Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL, a miniaturized two-phase fluid circulator for thermally linking cryogenic cooling sources to remote cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Design and Testing of a Cryogenic Capillary Pumped Loop Flight Experiment

This paper details the flight configuration and pre-flight performance test results of the fifth generation cryogenic capillary pumped loop (CCPL-5). This device will fly on STS-95 in October 1998 as part of the CRYOTSU Flight Experiment. This flight represents the first in-space demonstration of a CCPL; a miniaturized two-phase fluid circulator for thermally linking cryogenic components. CCPL-5 utilizes N2 as the working fluid and has a practical operating range of 75-110 K. Test results indicate that CCPL-5, which weighs about 200 grams, can transport over 10 W of cooling a distance of 0.25 m (or more) with less than a 5 K temperature drop.

Bugby, David C.↗

Flight Testing of a Cryogenic Capillary Pumped Loop

This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 80K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment. The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5 W as well as with parasitic heat loads alone.

Ku, Jentung↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

Capillary Pressure Balance with Repeated Head-Up Tilt in Humans

We measured blood density (BD). plasma density (PD) and hematocrit (Ht) during repeated 70 deg head-up tilt (HUT) consisting of a pre-drink period with two supine (P and P3) and two HUT (P2 and P4) phases of 45 min each. At the end of P4 test subjects (N=8) drank 10 ml/kg body weight of isotonic (290 mOsm/kg) sodium chloride (ISO) or hypotonic (<10 mOsm/kg) unsweetened us (HYP), or nothing (control: CON). The following periods continued the supine (P5, P7) / upright (P6) sequence. Mass density of plasma and whole blood using a "mechanical oscillation" technique were measured from ear lobe blood. Tilting altered (p<0.001) BD, PD, and Ht in all consecutive Phases. BD and PD were different (p<0.05) between CON. HYP. and ISO Phases 6 and 7. The computed mass density of fluid (FD). which moved between intra. and extravascular compartments. averaged 1008 g/l and was the same in any conditions. In the non-drink treatment (P3, P5, P7), supine PV steadly decreased when compared to P1. Tilt-induced PV shifts ranged from 9.7 to 16.7% when compared to PV du. ring the respective previous Phases. After drinking, PV increased above CON values at the end of Phase 7 by 12.9% with ISO, and by 6.6% with HYP. Progressive hemoconcentration. occurred during non-drink supine; isotonic saline ingestion increased supine PV a control level but did not stop or reverse the decrease of upright hemoconcentration. Upright density values were not slowed with repeated upright tilting; decreased fluid loss occurred in consecutive upright periods. Upright capillary pressure balance was achieved with diminished plasma volume loss during repeated tilting.

Hinghofer-Szalkay, H. G.↗

Loop Heat Pipes and Capillary Pumped Loops: An Applications Perspective

Capillary pumped loops (CPLS) and loop heat pipes (LHPS) are versatile two-phase heat transfer devices which have recently gained increasing acceptance in space applications. Both systems work based on the same principles and have very similar designs. Nevertheless, some differences exist in the construction of the evaporator and the hydro-accumulator, and these differences lead to very distinct operating characteristics for each loop. This paper presents comparisons of the two loops from an applications perspective, and addresses their impact on spacecraft design, integration, and test. Some technical challenges and issues for both loops are also addressed.

Butler, Dan↗

Comprehensive Testing of a Neon Cryogenic Capillary Pumped Loop

This paper describes a comprehensive test program of a cryogenic capillary pumped loop (CCPL) using neon as the working fluid in the temperature range between 30 K and 40 K. The test article was originally designed to be used with nitrogen in the 70 K to 100 K temperature range, and was refurbished for testing with neon. Tests performed included start up from a supercritical state, power cycle, sink temperature cycle, heat transport limit, low power limit, reservoir set point change and long duration operation. The neon CCPL has demonstrated excellent performance under various conditions.

