Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold temperatures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Impact of heating and cooling loads on battery energy storage system sizing in extreme cold climates

Efficient operation of battery energy storage systems requires that battery temperature remains within a specific range. Current techno-economic models neglect the parasitic loads heating and cooling operations have on these devices, assuming they operate at constant temperature. In this work, these effects are investigated considering the optimal sizing of battery energy storage systems when deployed in cold environments. Here, a peak shaving application is presented as a linear programming problem which is then formulated in the PYOMO optimization programming language. The building energy simulation software EnergyPlus is used to model the heating, ventilation, and air conditioning load of the battery energy storage system enclosure. Case studies are conducted for eight locations in the United States considering a nickel manganese cobalt oxide lithium ion battery type and whether the power conversion system is inside or outside the enclosure. The results show an increase of 42% to 300% in energy capacity size, 43% to 217% in power rating, and 43% to 296% increase in capital cost dependent on location. This analysis shows that the heating, ventilation, and air conditioning load can have a large impact on the optimal sizes and cost of a battery energy storage system and merit consideration in techno-economic studies.

25 ENERGY STORAGE↗

Environment-sensitivity functions for gross primary productivity in light use efficiency models

The sensitivity of photosynthesis to environmental changes is essential for understanding carbon cycle responses to global climate change and for the development of modeling approaches that explains its spatial and temporal variability. We collected a large variety of published sensitivity functions of gross primary productivity (GPP) to different forcing variables to assess the response of GPP to environmental factors. These include the responses of GPP to temperature; vapor pressure deficit, some of which include the response to atmospheric CO 2 concentrations; soil water availability (W); light intensity; and cloudiness. These functions were combined in a full factorial light use efficiency (LUE) model structure, leading to a collection of 5600 distinct LUE models. Each model was optimized against daily GPP and evapotranspiration fluxes from 196 FLUXNET sites and ranked across sites based on a bootstrap approach. The GPP sensitivity to each environmental factor, including CO 2 fertilization, was shown to be significant, and that none of the previously published model structures performed as well as the best model selected. From daily and weekly to monthly scales, the best model's median Nash-Sutcliffe model efficiency across sites was 0.73, 0.79 and 0.82, respectively, but poorer at annual scales (0.23), emphasizing the common limitation of current models in describing the interannual variability of GPP. Although the best global model did not match the local best model at each site, the selection was robust across ecosystem types. The contribution of light saturation and cloudiness to GPP was observed across all biomes (from 23% to 43%). Temperature and W dominates GPP and LUE but responses of GPP to temperature and W are lagged in cold and arid ecosystems, respectively. The findings of this study provide a foundation towards more robust LUE-based estimates of global GPP and may provide a benchmark for other empirical GPP products.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen-rich syngas production from the steam co-gasification of low-density polyethylene and coal refuse

Gasification provides a promising pathway for transforming waste materials into valuable products, such as fuels and chemicals. Here, this study investigates the steam co-gasification of low-density polyethylene (LDPE) and compressed thickener underflow, representative of coal refuse (CR), in a drop tube reactor. The effects of feed blend ratio (0–100 wt% LDPE) and temperature (800–1000 °C) on syngas composition, tar formation, and process efficiency are examined. The high volatility of LDPE makes it more reactive than CR but also promotes the formation of 2–7 ring aromatic tars. Increasing temperature improves carbon conversion efficiency (CCE), cold gas efficiency (CGE), and syngas yield, although the lower heating value (LHV) of syngas decreases. Hydrogen is the dominant gas product, reaching 59 vol% with the H 2 /CO molar ratio ranging from 2.27 to 4.74. Synergistic effects from alkali and alkali earth metals (AAEMs), particularly K and Ca, in CR ash enhance syngas yield by catalyzing char gasification and tar cracking. Hematite (Fe 2 O 3 ) and ash from sub-bituminous/bituminous coals are explored as tar reforming catalysts. Fe 2 O 3 achieves 100 % tar reforming efficiency, while coal ash, with a lower Fe 2 O 3 content (15 wt%), is less effective at cracking polycyclic aromatic hydrocarbons, particularly naphthalene. These findings demonstrate the flexibility of co-gasification, allowing precise tuning of syngas characteristics for specific downstream applications. Further optimization of waste-derived catalysts could enhance the economic viability of gasification in waste-to-energy processes.

