Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

INL Intern Poster Session

Characterization of off-gas constituents from nuclear fuel reprocessing can be measured using a residual gas analyzer. Characterization of this off-gas is important in a closed fuel cycle, where gasses such as Nox, Kr, I, and C-14 need to be removed from reprocessing plants to meet regulatory requirements. Both Kr and Xe have low chemical reactivity, making capture and separation difficult. Solid sorbents can be used to capture these gases as an alternative to cryogenic distillation, which is energy intensive and hazardous. AgZ-PAN and HZ-PAN are two solid sorbents that have demonstrated selective capture of Xe and Kr. A residual gas analyzer can be used to obtain breakthrough curves that demonstrate how well this adsorption and separation occur. The breakthrough curve is dependent on packing density, column size, and flow rate. Data obtained from the RGA was verified with a gas chromatographer.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Size and DNA distributions of electrophoretically separated cultured human kidney cells

Electrophoretic purification of purifying cultured cells according to function presumes that the size of cycle phase of a cell is not an overriding determinant of its electrophoretic velocity in an electrophoretic separator. The size distributions and DNA distributions of fractions of cells purified by density gradient electrophoresis were determined. No systematic dependence of electrophoretic migration upward in a density gradient column upon either size or DNA content were found. It was found that human leukemia cell populations, which are more uniform function and found in all phases of the cell cycle during exponential growth, separated on a vertical sensity gradient electrophoresis column according to their size, which is shown to be strictly cell cycle dependent.

Kunze, M. E.↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗

Solutions for laminar boundary layers with separation and reattachment

Numerical solutions of the laminar, incompressible boundary-layer equations are presented for flows involving separation and reattachment. Regular solutions are obtained with an inverse approach in which either the displacement thickness or the skin friction is specified, and the pressure is deduced from the solution. A stream function/vorticity formulation of the boundary-layer equations is used to eliminate the unknown pressure. Solutions of the resulting finite-difference equations, in which the flow direction is taken into account, are obtained by a successive column iteration scheme. Results are compared with Klineberg and Steger's (1974) separated boundary-layer calculations, and with Briley's (1971) solution of the Navier-Stokes equations for a separated region.

Carter, J. E.↗

Selective Biosorption of Valuable Rare Earth Elements Among Co-Occurring Lanthanides

To meet the increasing demand for rare earth elements (REEs) essential for low carbon-intensity energy technologies, new methods are needed for selective REE extraction from unconventional resources. Only a few REEs have significant economic value, but isolation of target rare earths from co-occurring lanthanides is challenging due to their similar chemical behavior. We present a novel approach to enhance separation of specific REEs from lanthanide mixtures. Escherichia coli cells engineered with lanthanide binding tags (LBTs) were immobilized in nonadsorbing, permeable polyethylene glycol diacrylate beads and packed into continuous flow, fixed-bed columns. Breakthrough of 15 rare earths in the +3 oxidation state resulted in notable differences in adsorption selectivity, with greatest separation between europium (Eu) and lanthanum (La) due to competitive displacement. REE adsorption onto fixed-bed columns was predicted by coupling a surface complexation model to a calibrated one-dimensional dual porosity transport model that accounts for interbead advective and intrabead diffusive transport. A tradeoff between high-abundance, low-affinity native carboxyl sites and low-abundance, high-affinity engineered LBT sites dictates process recovery efficiency and selectivity. Key chemical and operational parameters are identified to maximize selective extraction of high-value lanthanides, achieving a threefold enhancement of Eu recovery relative to La in a mixed REE solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MINE: maximally informative next experiment—toward a new GWAS experimental design and methodology

