Search NASA⌕ Search

SEARCH · Search NASA

Results for “conduction cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Cooling of Gas Turbines I - Effects of Addition of Fins to Blade Tips and Rotor, Admission of Cooling Air Through Part of Nozzles, and Change in Thermal Conductivity of Turbine Components

An analysis was developed for calculating the radial temperature distribution in a gas turbine with only the temperatures of the gas and the cooling air and the surface heat-transfer coefficient known. This analysis was applied to determine the temperatures of a complete wheel of a conventional single-stage impulse exhaust-gas turbine. The temperatures were first calculated for the case of the turbine operating at design conditions of speed, gas flow, etc. and with only the customary cooling arising from exposure of the outer blade flange and one face of the rotor to the air. Calculations were next made for the case of fins applied to the outer blade flange and the rotor. Finally the effects of using part of the nozzles (from 0 to 40 percent) for supplying cooling air and the effects of varying the metal thermal conductivity from 12 to 260 Btu per hour per foot per degree Farenheit on the wheel temperatures were determined. The gas temperatures at the nozzle box used in the calculations ranged from 1600F to 2000F. The results showed that if more than a few hundred degrees of cooling of turbine blades are required other means than indirect cooling with fins on the rotor and outer blade flange would be necessary. The amount of cooling indicated for the type of finning used could produce some improvement in efficiency and a large increase in durability of the wheel. The results also showed that if a large difference is to exist between the effective temperature of the exhaust gas and that of the blade material, as must be the case with present turbine materials and the high exhaust-gas temperatures desired (2000F and above), two alternatives are suggested: (a) If metal with a thermal conductivity comparable with copper is used, then the blade temperature can be reduced by strong cooling at both the blade tip and root. The center of the blade will be less than 2000F hotter than the ends; (b) With low conductivity materials some method of direct cooling other than partial admission of cooling air is essential. From this study, it can be deduced that indirect cooling of turbine blades will not make possible large increases in gas temperature.

Brown, Byron↗

Reduced Boil-Off System Sizing

NASA is currently developing cryogenic propellant storage and transfer systems for future space exploration and scientific discovery missions by addressing the need to raise the technology readiness level of cryogenic fluid management technologies. Cryogenic propellants are baselined in many propulsion systems due to their inherently high specific impulse; however, their low boiling points can cause substantial boil-off losses over time. Recent efforts such as the Reduced Boil-off Testing and the Active Thermal Control Scaling Study provide important information on the benefit of an active cooling system applied to LH2 propellant storage. Findings show that zero-boil off technologies can reduce overall mass in LH2 storage systems when low Earth orbit loiter periods extend beyond two months. A significant part of this mass reduction is realized by integrating two stages of cooling: a 20 K stage to intercept heat at the tank surface, and a 90 K stage to reduce the heat entering the less efficient 20 K stage. A missing element in previous studies, which is addressed in this paper, is the development of a direct method for sizing the 90 K cooling stage. Such a method requires calculation of the heat entering both the 90 K and 20 K stages as compared to the overall system masses, and is reliant upon the temperature distribution, performance, and unique design characteristics of the system in question. By utilizing the known conductance of a system without active thermal control, the heat being intercepted by a 90 K stage can be calculated to find the resultant lift and mass of each active thermal control stage. Integral to this is the thermal conductance of the cooling straps and the broad area cooling shield, key parts of the 90 K stage. Additionally, a trade study is performed to show the ability of the 90 K cooling stage to reduce the lift on the 20 K cryocooler stage, which is considerably less developed and efficient than 90 K cryocoolers.