01 COAL, LIGNITE, AND PEAT↗

Numerical predictions of cryogenic hydrogen vertical jets

Here, a comparison of Computational Fluid Dynamics (CFD) predictions with measurements is presented for cryo-compressed hydrogen vertical jets. The stagnation conditions of the experiments are characteristic of unintended leaks from pipe systems that connect cryogenic hydrogen storage tanks and could be encountered at a fuel cell refueling station. Jets with pressure up to 5 bar and temperatures just above the saturation liquid temperature were examined. Comparisons are made to the centerline mass fraction and temperature decay rates, the radial profiles of mass fraction and the contours of volume fraction. Two notional nozzle approaches are tested to model the under-expanded jet that was formed in the tests with pressures above 2 bar. In both approaches the mass and momentum balance from the throat to the notional nozzle are solved, while the temperature at the notional nozzle was assumed equal to the nozzle temperature in the first approach and was calculated by an energy balance in the second approach. The two approaches gave identical results. Satisfactory agreement with the measurements was found in terms of centerline mass fraction and temperature. However, for test with 3 and 4 bar release the concentration was overpredicted. Furthermore, a wider radial spread was observed in the predictions possibly revealing higher degree of diffusion using the k-ε turbulence model. An integral model for cryogenic jets was also developed and provided good results. Finally, a test simulation was performed with an ambient temperature jet and compared to the cold jet showing that warm jets decay faster than cold jets.

08 HYDROGEN↗

Tailoring grain growth and solid solution strengthening of single-phase CrCoNi medium-entropy alloys by solute selection

In the present study, we selected solutes to be added to the CrCoNi medium-entropy alloy (MEA) based on the mismatch of self-diffusion activation energy (SDQ) between the alloying elements and constituent elements of the matrix, and then investigated their grain growth behavior and mechanical properties. Mo and Al were selected as the solutes for investigation primarily because they have higher and lower SDQ, respectively, than those of the matrix elements; a secondary factor was their higher and lower shear modulus. Their concentrations were fixed at 3 at.% each because previous work had shown these compositions to be single-phase solid solutions with the face-centered cubic structure. Three alloys were produced by arc melting, casting, homogenizing, cold rolling and annealing at various temperatures and times to produce samples with different grain sizes. They were (a) the base alloy CrCoNi, (b) the base alloy plus 3 at.% Mo, and (c) the base alloy plus 3 at.% Al. The activation energies for grain growth of the CrCoNi, CrCoNi-3Mo and CrCoNi-3Al MEAs were found to be ~251, ~368 and ~219 kJ/mol, respectively, consistent with the notion that elements with higher SDQ (in this study Mo) retard grain growth (likely by a solute-drag effect), whereas those with lower values (Al) accelerate grain growth. The room-temperature tensile properties show that Mo increases the yield strength by ~40% but Al addition has a smaller strengthening effect consistent with their relative shear moduli. The yield strength as a function of grain size for the three singlephase MEAs follows the classical Hall-Petch relationship with much higher slopes (> 600 MPa μm -0.5 ) than traditional solid solutions. Furthermore, this work shows that the grain growth kinetics and solid solution strengthening of the CrCoNi MEA can be tuned by selecting solute elements that have appropriate diffusion and physical properties.

36 MATERIALS SCIENCE↗

Scalable, low-cost ink-based processing of high-performance silver selenide thermoelectrics

The growing global energy demand and its accelerating contribution to climate change emphasize the urgent need for sustainable energy conversion/harvesting technologies. Thermoelectric (TE) devices offer a compelling route to directly convert waste heat into electricity and enable solid-state cooling without moving parts or harmful refrigerants. Achieving their full potential requires not only higher TE performance (zT) but also scalable, low-cost manufacturing processes. Here, we introduce a transformative ink-based processing approach for scalable manufacturing of high-performance silver selenide-based TE materials and devices. Using a simple, high-throughput ink-mixing and blade coating strategy, our Ag 2 Se-based materials under the optimized composition and processing conditions yield an ultrahigh room-temperature power factor of 2.8 mW m −1 K −2 , over 100% higher than baseline samples and a reproducible figure of merit zT of 1 at room temperature. A thermoelectric generator (TEG) achieves a very competitive power density of 112 mW cm −2 at a 90 °C temperature difference between the hot and cold sides of the device, which is among the highest reported for silver selenide-based TE devices to date. This facile, scalable ink-based processing establishes a practical pathway toward industrial-scale manufacturing and widespread adoption of thermoelectric devices, advancing sustainable energy technologies.

