Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous time system estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Future of EPA's Waste Estimation Support Tool - 17227

The Environmental Protection Agency's (EPA's) Waste Estimation Support Tool (WEST) is a GIS-based decision support tool for estimating the characteristics, amount, and residual radioactivity of waste generated from remediation and cleanup activities after a radiological incident, including those involving radiological dispersal devices, improvised nuclear devices, and nuclear power plants. WEST has been released to the public and has been used in numerous national level exercises and planning scenarios; however, it continues to be improved and refined to add additional functionality and performance. Since its inception, WEST has undergone a myriad of updates, routinely ensuring compatibility with ESRI's ArcGIS and FEMA's Hazus, a tool for estimating potential losses from earthquakes, wind, and flood events. Furthermore, recent enhancements have added reporting and mapping features and multi-state support. Over time, this progress has strained WEST's Microsoft{sup C} Excel based platform. The inherent limitations of Excel have limited the capacity of WEST and narrowed the scope of potential enhancements. Recent collaborative efforts between the Department of Homeland Security's (DHS's) Science and Technology Directorate (S and T) and EPA will see the introduction of a new software platform for easing memory limitations and new and innovative features for improving the accuracy of waste estimates. The planned enhancements include: 1) Systems approach: measure or predict the outcome of decisions associated with disaster response (e.g., decontamination efficacy vs. waste) and to a greater extent, the overall resource demand (e.g., cost, time, etc.); 2) Custom infrastructure data and international support: accommodate non-US building information where available and also add new data and information on recently used decontamination technologies as applied in a real-world incident; 3) Additional waste factors: addition of waste factors that are unique to wide area scenarios such as vehicles and trees as they will likely contribute in a significant manner to the overall waste stream;4) Site analysis and logistics: apply spatial information and analysis technologies to locate and prioritize potential waste staging or storage sites; and use GIS-based logistics planning to better organize, route, and estimate the cost, time, and logistical requirements (i.e., resource demand) associated with transporting large volumes of waste from a disaster-stricken area to waste staging or storage sites; 5) Decontamination technologies: introduce new decontamination technologies, better understand the feasibility and efficacy of new and preexisting decontamination technologies when applied to a wide area incident, and use historical incidents to ground truth waste results; and 6) Resource demand: ability to estimate resource demand information associated with decontamination technologies, waste staging and storage, and logistical information for transporting waste. This paper will describe the next version of WEST (WEST 4.0), and how the aforementioned enhancements will contribute to improving the planning and response capabilities of the tool. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring the Migrations of Wild Snake River Spring/Summer Chinook Salmon Juveniles, 2007-2008 Report of Research.

