Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

There and Back Again: Reimagining Cryogenic Cooling for Scalable Arrays of Dilution Refrigerators for future Quantum Datacenters

While pulse tube cryocoolers enabled the rapid expansion of dilution refrigerator technology over the past two decades, the transition to large-scale quantum systems is now driving a reassessment of the DR’s higher-temperature-stage cooling strategies and how these systems can be effectively scaled in a modular way. Quasi-wet architectures based on centralized cryoplants and forced-flow helium distribution offer compelling advantages in energy efficiency, operational cost, and scalability. With appropriate redundancy, standardized interfaces, and optimized distribution system designs, these architectures will provide a practical and robust path forward for the next generation of quantum computing infrastructure.

Hansen, B. [Fermilab]↗

Metallic magnetic calorimeters

Metallic magnetic calorimeters (MMC) are calorimetric particle detectors, typically operated at temperatures below 100 mK, that make use of a paramagnetic temperature sensor to transform the temperature rise upon the absorption of a particle in the detector into a measurable magnetic flux change in a dc-SQUID. During the last years a growing number of groups has started to develop MMC for a wide variety of applications, ranging from alpha-, beta- and gamma-spectrometry over the spatially resolved detection of accelerated molecule fragments to arrays of high resolution x-ray detectors. For x-rays with energies up to 6 keV an energy resolution of 2.7 eV (FWHM) has been demonstrated and we expect that this can be pushed below 1 eV with the next generation of devices. We give an introduction to the physics of MMCs and summarize the presently used readout schemes as well as the typically observed noise contributions and their impact on the energy resolution. We discuss general design considerations, the micro-fabrication of MMCs and the performance of micro-fabricated devices. In this field large progress has been achieved in the last years and the thermodynamic properties of most materials approach bulk values allowing for optimal and predictable performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research on long pulse ECRH system of EAST in support of ITER

Experimental Advanced Superconducting Tokamak (EAST), as a fully superconducting tokamak in China, aims to achieve high performance plasma under steady-state operation. To fulfill the physical objectives of EAST, a program of 4-MW long pulse electron cyclotron resonance heating and current drive (EC H&CD) system, which would offer greater flexibility for plasma shape and plasma stabilization has been launched on EAST since 2011. The system, composed of 4 gyrotrons with nominal 1MW output power and 1000s pulse length each, is designed with the feature of steerable power handling capabilities at 140 GHz, using second harmonic of the extraordinary mode(X2). The missions of the ECRH system are to provide plasma heating, current drive, plasma profile tailoring and control of magneto-hydrodynamic (MHD) instabilities. Presently, the first two 140-GHz 1-MW gyrotrons, provided by GYCOM and CPI, respectively, have been tested at long pulse operation. The tubes, the associated power supplies, cooling system, cryogenic plant, 2 transmission lines and an equatorial launcher are now installed at EAST. The power generated from each tube will be transmitted by an evacuated corrugated waveguide transmission line and injected into plasma from the low field side (radial port) through a front steering equatorial launcher. Considering the diverse applications of the EC system, the beam’s launch angles can be continuously varied with the optimized scanning range of over 30° in poloidal direction and ±25° in toroidal, as well as the polarization could be adjusted during the discharge by the orientations of a pair of polarizers in the transmission line to maintain the highest absorption for different operational scenarios. The commissioning of the first 2MW ECRH plant for EAST is under way. The design, R&D activities and recent progress of the long pulse 140-GHz ECRH system are presented in this paper. As the technological requirements for EAST ECRH have many similarities with ITER devices, the installation and experience of EAST ECRH system may provide valuable data for the ITER.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development FD-SOI MOSFET Amplifiers for Integrated Read-Out Circuit of Superconducting-Tunnel-Junction Single-Photon-Detectors

We proposed a new high-resolution single-photon infrared spectrometer for search for radiative decay of cosmic neutrino background (CνB). The superconducting-tunnel-junctions(STJs) are used as a single-photon counting device. Each STJ consists of Nb/Al/Al x O y /Al/Nb layers, and their thicknesses are optimized for the operation temperature at 370 mK cooled by a 3 He sorption refrigerator. Our STJs achieved the leak current 250 pA, and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio (S/N). FD-SOI MOSFETs can be operated at cryogenic temperature of 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a nonlinear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors is 0.4 mV, and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET-based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp is required to have a fast response (GBW ≥ 100 MHz), and it must have low power dissipation as compared to the cooling power of refrigerator.