Abstract The computational methodology of Genome Wide Association Studies (GWAS) currently has several limitations: (i) the number of observations (rows) on a quantitative trait tends to be smaller than the number of single nucleotide polymorphisms (SNPs) (columns) in the design matrix; (ii) each SNP is usually modeled separately, failing to acknowledge interaction between each other (ie epistasis); (iii) there is implicit linkage disequilibrium (LD) between neighboring SNPs due to their linkage. To overcome these issues, we developed a tool that uses ensemble methods to fit mixed linear models to GWAS data, and these ensemble methods include the development of a new experimental design approach in GWAS, which uses the resultant models and data to select the next informative experiment over time. This new adaptive and staged approach for GWAS experimental design was developed and tested in a 3 yr adaptive model-guided discovery experiment against a fixed classical design. In Sorghum bicolor a total of 79, 86, and 78 accessions were tested in years 1, 2, and 3, respectively out of 343 accessions available in the Bioenergy Association Panel (BAP) each identified for 232,303 SNPs, 1 every 2–3 kb in the genomes. We demonstrated the feasibility of MINE enacted with 8 people in the field per year over 3 yr vs in 1 large classical design enacted with 20 people in 1 yr. The MINE results for chromosomal regions identified controlling dry weight were confirmed against results from previous sorghum GWAS experiments and 1 large classical design for the BAP panel.

Genetics & Heredity↗

Chemical and bonding analysis of liquids using liquid cell electron microscopy

Liquid cell transmission electron microscopy (TEM) has become an essential tool for studying the structure and properties of both hard and soft condensed-matter samples, as well as liquids themselves. Liquid cell sample holders, often consisting of two thin window layers separating the liquid sample from the high vacuum of the microscope column, have been designed to control in situ conditions, including temperature, voltage/current, or flow through the window region. While high-resolution and time-resolved TEM imaging probes the structure, shape, and dynamics of liquid cell samples, information about the chemical composition and spatially resolved bonding is often difficult to obtain due to the liquid thickness, the window layers, the holder configuration, or beam-induced radiolysis. Here, we review different approaches to quantitative liquid cell electron microscopy, including recent developments to perform energy-dispersive x-ray and electron energy-loss spectroscopy experiments on samples in a liquid environment or the liquid itself. We also cover graphene liquid cells and other ultrathin window layer holders.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Solid Isotope Harvesting Methods in Preparation for FRIB (Closeout Report)

This project developed the techniques necessary to isolate hydrolysable radiometals from irradiated accelerator components. It was a collaborative project headed by Dr. Jennifer Shusterman at Hunter College in coordination with Dr. Nick Scielzo at Lawrence Livermore National Laboratory and Dr. Gregory Severin at Michigan State University. To develop the methods for harvesting hydrolysable radiometals, both non-radioactive and radioactive experiments were conducted. Non-radioactive tests involved dissolving common accelerator materials (tungsten, copper, aluminum, and gold), adding trace amounts of Zr 4+ and Y 3+ , and then separating the added ions out again using a variety of column-based approaches. These methods were then tested on surrogate materials that were created by irradiating tungsten, copper, aluminum and gold foils with a low-purity 88 Zr beam at the National Superconducting Cyclotron Laboratory. The implanted 88 Zr (and co-implanted and daughter-product 88 Y) were recovered, validating the developed methods. MSU’s role in the project was to develop the chemistry for recovering Zr and Y from tungsten; build the target station for irradiating the foils; conduct the irradiations with the collaborators; to validate the tungsten methodology using the irradiated foils; and to disseminate the results.

07 ISOTOPE AND RADIATION SOURCES↗

A pyroloysis technique for determining microamounts of hydrogen in lunar soil using the helium ionization detector

A method has been developed which will determine hydrogen in sub-milligram samples of lunar soil. It consists of heating the sample in a pyroprobe followed by the gas chromatographic determination of hydrogen using the helium ionization detector. Using a 7 foot, 1/8 OD stainless steel column packed with Carbosieve S, 120/140 mesh, hydrogen was well-separated from the other gases released from lunar soil. Standards of hydrogen in helium were used for calibration. The limit to detection under the conditions used was about 2 ng. The method was linear from 2 ng to 270 ng. The method was checked using some actual lunar samples. Results were typical of those obtained for lunar soils using other methods.

