Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Method to Investigate Cognitive Aging Effects in Nuclear Operations Using the Rancor Microworld Simulator

Many nuclear power plant (NPP) operators are close to, or at retirement age. Since NPP operators are responsible for tasks that engage different and complex cognitive abilities, human factors researchers recently called for the need to examine cognitive aging effects and potential interactions with modernized control rooms. One way control rooms are being modernized is by replacing paper-based procedures with computer-based procedures (CBPs). This paper outlines a method for testing preference and usability of three types of CBPs as a function of age, in simulated NPP operations. The Rancor Microworld Simulator will be used, which mimics an NPP control room, allowing novices to learn to perform operator tasks quickly. The experiment will have two independent variables: age (young and old) and CBP-type (Type 1, Type 2, and Type 3). The three types of CBPs vary in levels of embedded instrumentation and controls. Adults aged 18–25 years (young group) and =60 years (older group) will be recruited from the general population. The dependent variables will be preference and usability metrics via survey and simulator logs. All participants will perform two scenario types (startup and loss of feedwater operations) and will be randomly assigned to one type of CBP to guide them through the scenario. Analyses of variance (ANOVAs) will be used to determine whether there is a main effect of age and any age x CBP-type interactions on the preference and usability dependent variables.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Engineering Scale Drying of Aluminum-Clad Spent Nuclear Fuel: Experiment Report

Engineering-scale tests were performed to evaluate the relative effectiveness of forced gas and vacuum-drying processes on aluminum-clad spent nuclear fuel (ASNF) in preparation for extended dry storage. Drying models were developed to improve confidence in the likely range of conditions at the start of dry storage and to understand the factors most significant to each process. Testing was performed at the Holtec International Forced Helium Dehydration training facility in Camden, New Jersey, by students from the University of South Carolina in collaboration with Idaho National Laboratory. A full-size Type 1a basket, with a full-diameter vessel configuration (based on the Department of Energy standardized canister design), was used in combination with a 10 assembly surrogate ASNF arrangement to provide a proxy for geometry. A resistance heater incorporated in one assembly simulated the influence of 100 W decay heat. This instrumented chamber allowed testing of the removal of bulk water, physisorbed water, and chemisorbed water over a range of operating parameters with either drying process. Thick oxide films were grown on aluminum test plates to mimic the ASNF surface chemistry. These one-use test plates were housed within select assemblies during drying. Post-test analysis of these plates gave a measure of the moisture removed during each test, which was compared to a control. Instrumentation provided detailed thermal, humidity, and gas or pressure data relevant to each test. Model simulations generally compared favorably to instrument data for the tests. While both processes were able to remove bulk water, removal of chemisorbed water was shown to depend heavily on local temperature. To the disadvantage of vacuum drying, operations approaching or exceeding 220°C achieved consistently more dehydroxylation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of an advanced energy management system for microgrid control using a state machine

A state machine is proposed as the solution for an automated microgrid energy management system (EMS) to improve transient performance during transition operations. It characterizes microgrid operation by seven states that cover all the operating modes: two for steady-state operation (grid-connected and islanded), four for transition operation (preparing for disconnection, transitioning to islanding, preparing for reconnection, and transitioning to grid-connected), and one for emergency operation (black-start operation). A unique dispatch algorithm is developed for each state to achieve the control objective, and the transition function is implemented in the state machine as control logics to transition the system from one state to the next. The feasibility and effectiveness of the developed state machine is validated by simulation in MATLAB with an example microgrid, and the test results show excellent performance of the state machine to achieve the target control objective in each state and to improve the system's transient performance during transition operation.

36 MATERIALS SCIENCE↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

The EGS Collab Project – Stimulations at Two Depths

The EGS Collab project, supported by the US Department of Energy, is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory to address challenges in implementing enhanced geothermal systems (EGS). Data and observations from the field tests are compared to simulations to understand processes and build confidence in numerical modeling of the processes. We have completed Experiment 1 (of 3), which examined hydraulic fracturing in a well-characterized underground fractured phyllite test bed at a depth of approximately 1.5 km at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. Testbed characterization included fracture mapping, borehole acoustic and optical televiewers, full waveform sonic, conductivity, resistivity, temperature, campaign p- and s-wave investigations and electrical resistance tomography. Borehole geophysical techniques including passive seismic, continuous active source seismic monitoring, electrical resistance tomography, fiber-based distributed strain, distributed temperature, and distributed acoustic monitoring, were used to carefully monitor stimulation events and flow tests. More than a dozen stimulations and nearly one year of flow tests were performed. Quality data and detailed observations were collected and analyzed during stimulation and water flow tests using ambient temperature and chilled water. We achieved adaptive control of the tests using real-time monitoring and rapid dissemination of data and near-real-time simulation. More detailed numerical simulation was performed to answer key experimental design questions, forecast fracture propagation trajectories and extents, and analyze and evaluate results. Data are freely available from the Geothermal Data Repository. Experiment 2 examines the potential for hydraulic shearing in amphibolite at a depth of about 1.25 km at SURF. This site has a different set of stress and fracture conditions than Experiment 1. The Experiment 2 testbed consists of nine subhorizontal boreholes configured in two fans of two boreholes which surround the testbed and contain grouted-in electrical resistance tomography, seismic sensors, active seismic sources and distributed fiber sensors. A “five-spot” set of test wells that extends from a custom mined alcove includes an injection well and four production/monitoring wells. The testbed was characterized geophysically and hydrologically, and three stimulations have been performed using the Step-Rate Injection Method for Fracture In-Situ Properties (SIMFIP) tool to measure strains, and a new strain quantifying tool (downhole robotic strain analysis tool -DORSA) was deployed in a monitoring hole during stimulation. Real-time data were broadcast during stimulations to allow real-time response to arising issues.