Bappy, Md. Omarsany [University of Notre Dame, IN ↗

Nonlinear evolution, propagation, electron-trapping, and damping effects of ion-acoustic solitons using fully kinetic PIC simulations

We investigate ion acoustic solitary waves (solitons) of varying amplitudes in a one-dimensional plasma using fully kinetic particle-in-cell simulations. The initial soliton conditions are based on the Korteweg–de Vries (KdV) equation, treating ions as a cold species and electrons with finite temperature. Our findings reveal that KdV solitons evolve nonlinearly to a saturated state at higher amplitude, deviating from KdV predictions for ion density and electric potential, and from the Boltzmann relation for electron density. At this saturated state, the KdV model cannot accurately describe the soliton behavior. For small amplitudes, Sagdeev's model describes the saturated state, but not the soliton width; for larger amplitudes, it models the width accurately, but not the amplitude. These discrepancies arise from assuming a Boltzmann relation for electron density, while electron trapping creates non-Boltzmann densities—a deviation that increases with soliton amplitude. Additionally, we observe that the soliton amplitude oscillates roughly at the electron bounce frequency. The soliton is better described by Schamel's electron density formulation and a modified KdV equation incorporating electron trapping. The soliton velocity matches best with predictions from Sagdeev's and Schamel's models. Moreover, the soliton speed–amplitude relationship differs from existing theoretical predictions. Finally, we find minimal ion and electron Landau damping effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational experience with the Proto-DUNE NP02 and NP04 large volume liquid argon cryostats and their cryogenic systems at CERN

The far Detector of the Deep Underground Neutrino Experiment (DUNE) will be housed in several large volume (about 12.500 m$^{3}$) liquid argon cryostats. The design principle of these large cryostats, and of the cryogenic system belonging to them, are investigated through the design, construction and operation of a series of prototype installations.The Neutrino Platform 02 (NP02) and 04 (NP04) cryostats, placed at CERN, contain DUNE proto-type detectors, each of them housed in an about 600 m$^{3}$ liquid argon bath. These cryostats, based on the membrane cryostat principle, and their cryogenic systems have been designed according to the DUNE principle. Measurements performed in these test stands shall confirm the foreseen heat loads into the cryostat systems entering via its walls, via detector cabling and via the cold electronics, shall confirm the low temperature gradient over the active detector volume and shall certify the liquid argon purification principle.This paper introduces the requirements for the NP02 and NP04 cryostats and their cryogenic systems, describes the design principle applied to these two systems and gives an overview of the different modes in which the two systems have been operating. The experimental results are presented and discussed, and “lessons learned” for future installations are dawn.

43 PARTICLE ACCELERATORS↗

Thermo-rheological snapshot of melter feed conversion to glass

Slurry feed charged into an electric melter creates a layer of reacting and melting material (termed cold cap) that floats on the surface of molten glass. The rheological behavior of heated melter feed affects the spreading of slurry at the top of the cold cap and the stability of the primary foam, affecting cold-cap coverage and melter plenum temperatures. The apparent viscosity of a high-alumina high-level waste melter feed was assessed by thermomechanical analysis, high-temperature viscometer, and the hot stage microscopy method, yielding viscosity estimates from ≈10 7.5 Pa s at 550°C to ≈10 2.5 Pa s at 1050°C. As the temperature of feed materials increased, their state changed from rigid solid to dilatant fluid, to pseudoplastic bubbly liquid with dissolving solids, to fully developed foam, and finally to Newtonian glass melt.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

Editorial: Using high energy density plasmas for nuclear experiments relevant to nuclear astrophysics

Thermonuclear reaction rates and nuclear processes have traditionally been explored by means of accelerator experiments, which are difficult to execute at conditions relevant to nucleosynthesis. High energy density (HED) plasmas generated using lasers, such as the inertial confinement fusion (ICF) platform, more closely mimic astrophysical environments in several ways, including with thermal distributions of reacting ions as opposed to mono-energetic ions impinging on a cold target; stellar-relevant plasma temperatures and densities; and neutron flux densities not found anywhere else on earth. The most extreme conditions can currently be achieved at the National Ignition Facility (NIF) laser in the US, where densities of 10 3 g/cm 3 and neutron fluxes up to 5∙10 27 neutrons/cm/s have been demonstrated over a time period of a few tens of picoseconds. The HED platform is emerging as an interesting complement to accelerator experiments.

charged-particle-induced reactions↗

Accelerated Aging of Fast Pyrolysis Bio-Oils

Carbonyl content is a better metric for tracking aging than viscosity. Existing aging test (24 hours @ 80 °C) is too severe, and correlates to more room temperature aging than would realistically occur. New aging test proposed: 2 hours @ 80 °C correlates to 1-3 months of room temperature storage. Aging is slowed in cold storage, but still occurs.

aging↗

Resilience Assessment Framework For Electric Distribution Systems Performance Under Extreme Conditions