47 OTHER INSTRUMENTATION↗

Nanoscale Elemental Mapping of Intact Solid–Liquid Interfaces and Reactive Materials in Energy Devices Enabled by Cryo-FIB/SEM

Many modern energy devices rely on solid–liquid interfaces, highly reactive materials, or both, for their operation and performance. The difficulty of characterizing such materials means these devices often lack high-resolution characterization in an unaltered state. Here, we demonstrate how cryogenic sample preparation and transfer can extend the capabilities of FIB/SEM techniques to solid–liquid interfaces and reactive materials common to energy devices by preserving their integrity through all stages of preparation and characterization. We additionally show how cryo-FIB/SEM paired with energy dispersive X-ray spectroscopy enables nanoscale elemental mapping of cross-sections produced in these materials and discuss strategies to achieve optimal results. Finally, we consider current limitations of the technique and propose future developments that could enhance its capabilities. Our results illustrate that cryo-FIB/SEM will be a useful technique for fields where solid–liquid interfaces or reactive materials play an important role and could, thus far, not be characterized at high resolution.

25 ENERGY STORAGE↗

Bulk and Surface Charge Collection: CDMS Detector Performance and Design Implications

The Cryogenic Dark Matter Search (CDMS) searches for Weakly Interacting Massive Particles (WIMPs) with cryogenic germanium particle detectors. These detectors discriminate between nuclear-recoil candidate and electron-recoil background events by collecting both phonon and ionization energy from interactions in the crystal. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron-recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk charge trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices shows that hydrogen passivation of the amorphous silicon blocking layer does not reduce the effects of surface trapping. Other data shows that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors increases surface trapping, causing a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and at the experimental site in Soudan, MN have provided methods to optimize the neutralization process and monitor running conditions to maintain maximal ionization collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mobile Néel skyrmions at room temperature: status and future

Magnetic skyrmions are topologically protected spin textures that exhibit many fascinating features. As compared to the well-studied cryogenic Bloch skyrmions in bulk materials, we focus on the room-temperature Néel skyrmions in thin-film systems with an interfacial broken inversion symmetry in this article. Specifically, we show the stabilization, the creation, and the implementation of Néel skyrmions that are enabled by the electrical current-induced spin-orbit torques. Towards the nanoscale Néel skyrmions, we further discuss the challenges from both material optimization and imaging characterization perspectives.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Cryogenic Dark Matter Search: First 5-Tower Data and Improved Understanding of Ionization Collection

The Cryogenic Dark Matter Search (CDMS) is searching for Weakly Interacting Massive Particles (WIMPs) with cryogenic particle detectors. These detectors have the ability to discriminate between nuclear recoil candidate and electron recoil background events by collecting both phonon and ionization energy from recoils in the detector crystals. The CDMS-II experiment has completed analysis of the first data runs with 30 semiconductor detectors at the Soudan Underground Laboratory, resulting in a world leading WIMP-nucleon spin-independent cross section limit for WIMP masses above 44 GeV/c 2 . As CDMS aims to achieve greater WIMP sensitivity, it is necessary to increase the detector mass and discrimination between signal and background events. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are surface and bulk trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices has shown that hydrogen passivation of the amorphous silicon blocking layer worsens surface trapping. Additional data has shown that the iron-ion implantation used to lower the critical temperature of the tungsten transition-edge sensors causes a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and in situ at the experimental site have provided methods to optimize the neutralization process and monitor running conditions to maintain full ionization collection. This work details my contribution to the 5-tower data taking, monitoring, and analysis effort as well as the SuperCDMS detector development with the focus on monitoring and improving ionization collection in the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

CASSIS: The Cornell atlas of Spitzer/infrared spectrograph sources. II. HIGH-Resolution observations