EGS Collab, Enhanced Geothermal Systems, EGS, fiel↗

A High-Fidelity Cyber-Physical Testbed-Based Benchmarking Dataset For Testing Operational Technology Specific Intrusion Detection Systems

Quality datasets serve a critical purpose in cyber security research. Data is needed to understand system behavior and develop security controls to protect critical systems. However, for critical infrastructure operational environments there is a lack of available datasets to study because of the high cost and specialized capabilities necessary to generate them. This paper documents the development of a dataset of high fidelity hardware in the loop laboratory simulated models of electric and natural gas distribution systems with real cyber attack test cases. A deep dive discussion for the experimental setup and controls for generating the data is provided along with observations from using the data in evaluating intrusion detection approaches.

Ashok, Aditya↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

NREL's advanced distribution management system (ADMS) test bed is a vendor-neutral resource for evaluating existing and future ADMS functionalities in a realistic laboratory setting. The test bed uses Opal-RT's ePHASORsim and eMEGAsim products interfaced with an OpenDSS power system simulation through the HELICS cosimulation platform developed by multiple DOE laboratories; and with power and controller hardware. NREL will present an overview of the test bed and the technologies included within it, and also some examples of how the test bed has been used to address industry challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

FATES crown damage simulation outputs 2022

This dataset contains outputs from the Functionally Assembled Terrestrial Ecosystem Simulator (FATES) and accompanies the paper "Needham, J.F., Arellano, A., Davies, S.J., Fisher, R.A., Hammer, V., Knox, R., Mitre, D., Muller-Landau, H.C., Zuleta, D., Koven, C.D. Tree crown damage and its effects on forest carbon cycling in a tropical forest, 2022, Global Change Biology". Data are unprocessed netcdf file outputs from simulations that were run to test the effect of a new crown damage module in FATES. Specifically, this data package contains a sensitivity analysis to the carbon cushion parameter damage_Ccushion_ensemble_e1b5bd9_bf013ef_2021-09-02.h0.ensemble.sofar.nc, a sensitivity analysis to the root nitrogen stoichiometry parameter damage_Nstoich_ensemble_e1b5bd9_bf013ef_2021-09-02.h0.ensemble.sofar.nc, a sensitivity analysis to parameters controlling crown damage and recovery damage_recovery_ensemble_e1b5bd9_354f0b0_2021-09-02.h0.ensemble.sofar.nc, and a sensitivity analysis to the number of crown damage bins elm_fates_bci_*_damagebins.Eac53ccb80b-F8f994c29.2022-04-19.elm.h0.fullrun.nc. This data package also contains a high root nitrogen configuration of FATES, including both a control, and a crown damage simulation high_root_N_control_e1b5bd9_354f0b0_2021-09-02.clm2.h0.fullrun.nc and high_root_N_damage_e1b5bd9_354f0b0_2021-09-02.clm2.h0.fullrun.nc. There is an analogous low root nitrogen configuration of FATES, including a control, low_root_N_control_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc a damage only simulation low_root_N_damageonly_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc, a damage plus mortality simulation low_root_N_damage_mort_e1b5bd9_bf013ef_2021-09-02.clm2.h0.fullrun.nc, and a mortality only simulation low_root_N_mort_only_e1b5bd9_ef845c8_2021-09-02.clm2.h0.fullrun.nc. Finally, there is a two PFT simulation in which we test the effect of recovery on competitive dynamics, low_root_N_damage_two_pfts_stoichastic_e1b5bd9_bf013ef_2021-09-10.clm2.h0.fullrun.nc. These simulations test the effect of representing crown damage in FATES, compared with simulations that have an equivalent increase in mortality. Jupyter notebooks to analyse these files can be found at https://github.com/JessicaNeedham/Needham_etal_GCB_2022_FATES_crown_damage.

