Crystal Growth of Ternary Compound Semiconductors in Low Gravity Environment

A low gravity material experiment will be performed in the Material Science Research Rack (MSRR) on International Space Station (ISS). There are two sections of the flight experiment: (I) crystal growth of ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, by physical vapor transport (PVT) and (II) melt growth of CdZnTe by directional solidification. The main objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the grown crystals as results of buoyancy-driven convection and growth interface fluctuations caused by irregular fluid-flows on Earth. The investigation consists of extensive ground-based experimental and theoretical research efforts and concurrent flight experimentation. This talk will focus on the ground-based studies on the PVT crystal growth of ZnSe and related ternary compounds. The objectives of the ground-based studies are (1) obtain the experimental data and conduct the analyses required to define the optimum growth parameters for the flight experiments, (2) perfect various characterization techniques to establish the standard procedure for material characterization, (3) quantitatively establish the characteristics of the crystals grown on Earth as a basis for subsequent comparative evaluations of the crystals grown in a low-gravity environment and (4) develop theoretical and analytical methods required for such evaluations. ZnSe and related ternary compounds have been grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals have been characterized extensively by various techniques to correlate the grown crystal properties with the growth conditions.

Su, Ching-Hua↗

Flight Experiments of Physical Vapor Transport of ZnSe: Growth of Crystals in Various Convective Conditions

A low gravity material experiment will be performed in the Material Science Research Rack (MSRR) on International Space Station (ISS). The flight experiment will conduct crystal growths of ZnSe and related ternary compounds, such as ZnSeS and ZnSeTe, by physical vapor transport (PVT). The main objective of the project is to determine the relative contributions of gravity-driven fluid flows to the compositional distribution, incorporation of impurities and defects, and deviation from stoichiometry observed in the grown crystals as results of buoyancy-driven convection and growth interface fluctuations caused by irregular fluid-flows on Earth. The investigation consists of extensive ground-based experimental and theoretical research efforts and concurrent flight experimentation. The objectives of the ground-based studies are (1) obtain the experimental data and conduct the analyses required to define the optimum growth parameters for the flight experiments, (2) perfect various characterization techniques to establish the standard procedure for material characterization, (3) quantitatively establish the characteristics of the crystals grown on Earth as a basis for subsequent comparative evaluations of the crystals grown in a low-gravity environment and (4) develop theoretical and analytical methods required for such evaluations. ZnSe and related ternary compounds have been grown by vapor transport technique with real time in-situ non-invasive monitoring techniques. The grown crystals have been characterized extensively by various techniques to correlate the grown crystal properties with the growth conditions. This talk will focus on the ground-based studies on the PVT crystal growth of ZnSe and related ternary compounds, especially the effects of different growth orientations related to gravity direction on the grown crystals.

Su, Ching-Hua↗

Vibro-acoustic Testing for Microstructure Characterization and Metrology: Technology Commercialization Fund—Fiscal Year 2017

There is a need in nuclear reactors to inspect irradiated materials and structures. A portable scanning infrastructure for a material characterization technique called vibro acoustography (VA) is being developed by the Idaho National laboratory for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA technique has several advantages over traditional characterization techniques. VA is a non-contact submersion technique that is inherently wireless transmission and reception (from the ultrasonic transmitter to the acoustic receiver). The transmission medium can be most liquids used for reactor cooling such as water and sodium. For nuclear in-pile applications, the Ultrasonic Transducer (UT) will need to have a line of sight location that is within lower radiation flux zones. Multiple UT sources can be frequency multiplexed to allow a single hydrophone receiver to monitor several locations. The reactor structure can also be an integral part of the transmission system acting as waveguides to deliver the acoustic signal to an acoustic receiver. Because of the long wavelength of the acoustic signal, the acoustic receiver does not have to be line of sight with respect to the component under test. The focusing and generation of the acoustic beat frequency from two ultrasonic waves allows for the potential to ultrasonically image complex shapes. These features will significantly reduce experiment complexity, installation times and cost while being safe and easy to use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interface Characterization within a Nuclear Fuel Plate