This report provides results from an ongoing project to monitor the migration behavior and survival of wild juvenile spring/summer Chinook salmon in the Snake River Basin. Data reported is from detections of PIT tagged fish during late summer 2007 through mid-2008. Fish were tagged in summer 2007 by the National Marine Fisheries Service (NMFS) in Idaho and by the Oregon Department of Fish and Wildlife (ODFW) in Oregon. Our analyses include migration behavior and estimated survival of fish at instream PIT-tag monitors and arrival timing and estimated survival to Lower Granite Dam. Principal results from tagging and interrogation during 2007-2008 are listed below: (1) In July and August 2007, we PIT tagged and released 7,390 wild Chinook salmon parr in 12 Idaho streams or sample areas. (2) Overall observed mortality from collection, handling, tagging, and after a 24-hour holding period was 1.4%. (3) Of the 2,524 Chinook salmon parr PIT tagged and released in Valley Creek in summer 2007, 218 (8.6%) were detected at two instream PIT-tag monitoring systems in lower Valley Creek from late summer 2007 to the following spring 2008. Of these, 71.6% were detected in late summer/fall, 11.9% in winter, and 16.5% in spring. Estimated parr-to-smolt survival to Lower Granite Dam was 15.5% for the late summer/fall group, 48.0% for the winter group, and 58.5% for the spring group. Based on detections at downstream dams, the overall efficiency of VC1 (upper) or VC2 (lower) Valley Creek monitors for detecting these fish was 21.1%. Using this VC1 or VC2 efficiency, an estimated 40.8% of all summer-tagged parr survived to move out of Valley Creek, and their estimated survival from that point to Lower Granite Dam was 26.5%. Overall estimated parr-to-smolt survival for all summer-tagged parr from this stream at the dam was 12.1%. Development and improvement of instream PIT-tag monitoring systems continued throughout 2007 and 2008. (4) Testing of PIT-tag antennas in lower Big Creek during 2007-2008 showed these antennas (and anchoring method) are not adequate to withstand high spring flows in this drainage. Future plans involve removing these antennas before high spring flows. (5) At Little Goose Dam in 2008, length and/or weight were taken on 505 recaptured fish from 12 Idaho stream populations. Fish had grown an average of 40.1 mm in length and 10.6 g in weight over an average of 288 d. Their mean condition factor declined from 1.25 at release (parr) to 1.05 at recapture (smolt). (6) Mean release lengths for detected fish were significantly larger than for fish not detected the following spring and summer (P < 0.0001). (7) Fish that migrated through Lower Granite Dam in April and May were significantly larger at release than fish that migrated after May (P < 0.0001) (only 12 fish migrated after May). (8) In 2008, peak detections at Lower Granite Dam of parr tagged during summer 2007 (from the 12 stream populations in Idaho and 4 streams in Oregon) occurred during moderate flows of 87.5 kcfs on 7 May and high flows of 197.3 kcfs on 20 May. The 10th, 50th, and 90th percentile passage occurred on 30 April, 11 May, and 23 May, respectively. (9) In 2007-2008, estimated parr-to-smolt survival to Lower Granite Dam for Idaho and Oregon streams (combined) averaged 19.4% (range 6.2-38.4% depending on stream of origin). In Idaho streams the estimated parr-to-smolt survival averaged 21.0%. This survival was the second highest since 1993 for Idaho streams. Relative parr densities were lower in 2007 (2.4 parr/100 m{sup 2}) than in all previous years since 2000. In 2008, we observed low-to-moderate flows prior to mid-May and relatively cold weather conditions throughout the spring migration season. These conditions moved half of the fish through Lower Granite Dam prior to mid-May; then high flows moved 50 to 90% of the fish through the dam in only 12 days. Clearly, complex interrelationships of several factors drive the annual migrational timing of the stocks.

13 HYDRO ENERGY↗

A Raman cell based on hollow core photonic crystal fiber for human breath analysis

Purpose: Breath analysis has a potential prospect to benefit the medical field based on its perceived advantages to become a point-of-care, easy to use, and cost-effective technology. Early studies done by mass spectrometry show that volatile organic compounds from human breath can represent certain disease states of our bodies, such as lung cancer, and revealed the potential of breath analysis. But mass spectrometry is costly and has slow-turnaround time. The authors’ goal is to develop a more portable and cost effective device based on Raman spectroscopy and hollow core-photonic crystal fiber (HC-PCF) for breath analysis. Methods: Raman scattering is a photon-molecular interaction based on the kinetic modes of an analyte which offers unique fingerprint type signals that allow molecular identification. HC-PCF is a novel light guide which allows light to be confined in a hollow core and it can be filled with a gaseous sample. Raman signals generated by the gaseous sample (i.e., human breath) can be guided and collected effectively for spectral analysis. Results: A Raman-cell based on HC-PCF in the near infrared wavelength range was developed and tested in a single pass forward-scattering mode for different gaseous samples. Raman spectra were obtained successfully from reference gases (hydrogen, oxygen, carbon dioxide gases), ambient air, and a human breath sample. The calculated minimum detectable concentration of this system was ∼15 parts per million by volume, determined by measuring the carbon dioxide concentration in ambient air via the characteristic Raman peaks at 1286 and 1388 cm{sup −1}. Conclusions: The results of this study were compared to a previous study using HC-PCF to trap industrial gases and backward-scatter 514.5 nm light from them. The authors found that the method presented in this paper has an advantage to enhance the signal-to-noise ratio (SNR). This SNR advantage, coupled with the better transmission of HC-PCF in the near-IR than in the visible wavelengths led to an estimated seven times improvement in the detection sensitivity. The authors’ prototype device also demonstrated a 100-fold improvement over a recently reported detection limit of a reflective capillary fiber-based Raman cell for breath analysis. Continued development is underway to increase the detection sensitivity further to reach practical clinical applications.

