Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Magnetic field driven emergent phenomena: Insights from magneto-optics and nanoscopy

This review explores magnetic field-driven emergent phenomena across various material systems, emphasizing the pivotal roles of magneto-optical and nanoscopy techniques. We examine fundamental aspects of Landau electrodynamics in both 2D and 3D systems, including quantum Hall and topological magnetoelectric effects in graphene and topological insulators. Particularly attention is given to magnetic excitations and magnetopolaritons, such as surface magnon polaritons, magnetoplasmons, and magnetoexcitons in novel quantum materials, including quantum magnets and hybrid heterostructures. Advanced imaging techniques, such as scattering-type scanning near-field optical microscopy (SNOM) and microwave impedance microscopy, are showcased for their capability to resolve these phenomena with microscopic and nanoscopic resolution. These insights are complemented by discussions of advanced experimental approaches, including cryogenic environments, ultrafast pump-probe techniques, and the integration of magnetic fields into near-field optical methodologies. We further investigate the potential of these imaging techniques for unraveling complex magnetic orders, quantum phases, and correlated electronic behaviors. Finally, we offer perspectives on future research directions and highlight emerging opportunities in the evolving field of optical magneto-nanoscopy.

36 MATERIALS SCIENCE↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co-sputter deposition of Nb₃Sn layer into SRF cavity using Nb-Sn composite target

Nb₃Sn, with its superior superconducting critical temperature (Tc ~18.3 K) and superheating field (Hsh ~400 mT), is considered a promising material for superconducting radiofrequency (SRF) cavities, offering enhanced cryogenic performance compared to bulk niobium cavities. A Nb₃Sn coating technique has been developed for Nb SRF cavities using co-sputtering of Nb-Sn composite target in a DC cylindrical magnetron sputtering system. The composite target configuration and discharge conditions for co-sputtering were optimized to deposit Nb-Sn films on flat Nb substrates, followed by annealing to form Nb₃Sn. Multiple strategies have been explored to improve the surface homogeneity of the Nb₃Sn coating, including optimizing a two-step annealing process, annealing in Sn vapor, and a light Sn recoating process. A 1.5 µm Nb-Sn co-sputtered film was deposited on the interior of a 2.6 GHz Nb SRF cavity and annealed at 600 °C for 6 h, followed by 950 °C for 1 h. Cryogenic RF testing of the annealed cavity demonstrated a Tc of 17.8 K, confirming the formation of Nb₃Sn. Then, the annealed cavity underwent a light recoating treatment and attained a quality factor (Q0) of 8.5E+08 at 2.0 K.

Accelerator Physics↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Carbon Monoxide Oxidation on Cuprous Oxide

Performing oxidation reactions at low temperatures using earth-abundant materials is crucial for advancing solutions for sustainable chemistry. CO oxidation serves as a benchmark reaction to characterize oxidation and to advance fundamental concepts in surface chemistry. While there are several examples of CO oxidation occurring on metal oxides at low temperatures, from 300 K to ∼200 K, reactivity in the cryogenic temperature regime typically requires a metal nanoparticle on a metal oxide. Here, we show oxygen atoms on the (111) facet of Cu 2 O react with CO to form CO 2 at temperatures below 100 K. Combining spectroscopic experimental evidence with calculations, we propose a low barrier path for CO oxidation at reconstructed surface sites on Cu 2 O(111). This finding is a rare example of an earth-abundant metal oxide, in this case copper, that can provide highly reactive multifunctional sites, enabling both adsorption and reaction fundamental steps toward the efficient heterogeneous oxidation of chemicals.

36 MATERIALS SCIENCE↗

Commissioning Results of the ESR2 Compressors at JLab

Abstract The future operation of the 4 kW 15 Kelvin MOLLER experiment at Jefferson lab necessitates an increase of cryogenic capacity at the End Station Refrigerator. The current plant is the former 1.5 kW (4.5 K) ESCAR plant that has been operating at Jefferson Lab since 1995. The existing 1.5 kW plant is not able to support the load for MOLLER and will be replaced with a refurbished plant comprised of the cold box and compressors of the 4 kW ASST-A plant from the Superconducting Super Collider in Texas. This paper reports the commissioning results of the warm compressor system. We compare the compressors’ current and past performance, specifically examining their Isothermal and Volumetric efficiency. The results indicate that the refurbished equipment’s efficiency is comparable to its original performance, proving that the reuse and refurbishment of old systems is a worthwhile endeavor.

