Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ITL (InterfaceLimits.jl) [SWR-23-56]

Network flow of electrical power is governed by Kirchhoff's laws which make calculating the power transfer capacity across interfaces connecting groups of nodes complex. This package leverages the capabilities of Sienna\Data to build and solve interface limit calculation problems.

Barrows, Clayton↗

Agrivoltaics: Solar Farming for a Greener Future

Resilient, secure, diversified, and disaster-hardened energy systems are critical to Puerto Rico's clear energy future. This presentation builds on NREL's PR100 One Year Progress Summary Report, discussing the intersection of land availability, PV capacity growth, and the potential role of agrivoltaics in contributing to Puerto Rico's 100% renewable energy goal and agricultural sector resilience. An overview of the state-of-the-science in agrivoltaics is provided, including the NREL InSPIRE Puerto Rican pilot project on hurricane-resistant, shade-grown agrivoltaic coffee. Agrivoltaics is discussed in the context of food-energy resilience for island nations, and future research & development needs are highlighted.

agrivoltaics↗

Commercial Building Planning and Retrofitting Strategy for Grid Services

The increasing integration of distributed energy resources (DERs) plays an important role in improving energy consumption efficiency. In September 2020, the Federal Energy Regulatory Commission (FERC) approved Order 2222 which opens wholesale electricity markets to small capacity DERs. The benefit of this new FERC Order 2222 is that DERs, such as rooftop solar panels and batteries, will be able to participate in regional electricity markets and provide grid services. Meanwhile, the planning and operation strategies of DERs are facing new challenges to account for the impact of the wholesale market with numerous uncertainty factors. Therefore, in this paper, we propose a new planning and retrofitting model for long-term commercial buildings that considers both DER investment and market participation. Specifically, we explore the capability of implementing DERs for grid services. The effectiveness of the proposed model is validated using real-world data. Simulation results also validate that participating in grid services can significantly increase revenues through appropriate building energy management and shorten the payback period of DER investments.

building energy management↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

Toward the Practical Use of Cobalt-Free Lithium-Ion Batteries by an Advanced Ether-Based Electrolyte

The criticality of cobalt (Co) has been motivating the quest for Co-free positive electrode materials for building lithium (Li)-ion batteries. However, the Co-free positive electrode materials usually suffer from relatively fast capacity decay when coupled with conventional LiPF 6 -organocarbonates electrolytes. To address this issue, a 1,2-dimethoxyethane (DME) based localized high concentration electrolyte (LHCE) was developed and evaluated in a Co-free Li-ion cell chemistry (Graphite||LiNi 0.96 Mg 0.02 Ti 0.02 O 2 ). Extraordinary capacity retentions were achieved with the LHCE in coin cells (95.3%), single layer pouch cells (79.4%) and high capacity loading double layer pouch cells (70.9 %) after being operated within the voltage range of 2.5-4.4 V for 500 charge/discharge cycles. The capacity retentions of counterpart cells using LiPF6 based conventional electrolyte only reached 61.1%, 57.2% and 59.8%, respectively. Mechanistic studies reveal that the superior electrode/electrolyte interphases formed by the LHCE and the intrinsic chemical stability of the LHCE account for the excellent electrochemical performance in the Co-free Li-ion cells.

25 ENERGY STORAGE↗

A Cation-Tethered Flowable Polymeric Interface for Enabling Stable Deposition of Metallic Lithium

A fundamental challenge, shared across many energy storage devices, is the complexity of electrochemistry at the electrode–electrolyte interfaces that impacts the Coulombic efficiency, operational rate capability, and lifetime. Specifically, in energy-dense lithium metal batteries, the charging/discharging process results in structural heterogeneities of the metal anode, leading to battery failure by short-circuit and capacity fade. In this work, we take advantage of organic cations with lower reduction potential than lithium to build an electrically responsive polymer interface that not only adapts to morphological perturbations during electrodeposition and stripping but also modulates the lithium ion migration pathways to eliminate surface roughening. As a result, we find that this concept can enable prolonging the long-term cycling of a high-voltage lithium metal battery by at least twofold compared to bare lithium metal.

