Search NASA⌕ Search

SEARCH · Search NASA

Results for “decarbonization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sensitization and Mechanical Response of Cu‐Containing Steel Rods

The iron and steel manufacturing sector significantly adds to global greenhouse gas emissions, caused primarily by the carbothermic reduction of iron ore. Recycling scrap steel offers an effective decarbonization strategy but introduces impurities like copper (Cu) that can negatively impact mechanical properties. This study investigates the effects of Cu content and heat treatment on the mechanical performance and sensitization of steel wire rods for tire manufacturing. Steel rods with 0.04 and 0.21 wt% Cu are heated to 1050 or 1200 °C, then air quenched, or furnace cooled. Tensile testing coupled with microscopic analysis is used to evaluate mechanical properties and assess the sensitization effects. Higher Cu content leads to larger sensitized zones with increased Cu precipitation along grain boundaries. Ductility and toughness, crucial for wire drawability, are found to be reduced, despite higher ultimate strength. Slower furnace cooling is seen to result in smaller sensitized zones compared to air quenching, suggesting a pivotal role of cooling rate in sensitization control. The findings provide insights into optimize heat treatment parameters and Cu content limits, balancing mechanical performance and maintaining drawability for enhanced scrap steel recycling in tire production.

copper↗

What drives embodied carbon policy? A global perspective on adoption

Abstract Embodied carbon refers to the greenhouse gas emission associated with the lifecycle of buildings. Embodied carbon policies are critical for addressing the environmental impact of construction materials and advancing climate goals. Despite their importance, the adoption of embodied carbon policies has been limited globally, influenced by economic, environmental, institutional, and trade factors. This study employs structural equation modeling to analyze 37 countries, testing ten hypotheses across four categorical factors. The base model reveals the significant influence of environmental vulnerability and institutional frameworks on policy adoption, while robustness models confirm the critical role of trade dependencies and economic competitiveness in shaping national embodied carbon strategies. Findings underscore that countries with high climate vulnerability and strong institutional support are more likely to adopt embodied carbon policies. Conversely, trade-reliant nations face challenges balancing competitiveness and sustainability. Policy implications suggest the need for international collaboration to align trade policies with carbon reduction goals, targeted support for vulnerable nations, and the integration of embodied carbon considerations into existing climate frameworks. These results offer a roadmap for policymakers to design more effective and equitable embodied carbon policies, fostering global progress toward sustainable construction and decarbonization.

Hu, Ming (ORCID:0000000325831161)↗

Valuing Maintenance Strategies for Fusion Plants as Part of a Future Electricity Grid

Scheduled maintenance is likely to be lengthy and therefore consequential for the economics of fusion power plants. The maintenance strategy that maximizes the economic value of a plant depends on internal factors such as the cost and durability of the replaceable components, the frequency and duration of the maintenance blocks, and the external factors of the electricity system in which the plant operates. Here, this paper examines the value of fusion power plants with various maintenance properties in a decarbonized United States Eastern Interconnection circa 2050. Seasonal variations in electricity supply and demand mean that certain times of year, particularly spring to early summer, are best for scheduled maintenance. Seasonality has two important consequences. First, the value of a plant can be 15% higher than what one would naively expect if value were directly proportional to its availability. Second, in some cases, replacing fractions of a component in shorter maintenance blocks spread over multiple years is better than replacing it all at once during a longer outage, even through the overall availability of the plant is lower in the former scenario.