60 APPLIED LIFE SCIENCES↗

Consistent satellite XCO 2 retrievals from SCIAMACHY and GOSAT using the BESD algorithm

Consistent and accurate long-term data sets of global atmospheric concentrations of carbon dioxide (CO 2 ) are required for carbon cycle and climate related research. However, global data sets based on satellite observations may suffer from inconsistencies originating from the use of products derived from different satellites as needed to cover a long enough time period. One reason for inconsistencies can be the use of different retrieval algorithms. We address this potential issue by applying the same algorithm, the Bremen Optimal Estimation DOAS (BESD) algorithm, to different satellite instruments, SCIAMACHY on-board ENVISAT (March 2002–April 2012) and TANSO-FTS on-board GOSAT (launched in January 2009), to retrieve XCO 2 , the column-averaged dry-air mole fraction of CO 2 . BESD has been initially developed for SCIAMACHY XCO 2 retrievals. Here, we present the first detailed assessment of the new GOSAT BESD XCO 2 product. GOSAT BESD XCO 2 is a product generated and delivered to the MACC project for assimilation into ECMWF's Integrated Forecasting System (IFS). We describe the modifications of the BESD algorithm needed in order to retrieve XCO 2 from GOSAT and present detailed comparisons with ground-based observations of XCO 2 from the Total Carbon Column Observing Network (TCCON). We discuss detailed comparison results between all three XCO 2 data sets (SCIAMACHY, GOSAT and TCCON). The comparison results demonstrate the good consistency between the SCIAMACHY and the GOSAT XCO 2 . For example, we found a mean difference for daily averages of &minus;0.60 ± 1.56 ppm (mean difference ± standard deviation) for GOSAT-SCIAMACHY (linear correlation coefficient r = 0.82), &minus;0.34 ± 1.37 ppm ( r = 0.86) for GOSAT-TCCON and 0.10 ± 1.79 ppm ( r = 0.75) for SCIAMACHY-TCCON. The remaining differences between GOSAT and SCIAMACHY are likely due to non-perfect collocation (±2 h, 10° &times; 10° around TCCON sites), i.e., the observed air masses are not exactly identical, but likely also due to a still non-perfect BESD retrieval algorithm, which will be continuously improved in the future. Our overarching goal is to generate a satellite-derived XCO 2 data set appropriate for climate and carbon cycle research covering the longest possible time period. We therefore also plan to extend the existing SCIAMACHY and GOSAT data set discussed here by using also data from other missions (e.g., OCO-2, GOSAT-2, CarbonSat) in the future.

54 ENVIRONMENTAL SCIENCES↗

A non-radial oscillation mode in an accreting millisecond pulsar?

