Search NASA⌕ Search

SEARCH · Search NASA

Results for “control algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Reinstated JET ICRF ILA: Overview and Results

The works undertaken to reinstate the JET ICRF ILA are reviewed. The vacuum matching capacitors were replaced, an extensive calibration of all the measurements in the RF circuit was carried out, new simulation tools were created and new control algorithms were implemented for the – toroidal and poloidal – phase control of the array as well as for the matching of the second stage. A review of the contribution of the reinstated ILA to the JET programme during the last campaigns is given showing namely that the new controls allowed extending the range of the operation to lower (29MHz) and higher (51MHz) frequencies than previously achieved and allowed more flexible and reliable operation. Operation with coupled power levels up to 2.8MW and voltages up to 40kV was achieved. ILA results on plasma are discussed and emphasis is given to the features of interest for ITER.

Dumortier, Pierre↗

Predictive Control of Residential Heat Pump Water Heaters [SWR-13-35]

Heat pump water heaters (HPWH) in the United States typically feature both a heat pump and at least one electric resistance element for heating. The heat pump is much more efficient than the element but cannot heat the water as quickly. The combination of these two heat sources makes HPWH a perfect candidate for implementing advanced control algorithms to achieve additional energy savings. NREL's Predictive Control of Residential Heat Pump Water Heaters introduces a novel predictive control method that provides optimal setpoint profile for both heat sources based on the patterns discovered from users' hot water use data. A simulation study indicates the Predictive Control of Residential Heat Pump Water Heaters is able to achieve significant energy savings without impacting users' thermal comfort.

Christensen, Dane↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Active disturbance rejection controller for chemical reactor

In the petrochemical industry, the synthesis of 2 ethyl-hexanol-oxo-alcohols (plasticizers alcohol) is of high importance, being achieved through hydrogenation of 2 ethyl-hexenal inside catalytic trickle bed three-phase reactors. For this type of processes the use of advanced control strategies is suitable due to their nonlinear behavior and extreme sensitivity to load changes and other disturbances. Due to the complexity of the mathematical model an approach was to use a simple linear model of the process in combination with an advanced control algorithm which takes into account the model uncertainties, the disturbances and command signal limitations like robust control. However the resulting controller is complex, involving cost effective hardware. This paper proposes a simple integer-order control scheme using a linear model of the process, based on active disturbance rejection method. By treating the model dynamics as a common disturbance and actively rejecting it, active disturbance rejection control (ADRC) can achieve the desired response. Simulation results are provided to demonstrate the effectiveness of the proposed method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A digital control system for external magnetohydrodynamic modes in tokamak plasmas

A feedback system for controlling external, long-wavelength magnetohydrodynamic activity is described. The system is comprised of a network of localized magnetic pickup and control coils driven by four independent, low-latency field-programable gate array controllers. The control algorithm incorporates digital spatial filtering to resolve low mode number activity, temporal filtering to correct for frequency-dependent amplitude and phase transfer effects in the control hardware, and a Kalman filter to distinguish the unstable plasma mode from noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing and Testing Contols to Mitigate Dynamic Loads in the Controls Advanced Research Turbine: Preprint

The National Renewable Energy Laboratory is designing, implementing, and testing advanced controls to maximize energy extraction and reduce structural dynamic loads of wind turbines. These control designs are based on a linear model of the turbine that is generated by specialized modeling software. In this paper, we show the design and simulation testing of a control algorithm to mitigate blade, tower, and drivetrain loads using advanced state-space control design methods.

17 WIND ENERGY↗

A CPS Based Optimal Operational Control System for Fused Magnesium Furnace

Fused magnesia smelting for fused magnesium furnace (FMF) is an energy intensive process with high temperature and comprehensive complexities. Its operational index namely energy consumption per ton (ECPT) is defined as the consumed electrical energy per ton of acceptable quality and is difficult to measure online. Moreover, the dynamics of ECPT cannot be precisely modelled mathematically. The model parameters of the three-phase currents of the electrodes such as the molten pool level, its variation rate and resistance are uncertain and nonlinear functions of the changes in both the smelting process and the raw materials composition. In this paper, an integrated optimal operational control algorithm proposed is composed of a current set-point control, a current switching control and a self-optimized tuning mechanism. The tight conjoining of and coordination between the computational resources including the integrated optimal operational control, embedded software, industrial cloud, wireless communication and the physical resources of FMF constitutes a cyber-physical system (CPS) based embedded optimal operational control system. Successful application of this system has been made for a production line with ten fused magnesium furnaces in a factory in China, leading to a significant reduced ECPT.