The devastating impact of extreme weather-related events is increasingly evident on power grids, especially on distribution grids. The severity of their potential impact calls for 1) developing a suitable resilience assessment framework to capture the system performance and 2) assessing relevant mitigative strategies to lessen the impact of such events. This paper proposes a framework to identify grid vulnerabilities using the energy-at-risk concept to select, disconnect and isolate grid portions due to a resilience event. The proposed framework mainly consists of two steps; i) processing the utility's available infrastructure, i.e., a network model, possible switching combinations, and outage information for those combinations, as a graph-based database, and ii) implementing a novel optimal switching algorithm leveraging database and grid simulated metrics. These switching actions are generated to implement load curtailment in a rolling manner during anticipated grid scarcity conditions. In this study, a test case is created using two taxonomy feeders and is simulated against an extreme temperature event, e.g., a long, relatively cold, and prolonged freeze peak, thereby creating stress on the grid. It is demonstrated that the proposed framework allows utilities to predict the energy-at-risk during such resilience events and design suitable outage management strategies.

Poudel, Shiva↗

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Elastic Anisotropy of Lizardite at Subduction Zone Conditions

Subduction zones transport water into Earth's deep interior through slab subduction. Serpentine minerals, the primary hydration product of ultramafic peridotite, are abundant in most subduction zones. Characterization of their high-temperature elasticity, particularly their anisotropy, will help us better estimate the extent of mantle serpentinization and the Earth's deep water cycle. Lizardite, the low-temperature polymorph of serpentine, is stable under the P-T conditions of cold subduction slabs (<260°C at 2 GPa), and its high-temperature elasticity remains unknown. Here we report ab initio elasticity and acoustic wave velocities of lizardite at P-T conditions of subduction zones. Our static results agree with previous studies. Its high-temperature velocities are much higher than previous experimental-based lizardite estimates with chrysotile but closer to antigorite velocities. The elastic anisotropy of lizardite is much larger than that of antigorite and could better account for the observed large shear-wave splitting in some cold slabs such as Tonga.

58 GEOSCIENCES↗

A Framework for Characterizing the Initial Thermal Conditions of Light-Duty Vehicles in Response to Representative Utilization Patterns, Ambient Conditions, and Vehicle Technologies

It is widely understood that the thermal state of a light-duty vehicle at the beginning of a trip influences the vehicle performance throughout the drive cycle. Cold starts, or initial states with component temperatures near ambient conditions, are strongly correlated with reduced vehicle performance and energy efficiency and with increased emissions. Despite this understanding, there is little literature available that characterizes initial thermal states beyond empirical studies and simplified analyses of dwell times. We introduce a framework that considers vehicle activity patterns, including the previous drive event, duration of the previous dwell event, and relevant ambient conditions occurring during these events. Moreover, the framework allows for technologies to influence the prominence of cold starts and warm starts. An example application of the methodology using a powertrain model approach revealed the significance of all constituent factors: controlling for ambient conditions, the shortest dwell lengths corresponded to an average initial oil temperature of 70°C versus 23°C for the long dwell length simulations, and aggressive conditioning cycles corresponded to an average initial oil temperature of 51°C versus only 35°C for a short conditioning cycle. The coldest ambient conditions evaluated (-30°C to -10°C) produced a weighted initial oil temperature of 19°C versus 57°C for the warmest ambient conditions evaluated (30°C to 50°C). Finally, we introduce weighting factors that account for the real-world frequency of conditioning cycle and dwell length combinations. The procedure outlined may be useful for discovering real-world performance improvements associated with vehicle technologies, a topic of interest to both vehicle manufacturers and regulators.

33 ADVANCED PROPULSION SYSTEMS↗

Compositional Variation Tests on DuraMelter 100 with LAW Sub-Envelope A1 Feed (LAWA44 Glass) in Support of the LAW Pilot Melter, VSL-02R62N0-4, Rev. 0 (Nov 2002)

The two tests described in this report utilized blended feed (glass formers plus waste simulant) prepared by Optima Chemicals according to VSL specifications generating about 1. 7 metric tons of glass. Sugar was added (at VSL) to the nominal feed at a "sugar ratio" of 0.5 for each of the two variation tests1; however, since the sugar addition is assumed to be "blind" to the variations, the actual sugar ratios were 0.57 and 0.44. The DMl00-WV melter was used in order to provide a direct comparison with the LAW tests previously conducted on the same melter. Two 100-hour melter tests were conducted: one with a 15% deficiency in simulant and one with 15% excess in simulant. Key operating parameters including cold cap coverage, feed rate, and glass pool temperature were held constant to investigate the effects of the glass compositional changes on processing characteristics (including salt formation) and the product glass. The bubbling rate was adjusted to provide the desired glass production rate with a near complete cold cap (90-100% of melt surface covered with feed). Quantitative measurements of glass production rates, melter operating conditions (temperatures, pressures, power, flows, etc.), and off-gas characteristics (NOx, SO 2, CO, particulate load and composition, and acid gases) were made for each test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