We present results of targeted searches for signatures of non-radial oscillation modes (such as r- and g-modes) in neutron stars using RXTE data from several accreting millisecond X-ray pulsars (AMXPs). We search for potentially coherent signals in the neutron star rest frame by first removing the phase delays associated with the star's binary motion and computing fast Fourier transform power spectra of continuous light curves with up to 2{sup 30} time bins. We search a range of frequencies in which both r- and g-modes are theoretically expected to reside. Using data from the discovery outburst of the 435 Hz pulsar XTE J1751–305 we find a single candidate, coherent oscillation with a frequency of 0.5727597 × ν{sub spin} = 249.332609 Hz, and a fractional Fourier amplitude of 7.46 × 10{sup –4}. We estimate the significance of this feature at the 1.6 × 10{sup –3} level, slightly better than a 3σ detection. Based on the observed frequency we argue that possible mode identifications include rotationally modified g-modes associated with either a helium-rich surface layer or a density discontinuity due to electron captures on hydrogen in the accreted ocean. In the latter case the presence of sufficient hydrogen in this ultracompact system with a likely helium-rich donor would present an interesting puzzle. Alternatively, the frequency could be identified with that of an inertial mode or a core r-mode modified by the presence of a solid crust; however, the r-mode amplitude required to account for the observed modulation amplitude would induce a large spin-down rate inconsistent with the observed pulse timing measurements. For the AMXPs XTE J1814–338 and NGC 6440 X–2 we do not find any candidate oscillation signals, and we place upper limits on the fractional Fourier amplitude of any coherent oscillations in our frequency search range of 7.8 × 10{sup –4} and 5.6 × 10{sup –3}, respectively. We briefly discuss the prospects and sensitivity for similar searches with future, larger X-ray collecting area missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Historic American engineering record. Nevada national security site, Bren Tower Complex. Written historical and descriptive data and field records

The BREN (Bare Reactor Experiment, Nevada) Tower Complex is significant for its role in the history of nuclear testing, radiation dosimetry studies, and early field testing of the Strategic Missile Defense System designs. At the time it was built in 1962, the 1,527 ft (465 m) BREN Tower was the tallest structure west of the Mississippi River and exceeded the height of the Empire State Building by 55 ft (17 m). It remains the tallest ever erected specifically for scientific purposes and was designed and built to facilitate the experimental dosimetry studies necessary for the development of accurate radiation dose rates for the survivors of Hiroshima and Nagasaki. The tower was a key component of the Atomic Bomb Casualty Commission’s (ABCC) mission to predict the health effects of radiation exposure. Moved to its current location in 1966, the crucial dosimetry studies continued with Operation HENRE (High Energy Neutron Reactions Experiment). These experiments and the data they generated became the basis for a dosimetry system called the Tentative 1965 Dose or more commonly the T65D model. Used to estimate radiation doses received by individuals, the T65D model was applied until the mid-1980s when it was replaced by a new dosimetry system known as DS86 based on the Monte Carlo method of dose rate calculation. However, the BREN Tower data are still used for verification of the validity of the DS86 model. In addition to its importance in radiation heath effects research, the BREN Tower Complex is also significant for its role in the Brilliant Pebbles research project, a major component of the Strategic Defense Initiative popularly known as the “Star Wars” Initiative. Instigated under the Reagan Administration, the program’s purpose was to develop a system to shield the United States and allies from a ballistic missile attack. The centerpiece of the Strategic Defense System was space-based, kinetic-kill vehicles. In 1991, BREN Tower was used for the tether tests of the Brilliant Pebbles prototype vehicle at the earth’s surface prior to the more costly space testing program. The success of these tests established the Brilliant Pebbles program as an essential component of America’s space-based missile defense system even after the dismantling of the Soviet Union. Data from the Brilliant Pebbles research program continues to inspire current missile defense system research (Independent Working Group 2009).