Kobel, Mark C.↗

A Brief Analysis of Capillary Sealing Methods and Their Effectiveness

Protein crystals and the solutions from which they are grown need to be carefully protected against dehydration. In absence of a proper seal, the crystals will dehydrate and lose their original properties, among these the ability to diffract X-rays. We conducted a systematic study of the efficacy of the most common sealing materials in use and we report the results here. The study shows that no single material is completely effective in both untreated and silanized glass capillaries. Various combinations of two materials, however, give excellent seals that will prevent dehydration for long periods of time. Recommendations are made for sealing materials to be used.

Curreri, Peter A.↗

Microscale Investigation of Thermo-Fluid Transport in the Transition FIL, Region of an Evaporating Capillary Meniscus Using a Microgravity Environment

In order to enhance the fundamental understanding of thin film evaporation and thereby improve the critical design concept for two-phase heat transfer devices, microscale heat and mass transport is to be investigated for the transition film region using state-of-the-art optical diagnostic techniques. By utilizing a microgravity environment, the length scales of the transition film region can be extended sufficiently, from submicron to micron, to probe and measure the microscale transport fields which are affected by intermolecular forces. Extension of the thin film dimensions under microgravity will be achieved by using a conical evaporator made of a thin silicon substrate under which concentric and individually controlled micro-heaters are vapor-deposited to maintain either a constant surface temperature or a controlled temperature variation. Local heat transfer rates, required to maintain the desired wall temperature boundary condition, will be measured and recorded by the concentric thermoresistance heaters controlled by a Wheatstone bridge circuit, The proposed experiment employs a novel technique to maintain a constant liquid volume and liquid pressure in the capillary region of the evaporating meniscus so as to maintain quasi-stationary conditions during measurements on the transition film region. Alternating use of Fizeau interferometry via white and monochromatic light sources will measure the thin film slope and thickness variation, respectively. Molecular Fluorescence Tracking Velocimetry (MFTV), utilizing caged fluorophores of approximately 10-nm in size as seeding particles, will be used to measure the velocity profiles in the thin film region. An optical sectioning technique using confocal microscopy will allow submicron depthwise resolution for the velocity measurements within the film for thicknesses on the order of a few microns. Digital analysis of the fluorescence image-displacement PDFs, as described in the main proposal, can further enhance the depthwise resolution.

Kihm, K. D.↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Relationship of echocardiographic indices to pulmonary capillary wedge pressures in healthy volunteers

OBJECTIVES: We sought to determine the relationship between different echocardiographic indices and pulmonary capillary wedge pressures (PCWP) in normal volunteers. BACKGROUND: Indices based on tissue Doppler (TDE) and color M-mode (CMM) echocardiography have been proposed to reflect left (LV) ventricular filling pressures. These include the ratio of early diastolic transmitral velocity (E) to early myocardial velocity measured by TDE (E') and the ratio of E to the wave propagation velocity (Vp) measured from CMM images. These indices, however, have not been validated in normal individuals. METHODS: We studied seven volunteers during two phases of preload altering maneuvers, baseline, with two stages of lower body negative pressure, and repeat baseline with two stages of volume loading. The PCWP obtained from right heart catheterization was compared with diastolic indices using pulsed Doppler, TDE and CMM echocardiography. RESULTS: The PCWP ranged from 2.2 to 23.5 mm Hg. During preload alterations, significant changes in E and septal E' (both p < 0.05) but not lateral E' or Vp were observed. Furthermore, E, septal E' and E/Vp correlated with PCWP (all r > 0.80) but not combined E and TDE indices (both r < 0.15). Within individuals, a similar linear relationship was observed among E/Vp, E and septal E' (average r > 0.80). CONCLUSIONS: In subjects without heart disease, E, septal E' and E/Vp correlate with PCWP. Because the influence of ventricular relaxation is minimized, the ratio E/Vp may be the best overall index of LV filling pressures.