Cryogenic fluid management↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of scramjet nozzle configurations and film cooling for reduction of wall heating

Experiments on relaminarization, or reverse transition of turbulent flow, have been conducted with a scramjet combustor and nozzle model. The Mach-2.7 direct-connect scramjet combustor employed swept-ramp fuel injectors, and the entering flow simulated Mach-6 to Mach-7 flight conditions. Tests were also conducted without combustor fuel to produce a higher nozzle entrance Mach number and lower pressures. Additional tests were conducted to evaluate the effectiveness of film cooling on the cowl region. At each test condition studied, the entrance radius had no significant effect on the measured downstream wall heating rates. Analysis of the data when fuel was injected into the combustor shows good agreement with turbulent theory; for the tests without fuel injection and combustion, the data downstream of the nozzle entrance radius are intermediate to the calculated turbulent and laminar solutions. Results of film-cooling tests, conducted with both hydrogen and nitrogen injectants, showed that, per unit mass, the hydrogen was approximately three to four times more effective than nitrogen in reducing the downstream wall heating rates.

Baker, N. R.↗

Experimental apparatus and methodology to test and quantify thermal performance of micro and macro-encapsulated phase change materials in building envelope applications

Thermal energy storage (TES) is used as a viable technology to shift peak electricity demand caused by the space cooling requirements in buildings. Passive TES is implemented in building envelope via micro and macroencapsulation methods. This study describes the use of a state-of-the-art laboratory to test different PCM inclusions in simplified building walls. A microencapsulated PCM and two macroencapsulated PCMs are tested in a controlled environment to gather data for validation purposes of PCM modelling algorithms in building energy modelling programs. Data indicates that the chamber environment and the heating and cooling system can conduct full-cycle tests of wall panels with PCM inclusions. This study also generates data from parallel tests on 4 wall panels which can be used in building energy modelling programs to validate the PCM modelling algorithms. The cyclic tests also capture the thermal effects of PCMs and complex PCM behaviors like sub-cooling in PCM hydrate-salts.

25 ENERGY STORAGE↗

FUSE Observations of O VI Absorption in the Local Interstellar Medium

We report the results of an initial Far Ultraviolet Spectroscopic Explorer (FUSE) survey of O VI Lambda 1032 absorption along the lines of sight to eleven nearby white dwarfs, ten of which are within the Local Bubble (LB; d < or approximately equal 100 pc). A goal of this survey is to investigate the possible formation of O VI in the conductive interfaces between cool (about 10(exp 4) K) clouds immersed in the presumably hot (10(exp 6) K) gas within the LB. This mechanism is often invoked to explain the widespread presence of 0 VI throughout the Galactic disk. We find no 0 VI absorption toward two stars, and the column densities along three additional sight lines are quite low; N(O VI) about 5 x 10(exp 13)/sq cm. In several directions, we observe rather broad, shallow absorption with N(O VI) about 1 - 2 x 10(exp 13)/sq cm. Models of conductive interfaces predict narrow profiles with N(OVI) > or about equal to 10(exp 13)/sq cm per interface, in the absence of a significant transverse magnetic field. Hence, our observations of weak 0 VI absorption indicate that conduction is being quenched, possibly by non-radial magnetic fields. Alternatively, the gas within the LB may not be hot. Breitschwerdt & Schmutzler have proposed a model for the LB in which an explosive event within a dense cloud created rapid expansion and adiabatic cooling, resulting in a cavity containing gas with a kinetic temperature of T about 50,000 K, but with an ionization state characteristic of much hotter gas. This model has a number of attractive features, but appears to predict significantly more O VI than we observe.

Oegerle, W. R.↗

Turbine vane leading edge gas film cooling with spanwise angled coolant holes

An experimental film cooling study was conducted on a 3x size model turbine vane. Injection at the leading edge was from a single row of holes angled in a spanwise direction for two configurations of holes at 18 or 35 deg to the surface. The reduction in the local Stanton number for injection at a coolant-to-mainstream density ratio of 2.18 was calculated from heat flux measurements downstream of injection. Results indicate that optimum cooling occurs near a coolant-to-mainstream velocity ratio of 0.5. Shallow injection angles appear to be most beneficial when injecting into a highly accelerated mainstream.

