar conditions.

Ghandour, N. N.↗

Behavior of fluids in a weightless environment

Fluid behavior in a low-g environment is controlled primarily by surface tension forces. Certain fluid and system characteristics determine the magnitude of these forces for both a free liquid surface and liquid in contact with a solid. These characteristics, including surface tension, wettability or contact angle, system geometry, and the relationships governing their interaction, are discussed. Various aspects of fluid behavior in a low-g environment are then presented. This includes the formation of static interface shapes, oscillation and rotation of drops, coalescence, the formation of foams, tendency for cavitation, and diffusion in liquids which were observed during the Skylab fluid mechanics science demonstrations. Liquid reorientation and capillary pumping to establish equilibrium configurations for various system geometries, observed during various free-fall (drop-tower) low-g tests, are also presented. Several passive low-g fluid storage and transfer systems are discussed. These systems use surface tension forces to control the liquid/vapor interface and provide gas-free liquid transfer and liquid-free vapor venting.

Fester, D. A.↗

Automatic fluid dispenser

Fluid automatically flows to individual dispensing units at predetermined times from a fluid supply and is available only for a predetermined interval of time after which an automatic control causes the fluid to drain from the individual dispensing units. Fluid deprivation continues until the beginning of a new cycle when the fluid is once again automatically made available at the individual dispensing units.

Sakellaris, P. C.↗

Fluid velocity measuring device

A fluid velocity measuring device is described which, when placed in a freestream fluid flow, causes vortices to be formed at a frequency proportional to the flow rate of the fluid. Sensors on the device generate electric signals with frequency proportional to the rate of vortex creation and with relative mean amplitudes indicative of fluid flow direction. Electric circuitry translates the electric signals into indications of fluid speed and direction.

Thomas, D. F., Jr.↗

A review of the consequences of fluid and electrolyte shifts in weightlessness

This review describes the renal-endocrine mechanisms related to the early losses of fluid-electrolytes from the body during weightlessness as well as their contribution to longer term adaptation of fluid-electrolyte balance. The hypotheses presented were generated by a systematic analysis of body fluid and renal dynamics observed under conditions of actual and simulated spaceflight. These have increased our understanding of the effects of acute headward fluid shifts on renal excretion, the factors promoting excess sodium excretion and the regulation of extracellular fluid composition.

Leach, C. S.↗

Interactive FORTRAN IV computer programs for the thermodynamic and transport properties of selected cryogens (fluids pack)

The thermodynamic and transport properties of selected cryogens had programmed into a series of computer routines. Input variables are any two of P, rho or T in the single phase regions and either P or T for the saturated liquid or vapor state. The output is pressure, density, temperature, entropy, enthalpy for all of the fluids and in most cases specific heat capacity and speed of sound. Viscosity and thermal conductivity are also given for most of the fluids. The programs are designed for access by remote terminal; however, they have been written in a modular form to allow the user to select either specific fluids or specific properties for particular needs. The program includes properties for hydrogen, helium, neon, nitrogen, oxygen, argon, and methane. The programs include properties for gaseous and liquid states usually from the triple point to some upper limit of pressure and temperature which varies from fluid to fluid.

Mccarty, R. D.↗

Shaded computer graphic techniques for visualizing and interpreting analytic fluid flow models

Mathematical models which predict the behavior of fluid flow in different experiments are simulated using digital computers. The simulations predict values of parameters of the fluid flow (pressure, temperature and velocity vector) at many points in the fluid. Visualization of the spatial variation in the value of these parameters is important to comprehend and check the data generated, to identify the regions of interest in the flow, and for effectively communicating information about the flow to others. The state of the art imaging techniques developed in the field of three dimensional shaded computer graphics is applied to visualization of fluid flow. Use of an imaging technique known as 'SCAN' for visualizing fluid flow, is studied and the results are presented.

Parke, F. I.↗

In vitro Ca-45/++/ uptake and exchange by otoconial complexes in high and low K/+/Na/+/ fluids

Recently, data have been accumulating to indicate that saccular and utricular otoconial complexes of the gravity receptor organs are dynamic and interact constantly with their environment. This study investigates the possibility that the ionic composition of the surrounding fluid influences calcium ion binding and release, and explores the importance of the K(+)/Na(+) ratio. Two in-vitro methods were developed, the first of which employed artificial endolymph and perilymph while ionically balanced fluids in which only the K(+)/Na(+) was altered were used in the second. The ability of rat complexes to take up Ca-45(++) during incubation with these fluids was assessed using liquid scintillation spectrometry. In vitro uptake of Ca-45(++) was greater in fluids with a high K(+)/Na(+) ratio than in fluids in which the ratio was low. The ability of the complexes to take up Ca-45(++) appeared to decline with age.

Ross, M. D.↗

Fluid shifts and muscle function in humans during acute simulated weightlessness

The acute effects of simulated weightlessness on transcapillary fluid balance, tissue fluid shifts, muscle function, and triceps surface reflex time were studied in eight supine human subjects who were placed in a 5 degrees head-down tilt position for 8 hr. Results show a cephalic fluid shift from the legs as indicated by facial edema, nasal congestion, increased urine flow, decreased creatinine excretion, reduced calf girth, and decreased lower leg volume. The interstitial fluid pressure in the tibialis anterior muscle and subcutaneous tissue of the lower leg was found to fall significantly, while other transcapillary pressures (capillary and interstitial fluid colloid osmotic pressures) were relatively unchanged. The total water content of the soleus muscle was unchanged during the head-down tilt. After head-down tilt, isometric strength and isokinetic strength of the plantar flexors were unchanged, while the triceps surae reflex time associated with plantar flexion movement slowed slightly. These results demonstrate a dehydration effect of head-down tilt on muscle and subcutaneous tissue of the lower leg that may affect muscle function.

Hargens, A. R.↗