Search NASA⌕ Search

SEARCH · Search NASA

Results for “bombardment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Performance of a neutralizer for electron bombardment thruster.

Results of the SERT II flight indicate that the hollow cathode neutralizer not only represents a power and propellant weight penalty but can be a contributing cause to accelerator grid erosion. Tests with a 30-cm diameter thruster have shown that a neutralizer position of approximately 9 cm axially downstream of the accelerator grid and approximately 9 cm radially away from the outer edge of the accelerator grid and pointing parallel to the thruster axis provides the best overall performance. The estimated grid wear rate was less than 0.08 mm in 10,000 hr. The coupling voltage (neutralizer to beam voltage) was approximately 17 volts at a neutralizer flow rate of 22 equivalent milliamperes of mercury and a beam current of 1.5 amperes. Neutralizer power (excluding heaters) was 31 watts and the effect of neutralizer flow on overall propellant utilization efficiency is a 1.2 percentage point reduction at a thruster utilization efficiency of 90 percent.

Bechtel, R. T.↗

Calculation of the lunar photon albedo from galactic and solar proton bombardment.

The lunar photon albedo due to cosmogenic and primordial photon sources has been calculated. The individual photon leakage spectra from prompt photons produced by galactic cosmic ray (GCR) and solar cosmic ray (SCR) induced nuclear interactions, from the decay of GCR- and SCR-induced radionuclides, and from the decay of naturally occurring radionuclides are given. An approximate estimate of the leakage from the photon-electron cascade initiated by the decay of neutral pions is also given. Monte Carlo methods have been used to determine the nucleon-meson cascade, and discrete-ordinates methods were used for the photon and low-energy neutron transport.

Armstrong, T. W.↗

Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗

Damage of thermal control coating properties by energetic mercury ion bombardment.

The thermophysical properties (absorptance and emittance) of five commonly used spacecraft thermal control coatings have been measured in situ after exposure to 1.5 and 3 KeV mercury ions. Sample temperature was varied from 20 to 150 C. The results showed negligible change in emittance but significant degradation of the solar absorptance at fluences of 10 to the 17th power ions/sq cm. Plots of absorptance as a function of ion fluence are presented, along with pre- and post-exposure ex situ spectral absorptance measurements. The widely used Z93 white paint exhibited quantitative degradation from mercury ions similar to that reported by other experimenters for hydrogen and helium ions.

Kelley, L. R.↗

A 30-cm diameter bombardment thruster with a variable magnetic baffle.

Thruster performance and stability over a range of beam currents is a function of the hollow cathode propellant flow which depends in part on the baffle geometry. Variable magnetic baffles have been used to allow a change in baffle geometry to improve thruster performance and stability. Test results of a 30-cm thruster with magnetic baffle are presented. Thruster performance characteristics are analyzed to show how the magnetic baffle field strength can improve performance at a fixed beam current, as well as increase the range of ion beam current for throttling.

Bechtel, R. T.↗

A 2000-Hour Durability Test of a 5-Centimeter Diameter Mercury Bombardment Ion Thruster

A 2000-hour durability test of a modified Hughes SIT-5 (Structurally Integrated Thruster, 5 cm) was conducted at the Lewis Research Center. The thruster operated with a translating screen thrust vector grid locked in position for 10 deg beam deflection. The test was essentially continuous except for seven stoppages of beam current. The neutralizer keeper voltage and thruster floating potential increased slightly with time. Performance profiles and maps of thruster characteristics were obtained at 453 and 2023 hours into the test. Overall efficiency was nearly constant at 31 - 32 percent, and operating characteristics were similar at both points in the test. A post-shutdown inspection showed negligible erosion damage to the accelerator and cathode baffle. Some erosion was found in the aperture of the neutralizer cathode.

Nakanishi, S.↗

Control of a 30 cm diameter mercury bombardment thruster

Control logic functions were established for three automatic modes of operation of a 30-cm thruster using a power conditioner console with flight-like characteristics. The three modes provide: (1) automatic startup to reach thermal stability, (2) steady-state closed-loop control, and (3) the reliable recycling of the high voltages following an arc breakdown to reestablish normal operation. Power supply impedance characteristics necessary for stable operation and the effect of the magnetic baffle on the reliable recycling was studied.

Terdan, F. F.↗

A hollow cathode neutralizer for a 30-cm diameter bombardment thruster

Recent improvements in overall thruster performance have imposed new constraints on neutralizer performance. The use of compensated grid extraction system requires a reevaluation of neutralizer position. A series of tests were conducted to determine what effect neutralizer cathode geometry has on performance. The parameters investigated included orifice diameter and length, and cathode diameter. Similar tests investigated open and enclosed keeper geometries. Neutralizer position tests with compensated grids suggested positions approximately 10 cm from the accelerator and radially out of the beam envelope should result in satisfactory performance and long life. Operation at keeper current of 1.5 am resulted in lower total neutralizer power, the elimination of tip heater power, and suitable closed loop control of the neutralizer vaporizer.