Bustin, R.↗

A 21 Centimeter Absorber Identified with a Spiral Galaxy: Hubble Space Telescope Faint Object Spectrograph and Wide-Field Camera Observations of 3CR 196

We present imaging and spectroscopy of the quasar 3CR 196 (z(sub e) = 0.871), which has 21 cm and optical absorption at z(sub a) = 0.437. We observed the region of Ly alpha absorption in 3CR 196 at z(sub a) = 0.437 with the Faint Object Spectrograph on the Hubble Space Telescope. This region of the spectrum is complicated because of the presence of a Lyman limit and strong lines from a z(sub a) approx. z(sub e) system. We conclude that there is Ly alpha absorption with an H I column density greater than 2.7 x 10(exp 19) cm(exp -2) and most probably 1.5 x 10(exp 20) cm(exp -2). Based on the existence of the high H I column density along both the optical and radio lines of sight, separated by more than 15 kpc, we conclude that the Ly alpha absorption must arise in a system comparable in size to the gaseous disks of spiral galaxies. A barred spiral galaxy, previously reported as a diffuse object in the recent work of Boisse and Boulade, can be seen near the quasar in an image taken at 0.1 resolution with the Wide Field Planetary Camera 2 on the HST. If this galaxy is at the absorption redshift, the luminosity is approximately L(sub *) and any H I disk should extend in front of the optical quasar and radio lobes of 3CR 196, giving rise to both the Ly alpha and 21 cm absorption. In the z(sub a) approx. z(sub e) system we detect Lyman lines and the Lyman limit, as well as high ion absorption lines of C III, N V, S VI, and O VI. This absorption probably only partially covers the emission-line region. The ionization parameter is approximately 0.1. Conditions in this region may be similar to those in broad absorption line QSOs.

Cohen, Ross D.↗

Cloud Scaling Properties and Cloud Parameterization

Cloud liquid and cloud traction variability is studied as a function of horizontal scale in the ECMWF forecast model during several 10-day runs at the highest available model resolution, recently refined from approximately 60 km (T213) down to approximately 20 km (T639). At higher resolutions, model plane-parallel albedo biases are reduced, so that models may be tuned to have larger, more realistic, cloud liquid water amounts, However, the distribution of cloud liquid assumed -within- each gridbox, for radiative and thermodynamic computations, depends on ad hoc assumptions that are not necessarily consistent with observed scaling properties, or with scaling properties produced by the model at larger scales. To study the larger-scale cloud properties, ten locations on the Earth are chosen to coincide with locations having considerable surface data available for validation, and representing a variety of climatic regimes, scaling exponents are determined from a range or scales down to model resolution, and are re-computed every three hours, separately for low, medium and high clouds, as well as column-integrated cloudiness. Cloud variability fluctuates in time, due to diurnal, synoptic and other' processes, but scaling exponents are found to be relatively stable. various approaches are considered for applying computed cloud scaling to subgrid cloud distributions used for radiation, beyond simple random or maximal overlap now in common use. Considerably more work is needed to compare model cloud scaling with observations. This will be aided by increased availability of high-resolution surface, aircraft and satellite data, and by the increasing resolution of global models,

Cahalan, R. F.↗

Metal Oxide Sorbents for the Separation of Radium and Actinium

The inorganic, normal-phase sorbents alumina, titania, and zirconia were evaluated and screened for the separation of Ba, La, 228 Ra, 228 Ac, and 212 Pb in a dilute acid matrix. The results show that the sorbents are capable of fractionating the ions between pH 1 and 8. A stationary zirconia column was used to isolate Ba from La and Ra from Ac/Pb; elution profiles of each separation are presented. The utility and implications of these sorbents are discussed with respect to large-scale production of 225 Ac from radium targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

TALSPEAK-based separation of the trivalent actinides from rare earth elements using LN resin

The separation of 241 Am, 244 Cm and 249 Cf from rare earth elements using LN resin and lactate buffer solutions with diethylenetriaminepentaacetic acid is described with numerous columns studies. The elutions are based on TALSPEAK liquid–liquid extraction chemistry, and provide high yield (> 90%), rapid, simple separations of the trivalent actinides from the lanthanides, which is often challenging due to similarities in chemical behavior among the trivalent f-block elements. Further, all three actinides can be separated from rare earth elements, including from massless fission product samples and samples with small amounts (~ 1–5 mg) of stable lanthanides. Separations with no detectable overlap between the actinide and lanthanide elutions is possible with massless samples, and in samples with mass high separation factors can be achieved (Am/Eu: 171; Am/La: 10 6 ).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