Cyber-Physical Systems↗

An integrated approach to piezoactuator positioning in high-speed atomic force microscope imaging

In this paper, an integrated approach to achieve high-speed atomic force microscope (AFM) imaging of large-size samples is proposed, which combines the enhanced inversion-based iterative control technique to drive the piezotube actuator control for lateral x-y axis positioning with the use of a dual-stage piezoactuator for vertical z-axis positioning. High-speed, large-size AFM imaging is challenging because in high-speed lateral scanning of the AFM imaging at large size, large positioning error of the AFM probe relative to the sample can be generated due to the adverse effects--the nonlinear hysteresis and the vibrational dynamics of the piezotube actuator. In addition, vertical precision positioning of the AFM probe is even more challenging (than the lateral scanning) because the desired trajectory (i.e., the sample topography profile) is unknown in general, and the probe positioning is also effected by and sensitive to the probe-sample interaction. The main contribution of this article is the development of an integrated approach that combines advanced control algorithm with an advanced hardware platform. The proposed approach is demonstrated in experiments by imaging a large-size (50 {mu}m) calibration sample at high-speed (50 Hz scan rate)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the Electrical Properties of the ITER ICRF Antenna using Reduced-Scale Mock-Ups

Experimental measurements on reduced-scale mock-ups allow validating the electrical properties and RF numerical optimization of the ITER ICRF antenna. Frequency response in the different regions of the antenna is described and key parameters for performance improvement are given. Coupling is improved by acting on the front-face geometry (strap width, antenna box depth and vertical septa recess). The 4-port junction acts as a frequency filter and together with the service stub performs pre-matching in the whole frequency band. Influence of the Faraday screen on coupling is limited. The effect of voltage limitation on the maximum total radiated power is given. The importance of a good decoupling network and of grounding is emphasized. Finally the control of the antenna wave spectrum is performed by implementing feedback controlled load-resilient matching and decoupling options and control algorithms are tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Demonstrating autonomous controls on hardware test beds is a necessity for successful missions to Mars and beyond

NASA and the Department of Defense are planning for a mission to Mars in the 2030s–2040s using nuclear thermal propulsion (NTP). NTP uses a nuclear reactor to heat flowing hydrogen and create thrust. A serious concern for crewed and uncrewed missions to Mars is the loss of reactor control. The reactor startup and initial rocket impulse are initiated in cislunar or near-earth orbital regions; therefore, radio communications between ground control and the NTP engine should occur in real time. However, radio communications can take more than 20 min, depending on planet positions, to reach Mars orbiters from ground control. To address this delay, local autonomous controls are implemented onboard the NTP engine to ensure acceptable operation. However, autonomous controls have not been demonstrated or implemented in research or power reactor contexts because of safety and reliability concerns. To enable autonomous controls development, demonstration, and validation, Oak Ridge National Laboratory has created a nonnuclear hardware-in-the-loop test bed. Sensors throughout the test bed relay system status and hardware response to the user control algorithm, including measurements of temperature, flow, pressure of a loop, control drum position, and drum speed. This paper discusses the development of this facility and user accessibility.

33 ADVANCED PROPULSION SYSTEMS↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm: Preprint

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighboring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchain↗

Wave forecast and its application to the optimal control of offshore floating wind turbine for load mitigation

Control algorithms play an important role in energy capture and load mitigation for offshore floating wind turbines (OFWTs). One of the advanced and effective control techniques is the feedforward or model predictive control approach, which requires the forecast of incoming environment conditions. For OFWTs, wave loading is one of the dominant sources to excite structural responses. This study is thus motivated to develop forecasting algorithms for wave elevations and wave excitation forces with the purpose of applying feedforward controllers on OFWTs. Two forecasting algorithms, the approximate Prony Method based on ESPRIT (Estimation of Signal Parameters via Rotational Invariance Techniques) and SVM (Support Vector Machine) regression, are developed and validated using wave records from tank tests. Utilizing the forecasted wave elevations and wave excitation forces, a feedforward LQR controller is designed to mitigate structural loads of an OFWT system.

17 WIND ENERGY↗

Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