Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy’s National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real- time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI’s Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: 1. Run in real-time on the edge (≥ 12 Hz) 2. Classification: Achieve less than 5% false positive detection 3. Classification: Achieve ≥ 95% methane plume detection rate 4. Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Comparison of High Level Waste Glass Feeds Containing Frit and Glass Forming Chemicals - 16154

This study compares the impact of frit and glass forming-chemicals on high level waste feed melting behavior. Feeds formulated to yield high-boron (lower waste loading) and low-boron (higher waste loading) glass compositions were prepared by blending a simulated high-level waste with glass-forming additives either in the form of chemicals or pre-melted as glass frit. The feeds were pressed into cylindrical disc-shaped pellets using a die tool and a hydraulic press. Each pellet was heat-treated in a high-temperature furnace equipped with a window to view the pellet's response to increasing temperature, usually up to 1100 deg. C, until the pellet turned into a molten glass droplet. A camera mounted in front of the viewing window was used to take high-quality pictures at predetermined intervals. Images were analyzed using a program that calculated the pellet profile area and volume as functions of temperature. The analyses are used to determine characteristic temperatures and associated volume expansions including foam onset and collapse. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring Operational Safeguards, Safety, and Security by Design to Address Real Time Threats in Nuclear Facilities

Over the last few years, significant attention has been paid to both encourage application and provide domestic and international guidance for designing in safeguards and security in new facilities.1,2,3 However, once a facility is operational, safeguards, security, and safety often operate as separate entities that support facility operations. This separation is potentially a serious weakness should insider or outsider threats become a reality.Situations may arise where safeguards detects a possible loss of material in a facility. Will they notify security so they can, for example, check perimeter doors for tampering? Not doing so might give the advantage to an insider who has already, or is about to, move nuclear material outside the facility building. If outsiders break into a facility, the availability of any information to coordinate the facility’s response through segregated alarm stations or a failure to include all available radiation sensors, such as safety’s criticality monitors can give the advantage to the adversary who might know to disable camera systems, but would most likely be unaware of other highly relevant sensors in a nuclear facility.This paper will briefly explore operational safeguards, safety, and security by design (3S) at a high level for domestic and State facilities, identify possible weaknesses, and propose future administrative and technical methods, to strengthen the facility system’s response to threats.

Schanfein, Mark J.↗

Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Land-surface studies with a directional neutron detector.

Direct measurements of cosmic-ray neutron intensity were recorded with a neutron scatter camera developed at SNL. The instrument used in this work is a prototype originally designed for nuclear non-proliferation work, but in this project it was used to characterize the response of ambient neutrons in the 0.5-10 MeV range to water located on or above the land surface. Ambient neutron intensity near the land surface responds strongly to the presence of water, suggesting the possibility of an indirect method for monitoring soil water content, snow water equivalent depth, or canopy intercepted water. For environmental measurements the major advantage of measuring neutrons with the scatter camera is the limited (60{sup o}) field of view that can be obtained, which allows observations to be conducted at a previously unattainable spatial scales. This work is intended to provide new measurements of directional fluxes which can be used in the design of new instruments for passively and noninvasively observing land-surface water. Through measurements and neutron transport modeling we have demonstrated that such a technique is feasible.

54 ENVIRONMENTAL SCIENCES↗

"Postage-Stamp PIV:" Small Velocity Fields at 400 kHz for Turbulence Spectra Measurements

Time-resolved particle image velocimetry recently has been demonstrated in high-speed flows using a pulse-burst laser at repetition rates reaching 50 kHz. Turbulent behavior can be measured at still higher frequencies if the field of view is greatly reduced and lower laser pulse energy is accepted. Current technology allows image acquisition at 400 kHz for sequences exceeding 4,000 frames, but for an array of only 128 x 120 pixels, giving the moniker of "postage-stamp PIV." The technique has been tested far downstream of a supersonic jet exhausting into a transonic crossflow. Two-component measurements appear valid until 120 kHz at which point a noise floor emerges whose magnitude is dependent on the reduction of peak locking. Stereoscopic measurement offers three-component data for turbulent kinetic energy spectra, but exhibits a reduced signal bandwidth and higher noise in the out-of-plane component due to the oblique camera images. The resulting spectra reveal two regions exhibiting power-law dependence describing the turbulent decay. In conclusion, the frequency response of the present measurement configuration exceeds nearly all previous velocimetry measurements in high speed flow.

47 OTHER INSTRUMENTATION↗

Characterization of good teleoperators - What aptitudes, interests, and experience correlate with measures of teleoperator performance

The use of aptitude tests and questionnaries to evaluate an individuals aptitude for teleoperation is studied. The Raven Progressive Matrices Test and Differential Aptitude Tests, and a 16-item questionnaire for assessing the subject's interests, academic background, and previous experience are described. The Proto-Flight Manipulator Arm, cameras, console, hand controller, and task board utilized by the 17 engineers are examined. The correlation between aptitude scores and questionnaire responses, and operator performance is investigated. Multiple regression data reveal that the eight predictor variables are not individually significant for evaluating operator performance; however, the complete test battery is applicable for predicting 49 percent of subject variance on the criterion task.

Yorchak, J. P.↗

Algorithms For Detection Of Correlation Spots

Three algorithms provide for improved postprocessing of outputs of optical correlators based on binary phase-only filters. Detect correlation spots. Function in presence of noise and executed rapidly. First algorithm starts processing correlation-image data while data fed out of video camera and digitized for subsequent analysis. Second involves convolution of correlation image with small-window two-dimensional impulse-response function followed by threshold operation in which negative values of convolution integral set to zero. Third affects generation as well as postprocessing of correlation image.