The Infrared Spectrograph (IRS) on board the Spitzer Space Telescope observed about 15,000 objects during the cryogenic mission lifetime. Observations provided low-resolution (R=λ/Δλ≈60−127) spectra over ≈5−38 μm and high-resolution (R≈600) spectra over 10–37 μm. The Cornell Atlas of Spitzer/IRS Sources (CASSIS) was created to provide publishable quality spectra to the community. Low-resolution spectra have been available in CASSIS since 2011, and here we present the addition of the high-resolution spectra. The high-resolution observations represent approximately one-third of all staring observations performed with the IRS instrument. While low-resolution observations are adapted to faint objects and/or broad spectral features (e.g., dust continuum, molecular bands), high-resolution observations allow more accurate measurements of narrow features (e.g., ionic emission lines) as well as a better sampling of the spectral profile of various features. Given the narrow aperture of the two high-resolution modules, cosmic ray hits and spurious features usually plague the spectra. Our pipeline is designed to minimize these effects through various improvements. A super-sampled point-spread function was created in order to enable the optimal extraction in addition to the full aperture extraction. The pipeline selects the best extraction method based on the spatial extent of the object. For unresolved sources, the optimal extraction provides a significant improvement in signal-to-noise ratio over a full aperture extraction. We have developed several techniques for optimal extraction, including a differential method that eliminates low-level rogue pixels (even when no dedicated background observation was performed). The updated CASSIS repository now includes all the spectra ever taken by the IRS, with the exception of mapping observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

Ultra-short pulse laser acceleration of protons to 80 MeV from cryogenic hydrogen jets tailored to near-critical density

Laser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes. Here, we demonstrate that the interaction of petawatt-class laser pulses with a pre-formed micrometer-sized cryogenic hydrogen jet plasma overcomes these limitations enabling tailored density scans from the solid to the underdense regime. Our proof-of-concept experiment demonstrates that the near-critical plasma density profile produces proton energies of up to 80 MeV. Based on hydrodynamic and three-dimensional particle in cell simulations, transition between different acceleration schemes are shown, suggesting enhanced proton acceleration at the relativistic transparency front for the optimal case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailor-Made Microporous Metal–Organic Frameworks for the Full Separation of Propane from Propylene Through Selective Size Exclusion

Adsorptive separation of olefin/paraffin mixtures by porous solids can greatly reduce the energy consumption associated with the currently employed cryogenic distillation technique. Here, the complete separation of propane and propylene by a designer microporous metal–organic framework material is reported. The compound, Y 6 (OH) 8 (abtc) 3 (H 2 O) 6 (DMA) 2 (Y-abtc, abtc = 3,3',5,5'-azobenzene-tetracarboxylates; DMA = dimethylammonium), is rationally designed through topology-guided replacement of inorganic building units. Y-abtc is both thermally and hydrothermally robust, and possesses optimal pore window size for propane/propylene separation. It adsorbs propylene with fast kinetics under ambient temperature and pressure, but fully excludes propane, as a result of selective size exclusion. Multicomponent column breakthrough experiments confirm that polymer-grade propylene (99.5%) can be obtained by this process, demonstrating its true potential as an alternative sorbent for efficient separation of propane/propylene mixtures.

36 MATERIALS SCIENCE↗

Investigating Cryogenic Pump Lifetime and Exploring Alternative Designs

Cryogenic pumps are necessary for the operation of several neutrino experiments at Fermilab where some of the primary components of the detectors are liquid argon and liquid nitrogen. The pumps currently in use are centrifugal pumps with a small vortex impeller, manufactured by Barber Nichols. This pump has an average lifetime of 8000 hours. Such a short lifetime means that each pump requires maintenance multiple times a year, which is not optimal. The goal of this project was to determine what aspects of the current pump design could be modified to improve the lifetime of the pump such that it would only require maintenance once a year. In this poster I present on the different areas of design improvement that were identified.