To predict the performance of nuclear fuels and materials, irradiated fuel plates must be characterized efficiently and accurately in highly radioactive environments. The characterization must take place remotely and work in settings largely inhospitable to modern digital instrumentation. Characterization techniques based on non-contacting laser sensing methods enable remote operation in a robust manner within a hot-cell environment. Laser characterization instrumentation can offer high spatial resolution and remain effective for scanning large areas. A laser shock (LS) system is currently being developed as a post-irradiation examination (PIE) technique in the hot fuel examination facility (HFEF) at the Idaho National Laboratory (INL). The laser shock technique will characterize material properties and failure loads/mechanisms in various composite components and materials such as plate fuel and next-generation fuel forms in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel–clad bond. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the application of the laser shock. The laser shock system has been used to characterize the resulting bond strength within plate fuels which have been fabricated using different fabrication processes. The results of this study will be to select the fabrication process that provides the strongest interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Progress In Developing Laser Based Post Irradiation Examination Infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in a high rad environment. The characterization work must be performed remotely and in an environment hostile to instrumentation. Laser based characterization techniques provide the ability to be remote and robust in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: Laser Shock Laser based ultrasonic C-scan system Gas Assay, Sample, and Recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as LWR fuel, plate fuel, and next generation fuel forms, for PIE in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. The shock wave travels as a compression wave through the material to the free (unconfined) back surface and reflects back through the material under test as a rarefaction (tensile) wave. This rarefaction wave is the physical mechanism that produces internal de-lamination failure. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the laser shock technique. The laser ultrasonic system will be fully capable of performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology in complex components. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element and the analysis of fission gases released from the fuel is important to understanding the performance of reactor fuels and materials. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The main function of the laser in this application is to puncture the fuel element to allow the fission gas to escape and if necessary to weld the spot close. The GASR station will have the inherent capability to perform cutting welding and joining functions within a hot-cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress in developing laser based post irradiation examination infrastructure

To be able to understand the performance of reactor fuels and materials, irradiated materials must be characterized effectively and efficiently in high rad environments. This characterization work is performed remotely and in environments generally hostile to instrumentation. Laser based characterization techniques provide the ability to operate remotely and robustly in a hot-cell environment. Laser based instrumentation also can provide high spatial resolution suitable for scanning and imaging large areas. The INL is currently developing three laser based Post Irradiation Examination (PIE) stations for the Hot Fuel Examination Facility (HFEF) at the INL. These laser based systems will characterize irradiated materials and fuels. The characterization systems are the following: -) laser shock, -) laser based ultrasonic C-scan system and -) gas assay, sample and recharge system (GASR, up-grade to an existing system). The laser shock technique will characterize material properties and failure loads/mechanisms in various materials such as Light Water Reactor (LWR) fuel, plate fuel, and next generation fuel forms in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel-clad bond. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize de bonding caused by the application of the laser shock as well as performing classical non-destructive evaluation testing and imaging functions such as microstructure characterization, flaw detection and dimensional metrology. A spectroscopy capability can be added later as the salient components to perform Light Induced Breakdown Spectroscopy will be in place. Additional fiber ports in the feed-through will also enable future spectroscopic techniques to be efficiently installed and operated. The purpose of the GASR is to measure the pressure/volume of the plenum of an irradiated fuel element/capsule and obtain fission gas samples for analysis. The study of pressure and volume in the plenum of an irradiated fuel element/capsule and the analysis of fission gases released is important to understanding the performance of reactor fuels and materials. The main function of the laser in this application is to puncture the fuel rod or plate to allow the fission gas to escape and if necessary to weld the hole close. This system may also be used to measure the pressure/volume of other components (such as control blades) and obtain gas samples from these components for analysis. The GASR upgrade will match the functionality of the current system and provide these important functions on fuels made from current and future engineered materials. The GASR station will also have the inherent capability to perform cutting welding and joining functions within a hot-cell. The extra fiber ports built into the hot cell feed-through will also enable the efficient installation of future laser processing work benches. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Initial Assessment of X-Ray Computer Tomography image analysis for material defect microstructure

The original development work leading to this report was focused on the non destructive three-dimensional (3-D) characterization of nuclear graphite as a means to better understand the nature of the inherent pore structure. The pore structure of graphite and its evolution under various environmental factors such as irradiation, mechanical stress, and oxidation plays an important role in their observed properties and characteristics. If we are to transition from an empirical understanding of graphite behavior to a truly predictive mechanistic understanding the pore structure must be well characterized and understood. As the pore structure within nuclear graphite is highly interconnected and truly 3-D in nature, 3-D characterization techniques are critical. While 3-D characterization has been an excellent tool for graphite pore characterization, it is applicable to a broad number of materials systems over many length scales. Given the wide range of applications and the highly quantitative nature of the tool, it is quite surprising to discover how few materials researchers understand and how valuable of a tool 3-D image processing and analysis can be. Ultimately, this report is intended to encourage broader use of 3 D image processing and analysis in materials science and engineering applications, more specifically nuclear-related materials applications, by providing interested readers with enough familiarity to explore its vast potential in identifying microstructure changes. To encourage this broader use, the report is divided into two main sections. Section 2 provides an overview of some of the key principals and concepts needed to extract a wide variety of quantitative metrics from a 3-D representation of a material microstructure. The discussion includes a brief overview of segmentation methods, connective components, morphological operations, distance transforms, and skeletonization. Section 3 focuses on the application of concepts from Section 2 to relevant materials at Idaho National Laboratory. In this section, image analysis examples featuring nuclear graphite will be discussed in detail. Additionally, example analyses from Transient Reactor Test Facility low-enriched uranium conversion, Advanced Gas Reactor like compacts, and tristructural isotopic particles are shown to give a broader perspective of the applicability to relevant materials of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron backscatter diffraction of Nb 3 Sn coated niobium: Revealing structure as a function of depth