54 ENVIRONMENTAL SCIENCES↗

THE EFFECT OF 3HE ON LOW PRESSURE HYDRIDE ABSORPTION MEASUREMENTS WITH TRITIUM

Absorption isotherm data exists for a wide variety of hydrogen-metal systems. When working with high purity gases, appropriately sized equipment, and hydrides with equilibrium pressures above several hundred Pa, data collection is relatively straightforward. Special consideration must be given to experiments involving low equilibrium pressure hydrides, as even sub-ppm levels of gas impurities can generate partial pressures many times greater than the equilibrium pressures to be measured. Tritium absorption experiments are further complicated by the continuous generation of helium-3. The time required to transfer and absorb a known quantity of tritium onto a sample ultimately limits the minimum pressure range that can be studied using the standard technique. Equations are presented which show the pressure of helium-3 in a sample cell based on the amount of tritium to be absorbed, the sample cell volume and temperature, and the decay time of tritium. Sample calculations for zirconium show that at 300 C, the estimated helium-3 pressure in the cell will be equal to the hydrogen absorption pressure after only milliseconds of tritium decay. An alternate method is presented that permits the collection of equilibrium data at pressures orders of magnitude lower than possible using a direct approach.

08 HYDROGEN↗

A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE RADIO LIGHT CURVE OF THE GAMMA-RAY NOVA IN V407 CYG: THERMAL EMISSION FROM THE IONIZED SYMBIOTIC ENVELOPE, DEVOURED FROM WITHIN BY THE NOVA BLAST

We present multi-frequency radio observations of the 2010 nova event in the symbiotic binary V407 Cygni, obtained with the Karl G. Jansky Very Large Array (VLA) and spanning 1-45 GHz and 17-770 days following discovery. This nova-the first ever detected in gamma rays-shows a radio light curve dominated by the wind of the Mira giant companion, rather than the nova ejecta themselves. The radio luminosity grew as the wind became increasingly ionized by the nova outburst, and faded as the wind was violently heated from within by the nova shock. This study marks the first time that this physical mechanism has been shown to dominate the radio light curve of an astrophysical transient. We do not observe a thermal signature from the nova ejecta or synchrotron emission from the shock, due to the fact that these components were hidden behind the absorbing screen of the Mira wind. We estimate a mass-loss rate for the Mira wind of M-dot{sub w} approx. 10{sup -6} M{sub Sun} yr{sup -1}. We also present the only radio detection of V407 Cyg before the 2010 nova, gleaned from unpublished 1993 archival VLA data, which shows that the radio luminosity of the Mira wind varies by a factor of {approx}>20 even in quiescence. Although V407 Cyg likely hosts a massive accreting white dwarf, making it a candidate progenitor system for a Type Ia supernova, the dense and radially continuous circumbinary material surrounding V407 Cyg is inconsistent with observational constraints on the environments of most Type Ia supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LONG-TERM OPTICAL STUDIES OF THE BE/X-RAY BINARY RX J0440.9+4431/LS V+44 17

We present the spectroscopic and photometric observations on the Be/X-ray binary RX J0440.9+4431 from 2001 to 2014. The short-term and long-term variability of the Hα line profile indicates that one-armed global oscillations existed in the circumstellar disk. Several positive and negative correlations between the V-band brightness and the Hα intensity were found from the long-term photometric and spectroscopic observations. We suggest that the monotonic increase of the V-band brightness and the Hα brightness between our 2005 and 2007 observations might be the result of a continuous mass ejection from the central Be star, while the negative correlation in 2007–2010 should be caused by the cessation of mass loss from the Be star just before the decline in V-band brightness began (around our 2007 observations). With the extension of the ejection material, the largest circumstellar disk during the last two decades has been observed in our 2010 observations with an equivalent width of approximately −12.88 Å, which corresponds to a circumstellar disk with a size of 12.9 times the radius of the central Be star. Three consecutive X-ray outbursts peaking around MJD 55293, 55444, and 55591 might be connected with the largest circumstellar disk around the Be star. We also use the orbital motion of the neutron star as a probe to constrain the structure of the circumstellar disk and estimate the eccentricity of the binary system to be ≥0.4. After three years of the Hα intensity decline after the X-ray outbursts, a new circumstellar disk was being formed around the Be star after our 2013 observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Update on Parallel Process Execution in the Next Generation System Analysis Model (NGSAM)