54 ENVIRONMENTAL SCIENCES↗

A Review of Tank 48H Treatment of Tetraphenylborate with Permanganate

Tank 48H contains roughly 270,000 gallons of radioactive waste material. The waste stored in this tank was to be processed in multiple stages utilizing facilities at the Savannah River Site (SRS) almost 30 years ago. The In-Tank Precipitation Process (ITP) was initiated in Tank 48H, which precipitated highly radioactive cesium-137 using sodium tetraphenylborate (NaTPB). While the process succeeded in precipitating the Cs, Sr, and other actinides, it also generated an unexpectedly large amount of benzene. The evolved benzene created a safety concern and made the waste incompatible with further downstream processing. This halted the ITP, and a new method of treatment was required to continue processing the legacy waste contained in Tank 48H. A myriad of treatment options have been proposed with multiple teams of researchers assembled to work on this highly complex issue over the last few decades. This review investigated one potentially viable treatment option, in-tank oxidation with sodium permanganate. Permanganate has been well known in literature as a strong oxidizing agent for organic compounds, as well as being utilized at the Savannah River Site (SRS) in other processes. A small number of studies have been conducted utilizing waste simulants to evaluate the use of permanganate as an oxidant for tetraphenylborate (TPB). A search of the literature and data from these studies indicates that permanganate could be a viable treatment for destruction of TPB in Tank 48H. While the scoping studies had a small number of individual experiments and nonideal conditions, the permanganate decomposed up to 90% of the TPB. A free hydroxide concentration above 1.0 M is required for tank corrosion control. Simulant studies indicate no decrease in TPB decomposition by permanganate until pH 14. The simulant studies show an increase in TPB decomposition as the temperature of the solution is increased to 40 °C. The post-reaction analysis of previous simulant tests did not look at all of the organic degradation products. Investigations into what these organic products are and in what quantity will help guide determinations as to whether the downstream processing facilities are able to handle the material that will be generated. Study on the time frame for the reaction between permanganate and TPB should be investigated as the literature reports only extend out to two weeks reaction time. The permanganate treatment conditions indicate no corrosion control concerns and a longer timescale reaction may be needed for in-tank treatment. In addition, further study would be useful to identify a lower boundary condition for the ratio of TPB and oxidant. The simulant tests applied large excesses of permanganate, and this may be unnecessary. The size constraint of the tank means that there will be practical limitations on the amount of sodium permanganate that can be added to the tank. The amount of permanganate should be minimized as much as possible while still ensuring decomposition of the TPB to minimize the amount of manganese dioxide solids generated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimates of Acetonitrile Generation from Scale Melter Testing of LAW Simulants (VSL-19S4573-1, Rev A)

With high nitrate feeds, such as Hanford low activity waste (LAW) feeds, the addition of reductants is necessary in order to control foaming of the molten glass pool in the melter because such foaming can lead to extensive downtime. Sugar, which was used for this purpose at the West Valley Demonstration Project vitrification facility, has been selected as the baseline reductant for the Hanford Waste Treatment and Immobilization Plant (WTP). The amount of sugar required increases with the amount of nitrates present in the feed and decreases with the amount of waste organics present in the feed, which themselves act as reductants. Excessive additions of reductants can be deleterious, leading to over-reduction of the melt and formation of sulfides and molten metals. Consequently, the oxidants and reductants in the feed must be suitably balanced. The basis for achieving this balance was developed by VSL and Atkins for the vitrification of high-sodium-nitrate feeds at Savannah River's M-Area and has been successfully applied to the processing of a wide variety of simulated WTP feeds over many years and was ultimately incorporated into the WTP process control models. The reaction of sugar with nitrates and nitrites in the cold cap controls the redox state of the underlying melt, which prevents foaming, and also significantly decreases the amount of NOx produced. In addition, however, small amount of organics reaction products are formed. Extensive testing at VSL over the past more than 20 years has shown that acetonitrile is the most prevalent such organic species. That testing has also shown that a significant amount of acetonitrile is captured in the liquid scrubbers in the WTP off-gas treatment system and will therefore be present in the secondary liquid effluents. In particular, acetonitrile is prevalent in the submerged bed scrubber (SBS) and wet electrostatic precipitator (WESP) liquid effluents from WTP LAW off-gas treatment. When these liquids are concentrated in the WTP Effluent Management Facility (EMF) evaporator in the direct feed LAW (DFLAW) flow-sheet, VSL testing has shown that the majority of the acetonitrile partitions to the evaporator condensate. Since the evaporator condensate is directed to the Hanford Effluent Treatment Facility (ETF), this creates a potential issue with the ETF waste acceptance criteria. Consequently, there is a need to assess the available test data in order to develop projections of the likely concentrations of acetonitrile in the streams to ETF. The objective of the present report is to provide such an assessment in order to provide input to flow-sheet model projections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