power plant, maintenance, seasonality, electricity↗

Graphene reinforced UHMWPE fibers

Thermoplastic polymers are increasingly used in electric vehicles, hydrogen fuel cell vehicles, and other decarbonization applications due to their lightweight and formability. Higher-strength polymers are needed to supplant metals in the vehicle structure, thereby reducing mass and improving efficiency. Ultra-high molecular weight polyethylene (UHMWPE) fibers possess one of the highest strength-to-weight ratios of technical polymers, and further improvement via reinforcement by nanofillers, such as graphene, will expand their performance envelope. Here, in this work, UHMWPE/graphene nanocomposite fibers were gel spun and characterized for their morphological, microstructural, thermal, and mechanical properties. The addition of a low fraction of graphene improved the tensile strength of the fibers by 25% and tensile modulus by 32%. Differential scanning calorimetry showed an increase in melting temperature and degree of crystallinity, which indicates improved coordination of the molecular chains induced by the addition of graphene. The reinforcement also affected the cross-sectional shape of the fibers; the aspect ratio of the fibers’ elliptical shape declined with increasing graphene content showing the skeletal effect of the graphene nanofillers in the polymer matrix. The reinforcing effect of graphene declined above a threshold concentration, and theoretical modeling was applied to demonstrate that increased agglomerates led to reduced properties. This work demonstrates a simple, effective method to produce graphene-reinforced UHMWPE fibers and lays a foundation for understanding the potential for leveraging graphene to form ultra-high-performance nanocomposite fibers for myriad engineering applications.

36 MATERIALS SCIENCE↗

The environmental impact of hydropower: a systematic review of the ecological effects of sub-daily flow variability on riverine fish

Hydropower can help facilitate power grid decarbonization because it can respond to short-term changes in power demand and is comparatively more reliable than intermittent wind and solar. However, flexible hydropower operations can create rapid and abnormal fluctuations in downstream flow conditions, which can negatively impact aquatic ecosystems. Accordingly, we conducted a systematic review on the ecological effects of hydropower-driven sub-daily flow variability (SDFV) on riverine fishes. We reviewed and synthesized 109 articles relevant to fish-SDFV relationships from seven sources, most of which focused on Salmonids in North America and northern and western Europe and were published in the last 15 years. We found strong agreement in the literature that SDFV increases fish stranding risk, destabilizes habitat, and decreases production and diversity. We found moderate agreement that SDFV interrupts fish reproduction, increases or has no impact on condition, and prompts or discourages movement depending on local channel conditions. We found little to no agreement for relationships between SDFV and mortality, physiology, and behavior. The effects of SDFV on riverine fish ecology are intertwined in the complex suite of biotic and abiotic characteristics that structure aquatic ecosystems and are highly site-, species-, and life stage-specific. Assessments of the impact of SDFV on fish ecology should first characterize local habitat and channel quality and fish community composition to identify specific, measurable ecological outcomes to sustain or enhance, and then design mitigation strategies tailored to those ecological objectives.

13 HYDRO ENERGY↗

A Review of Medium-Mn, Low-Density Steels for Transportation Applications

Low-density steels constitute a broad and complex alloy space (Fe–Mn–Al–C) suitable for a variety of applications. In particular, there has been growing interest in duplex (ferrite + austenite) or multiphase (+ martensite, carbides) low-density steels as a lightweight, advanced high-strength steel (AHSS) for vehicle applications, spurred by extensive decarbonization efforts. Medium-Mn (med-Mn) (3 to 12 wt pct) steels with 3.5 to 10 wt pct Al additions have decreased densities, presenting an interesting opportunity for high-specific strength, intrusion-resistant, and energy-absorbing sheet components with reduced alloying contents compared to high-Mn grades like austenitic Fe–Mn–Al–C or twinning-induced plasticity steels. Compared to leaner med-Mn steels, the physical metallurgy of med-Mn, low-density steels (MMLS) is complex and distinguished by increased δ-ferrite fractions and austenite stacking fault energies, decreased martensite start temperatures, and modified phase transformation windows. Mechanical properties of MMLS are comparable to 3rd generation AHSS, attributable to the unique, multiphase microstructures, and the array of strengthening mechanisms that can be accessed. Despite this, challenges and unknowns remain with respect to their industrial implementation, and new processing routes may need to be developed. Here, this review aims to highlight the composition effects, processing methods, microstructural evolution, deformation behavior, and application properties geared toward manufacturing and performance, altogether assessing the potential of MMLS for transportation applications.

36 MATERIALS SCIENCE↗

Red Mud: From Industrial Waste to a Flux for Manufacturing Sustainable Iron/Steel

Here, this study highlights the potential of red mud/bauxite residue, an industrial waste product generated during alumina extraction as a flux for iron and steelmaking. The thermodynamic feasibility of using red mud as a flux in the presence of different reducing agents is evaluated. Potential approaches to decarbonize iron and steel production while utilizing red mud as a flux, as well as the benefits of red mud remnant after iron extraction, are discussed.