As of the end of 2022, it is estimated that over 90,000 metric tons of heavy metal (MTHM) of spent nuclear fuel (SNF) were stored at various commercial nuclear power reactor sites (both operating and shutdown) across the United States [1]. The Office of Storage and Transportation within the U.S. Department of Energy’s Office of Nuclear Energy is planning for the transportation, storage, and eventual disposal of SNF and high-level radioactive waste (HLW). To aid in this effort and inform decision-makers about the backend of the spent fuel cycle, systems analysis tools capable of analyzing the various options with respect to SNF and HLW management are being used as well as continuously improved to meet the evolving needs of the program. System analysts typically use these tools to vary underlying assumptions (shipping rates, available facilities, start dates, interim storage capacity, etc.) and study the associated system implications such as timing for clearing sites of SNF, various cost elements, transportation infrastructure acquisition needs, etc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid lithium applications for solving challenging fusion reactor issues and NSTX-U contributions

Steady-state fusion reactor operation presents major divertor technology challenges, including high divertor heat flux both steady-state and transients. In addition to those issues, there are unresolved issues of long term dust accumulation and associated tritium inventory and safety issues. It has been suggested that radiative liquid lithium divertor concepts with a modest lithium-loop could provide a possible solution for these outstanding fusion reactor technology issues while potentially improving the reactor plasma performance. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peak heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid lithium divertor (RLLD) concept and its variant, the active liquid lithium divertor concept (ARLLD), taking advantage of the enhanced Li radiation in relatively poorly confined divertor plasmas. It was estimated that only a few moles/sec of lithium injection would be needed to significantly reduce the divertor heat flux in a tokamak fusion power plant. By operating at lower temperatures ≤ 500°C than the first wall ~ 600 – 700°C, the LL-covered divertor chamber wall surfaces can serve as an effective particle pump, as impurities generally migrate toward lower temperature LL divertor surfaces. To maintain the LL purity, a closed LL loop system with a modest circulating capacity of ~ 1 liter/second (l/sec) is envisioned to sustain the steady-state operation of a 1 GW-electric class fusion power plant. By running the Li loop continuously, it can carry the dust particles and impurities generated in the vacuum vessel to outside where the dust / impurities are removed by relatively simple filter and cold/hot trap systems. Using a cold trap system, it can recover in tritium (T) in real time from LL at a rate of ~ 0.5 g / sec needed to sustain the fusion reaction while minimizing the T inventory issue. With an expected T fraction of ≤ 0.7 %, an acceptable level of T inventory can be achieved. In NSTX-U, preparations are now underway to elucidate the physics of Li plasma interactions with a number of Li application tools and Li radiation spectroscopic instruments. The NSTX-U Li evaporator which provides Li coating over the lower divertor plate, can offer important information on the RLLD concept, and the Li granule injector will test some of the key physics issue on the ARLLD concept. A LL-loop is also being prepared off line for prototyping future use on NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inference of Rock Flow and Mechanical Properties from Injection-Induced Microseismic Events During Geologic CO 2 Storage

Monitoring microseismic activities during CO 2 injection into geologic formations is important for ensuring the safety of the storage operations. The resulting data provide insight into the response of the storage formation to CO 2 injection and can be used to infer the underlying rock flow and mechanical properties. In this paper, assimilation of microseismic data is performed for dynamic characterization of the storage formation by using a stochastic simulation model to forecast the microseismic response of a geologic formation during CO 2 injection. Two modeling approaches are adopted to predict the space-time distribution of the injection-induced microseismicity. The first model is based on pore pressure relaxation assumption, while the second model uses coupled flow and geomechanics simulation to establish the complex physical relation between the storage formation properties and the corresponding microseismic responses during CO 2 injection. The stochastic predictive models in each case are used in ensemble data assimilation frameworks to estimate rock properties from the observed microseismic data. Two data assimilation methods are considered: (i) a new ensemble-based stochastic point process filter (EnPPF) that can directly integrate discrete microseismic events, and (ii) a variant of ensemble smoother, known as the ensemble smoother with multiple data assimilation (ES-MDA), which requires continuous representation of microseismic events for assimilation. The two methods are successfully applied to a geologically realistic model of the Farnsworth Field in Texas, with complex geologic flow units and interacting fault systems.