Perry, C. [Thomas Jefferson National Accelerator F↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monofluorinated acetal electrolyte for high-performance lithium metal batteries

High degree of fluorination for ether electrolytes has resulted in improved cycling stability of lithium metal batteries due to stable solid electrolyte interphase (SEI) formation and good oxidative stability. However, the sluggish ion transport and environmental concerns of high fluorination degree drive the need to develop less fluorinated structures. Here, we depart from the traditional ether backbone and introduce bis(2-fluoroethoxy)methane (F2DEM), featuring monofluorination of the acetal backbone. High coulombic efficiency and stable long-term cycling in Li||Cu half cells can be achieved with F2DEM even under fast Li metal plating conditions. The performance of F2DEM is further compared with diethoxymethane (DEM) and 2-[2-(2,2-difluoroethoxy)ethoxy]-1,1,1-trifluoroethane (F5DEE). A significantly lower overpotential is observed with F2DEM, which improves energy efficiency and enables its application in high-rate conditions. Comparative studies of F2DEM with DEM and F5DEE in anode-free lithium iron phosphate (LiFePO4) LFP pouch cells and high-loading LFP coin cells further show improved capacity retention of F2DEM electrolyte, demonstrating its practical applicability. More importantly, we also extensively investigate the underlying mechanism for the superior performance of F2DEM through various techniques, including X-ray photoelectron spectroscopy, scanning electron microscopy, cryogenic electron microscopy, focused ion beam, electrochemical impedance spectroscopy, and titration gas chromatography. Overall, F2DEM facilitates improved Li deposition morphology with reduced amount of dead Li. This enables F2DEM to show superior performance, especially under higher charging and slower discharging rate conditions.

25 ENERGY STORAGE↗

Multi-objective optimization of CEBAF heat load management and trip rates using AI/ML

The goal of this project is to investigate the use of RL to simultaneously optimize the cryogenic heat load and trip rate of the CEBAF linacs and make it generic to solve multi-objective problems that will enable its application at other Department of Energy (DOE) facilities with similar challenges. The existing approach optimizes the gradient distribution to minimize the trip rate and does not take into account the total heat load. A secondary objective of the project is the develop a framework to correct cavity quality curves (Q-curves) or RF-heat to Gradient relation curves for individual cavities. These curves are currently obtained using historical measurements and may have changed their behavior due to various events. Correction in these curves will allow us to accurately approximate the total RF heat generated by the linacs which is critical for the optimization.

43 PARTICLE ACCELERATORS↗

Machine Protection Studies of Fast Instability-Driven Beam Losses in the EIC Electron Storage Ring

Fast transverse beam instabilities represent one of the most challenging protection scenarios for the Electron-Ion Collider (EIC) electron storage ring (ESR). Coherent betatron oscillations driven by collective effects can grow rapidly and lead to substantial beam losses within only a few tens of turns, posing a threat to collimators, superconducting (SC) magnets, cryogenic systems, and detector components. A dedicated simulation framework based on distributed transverse excitations was developed to evaluate instability-driven beam losses in the ESR. A conservative instability rise time on the order of 10 turns was used to define a bounding protection scenario. Simulations show that the original two-collimator configuration is insufficient to localize losses under all operating conditions, whereas an optimized four-collimator configuration reduces loss leakage into protected regions by more than two orders of magnitude. Nevertheless, the most severe instability scenarios produce catastrophic beam impacts, with nearly half of the stored beam being intercepted by the collimators within a single turn, exceeding the preliminary estimated survivability limits of the baseline collimator design. The results demonstrate that collimation alone is insufficient to guarantee safe ESR operation and must be complemented by a fast machine-protection system. Dedicated turn-by-turn beam-position monitors and fast beam-loss monitors provide sufficient advance warning to detect instability growth and initiate a beam abort before equipment-damaging loss levels are reached. These findings establish quantitative requirements for the ESR machine-protection architecture and support the implementation of a multilayer protection strategy for both accelerator and detector systems.