25 ENERGY STORAGE↗

Magnetic field-temperature phase diagram of the spin-$\frac{1}{2}$ triangular lattice antiferromagnet KYbSe 2

A quantum spin liquid (QSL) is a state of matter characterized by fractionalized quasiparticle excitations, quantum entanglement, and a lack of long-range magnetic order. However, QSLs have evaded definitive experimental observation. Several Yb 3+ -based triangular lattice antiferromagnets with effective 𝑆 = $\frac{1}{2}$ have been suggested to stabilize the QSL state as the ground state. Here, in this work, we build a comprehensive magnetic temperature phase diagram of a high-quality single crystalline KYbSe 2 via heat capacity and magnetocaloric effect down to 30 mK with magnetic field applied along the 𝑎 axis. At zero magnetic field, we observe the magnetic long-range order at 𝑇 N =0.29 K entering 120 degrees ordered state in heat capacity, consistent with neutron scattering studies. Analysis of the low-temperature (𝑇) specific heat (𝐶) at zero magnetic field indicates linear 𝑇 dependence of 𝐶/𝑇 and a broad hump of 𝐶/𝑇 in the proximate QSL region above 𝑇 N . By applying magnetic field, we observe the up-up-down phase with 1/3 magnetization plateau and oblique phases, in addition to two new phases. These observations strongly indicate that while KYbSe 2 closely exhibits characteristics resembling an ideal triangular lattice, deviations may exist, such as the effect of the next-nearest-neighbor exchange interaction, calling for careful consideration for spin Hamiltonian modeling. Further investigations into tuning parameters, such as chemical pressure, could potentially induce an intriguing QSL phase in the material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physical Properties of Hilti HIT-RE 500 V3 After Irradiation: Slant Shear, Tensile, Flexural, and Compressive

There are various applications in which epoxy adhesives may be used within hot-cell environments. These epoxies currently see limited use within hot cells since it is known that organics see degradation after small doses even as low as 50 kilogray (kGy). These losses in physical property strengths limit the use of these epoxies to non-structural applications. In modern construction, however, the use of epoxies to bond structural components such as rebar or threaded anchors is becoming increasingly prevalent. To employ these types of materials the Idaho National Laboratory (INL) has begun investigating the specific degradation properties of epoxies for use in structural applications in environments where radiation is present. Hilti HIT-RE 500 V3 is used extensively in new construction and renovation projects across the world. The INL has conducted various tests on this epoxy for low dose environments. These tests include tensile, flexural, compression, and slant shear tests following the American Society for Testing Material International (ASTM) standards D638, D790, D695, and C882/882M respectively. Two sample sets for each test were created where the baseline specimens were not irradiated, and another set was irradiated to an accumulated dose of approximately 50-60 kGy. All the samples were destructively tested and analyzed focusing on the change in physical properties, examples of these tests are shown in Figures 1-4. Tensile testing results indicate a 0.9% loss in maximum load capacity, a 0.5% loss in tensile stress at maximum load, a 1.4% loss in tensile strain at break, and a 15% decrease in modulus of elasticity. Flexural testing results display an increase in all the following: 12% in strain at maximum load, 10% in maximum load capacity, 5% in stress at maximum load, and 3% in young’s modulus. The compressive physical properties after irradiation display a 1% increase in maximum load, a 3% decrease in stress at yield, and a 5% decrease in modulus of elasticity. The maximum compressive stress saw no measurable change after irradiation. The slant shear specimens after irradiation displayed a 2% increase in maximum load capacity and maximum compressive stress. Though a structural analysis would have to be completed as is normal for building design the increases and decreases in the measured physical properties indicate that this material may be used for structural applications in low dose hot-cell environments without adhesive failure.