42 ENGINEERING↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

Data-driven Alignment of the Tracker for the Mu2e Experiment

An alignment of the Mu2e Tracker is investigated using the Mu2e Offline Software and Millepede-II. Simulated misalignments of Tracker planes were inserted between Monte-Carlo event generation and before reconstruction using randomly generated $(x,y,z)$-translations and rotations of the rigid-body planes in the detector model. Cosmic ray muons, with no magnetic field present in the Detector Solenoid, will follow a straight-line trajectory. A maximum-likelihood fit is used to reconstruct a track and determine its parameters. Tracks traversing at least four planes, with ten registered straw hits, and a maximum time residual of $20$ ns are selected to be used in an alignment sample. The cuts were chosen to discard tracks with low information content, such as those with high levels of multiple scattering or those with low numbers of measurements contributing to a single track fit. Millepede-II produces the resulting alignment constants according to a simultaneous least-squares fit of the alignment parameters and the track parameters for all input tracks. The improved alignment constants are used to repeat the process and recover an increased number of suitable tracks, further improving the estimate of the alignment constants in subsequent iterations. A performance study of the process was conducted on a misaligned Tracker in the case of translation-only, and translation plus rotational misalignments. In both cases, the correct alignment constants were recovered to within statistical error after three global fit iterations. Additionally, a continuous integration system was developed for the \texttt{Mu2e/Offline} GitHub repository, introducing a convenient automated testing process for all proposed changes (``pull requests"). The tests developed included a full build of the software, followed by tests of the validation routines, geometry overlap checking, and multi-threading mode. Additionally, code quality checks and low-statistics physics comparison checks a re also available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-P-30: Clinical Assessment of Auto Beam-Hold Triggered by Fiducial Localization During Prostate RapidArc Delivery

Purpose: To assess the clinical efficacy of auto beam hold during prostate RapidArc delivery, triggered by fiducial localization on kV imaging with a Varian True Beam. Methods: Prostate patients with four gold fiducials were candidates in this study. Daily setup was accomplished by aligning to fiducials using orthogonal kV imaging. During RapidArc delivery, a kV image was automatically acquired with a momentary beam hold every 60 degrees of gantry rotation. The position of each fiducial was identified by a search algorithm and compared to a predetermined 1.4 cm diameter target area. Treatment continued if all the fiducials were within the target area. If any fiducial was outside the target area the beam hold was not released, and the operators determined if the patient needed re-alignment using the daily setup method. Results: Four patients were initially selected. For three patients, the auto beam hold performed seamlessly. In one instance, the system correctly identified misaligned fiducials, stopped treatment, and the patient was re-positioned. The fourth patient had a prosthetic hip which sometimes blocked the fiducials and caused the fiducial search algorithm to fail. The auto beam hold was disabled for this patient and the therapists manually monitored the fiducial positions during treatment. Average delivery time for a 2-arc fraction was increased by 59 seconds. Phantom studies indicated the dose discrepancy related to multiple beam holds is <0.1%. For a plan with 43 fractions, the additional imaging increased dose by an estimated 68 cGy. Conclusion: Automated intrafraction kV imaging can effectively perform auto beam holds due to patient movement, with the exception of prosthetic hip patients. The additional imaging dose and delivery time are clinically acceptable. It may be a cost-effective alternative to Calypso in RapidArc prostate patient delivery. Further study is warranted to explore its feasibility under various clinical conditions.

60 APPLIED LIFE SCIENCES↗