Over the last two decades, advances in Electron Backscatter Diffraction (EBSD) have moved the technique from a research tool to an essential characterization technique in many fields of material research. EBSD is the best suited technique for determining structure as a function of depth. This characterization is critically important, but has been previously absent from Nb 3 Sn efforts. While EBSD is the technique of choice, obtaining quality data can be difficult. Sample preparation in particular is non-trivial. Here we summarize the general principles of EBSD, discuss specific sample preparation techniques for Nb 3 Sn coated SRF cavity material, and give examples of how EBSD is being used to understand fundamental growth mechanisms for Nb 3 Sn coatings.

36 MATERIALS SCIENCE↗

Comparing non-destructive 3D X-ray computed tomography with destructive optical microscopy for microstructural characterization of fiber reinforced composites

Due to their lightweight, relatively high stiffness properties, and formability into complex shapes, discontinuous fiber composites are advantageous for producing small and medium size components. Improved characterization techniques and post-processing methodologies are required for more reliable quantification of the microstructure and defect distributions in these materials, in order to employ model-based approaches to assess their structural integrity. This work compares a non-destructive X-ray approach with a destructive optical microscopy approach for characterizing the microstructural attributes, specifically the fiber volume fraction, porosity volume fraction, fiber orientation distribution, and fiber length distribution of discontinuous glass fibers in a polypropylene matrix. Additionally, a method for destructively determining the ambiguous components of the orientation tensor (related to the sign ambiguity of the out-of-plane angle in a destructive cross-sectional cut of a fiber) over a large surface area is included. It was found that fiber volume fraction and average fiber aspect ratio matched well, while fiber orientation and porosity detection had small but notable differences. The differences in the detection capabilities of each technique are quantified and discussed shedding light on the specific advantages and disadvantages of each approach, and enabling engineers to quantify uncertainty in their microstructural characterization measurements especially as they relate to model based structural integrity activities.

Non-destructive testing↗

In-situ X-ray Nanocharacterization of Defect Kinetics in Chalcogenide Solar Cell Materials

For decades the optimization of polycrystalline absorbers has been done using an Edisonian approach, where trial and error and complex design of experiments in large parameter spaces have driven efficiencies to the record values we see today – CIGS at 22.5%, 22.1% for CdTe, 21.3% for high purity multi-crystalline silicon. Appropriate growth parameters are critical to ensure good quality crystals with low concentration of structural defects - low dislocation density and large grain sizes. However, to bridge the gap between the efficiencies today and the fundamental Shockley-Queisser limit for these materials a much more fundamental understanding of the role and interaction between composition, structure, defect density and electrical properties is required. In recent years multiple novel characterization techniques have shown the potential that nanoscale characterization can have in deciphering the composition of grain boundaries in materials like CIGS and CdTe. However, high resolution has come at the cost of small sampling areas and number of specimens, making it extremely difficult to draw conclusions based on the characteristic small sampling sizes. The missing links thus far have been: (1) the lack of statistical meaningfulness of the nanosclae studies and (2) the direct correlation of compositional variations to electrical performance with nanoscale resolution. In this work we present the use of synchrotron-based nano-X-ray fluorescence microscopy (nano-XRF), x-ray absorption nanospectroscopy (nano-XAS) coupled with nano-x-ray beam induced current (nano-XBIC) as ideal tools for investigating elemental, chemical and electrical properties of large areas of solar cell materials at the sub-micron scale with very high sensitivity. We show how the technique can provide statistical valuable information regarding the elemental segregation in CIGS and the direct correlation to current collection. For example, we demonstrate that Cu and Ga (and with that, CGI and GGI) correlate positively, and In negatively with charge collection efficiency for cells with low Ga content, both at grain boundaries and in grain cores. For cells with high Ga content, the charge collection efficiency depends to much lesser extent on the elemental distribution. The objective is three folded: (1) develop an x-ray in-situ microscopy capability to simulate growth and processing conditions, (2) apply it to elucidate performance-governing defect kinetics in chalcogenide solar cell materials, and (3) to study approaches to engineer materials from the nanoscale up. The development of these capabilities will enable experimental characterization to take place under actual processing and operating conditions and it will have impact well beyond the proposed research, enabling future studies on a large variety of materials system where electronic properties depend on underlying structural or chemical inhomogeneities.