Scholl, Marija S.↗

Applications of Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paint is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Liu, Tian-Shu↗

Pressure and Temperature Sensitive Paint Measurements on Rotors

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John↗

Boundary-Layer Transition Detection in Cryogenic Wind Tunnel Using Fluorescent Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paints is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Sullivan, John↗

Evaluating the Performance of Unmanned Ground Vehicle Water Detection

Water detection is a critical perception requirement for unmanned ground vehicle (UGV) autonomous navigation over cross-country terrain. During the Robotics Collaborative Technology Alliances (RCTA) program, the Jet Propulsion Laboratory (JPL) developed a set of water detection algorithms that are used to detect, localize, and avoid water bodies large enough to be a hazard to a UGV. The JPL water detection software performs the detection and localization stages using a forward-looking stereo pair of color cameras. The 3D coordinates of water body surface points are then output to a UGV's autonomous mobility system, which is responsible for planning and executing safe paths. There are three primary methods for evaluating the performance of the water detection software. Evaluations can be performed in image space on the intermediate detection product, in map space on the final localized product, or during autonomous navigation to characterize the avoidance of a variety of water bodies. This paper describes a methodology for performing the first two types of water detection performance evaluations.

stereo vision↗

Precision Photometry to Study the Nature of Dark Energy

Over the past decade scientists have collected convincing evidence that the expansion of the universe is accelerating, leading to the conclusion that the content of our universe is dominated by a mysterious 'dark energy'. The fact that present theory cannot account for the dark energy has made the determination of the nature of dark energy central to the field of high energy physics. It is expected that nothing short of a revolution in our understanding of the fundamental laws of physics is required to fully understand the accelerating universe. Discovering the nature of dark energy is a very difficult task, and requires experiments that employ a combination of different observational techniques, such as type-Ia supernovae, gravitational weak lensing surveys, galaxy and galaxy cluster surveys, and baryon acoustic oscillations. A critical component of any approach to understanding the nature of dark energy is precision photometry. This report addresses just that. Most dark energy missions will require photometric calibration over a wide range of intensities using standardized stars and internal reference sources. All of the techniques proposed for these missions rely on a complete understanding of the linearity of the detectors. The technical report focuses on the investigation and characterization of 'reciprocity failure', a newly discovered count-rate dependent nonlinearity in the NICMOS cameras on the Hubble Space Telescope. In order to quantify reciprocity failure for modern astronomical detectors, we built a dedicated reciprocity test setup that produced a known amount of light on a detector, and to measured its response as a function of light intensity and wavelength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Magnetohydrodynamics and Heat Transfer in a Free-Surface, Flowing Liquid Metal Experiment

This thesis examines magnetohydrodynamic (MHD) effects and heat transfer in free-surface, liquid metal flow. The interaction of the flow with the applied magnetic field introduces an anisotropy to the fluid motion, resulting in starkly different behavior depending on the orientation and strength of the applied magnetic field. The transition from a hydrodynamic state to an MHD state was experimentally found to be characterized by the interaction parameter, N = &sigma L B 2 /&rho v0 , crossing above 0.5. The experiment consisted of a channel 1 m in length, up to 16 cm in width and 1 to 2.5 cm in depth situated within an electromagnet capable of producing a uniform magnetic field up to 2.7 kG. The fluid velocity was measured with an array of 25 potential probes that resolved the spanwise velocity profile, while waves on the surface of the metal were monitored via a diagnostic that tracked the motion of a laser beam reflected off of the free surface. Lastly, the temperature response of the fluid was recorded with an array of 32 thermocouples embedded in the bottom of the channel and a mid-wavelength infrared camera used to image the free surface. Three distinct sets of experiments were performed to investigate the effects of the applied magnetic field on the dynamics within the flow, studying: 1) changes to vortices in the wake of a cylinder, 2) behavior of surface fluctuations due to the turbulent flow, and 3) vertical heat transfer resulting from heat deposition on the free surface. The first set of experiments examined the wake of a cylinder inserted into the flow with its axis parallel to the magnetic field. Measurements with the potential probes indicated that vortices in the wake became laminarized as the field was increased due to the alignment of the injected vorticity with the applied field. The second set of experiments showed that surface fluctuations were suppressed at high magnetic fields, but the precise nature of the damping depended on the orientation of the applied field. Lastly, when heat was injected at the free surface via a resistive heater, the temperature response of the fluid was found to vary considerably depending on the strength and direction of the applied field. In all experiments, it was observed that the angle between the vorticity of structures in the flow and the applied magnetic field dictated the macroscopic behavior of the fluid. This work provides the first experimental results of several phenomena associated with free-surface, liquid metal flows in an applied magnetic field. Further, the results have direct implications for proposed flowing liquid metal divertors for fusion reactors, and offer insight into the nature of turbulent MHD flows.

fusion↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Salathe, Marco↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Prins, Nicholas↗

Narrow-band radiation wavelength measurement by processing digital photographs in RAW format

The technique of measuring the mean wavelength of narrow-band radiation in the 455 - 625-nm range using the image of the emitting surface is presented. The data from the camera array unprocessed by the built-in processor (RAW format) are used. The method is applied for determining the parameters of response of holographic sensors. Depending on the wavelength and brightness of the image fragment, the mean square deviation of the wavelength amounts to 0.3 - 3 nm. (experimental techniques)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