36 MATERIALS SCIENCE↗

Consumer Benefits of Clean Energy: Energy Efficiency

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief focuses on energy efficiency benefits, and builds on prior analysis from Berkeley Lab’s Cost of Saved Energy database. We show that energy efficiency remains a low-cost energy and capacity resource; the levelized cost of saving energy for the programs included in the analysis is $\$0.02$/kilowatt-hour and the cost of saving peak demand is less $\$120$/kilowatt. Understanding the impact of the program mix, portfolio size, and duration of implementation for customer-funded energy efficiency portfolios can guide regulatory oversight of these programs, help utilities better utilize energy efficiency as a resource, and inform building energy decarbonization policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Highly silanized cellulose biocomposites for sustainable insulation materials

Microfibrillated lignocellulose networks, derived from agricultural byproducts, represent an environmentally friendly biogenic material production due to their abundant availability to circular bioeconomy and inherent carbon sink in life cycle analysis. Yet, its vulnerability to moisture and flammability, coupled with challenges in creating highly reinforced insulation materials, poses challenges for the carbon-zero green building sector. Here we address these challenges with a new concept of in-situ grafting polymerization of nanoporous silica in pre-formed lignocellulosic fiber networks. The seamlessly integrating nanoporous silica with cellulose through hydrogen bonding networks enabled us to prepare highly reinforced biogenic composites for green building insulations. A high reinforcement biocomposite with hierarchal arrangements of nanoporous silica within the cellulose network exhibits remarkable attributes. It boasts a thermal conductivity of 24.2 mW·m –1 ·K –1 , a flexural modulus of 942 MPa, and soundproofing with a 20.8 % noise reduction, as well as the fire resistance characterized by an extended time to ignition and a reduced peak heat release rate of 144 kW·m –2 at 35 kW·m –2 of incident radiant heat flux. Furthermore, it demonstrates a reduced water absorption capacity, dropping from 5.12 g·g –1 to 0.75 g·g –1 . Altogether, this study opens the new pathways towards sustainable carbon-zero building materials in the context of circular bioeconomy.

36 MATERIALS SCIENCE↗

Photoinduced Dynamics with Constrained Vibrational Motion: FrozeNM Algorithm

Ab initio molecular dynamics (AIMD) simulation, analyzed in terms of vibrational normal modes, is a widely used technique that facilitates understanding of complex structural motions and coupling between electronic and nuclear degrees of freedom. Usually, only a subset of vibrations is directly involved in the process of interest. The impact of these vibrations can be evaluated by performing AIMD simulations by selectively freezing certain motions. In this paper, we present frozen normal mode (FrozeNM), a new algorithm to apply normal-mode constraints in AIMD simulations, as implemented in the nonadiabatic excited state molecular dynamics code. We further illustrate its capacity by analyzing the impact of normal-mode constraints on the photoinduced energy transfer between polyphenylene ethynylene dendrimer building blocks. Our results show that the electronic relaxation can be significantly slowed down by freezing a well-selected small subset of active normal modes characterized by their contributions in the direction of energy transfer. The application of these constraints reduces the nonadiabatic coupling between electronic excited states during the entire dynamical simulations. Furthermore, we validate reduced dimensionality models by freezing all the vibrations, except a few active modes. Altogether, we consider FrozeNM as a useful tool that can be broadly used to underpin the role of vibrational motion in a studied process and to formulate reduced models that describe essential physical phenomena.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electric Grid Supply Chain Review: Large Power Transformers and High Voltage Direct Current Systems

The report “America’s Strategy to Secure the Supply Chain for a Robust Clean Energy Transition” lays out the challenges and opportunities faced by the United States in the energy supply chain as well as the federal government plans to address these challenges and opportunities. It is accompanied by several issue-specific deep dive assessments, including this one, in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. The need to modernize and increase the capacity of the U.S. power grid is increasing due to growing population, aging infrastructure, grid resilience requirements, operational flexibility needs, and a growing portfolio of renewable energy. As part of the Paris Climate Agreement the United States has committed to reducing its net greenhouse gas emissions by 50 to 52 percent below 2005 levels in 2030 and has set a goal of 100 percent carbon pollution free electricity by 2035 (The United States of America Nationally Determined Contribution, 2021). Meeting these targets will require a significant expansion of the power system to integrate a large amount of new renewable resources (United States Department of State & United States Executive Office of the President, 2021). However, many critical components supporting the power grid have limited to no domestic manufacturing capacity and face complex challenges in supporting a rapid expansion of the grid to meet multiple objectives, including decarbonization goals. This report focuses on two key grid components: large power transformers (LPTs) and high-voltage direct current (HVDC) transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