Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic surface distortion and hysteresis of a 50 cm diameter fused silica mirror cooled to 77 K

A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.

Young, Jeffrey A.↗

Liquid Cooled Garments

Astronauts working on the surface of the moon had to wear liquid-cooled garments under their space suits as protection from lunar temperatures which sometimes reach 250 degrees Fahrenheit. In community service projects conducted by NASA's Ames Research Center, the technology developed for astronaut needs has been adapted to portable cooling systems which will permit two youngsters to lead more normal lives.

Source record↗

Data Center Market Report

The data center market is poised to explode in the coming decade due to undeniable drivers such as continued adoption of generative AI, increased data storage needs, and enterprise integration of AI in numerous industries [1] [2] [3]. Scalable power and increased computational capacity are at the forefront of considerations for hyperscalers, the major cloud service providers in this space. Lawrence Livermore National Laboratory is uniquely poised to help with informed decision making for data center market leaders during this phase of explosive expansion. National grid modeling expertise and cutting edge innovations in computer cooling systems place LLNL in an enviable position for creating economic impact in the data center industry by leveraging its expertise in these areas which can help the data center market keep up with growing demand.

97 MATHEMATICS AND COMPUTING↗

NASAs Succeeds in Testing of Advanced Rotating Detonation Rocket Engine for New US Space Flight Capability

June-August 2022, NASA engineers at Marshall Space Flight Center in Huntsville Alabama have successfully fired two regeneratively cooled advanced rotating detonation rocket engines (RDRE’s). The engines have accumulated 17 starts at over 600 seconds of total duration. Multiple firings were achieved of greater than 110 seconds each with detonation modes. A single full throttle test produced over 4000 lbf for 15 seconds with detonation modes. The mean pressure at a single point on the injector face was 620 psia. These tests completed the project’s main objective: demonstrating that additive GRCop-alloy hardware could survive long durations while subjected to the detonative events. 4-5 co-rotating detonations were observed during most tests with a single test showing 2-3 waves. Several other milestones were also achieved including successful demonstration of active throttling with detonation modes, successful ignition without a predetonator, and the use of novel additive manufacturing techniques. The primary collaborator was IN Space, LLC (West Lafayette, IN) through an STMD announcement for collaborative opportunity (ACO). Hot fire testing was conducted at Marshall Space Flight Centers heritage east test area at Test Stand 115 in collaboration with Marshall ET10.

Thomas Teasley↗

Projected Applications of a "Climate in a Box" Computing System at the NASA Short-Term Prediction Research and Transition (SPoRT) Center

The NASA Short-term Prediction Research and Transition (SPoRT) Center focuses on the transition of unique observations and research capabilities to the operational weather community, with a goal of improving short-term forecasts on a regional scale. Advances in research computing have lead to "Climate in a Box" systems, with hardware configurations capable of producing high resolution, near real-time weather forecasts, but with footprints, power, and cooling requirements that are comparable to desktop systems. The SPoRT Center has developed several capabilities for incorporating unique NASA research capabilities and observations with real-time weather forecasts. Planned utilization includes the development of a fully-cycled data assimilation system used to drive 36-48 hour forecasts produced by the NASA Unified version of the Weather Research and Forecasting (WRF) model (NU-WRF). The horsepower provided by the "Climate in a Box" system is expected to facilitate the assimilation of vertical profiles of temperature and moisture provided by the Atmospheric Infrared Sounder (AIRS) aboard the NASA Aqua satellite. In addition, the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard NASA s Aqua and Terra satellites provide high-resolution sea surface temperatures and vegetation characteristics. The development of MODIS normalized difference vegetation index (NVDI) composites for use within the NASA Land Information System (LIS) will assist in the characterization of vegetation, and subsequently the surface albedo and processes related to soil moisture. Through application of satellite simulators, NASA satellite instruments can be used to examine forecast model errors in cloud cover and other characteristics. Through the aforementioned application of the "Climate in a Box" system and NU-WRF capabilities, an end goal is the establishment of a real-time forecast system that fully integrates modeling and analysis capabilities developed within the NASA SPoRT Center, with benefits provided to the operational forecasting community.