Bechtel, R. T.↗

Quantitative multielement analysis using high energy particle bombardment

Charged particles ranging in energy from 0.8 to 4.0 MeV are used to induce resonant nuclear reactions, Coulomb excitation (gamma X-rays), and X-ray emission in both thick and thin targets. Quantitative analysis is possible for elements from Li to Pb in complex environmental samples, although the matrix can severely reduce the sensitivity. It is necessary to use a comparator technique for the gamma-rays, while for X-rays an internal standard can be used. A USGS standard rock is analyzed for a total of 28 elements. Water samples can be analyzed either by nebulizing the sample doped with Cs or Y onto a thin formvar film or by extracting the sample (with or without an internal standard) onto ion exchange resin which is pressed into a pellet.

Clark, P. J.↗

A hollow cathode neutralizer for a 30-cm diameter bombardment thruster

Recent improvements in overall thrustor performance have imposed new constraints on neutralizer performance. The use of compensated grid extraction system requires a re-evaluation of neutralizer position. In addition a suitable control logic for the neutralizer has proven difficult. A series of tests were conducted to determine what effect neutralizer cathode geometry has on performance. The parameters investigated included orifice diameter and length, and cathode diameter. Similar tests investigated open and enclosed keeper geometries. Neutralizer position tests with compensated grids suggest positions approximately 10 cm from the accelerator and radially out of the beam envelope should result in satisfactory performance and long life. Finally operation at keeper currents of 1.5 amp has resulted in lower total neutralizer power, the elimination of tip heater power, and suitable closed loop control of the neutralizer vaporizer.

Bechtel, R. T.↗

Control of a 30 cm diameter mercury bombardment thruster

Increased thruster performance has made closed-loop automatic control more difficult than previously. Specifically, high perveance optics tend to make reliable recycling more difficult. Control logic functions were established for three automatic modes of operation of a 30-cm thruster using a power conditioner console with flight-like characteristics. The three modes provide (1) automatic startup to reach thermal stability, (2) steady-state closed-loop control, and (3) the reliable recycling of the high voltages following an arc breakdown to reestablish normal operation. Power supply impedance characteristics necessary for stable operation and the effect of the magnetic baffle on the reliable recycling was studied.

Terdan, F. F.↗

Operating characteristics of a hollow-cathode neutralizer for 5 and 8 centimeter-diameter electron bombardment mercury ion thrusters

Thin-tip 0.3-cm-outside-diameter hollow-cathode neutralizers were used to investigate causes of neutralizer tip erosion experienced in thruster endurance tests. Bell-jar tests indicated that neutralizers with new rolled tantalum foil inserts coated with an emissive mixture eroded very little over the neutral flow rates investigated (3 to 10 mA) for simulated 5- and 8-cm-diameter thruster neutralizer conditions. Tip erosion rates of neutralizers operated with no insert or emissive mixture increased by two orders of magnitude for both configurations as the neutral flow rate decreased. Spectroscopic analysis of the discharge plasma from neutralizers operated with inserts coated with the emissive mixture detected tungsten at all neutral flow rates for both thruster neutralizer conditions. The only source of tungsten was the tip. Therefore, detection of tungsten indicated neutralizer tip erosion. Barium, an element of the emissive mixture, was detected at low neutral flow rates for the 5-cm-diameter thruster neutralizer operating condition only.

Weigand, A. J.↗

Theoretical investigations of plasma processes in the ion bombardment thruster

A physical model for a thruster discharge was developed, consisting of a spatially diverging plasma sustained electrically between a small ring cathode and a larger ring anode in a cylindrical chamber with an axial magnetic field. The associated boundary-value problem for the coupled partial differential equations with mixed boundary conditions, which describe the electric potential and the plasma velocity fields, was solved in closed form. By means of quantum-mechanical perturbation theory, a formula for the number S(E) of atoms sputtered on the average by an ion of energy E was derived from first principles. The boundary-value problem describing the diffusion of the sputtered atoms through the surrounding rarefied electron-ion plasma to the system surfaces of ion propulsion systems was formulated and treated analytically. It is shown that outer boundary-value problems of this type lead to a complex integral equation, which requires numerical resolution.

Wilhelm, H. E.↗

An experimental investigation of multiple ion processes in mercury bombardment thrusters

Utilizing a collimated E x B mass separator probe, the ratio of double to single ion current densities has been measured in the beam of a 30 cm ion thruster over a wide range of beam and discharge conditions. For a specified thruster geometry, the mass utilization efficiency has been found to be the governing parameter in the determination of the doubly-charged ion content. By a reduction in the open area of the accelerator grid, a reduction in the doubly-charged ion ratio could be achieved while maintaining overall efficiency constant. The results are examined in terms of ion densities and neutral loss rates.

Vahrenkamp, R.↗

A 15,000-hour cyclic endurance test of an 8-centimeter-diameter electron bombardment mercury ion thruster

A laboratory model 8 cm thruster with improvements to minimize ion chamber erosion and peeling of sputtered metal was subjected to a cyclic endurance test for 15,040 hours and 460 restarts. A charted history of several thruster operating variables and off-normal events are shown in 600-hour segments at three points in the test. The transient behavior of these variables during a typical start-stop cycle is presented. Finding of the post-test inspection confirmed most of the expected results. Charge exchange ions caused normal accelerator grid erosion. The workability of the various design features was substantiated, and attainable improvements in propellant utilization efficiency should significantly reduce accelerator erosion.

Nakanishi, S.↗