14 SOLAR ENERGY↗

Structure, nanomechanics, and dynamics of dispersed surfactant‐free clay nanocomposite films

The current work presents a new approach to achieve high quality dispersion of surfactant‐free nanoclay tactoid particles in sub‐micron thin films despite the absence of organic modifier. Natural Montmorillonite particles, Cloisite, were dispersed in thin films of polycaprolactone (PCL) through a flow coating technique assisted by ultra‐sonication. Wide‐angle X‐ray scattering (WAXS), grazing‐incidence wide‐angle X‐ray scattering (GI‐WAXS), and transmission electron microscopy (TEM) were used to confirm the level of natural clay dispersion down to the level of tactoids (sub‐micron scale stacks of clay sheets). These characterization techniques were carried out in conjunction with an analysis of nanomechanical properties via strain‐induced buckling instability for modulus measurements (SIEBIMM), a high‐throughput technique to characterize thin film mechanical properties. The buckling patterns indicate that the natural clay tactoids separate buckling‐enhancing (high‐modulus) crystalline regions and interconnect buckling‐suppressing amorphous (low‐modulus) regions. Due to the tactoid length scale, the glass transition behavior of the composites as characterized by broadband dielectric relaxation spectroscopy was unmodified by the clay. Likewise, the glass transition temperature, T g , and fragility (slope of relaxation time behavior approaching T g ), remain unaffected, indicating that these dispersed tactoids do not induce pronounced confinement effects on dynamics. POLYM. ENG. SCI., 58:1285–1295, 2018. © 2018 Society of Plastics Engineers

Zhang, Xiao↗

Standardization Gaps in Powder Feedstock Characterization and Establishing Acceptability for Reuse in Additive Manufacturing

Characterization techniques for powder feedstocks used in additive manufacturing (AM) have long been relied upon to describe the inputs to an AM workflow. However, functional gaps remain between tests to measure intrinsic and extrinsic properties with the direct performance within AM equipment. Furthermore, the common practice of reusing powder through multiple build cycles introduces effects and changes to feedstock performance that are otherwise difficult to measure quantitatively. Here, standardization and the development of new test methods have not kept pace with the rapid evolution of the AM industry and its reliance on highly coupled process-structure–property-performance relationships.

Characterization and Analytical Technique↗

Synchrotron‐Based X‐ray Absorption Fine Structures, X‐ray Diffraction, and X‐ray Microscopy Techniques Applied in the Study of Lithium Secondary Batteries

Abstract Owing to the recent advance of third‐generation synchrotron radiation (SR) sources, SR‐based X‐ray techniques have been widely applied to study lithium‐ion batteries, lithium–sulfur batteries, and lithium–oxygen batteries to solve material challenges. SR‐based techniques provide high chemical and physical sensitivity and a comprehensive picture of material structure and reaction mechanisms. An in‐depth understanding of batteries is imperative for the development of future energy storage devices with enhanced electrochemical performance to meet societies' growing need for devices with high energy density. Here, recent progress in the application of SR techniques for lithium secondary batteries with a focus on several techniques, including X‐ray absorption fine structure, synchrotron X‐ray diffraction, and synchrotron X‐ray microscopy techniques is reviewed. The working principle for all characterization techniques is introduced to provide context for how the technique is used in the field of energy storage. Through discussing the utilization of SR techniques in different directions of batteries, including electrodes, electrolytes, and interfaces, the practical application strategies of techniques in batteries are clarified. By summarizing and discussing the application of SR techniques in batteries, the aim is to highlight the crucial role of SR characterization in the development of advanced energy materials.

