Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparison of gain degradation and deep level transient spectroscopy in pnp Si bipolar junction transistors irradiated with different ion species

Here, we studied the effect of light ion and heavy ion irradiations on pnp Si BJTs. A mismatch in DLTS deep peak amplitude for devices with same final gain but irradiated with different ion species was observed. Also, different ions cause different gain degradation when the DLTS spectra are matched. Pre-dosed ion-irradiated samples show that ion induced ionization does not account for the differences in DLTS peak height but isochronal annealing studies suggest that light ions produce more VP defects than heavy ions to compensate for the lack of clusters that heavy ions produce. The creation of defect clusters by heavy ions is evident by the higher content of E4 and V* 2 defects compared to light ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Comparison of Radiation-Induced and High-Field Electrically Stress-Induced Interface Defects in Si/SiO 2 MOSFETs via Electrically Detected Magnetic Resonance

Here, we utilize electrically detected magnetic resonance (EDMR) measurements to compare high-field stressed, and gamma irradiated Si/SiO 2 metal–oxide–silicon (MOS) structures. We utilize spin-dependent recombination (SDR) EDMR detected using the Fitzgerald and Grove dc I-V approach to compare the effects of high-field electrical stressing and gamma irradiation on defect formation at and near the Si/SiO 2 interface. As anticipated, both greatly increase the concentration of P b centers (silicon dangling bonds at the interface) densities. The irradiation also generated a significant increase in the dc I-V EDMR response of E' centers (oxygen vacancies in the SiO 2 films), whereas the generation of an E' EDMR response in high-field stressing is much weaker than in the gamma irradiation case. These results likely suggest a difference in their physical distribution resulting from radiation damage and high electric field stressing.

42 ENGINEERING↗

Melter feed viscosity during conversion to glass: Comparison between low-activity waste and high-level waste feeds

During nuclear waste vitrification, a melter feed (generally a slurry-like mixture of a nuclear waste and various glass forming and modifying additives) is charged into the melter where undissolved refractory constituents are suspended together with evolved gas bubbles from complex reactions. Knowledge of flow properties of various reacting melter feeds is necessary to understand their unique feed-to-glass conversion processes occurring within a floating layer of melter feed called a cold cap. The viscosity of two low-activity waste (LAW) melter feeds were studied during heating and correlated with volume fractions of undissolved solid phase and gas phase. In contrast to the high-level waste (HLW) melter feed, the effects of undissolved solid and gas phases play comparable roles and are required to represent the viscosity of LAW melter feeds. This study can help bring physical insights to feed viscosity of reacting melter feeds with different compositions and foaming behavior in nuclear waste vitrification.

Jin, Tongan↗

Comparison of Real-Time Pressure Rail Selection Algorithms for the Hybrid Hydraulic Electric Architecture: Case Study on a Track Loader

Abstract The hybrid hydraulic electric architecture (HHEA) seeks to combine the high power/torque/force density of hydraulics with the efficiency of electric machines. A set of common pressure rails is used to provide a majority of the power and this power is modulated by small electric machines to provide precise control for the operator. The HHEA has been studied in previous work using off-line dynamic programming optimization to determine energy efficient pressure rail selections, but this approach requires drive cycle information apriori. A Lagrange multiplier method has also been investigated where a set of gains (Lagrange multipliers) are optimized off-line with the idea the these gains, once determined, could be used for real-time operation. In this work, three new real-time pressure rail selection algorithms that do not require future drive cycle information are investigated; greedy, torque minimizing, and thresholding. The greedy control is found to only use 1% more energy than the globally optimal dynamic programming solution; but a model of energy loss is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Center Nozzle Staging to Outer Nozzle Staging in a Multi-Flame Combustor

Combustion instability in gas turbines is often mitigated using fuel staging, a strategy where the fuel is split unevenly between different nozzles of a multiple-nozzle combustor. This work examines the efficacy of different fuel staging configurations by comparing axisymmetric and non-axisymmetric fuel staging in a four-around-one model gas turbine combustor. Fuel staging is accomplished by increasing the equivalence ratio of the center nozzle (axisymmetric staging) or an outer nozzle (non-axisymmetric staging). When the global equivalence ratio is ϕ = 0.70 and all nozzles are fueled equally, the combustor undergoes longitudinal, self-excited oscillations. These oscillations are suppressed when the center nozzle equivalence ratio is increased above ϕ Staging = 0.79. This bifurcation equivalence ratio varies between ϕ Staging = 0.86 and ϕ Staging = 0.76 for the outer nozzles, and is attributed to minor hardware differences between each nozzle. High speed CH* chemiluminescence images in combination with dynamic pressure measurements are used to determine the instantaneous phase difference between the heat release rate fluctuation and the combustor pressure fluctuation throughout the combustor. This analysis shows that the staged flame has similar phase relationships for all staging configurations. It is found that axisymmetric staging can be as effective as non-axisymmetric staging; however, the aforementioned hardware variations can impact both the bifurcation equivalence ratio and the effectiveness of staging.