Hanus, G. J.↗

Design of a Microgravity Spray Cooling Experiment

An analytical and experimental study was conducted for the application of spray cooling in a microgravity and high-g environment. Experiments were carried out aboard the NASA KC-135 reduced gravity aircraft, which provided the microgravity and high-g environments. In reduced gravity, surface tension flow was observed around the spray nozzle, due to unconstrained liquid in the test chamber and flow reversal at the heat source. A transient analytical model was developed to predict the temperature and the spray heat transfer coefficient within the heated region. Comparison of the experimental transient temperature variation with analytical results showed good agreement for low heat input values. The transient analysis also verified that thermal equilibrium within the heated region could be reached during the 20-25s reduced gravity portion of the flight profile.

Baysinger, Kerri M.↗

Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers (Final Technical Report)

This report summarizes the carbon capture research and development conducted by The State University of New York at Buffalo (UB) and GTI Energy (GTI) for award “DE-FE0031969: Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers” sponsored by the U.S. Department of Energy (DOE). The objective of this project is to develop an innovative sorbent structure of trapped small amines in HNC embedded in PEF for DAC. This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An innovative sorbent structure of trapped small amines in hierarchical nanoporous capsules (HNC) embedded in porous electrospun fibers (PEF) was developed for direct air capture (DAC). This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An interfacial polymerization process was developed, which utilized loaded amines inside mesoporous silica and trimesoyl chloride (TMC) dissolved in organic solvents as the precursors, to generate a polyamide (PA) coating layer on mesoporous silica and thus trap amines. Reaction conditions, including TMC concentration, organic solvents, reaction time, etc., for interfacial polymerization were optimized to effectively trap loaded amines, and cyclic heating-cooling operation was conducted to evaluate the coating quality. Larger pore volume mesoporous silica was also synthesized to increase amine loading and thus increase CO 2 capacity. The optimized sorbent material exhibited CO 2 capacity as high as 4.88 mmol/g under humid DAC conditions and negligible loss (<1%) during 10 cyclic heating-cooling operations. The optimized PA-coated sorbent also showed fast adsorption and desorption kinetics, with <20% t1/2 increase compared to uncoated sorbent. PEF fabrication conditions, including organic solvents for dissolving core and shell polymers, voltage, distance from the nozzle to the collection panel, etc. were adjusted to better incorporate HNC. After incorporating the optimized sorbent material into PEF, the structured sorbent had a CO 2 capacity of approximately 4.0 mmol/g under humid DAC conditions, with capacity loss of 0.17% per cycle and t1/2 increase less than 10%. A techno-economic analysis (TEA) for the process design for a DAC system based on our developed sorbent structure of trapped small amines in HNC embedded in PEF was conducted. The process design included process description and major equipment sizing and energy and mass balances in addition to scale-up research results and estimated capture cost. Aspen Adsorption Simulator was used to fit the experimentally measured breakthrough curves and extract equilibrium and kinetic data of the optimized sorbent. Our results indicated that for a DAC plant with CO 2 productivity of 3,000 tonne/year, the levelized cost of CO 2 capture was $\$$612/tonne, with the largest contribution of 44.33% from the fixed operation cost. Increasing CO 2 productivity, while maintaining similar fixed operation cost, is expected to significantly reduce the CO 2 capture cost. A sensitivity study was also conducted to understand the influence of total plant cost, sorbent cost, CO 2 concentration in the feed, sorbent mat lifetime, sorbent regeneration electricity, and adsorption blower pressure drop on the levelized cost of CO 2 capture, revealing a capture cost range of $\$$520-870/tonne.