Li, Weihan↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence of Room Temperature Ferromagnetism in Zn{sub 1−x}Sn{sub x}S Thin Films

Tin (Sn)-doped zinc sulfide (Zn{sub 1−x}Sn{sub x}S) thin films at different tin (Sn) concentrations (= 0.00, 0.02, 0.05, and 0.08) were coated onto Corning 7059 glass substrates using the electron beam evaporation technique. The films were subjected to different characterization techniques to study the physical properties of the thin films. The structural properties of the films were studied using a powder X-ray diffractometer (XRD), and it was found that the films were cubic in structure without any impurity phases. The crystallite size increased with an increase of Sn concentration, and the mean crystallite size was 21 nm. The chemical composition and surface morphology of the films were studied using scanning electron microscopy (FE-SEM) with energy-dispersive analysis of X-rays (EDAX). Optical properties such as transmittance and absorbance were recorded using a diffuse reflectance spectroscope (UV–vis–NIR). All the films exhibited high optical transmittance of 85% in the visible region of the solar spectrum. The band gap of the films was calculated using Tauc’s relation, and it was found that it increased from 3.53 to 3.57 eV with an increase in the Sn doping concentration from x = 0.02 to x = 0.08. The room temperature photoluminescence studies of the films were recorded using a fluorescence spectrophotometer, and it was found that the films exhibited a prominent emission peak at 420 nm. The magnetic properties of the films and glass substrates at room temperature were studied using a vibrating sample magnetometer. From this, it was found that the films were weakly ferromagnetic at room temperature and the strength of magnetization increased with an increase of doping concentration from x = 0.02 to x = 0.05 and decreased at higher doping concentrations (x = 0.08). The films showed high magnetization at x = 0.05. The films at x = 0.05 exhibited the magnetization (M{sub s}), retentivity (M{sub r}), and coercive fields (H{sub c}) 18 × 10{sup − 6} emu/cm{sup 3}, 1.6 × 10{sup − 6} emu/cm{sup 3}, and 91.80 Oe, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Importance of multimodal characterization and influence of residual Li 2 S impurity in amorphous Li 3 PS 4 inorganic electrolytes

Amorphous Li 3 PS 4 (LPS) solid-state electrolytes are promising for energy-dense lithium metal batteries. LPS glass, synthesized from a 3:1 mol ratio of Li 2 S and P 2 S 5 , has high ionic conductivity and can be synthesized by ball milling or solution processing. Ball milling has been attractive because it provides the easiest route to access amorphous LPS with a conductivity of 3.5 × 10 –4 S cm –1 (20 °C). However, achieving the complete reaction of precursors via ball milling can be difficult, and most literature reports use X-ray diffraction (XRD) or Raman spectroscopy to confirm sample purity, both of which have limitations. Furthermore, the effect of residual precursors on ionic conductivity and lithium metal cycling is unknown. In this work, we illustrate the importance of multimodal characterization to determine LPS phase and chemical purity. To determine the residual Li 2 S content in LPS, we show that (1) XRD and 31 P solid state nuclear magnetic resonance (ssNMR) are insufficient and (2) Raman loses sensitivity at concentrations below 12 mol% Li 2 S. Most importantly, we show that 7 Li ssNMR is highly sensitive. Using 7 Li ssNMR, we investigate the effect of ball milling parameters and develop a robust and highly reproducible procedure for pure LPS synthesis. We find that as the residual Li 2 S precursor content increases, LPS conductivity decreases and lithium metal batteries exhibit higher overpotentials and poor cycle life. Furthermore, our work reveals the importance of multimodal characterization techniques for amorphous solid-state electrolyte characterization and will enable better synthetic strategies for highly conductive electrolytes for efficient energy-dense solid-state lithium metal batteries.

25 ENERGY STORAGE↗

Measuring radiation damage dynamics by pulsed ion beam irradiation: 2016 project annual report

The major goal of this project is to develop and demonstrate a novel experimental approach to access the dynamic regime of radiation damage formation in nuclear materials. In particular, the project exploits a pulsed-ion-beam method in order to gain insight into defect interaction dynamics by measuring effective defect interaction time constants and defect diffusion lengths. For Year 3, this project had the following two major milestones: (i) the demonstration of the measurement of thermally activated defect-interaction processes by pulsed ion beam techniques and (ii) the demonstration of alternative characterization techniques to study defect dynamics. As we describe below, both of these milestones have been met.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final project report for NEET pulsed ion beam project

The major goal of this project was to develop and demonstrate a novel experimental approach to access the dynamic regime of radiation damage formation in nuclear materials. In particular, the project exploited a pulsed-ion-beam method in order to gain insight into defect interaction dynamics by measuring effective defect interaction time constants and defect diffusion lengths. This project had the following four major objectives: (i) the demonstration of the pulsed ion beam method for a prototypical nuclear ceramic material, SiC; (ii) the evaluation of the robustness of the pulsed beam method from studies of defect generation rate effects; (iii) the measurement of the temperature dependence of defect dynamics and thermally activated defect-interaction processes by pulsed ion beam techniques; and (iv) the demonstration of alternative characterization techniques to study defect dynamics. As we describe below, all these objectives have been met.

36 MATERIALS SCIENCE↗