Culler, Wyatt↗

Optical emission spectroscopic studies and comparisons of CH{sub 3}F/CO{sub 2} and CH{sub 3}F/O{sub 2} inductively coupled plasmas

A CH{sub 3}F/CO{sub 2} inductively coupled plasma (ICP), sustained in a compact plasma reactor, was investigated as a function of power (5–400 W) and feed gas composition, at a pressure of 10 mTorr, using optical emission spectroscopy and rare gas actinometry. Number densities of H, F, and O increased rapidly between 74% and 80% CO{sub 2}, ascribed to the transition from polymer-covered to polymer-free reactor walls, similar to that found previously in CH{sub 3}F/O{sub 2} ICPs at 48% O{sub 2}. Below 40% O{sub 2} or CO{sub 2}, relative emission intensity ratios were almost identical for most key species in CH{sub 3}F/O{sub 2} and CH{sub 3}F/CO{sub 2} ICPs except for higher OH/Xe (a qualitative measure of OH and H{sub 2}O densities) over the full range of CH{sub 3}F/O{sub 2} composition. The number density of H, F, and O increased with power in CH{sub 3}F/CO{sub 2} (20%/80%) plasmas (polymer-free walls), reaching 4.0, 0.34, and 1.6 × 10{sup 13}/cm{sup 3}, respectively, at 300 W. The CO number density increased with power and was estimated, based on self-actinometry, to be 8.8 × 10{sup 13}/cm{sup 3} at 300 W. The CO{sub 2} number density was independent of power below 40 W (where very little decomposition occurred), and then decreased rapidly with increasing power, reaching 2.8 × 10{sup 13}/cm{sup 3} at 300 W, corresponding to 83% dissociation. Films deposited on p-Si, 10 cm from the open, downstream end of the plasma reactor, were analyzed by x-ray photoelectron spectroscopy. Between 10% and 40% CO{sub 2} or O{sub 2} addition to CH{sub 3}F, film deposition rates fell and O content in the films increased. Faster deposition rates in CH{sub 3}F/CO{sub 2} plasmas were ascribed mainly to a larger thermodynamic driving force to form solid carbon, compared with CH{sub 3}F/O{sub 2} plasmas. Oxygen content in the films increased with increasing CO{sub 2} or O{sub 2} addition, but for the same deposition rate, no substantial differences were observed in the composition of the films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Coherent band excitations in CePd 3 : A comparison of neutron scattering and ab initio theory

In common with many strongly correlated electron systems, intermediate valence compounds are believed to display a crossover from a high-temperature regime of incoherently fluctuating local moments to a low-temperature regime of coherent hybridized bands. In this work, we show that inelastic neutron scattering measurements of the dynamic magnetic susceptibility of CePd 3 provides a benchmark for ab initio calculations based on dynamical mean field theory. The magnetic response is strongly momentum dependent thanks to the formation of coherent f-electron bands at low temperature, with an amplitude that is strongly enhanced by local particle-hole interactions. Finally, the agreement between experiment and theory shows that we have a robust first-principles understanding of the temperature dependence of f-electron coherence.

36 MATERIALS SCIENCE↗

Measurement of the inclusive jet cross-section in pp collisions at $\sqrt{s}=2.76\ \mbox{TeV}$ and comparison to the inclusive jet cross-section at $\sqrt{s} =7\ \mbox{TeV}$ using the ATLAS detector

The inclusive jet cross-section has been measured in proton–proton collisions at $\sqrt{s}=2.76\ \mbox{TeV}$ in a dataset corresponding to an integrated luminosity of 0.20 pb -1 collected with the ATLAS detector at the Large Hadron Collider in 2011. Jets are identified using the anti-k t algorithm with two radius parameters of 0.4 and 0.6. The inclusive jet double-differential cross-section is presented as a function of the jet transverse momentum p T and jet rapidity y, covering a range of 20 ≤ p T < 430 GeV and |y| < 4.4. The ratio of the cross-section to the inclusive jet cross-section measurement at $\sqrt{s} =7\ \mbox{TeV}$, published by the ATLAS Collaboration, is calculated as a function of both transverse momentum and the dimensionless quantity x T = 2p T / √s, in bins of jet rapidity. The systematic uncertainties on the ratios are significantly reduced due to the cancellation of correlated uncertainties in the two measurements. Results are compared to the prediction from next-to-leading order perturbative QCD calculations corrected for non-perturbative effects, and next-to-leading order Monte Carlo simulation. Furthermore, the ATLAS jet cross-section measurements at $\sqrt{s}=2.76\ \mbox{TeV}$ and $\sqrt{s} =7\ \mbox{TeV}$ are analysed within a framework of next-to-leading order perturbative QCD calculations to determine parton distribution functions of the proton, taking into account the correlations between the measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Comparison of Models for Transport Resistance in Fuel-Cell Catalyst Layers

The vexing rise in resistance to oxygen transport that accompanies reductions in the amount of catalyst in polymer-electrolyte fuel cells is theoretically investigated. Expressions for transport resistance stemming from common models for oxygen transport in electrodes are developed and compared to published experiments. Particular emphasis is placed upon how predicted transport resistances vary with platinum loading, mass fraction of platinum in supported catalysts, ionomer to carbon ratio, and overpotential. Most frequently applied models do not match all empirically observed trends. Here, models that include nanoparticle diffusion or adsorption demonstrate qualitatively correct behavior and provide quantitatively reasonable predictions for transport resistance.

08 HYDROGEN↗