NASA Discipline Cardiopulmonary↗

Microfabricated capillary electrophoresis amino acid chirality analyzer for extraterrestrial exploration

Chiral separations of fluorescein isothiocyanate-labeled amino acids have been performed on a microfabricated capillary electrophoresis chip to explore the feasibility of using such devices to analyze for extinct or extant life signs in extraterrestrial environments. The test system consists of a folded electrophoresis channel (19.0 cm long x 150 microns wide x 20 microns deep) that was photolithographically fabricated in a 10-cm-diameter glass wafer sandwich, coupled to a laser-excited confocal fluorescence detection apparatus providing subattomole sensitivity. Using a sodium dodecyl sulfate/gamma-cyclodextrin pH 10.0 carbonate electrophoresis buffer and a separation voltage of 550 V/cm at 10 degrees C, baseline resolution was observed for Val, Ala, Glu, and Asp enantiomers and Gly in only 4 min. Enantiomeric ratios were determined for amino acids extracted from the Murchison meteorite, and these values closely matched values determined by HPLC. These results demonstrate the feasibility of using microfabricated lab-on-a-chip systems to analyze extraterrestrial samples for amino acids.

NASA Discipline Life Sciences Technologies↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

NASA Discipline Environmental Health↗

Control of intracellular pH and growth by fibronectin in capillary endothelial cells

The aim of this work was to analyze the mechanism by which fibronectin (FN) regulates capillary endothelial cell proliferation. Endothelial cell growth can be controlled in chemically-defined medium by varying the density of FN coated on the substratum (Ingber, D. E., and J. Folkman. J. Cell Biol. 1989. 109:317-330). In this system, DNA synthetic rates are stimulated by FN in direct proportion to its effect on cell extension (projected cell areas) both in the presence and absence of saturating amounts of basic FGF. To investigate direct growth signaling by FN, we carried out microfluorometric measurements of intracellular pH (pHi), a cytoplasmic signal that is commonly influenced by soluble mitogens. pHi increased 0.18 pH units as FN coating densities were raised and cells progressed from round to spread. Intracellular alkalinization induced by attachment to FN was rapid and followed the time course of cell spreading. When measured in the presence and absence of FGF, the effects of FN and FGF on pHi were found to be independent and additive. Furthermore, DNA synthesis correlated with pHi for all combinations of FGF and FN. Ethylisopropylamiloride, a specific inhibitor of the plasma membrane Na+/H+ antiporter, completely suppressed the effects of FN on both pHi and DNA synthesis. However, cytoplasmic pH per se did not appear to be a critical determinant of growth since DNA synthesis was not significantly inhibited when pHi was lowered over the physiological range by varying the pH of the medium. We conclude that FN and FGF exert their growth-modulating effects in part through activation of the Na+/H+ exchanger, although they appear to trigger this system via separate pathways.

NASA Discipline Cell Biology↗

Polymethylmethacrylate (PMMA) Material Test Results for the Capillary Flow Experiments (CFE)

In support of the Capillary Flow Experiments (CFE) program, several polymethylmethacrylate (PMMA) flight vessels were constructed. Some vessels used a multipiece design, which was chemically welded together. Due to questions regarding the effects of the experiment fluid (silicone oil) on the weld integrity, a series of tests were conducted to provide evidence of the adequacy of the current vessel design. Tensile tests were conducted on PMMA samples that were both in the as-received condition, and also aged in air or oil for up to 8 weeks. Both welded and unwelded samples were examined. Fracture of the joints was studied using notched tensile specimens and Brazilian disk tests. Results showed that aging had no effect on tensile properties. While the welded samples were weaker than the base parent material, the weld strength was found to be further degraded by bubbles in the weld zone. Finally a fracture analysis using the worst-case fracture conditions of the vessel was performed, and the vessel design was found to have a factor of three safety margin.

Lerch, Bradley A.↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