43 PARTICLE ACCELERATORS↗

Local microwave sensing of excitons and their electrical environment

Excitons in atomically thin transition metal dichalcogenides (TMDs) possess intriguing optical properties, drawing interest for both technology and fundamental research. However, as the demands for nanodevice applications and the exploration of fundamental physics push toward smaller, subwavelength scales, studying them locally is challenging. In this work, we introduce a cryogenic scanning probe photoelectrical sensing technique, termed exciton-resonant microwave impedance microscopy (ER-MIM), to measure the excitonic responses in a monolayer MoSe 2 device at 1.5K. From the microwave signal changes, we identify exciton polarons and their Rydberg states. Building on these observations, we systemically reveal the local and nonlocal effects of carrier density, inhomogeneous electric fields, as well as dielectric screening on excitons, beyond the reach of conventional probes. By further integrating deep learning techniques, we precisely extracted the electrical parameters surrounding excitons, demonstrating a quantified, exciton-assisted nanoscale electrometry. Our results provide new insight into exciton-environment interactions, establish ER-MIM as a powerful optoelectronic sensing platform, and open avenues for exciton-based quantum control and device technologies.

scanning probe microscopy↗

Beam Induced Heating Analysis Update for the EIC Vacuum Chamber Components

One of the challenges of designing the Electron-Ion Col lider (EIC) is to mitigate beam-induced heating due to the intense electron and hadron beams. Heating of the ESR vac uum chamber components is mainly due to beam-induced resistive wall (RW) losses and synchrotron radiation. For the HSR heating is mainly due to large radial offsets and heat conduction from room temperature to cryogenic tem perature for cryo-components. In this paper, we provide an update on the beam-induced heating and thermal analysis of some critical ESR vacuum chamber components, such as the ESR Large Angle Bremhustraulung Monitor (LABM). We also provide a similar update for critical HSR vacuum com ponents, including the cryo-cooled BPM button assembly, beam screen, abort kicker, and polarimeter. To perform the thermal analyses, the resistive wall loss on individual compo nents is calculated with CST and the synchrotron radiation (if exists) is evaluated using SynRad. These losses, along with realistic boundary conditions are then fed to ANSYS to determine the temperature distribution.

43 PARTICLE ACCELERATORS↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Particle-in-cell techniques for the study of space charge effects in the Advanced Cryogenic Gas Stopper

The Facility for Rare Isotope Beams, FRIB, will significantly increase the rates and varieties of rare isotopes compared to those presently available at existing rare-isotope facilities. The production of stopped beams via the current generation of linear gas stopping devices available is not well matched to the beam intensities that will be available at FRIB. Many experiments that make use of reaccelerated beams, from the ReA facility, greatly benefit from having the highest-intensity, rare-isotope beams possible. Some experiments would also benefit greatly from stopped beams with improved purity. In this paper, the intensity bottlenecks of FRIB’s newest linear gas stopper are studied via experiment and simulation in support of a future detailed conceptual design of a next-generation linear gas stopper that can provide rare-isotope beams with rates of 10^8 pps, a factor of 50 higher than the current state-of-the-art system, with improved beam purity.

43 PARTICLE ACCELERATORS↗

Smooth, homogeneous, high-purity Nb 3 Sn superconducting RF resonant cavity by seed-free electrochemical synthesis

Abstract Workbench-size particle accelerators, enabled by Nb 3 Sn-based superconducting radio-frequency (SRF) cavities, hold the potential of driving scientific discovery by offering a widely accessible and affordable source of high-energy electrons and x-rays. Thin-film Nb 3 Sn RF superconductors with high quality factors, high operation temperatures, and high-field potentials are critical for these devices. However, surface roughness, non-stoichiometry, and impurities in Nb 3 Sn deposited by conventional Sn-vapor diffusion prevent them from reaching their theoretical capabilities. Here we demonstrate a seed-free electrochemical synthesis that pushes the limit of chemical and physical properties in Nb 3 Sn. Utilization of electrochemical Sn pre-deposits reduces the roughness of converted Nb 3 Sn by five times compared to typical vapor-diffused Nb 3 Sn. Quantitative mappings using chemical and atomic probes confirm improved stoichiometry and minimized impurity concentrations in electrochemically synthesized Nb 3 Sn. We have successfully applied this Nb 3 Sn to the large-scale 1.3 GHz SRF cavity and demonstrated ultra-low BCS surface resistances at multiple operation temperatures, notably lower than vapor-diffused cavities. Our smooth, homogeneous, high-purity Nb 3 Sn provides the route toward high efficiency and high fields for SRF applications under helium-free cryogenic operations.