Baakkonen, Katie↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

Neural network accelerator for quantum control

Efficient quantum control is necessary for practical quantum computing implementations with current technologies. Conventional algorithms for determining optimal control parameters are computationally expensive, largely excluding them from use outside of the simulation. Existing hardware solutions structured as lookup tables are imprecise and costly. By designing a machine learning model to approximate the results of traditional tools, a more efficient method can be produced. Such a model can then be synthesized into a hardware accelerator for use in quantum systems. In this study, we demonstrate a machine learning algorithm for predicting optimal pulse parameters. This algorithm is lightweight enough to fit on a low-resource FPGA and perform inference with a latency of 175 ns and pipeline interval of 5 ns with > 0.99 gate fidelity. In the long term, such an accelerator could be used near quantum computing hardware where traditional computers cannot operate, enabling quantum control at a reasonable cost at low latencies without incurring large data bandwidths outside of the cryogenic environment.

43 PARTICLE ACCELERATORS↗

Imaging and microanalysis of thin ionomer layers by scanning transmission electron microscopy

Improved conditions for imaging and spectroscopic mapping of thin perfluorosulfonic acid (PFSA) ionomer layers in fuel cell electrodes by scanning transmission electron microscopy (STEM) have been investigated. These conditions are first identified on model systems of Nafion ionomer-coated nanostructured thin films and nanoporous Si. The optimized conditions are then applied in a quantitative study of the ionomer through-layer loading for two typical electrode catalyst coatings using electron energy loss and energy dispersive X-ray spectroscopy in the transmission electron microscope. The e-beam induced damage to the perfluorosulfonic acid (PFSA) ionomer is quantified by following the fluorine mass loss with electron exposure and is then mitigated by a few orders of magnitude using cryogenic specimen cooling and a higher incident electron voltage. Multivariate statistical analysis is also applied to the analysis of spectrum images for data denoising and unbiased separation of independent components related to the catalyst, ionomer, and support.

Cullen, David A↗

High Quantum Efficiency Uni-Traveling-Carrier Photodiode for Optical to Microwave Transduction

Modern Quantum Information Systems (QIS) employ optical photons for long distance communication, operating at ambient temperature, between microwave cavities, which house microwave photons used in quantum computing and microwave detection. These optical photons, carried by fiber-optic or free-space links, offer a low-cost, uncooled alternative to bulky, expensive microwave coaxial cables, which are lossy, susceptible to EMI, and a significant thermal conductor to the outside ambient environment. To convert between these two types of photons and implement these optical interconnects, it is necessary to develop a high-performance photodetector for optical to microwave transduction. Freedom Photonics and the University of Virginia have a well-established partnership in developing high-performance photodiodes. In this Phase I effort, we collaborated in designing, fabricating, and testing an advanced, high-speed, high quantum efficiency prototype photodiode for transduction from optical to microwave frequencies. These devices have applications not only in quantum computing and axion detection, but also in other optical-cryogenic interconnect applications, in fields such as radio astronomy and quantum cryptography, as well as in quantum metrology and plasmonics. During this Phase I DOE program, we designed, fabricated, and tested prototype PIN GaAs photodiodes which targeted the performance parameters defined by the program. This process involved identifying a new target wavelength, different from that proposed initially, based on conversations with the Oak Ridge National Lab customer. We designed an epitaxial stack, optimized in theory for ≥95% quantum efficiency at 795 nm, ≥5 GHz, per the target objectives of the program. Additionally, we designed a fabrication process and associated mask plates for top-illuminated, AR-coated devices with device diameters ranging from 50 µm to 800 µm. Using these, we fabricated two 3” wafer quarters of devices, and characterized the devices’ dark current, quantum efficiency, and bandwidth for various device diameters. The prototype devices achieved a quantum efficiency of 89% at the target 795 nm detection wavelength. The bandwidth of the devices proved tricky to characterize, but a 50 µm diameter device shows a 3-dB bandwidth of at least 1.6 GHz, possibly a full 5 GHz, depending on the measurement setup. In the future, we plan to characterize the bandwidth of these devices using an impulse response measurement. All tasks for the Phase I were successfully completed, and sample prototype devices were provided to Oak Ridge National Lab Quantum Information Science researchers. The work performed in Phase I has established a strong foundation for future design and fabrication cycles in Phase II, if granted. The early tests at Oak Ridge National Labs will provide guidance for the required photodiode performance in devices to be supplied in Phase II.

42 ENGINEERING↗