36 MATERIALS SCIENCE↗

Evaporative cooling of flare plasma

We investigate a one-dimensional loop model for the evaporative cooling of the coronal flare plasma. The important assumptions are that conductive losses dominate radiative cooling and that the evaporative velocities are small compared with the sound speed. We calculate the profile and evolution of the temperature and verify the accuracy of our assumptions for plasma parameters typical of flare regions. The model is in agreement with soft X-ray observations on the evolution of flare temperatures and emission measures. The effect of evaporation is to greatly reduce the conductive heat flux into the chromosphere and to enhance the EUV emission from the coronal flare plasma.

Antiochos, S. K.↗

Final Report

This grant was made to fund two accepted proposals to observe with the ASCA satellite: (1) Debunking the myth of two-temperature coronae of active stars, and (2) Dynamic coronae of dMe stars. We obtained the requested observations and have now completed two papers that will be published in the Astrophysical Journal. The RS CVn binary star UX Ari was observed for 14 hours with all four detectors onboard the ASCA satellite. The X-ray emission was at a constant, quiescent level during the first 12 hours, after which time a powerful flare with a peak luminosity of 1.4 x 10(exp 32) ergs/s started. The flare was observed until shortly after its peak. We present a spectral and temporal analysis of the UX Ari observations and analyze the data with a two-ribbon flare model including estimates for cooling losses. A time-dependent reconstruction of the emission measure (EM) distribution shows that two separate plasma components evolve during the flare (one being identified with the quiescent EM). Most of the flare EM reaches temperatures between 50 MK and 100 MK or more. Magnetic confinement requires the loop arcade to be geometrically large, with length scales on the order of one stellar radius. The electron densities inferred from the model decrease from initial values around 10(exp 12)/cc early in the flare to about 10(exp 11)/cc at the flare peak. The best-fit models require surface magnetic field strengths of a few hundred G, compatible with the maximum photospheric fields expected from equipartition. The flare parameters imply a (conductive and radiative) cooling loss time of less than one hour at flare peak. The elemental abundances increase significantly during the flare rise, with the abundances of the low-FIP elements Fe, Mg, Si, and Ni typically increasing to higher levels than the high-FIP elements such as S or Ne. The Fe abundance increases from (17 +/- 4)% of the solar photospheric value during quiescence up to (89 +/- 18)% at flare peak. A fractionation process that occurs during the chromospheric evaporation phase may selectively enrich low-FIP elements as in the solar corona; alternatively, the chromospheric evaporation may itself bring metal-rich plasma into the metal-poor corona.

Linsky, Jeffrey L.↗

Shuttle active thermal control system development testing. Volume 5: Integrated radiator/expendable cooling system tests

Tests were conducted to gather data on a space shuttle active control system (ATCS) incorporating both radiators and an expendable cooling device to provide vehicle heat removal. Two systems were tested and design information was provided for both nominal and limit conditions. The tests verified the concept that an integrated radiator/expendable cooling system can adequately maintain desired water quantities while responding to variations in heat loads and environments. In addition, the need for duct heating was demonstrated, while exhaust nozzle heating was also shown to be unnecessary.

Scheps, P. B.↗

The relationship between hard and soft X-ray bursts observed by OSO 7

The paper reviews the observations of solar X-rays in the range 1-100 keV made by the solar X-ray instrument on board the OSO-7 satellite and explores the relationship between the hard and soft X-ray components in order to glean some information on the physics of solar flares. Some of the results are as follows: The growth of the soft X-ray emission in a burst must be due to the addition of new hot material to the flare plasma. The anticorrelation between cooling time and maximum plasma temperature gives new evidence to support conduction as the principal cooling mechanism of the hot flare plasma. Observations of hard X-ray emission from bursts which occurred behind the limb indicate that hard X-ray emission comes at least in part from considerable heights in the corona.