Physics↗

First High-Gradient Results of UED/UEM SRF Gun at Cryogenic Temperatures

Benefiting from the rapid progress on RF photogun technologies in the past two decades, the development of MeV range ultrafast electron diffraction/microscopy (UED and UEM) has been identified as an enabling instrumentation. UEM or UED use low power electron beams with modest energies of a few MeV to study ultrafast phenomena in a variety of novel and exotic materials. SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb₃Sn and conduction cooling. The use of Nb₃Sn allows to operate SRF cavities at higher temperatures (4K) with low power dissipation which is within the reach of commercially available closed-cycle cryocoolers. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. In this paper, we present first high gradient results of the gun conducted in liquid helium.

43 PARTICLE ACCELERATORS↗

Distributed Magnetic Field and Temperature Monitoring for Superconducting Radio Frequency Cavities

The overall objective of the proposed Phase I program was to design, construct and demonstrate a fiber optic sensing system capable of providing temperature and magnetic field measurements with an enhanced spatial resolution that can be implemented over a large surface area (cryomodules) to survey superconducting radio frequency cavities and magnets. A magnetic field sensor capable of detecting fluxes on the order of 1 μT is required to detect the distribution of trapped flux on the cavity surface. A unique distributed magnetic field sensor was successfully designed and constructed to demonstrate the detection of magnetic fluxes less than 500 nT. The sensor leveraged the ultra-high sensitivity of Sentek’s picoDAS to measure the magnetostriction induced vibrations in a commercially available Metglas 2605 SC ribbon that was in physical contact with sensing fiber. Static magnetic fields were detected by applying an alternating current a copper wire proximate to the Metglas 2605SC ribbon to create an AC bias magnetic field. In an alternative approach, an AC bias magnetic field was applied to a special magnetic field sensing fiber with Metglas 2605SC cladding successfully detect a magnetic field flux of a 3 μT. Exhaustive testing was performed to characterize the dependency of sensor response on the direction of the applied magnetic field. Although the special sensing fiber based magnetic field sensor did not exhibit an observable dependence on the direction of the magnetic field, the Metglas 2605SC ribbon sensor exhibited a clear directional dependence. A wide variety of polymer materials were evaluated to enhance the temperature response of an FBG based sensor at cryogenic temperatures. The processing and performance challenges provided the motivation to develop a new simple cryogenic temperature sensor that uses a commercially available fiber optic splice protector. The EVA hot melt tube that becomes adhered to the optical fiber and the polyolefin outer tube that shrinks upon heating in the fusion splicer heater provide the high thermal expansion coefficient necessary to impart a significant strain on the FBG when exposed to cryogenic temperatures. The temperature sensitivity (Δ𝜆𝐵𝑟𝑎𝑔𝑔~ 62 𝑝𝑝𝑚/℃) of the FBG-based sensor was on par with the best reported to date. The simple design, use of readily available cost-effective materials, and well-established processing techniques lends this approach to the creation of hundreds to thousands of temperature sensors on one single optical fiber length. The inherently small form factor also allows for co-location with the distributed magnetic field sensor. In preparation for field testing of the prototype sensing system at the Jefferson Labs in potential Phase II program, several different cable designs were evaluated to package the sensors. The preliminary successful demonstration of fully functional sensing cables provides the foundation for subsequent development efforts to advance the Technology Readiness Level of the technology. The technical feasibility of the proposed approach was successfully demonstrated in this Phase I effort.

43 PARTICLE ACCELERATORS↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