Jedlovec, Gary J.↗

MEMS Device Being Developed for Active Cooling and Temperature Control

High-capacity cooling options remain limited for many small-scale applications such as microelectronic components, miniature sensors, and microsystems. A microelectromechanical system (MEMS) is currently under development at the NASA Glenn Research Center to meet this need. It uses a thermodynamic cycle to provide cooling or heating directly to a thermally loaded surface. The device can be used strictly in the cooling mode, or it can be switched between cooling and heating modes in milliseconds for precise temperature control. Fabrication and assembly are accomplished by wet etching and wafer bonding techniques routinely used in the semiconductor processing industry. Benefits of the MEMS cooler include scalability to fractions of a millimeter, modularity for increased capacity and staging to low temperatures, simple interfaces and limited failure modes, and minimal induced vibration.

Moran, Matthew E.↗

Altitude testing of a flight weight, self-cooled, 2D thrust vectoring exhaust nozzle

The Augmented Deflector Exhaust Nozzle (ADEN) was tested in PSL-3 at NASA-Lewis Research Center using an F404 engine. The ADEN is a flight weight Single Expansion Ramp Nozzle with thrust vectoring, an internal cooling system utilizing the available engine fan flow, and a variable area throat controlled by the engine control system. Test conditions included dry and max A/B operation at nozzle pressure ratios from 2.0 to 15.0. High nozzle pressure loading was simulated to verify structural integrity at near maximum design pressure. Nozzle settings covered the full range in throat area and + or - 15 deg deflection angle. Test results demonstrated expected aerodynamic performance, cooling system effectiveness, control system stability, and mechanical integrity.

Wooten, W. H.↗

Hybrid Additive Manufacturing Deposition and Selective Laser Melting Techniques Applied to Copper-Alloy Liquid Rocket Engine Combustion Chambers

Virgin Orbit and the NASA Marshall Space Flight Center have partnered to fabricate a small, multi-metallic, regeneratively cooled thrust chamber by leveraging the strengths of two different types of additive manufacturing: Direct Metal Laser Sintering (DMLS) for the copper alloy liner and blown powder Directed Energy Deposition (DED) for the Inconel structural jacket. The DED is being developed using Virgin Orbit's DMG Mori Seiki hybrid additive/subtractive machining center to further enable unique processing and further cost savings. The materials chosen are preferred for high performance thrust chamber applications, representing a significant advancement from the compromises typically made in the production of metal 3D printed thrust chambers for rocket engines. The 1.2K-lbf thrust article is a 16" tall, 3" diameter design modified for this effort to be regeneratively cooled with water and hot fired using a RP-1/LOX pintle-style development injector from Virgin Orbit's NewtonFour upper stage engine. The thrust chamber was tested at Virgin Orbit's Necker test site in Mojave, California. Results from this test campaign are reported in addition to information characterizing the liner, jacket, and bimetallic diffusion layer materials. This paper will also highlight some of the future bimetallic thrust chamber developments that MSFC and Virgin Orbit will complete under a recently awarded NASA contract.

Zagorski, Kevin↗

Advanced liner-cooling techniques for gas turbine combustors

Component research for advanced small gas turbine engines is currently underway at the NASA Lewis Research Center. As part of this program, a basic reverse-flow combustor geometry was being maintained while different advanced liner wall cooling techniques were investigated. Performance and liner cooling effectiveness of the experimental combustor configuration featuring counter-flow film-cooled panels is presented and compared with two previously reported combustors featuring: splash film-cooled liner walls; and transpiration cooled liner walls (Lamilloy).

Norgren, C. T.↗

Advanced liner-cooling techniques for gas turbine combustors

Component research for advanced small gas turbine engines is currently underway at the NASA Lewis Research Center. As part of this program, a basic reverse-flow combustor geometry was being maintained while different advanced liner wall cooling techniques were investigated. Performance and liner cooling effectiveness of the experimental combustor configuration featuring counter-flow film-cooled panels is presented and compared with two previously reported combustors featuring: splash film-cooled liner walls; and transpiration cooled liner walls (Lamilloy).