The Savannah River National Laboratory (SRNL) was requested to develop a new antifoam control method for the Defense Waste Processing Facility’s (DWPF) Chemical Process Cell (CPC). SRNL completed testing of both chemical and nonchemical foam controls. The nonchemical foam controls were either ineffective (or worse, created more foam) or impractical (a water spray can control foam, but excessive water is needed). As a result, the focus of this study was on finding a superwetter or commercial antifoam for controlling foam. Thirty potential antifoams were tested as part of this study. A series of tests were developed to help screen out ineffective alternatives including: 1. Spreading testing of superspreaders, 2. Foam column testing with physical simulants, 3. Boiling testing with physical and chemical simulants, 4. Days-only Sludge Receipt and Adjustment Tank (SRAT) process simulations with sludge (containing noble metals and mercury), Precipitate Reactor Feed Tank (PRFT), and Slurry Mix Evaporator Feed Tank (SEFT) simulants in the RC1 Reaction Calorimeter (purchased for antifoam testing), and 5. Around-the-clock SRAT and Slurry Mix Evaporator (SME) process simulations with sludge(containing noble metals and mercury), PRFT, and SEFT simulants in the RC1 Reaction Calorimeter. Evonik Surfynol® MD20, a commercially available defoamer, was relatively effective in controlling foam, while remaining chemically stable in SRAT and SME processing across the pH range of 4 to 13. No degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. In nitric-glycolic acid flowsheet testing, 250 mg/kg Evonik Surfynol® MD20 was needed for foam control compared to 1,625 mg/kg for Antifoam 747, DWPF’s current antifoam. In nitric-formic acid flowsheet testing, 1,125 mg/kg of Evonik Surfynol® MD20 was needed to control foam throughout the SRAT and SME cycles. The commercially available superspreader Momentive™ Y-17112 was even more effective than Evonik Surfynol® MD20 as both a defoamer and an antifoam. Not only was the foam destroyed upon addition but also was less persistent between additions. It was the most effective antifoam in testing using both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. In nitric-glycolic acid flowsheet testing, only 100 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. In nitric-formic acid flowsheet testing, 300 mg/kg Momentive™ Y-17112 was needed to control foam throughout the SRAT and SME cycles. Momentive™ Y-17112 is also resistant to hydrolysis as demonstrated by its chemical stability in SRAT and SME processing across the pH range of 4 to 13 and lack of degradation products in offgas or condensate. Both candidates were effective as potential replacements for Antifoam 747, with Y-17112 demonstrating superior foam control. During nitric-glycolic flowsheet testing 50% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. During nitric-formic flowsheet testing 75% less antifoam was needed when using Momentive™ Y-17112 compared to MD20. Foam remediated with Momentive™ Y-17112 was less persistent throughout testing. In addition, no degradation products were detected in the offgas, in the condensate or in the SRAT and SME products. Based on this testing, Momentive™ Y-17112 is clearly superior to Evonik Surfynol® MD20 and Antifoam 747, especially for the nitric-formic acid flowsheet processing; it is recommended that Momentive™ Y-17112 replace Antifoam 747 in DWPF. An antifoam addition strategy is recommended for both the nitric-glycolic acid flowsheet and the nitric-formic acid flowsheet. Implementation of Momentive™ Y-17112 is expected to decrease SRAT and SME boiling times by up to 50%, eliminate the issues resulting from Antifoam 747 degradation products, and minimize foamovers. To validate the effectiveness of these defoaming agents, SRNL recommends irradiation of a SRAT or SME product simulant containing fresh antifoam. The goal of this testing is to determine whether the irradiation causes decomposition of the antifoam that would make it less effective or produce new species in the offgas or slurry. This testing began in April 2020. An evaluation should be completed to determine the thermolytic hydrogen and methane generation rate in downstream equipment, including the High-Level Waste evaporators.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗

Hardware-in-the-loop grid simulator system and method

A hardware-in-the-loop (HIL) electrical grid simulation system and method that combines a reactive divider with a variable frequency converter to better mimic and control expected and unexpected parameters in an electrical grid. The invention provides grid simulation in a manner to allow improved testing of variable power generators, such as wind turbines, and their operation once interconnected with an electrical grid in multiple countries. The system further comprises an improved variable fault reactance (reactive divider) capable of providing a variable fault reactance power output to control a voltage profile, therein creating an arbitrary recovery voltage. The system further comprises an improved isolation transformer designed to isolate zero-sequence current from either a primary or secondary winding in a transformer or pass the zero-sequence current from a primary to a secondary winding.

17 WIND ENERGY↗