Datlowe, D. W.↗

Correlation of the Characteristics of Single-Cylinder and Flight Engines in Tests of High-Performance Fuels in an Air-Cooled Engine I : Cooling Characteristics

Variable charge-air flow, cooling-air pressure drop, and fuel-air ration investigations were conducted to determine the cooling characteristics of a full-scale air-cooled single cylinder on a CUE setup. The data are compared with similar data that were available for the same model multicylinder engine tested in flight in a four-engine airplane. The cylinder-head cooling correlations were the same for both the single-cylinder and the flight engine. The cooling correlations for the barrels differed slightly in that the barrel of the single-cylinder engine runs cooler than the barrel of te flight engine for the same head temperatures and engine conditions.

Wilson, Robert W.↗

Characterization of Highly Thermally Conductive Organic Substrates for a Double-Sided Cooled Power Module

Abstract Silicon-Carbide (SiC) power devices have become a promising option for traditional Silicon (Si) due to the superior material properties. To fully take advantage of the SiC devices, a high-performance power device packaging solution is necessary. This study proposes a cost-effective double-sided cooled (DSC) 1.2 kV SiC half-bridge power module using organic epoxy-resin composite dielectric (ERCD) substrates. The high mechanical and thermal performance of the power module is achieved by the low-modulus, moderate thermal conductivity, and relatively thin (120 μm) layer of ERCD material compared with traditional metal-clad ceramic approaches. This novel organic dielectric can withstand high voltage (5 kV @ 120 μm) and operate up to 250°C continuously, which is indispensable for high power applications. The thermal modeling results show that the equivalent thermal resistance junction-to-case (Rjc_eq) of the DSC power module using dual direct bonded copper (DBC) is 17% higher than the dual ERCD configuration. Furthermore, a non-insulated DSC power module concept is proposed for maximizing thermal performance by considering thermal vias in the ERCD substrate and direct-soldered heat sink. A thought process for optimization of thermal via design is demonstrated and it shows up to 24% of improvement on thermal performance compared with the insulated DSC power module.

Double-sided cooling, epoxy-resin composite dielec↗

New Conductive Opacities for White Dwarf Envelopes

Thanks to their continuous cooling and relative simplicity, white dwarf stars are routinely used to measure the ages of stellar populations. The usefulness of white dwarfs as cosmochronometers depends on the availability of accurate cooling models. A key ingredient of those models is conductive opacities, which largely govern the cooling rate. In this work, we present improved conductive opacities for the regime of moderate coupling and moderate degeneracy that characterizes an important portion of the envelopes of DA and DB white dwarfs. Here, we find differences of up to a factor of 3 between our calculations and the commonly used opacities of Cassisi et al., which we attribute to an improved account of electron–electron scattering. The cooling models are strongly affected by those changes in the conductive opacities: the age of a 4000 K white dwarf can be reduced by as much as 2 Gyr. We provide analytical fits to our new opacities to facilitate the implementation of this important effect in white dwarf evolution codes.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Investigation of Air-Cooled Turbine Blades in Turbojet Engine. 7: Rotor-Blade Fabrication Procedures

An experimental investigation was conducted to determine the cooling effectiveness of a wide variety of air-cooled turbine-blade configurations. The blades, which were tested in the turbine of a - commercial turbojet engine that was modified for this investigation by replacing two of the original blades with air-cooled blades located diametrically opposite each other, are untwisted, have no aerodynamic taper, and have essentially the same external profile. The cooling-passage configuration is different for each blade, however. The fabrication procedures were varied and often unique. The blades were fabricated using methods most suitable for obtaining a small number of blades for use in the cooling investigations and therefore not all the fabrication procedures would be directly applicable to production processes, although some of the ideas and steps might be useful. Blade shells were obtained by both casting and forming. The cast shells were either welded to the blade base or cast integrally with the base. The formed shells were attached to the base by a brazing and two welding methods. Additional surface area was supplied in the coolant passages by the addition of fins or tubes that were S-brazed. to the shell. A number of blades with special leading- and trailing-edge designs that provided added cooling to these areas were fabricated. The cooling effectiveness and purposes of the various blade configurations are discussed briefly.

Long, Roger A.↗