Norgren, C. T.↗

Cooled spool piston compressor

A hydraulically powered gas compressor receives low pressure gas and outputs a high pressure gas. The housing of the compressor defines a cylinder with a center chamber having a cross-sectional area less than the cross-sectional area of a left end chamber and a right end chamber, and a spool-type piston assembly is movable within the cylinder and includes a left end closure, a right end closure, and a center body that are in sealing engagement with the respective cylinder walls as the piston reciprocates. First and second annual compression chambers are provided between the piston enclosures and center housing portion of the compressor, thereby minimizing the spacing between the core gas and a cooled surface of the compressor. Restricted flow passageways are provided in the piston closure members and a path is provided in the central body of the piston assembly, such that hydraulic fluid flows through the piston assembly to cool the piston assembly during its operation. The compressor of the present invention may be easily adapted for a particular application, and is capable of generating high gas pressures while maintaining both the compressed gas and the compressor components within acceptable temperature limits.

Morris, Brian G.↗

First experimental confirmation of island SOL geometry effects in a high radiation regime on W7-X

Abstract This work characterizes the detachment behavior and radiation characteristics of the low
iota configuration in the Wendelstein 7-X (W7-X) stellarator. The island scrape-off layer (SOL) of the
low iota has a poloidal mode number of 6 islands surrounding the last closed flux surface (LCFS).
The island geometry of the low iota configuration is significantly different to that of the standard
magnetic field configuration, whose detachment characteristics have already been described in previous
work[2, 3, 4]. Experimental results show that the radiation pattern in the low iota configuration
is starkly different to that of the standard magnetic field configuration, with radiation concentrated
at the island SOL O-points, rather than the X-points. Additionally, this O-point localized radiation
pattern is associated with unstable detachment, with both radiation oscillations in experiments and the
lack of a self-consistent plasma solution at high radiated power fraction in EMC3-Eirene simulations.
EMC3-Eirene simulations are used to understand the radiation distribution. It was found that the O-
point localized radiation arises first from local impurity accumulation near the parallel flow stagnation,
which is located close to the geometrical center of the island (”O-point”). The local cooling in this
region leads to plasma condensation in the islands in closest magnetic connection to the divertor target
plates. The heat source to this region of the island, which is thermally isolated from the upstream heat
source in terms of parallel transport, must arise via perpendicular heat transport. This heat source is
expected to be large for the low iota configuration due to its very small internal island field line pitch.
This work highlights the importance (complementary to previous work, e. g. [5, 6]) of the internal
island field line pitch not only on the radiation pattern, but also the detachment performance of the
island divertor.

Winters, Victoria (ORCID:0000000181087774)↗

Design Study of a Superconducting Quadrupole Magnet System Sustainable Under Dark Current Heating in ILC Main Linac

The International Linear Collider (ILC) main linac comprises a series of 12 m-long cryomodules. The cryomodule contains eight 9-cell superconducting (SC) RF (SRF) cavities and an SC quadrupole magnet combined with dipole correctors to focus and steer electron and positron beams. The magnets are installed between the SRF cavity string and at the longitudinal center of a common cryomodule/cryostat. These magnets are conductively cooled by pure aluminum channels thermally connected to a 2 K two-phase helium pipe for cooling the SRF cavities. A recent study shows that field-emitted electrons, so-called “dark current” initiated in the SRF cavities, are transmitted through the SRF cavity string and reach the SC magnet. The energy is inevitably absorbed in the SC coil due to the magnetic field, resulting in risks of a quench caused by the coil heating. We are investigating alternate magnet designs by using Nb $_{3}$ Sn or $\text{MgB}_{2}$ SC and by adding the dark current absorber surrounding the beam-pipe to realize sustainable magnet operation under the dark current heating. We report the design study of the magnet system and interfaces to the cryomodule accommodating it with the SRF cavities.

43 PARTICLE ACCELERATORS↗

Flat plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program being conducted at Lewis will provide the basis for selecting collectors for use at Langley. The technology program includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented herein.

Vernon, R. W.↗

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Honeycomb-Fin Heat Sink

Improved finned heat sink for electronic components more lightweight, inexpensive, and efficient. Designed for use with forced air, easily scaled up to dissipate power up to few hundred watts. Fins are internal walls of aluminum honeycomb structure. Cell structure gives strength to thin aluminum foil. Length of channels chosen for thermodynamic efficency; columns of cells combined in any reasonable number because flowing air distributed to all. Heat sink cools nearly as effectively at ends as near its center, no matter how many columns of cells combined.

Rippel, Wally E.↗