36 MATERIALS SCIENCE↗

Expert and operator perspectives on barriers to energy efficiency in data centers

Abstract It was last estimated in 2016 that data centers (DCs) comprise approximately 2% of total US electricity consumption. However, this estimate is currently being updated to account for the massive increase in computing needs due to streaming, cryptocurrency, and artificial intelligence (AI). To prevent energy consumption that tracks with increasing computing needs, it is imperative we identify energy efficiency strategies and investments beyond the low-hanging fruit solutions. In a two-phased research approach, we ask: What non-technical barriers still impede energy efficiency (EE) practices and investments in the data center sector, and what can be done to overcome these barriers? In particular, we are focused on social and organizational barriers to EE. In Phase I, we performed a literature review and found that technical solutions are abundant in the literature, but fail to address the top-down cultural shifts that need to take place in order to adapt new energy efficiency strategies. In Phase II, reported here, we interviewed 16 data center operators/experts to ground-truth our literature findings. Our interview protocols focus on three aspects of DC decision-making: procurement practices, metrics and monitoring, and perceived barriers to energy efficiency. We find that vendors are the key drivers of procurement decisions, advanced efficiency metrics are facility-specific, and there is convergence in the design of advanced facilities due to the heat density of parallelized infrastructure. Our ultimate goals for our research are to design DC decarbonization policies that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Assessing Climate Change-Induced Variability in Generation Potential and Droughts of Renewable Energy Systems in India

Solar photovoltaic (PV) and wind energy systems are crucial for decarbonizing the electricity sector and achieving climate goals. However, these systems are weather-dependent, and ignoring the potential changes in their generation levels due to climate change could compromise achieving climate targets and meeting future electricity demand. This study evaluates the impact of climate change on the generation potential of wind and solar PV systems in India for three future periods, 2030 (2021-2040), 2050 (2041-2060), and 2070 (2061-2080) compared to the baseline year 2000 (1991-2010), under three emission scenarios: SSP245, SSP370, and SSP585. Solar PV generation levels consistently decline (up to 10 %) across all regions and scenarios. Wind energy shows more pronounced variability (-20 % to 30 %). The South and Southeastern regions of India show improvements in wind potential across all scenarios and time periods. This study also investigated the projected changes in the generation droughts of both energy systems. For solar PV, drought days increase across most regions (exceeding 500 days under SSP370 across the 20-year period). In contrast, wind energy sees a reduction in drought days, especially in parts of South and Southeast India (declines exceeding 50 days across different scenarios). For both energy systems, the patterns of generation drought and generation potential are similar, and indicate that Western and Northern India may be less favorable for the future expansion of solar PV and wind energy, respectively. These results highlight the need to account for the potential impacts in future capacity planning.

14 SOLAR ENERGY↗

Ten questions on future and extreme weather data for building simulation and analysis in a changing climate

Weather plays a significant role in building operations as it directly influences HVAC loads and in turn the building energy and thermal performance. In a changing climate, future trends and extreme weather events become critical concerns in the global building decarbonization and clean energy transition. This paper aims to address ten key questions concerning extreme and future weather data for building applications, and more importantly to identify research gaps and guide the curation and selection of future and extreme weather data for use in building performance simulation and assessment. The paper intends to inform architects and engineers, operators, owners, policy makers, and other stakeholders on considering the impacts of future and extreme weather data and adopting strategies for selecting and applying this data in various use cases related to building design, operation, and retrofit for energy efficiency, electrification, and climate resilience.

Yan, Da↗

Reactivity of net-zero carbon alcohol fuels and their corresponding aldehyde intermediates on PGM-based commercial oxidation catalysts for lean-burn emissions control

Alcohol net-zero carbon fuels will play a significant role in decarbonization of the hard-to-electrify transportation sectors. However, the combustion process in alcohol-fueled engines generate toxic aldehydes. For commercialization of net-zero carbon fuels on engines, compliance with the stringent U.S. EPA regulations is necessary. Here, this contribution focuses on reactivity of alcohols and aldehydes on commercial diesel oxidation catalysts (DOC) to inform selection of future net-zero carbon fuels. Alcohol (and aldehyde) light-off temperatures were measured on aged DOCs under full synthetic engine-exhaust conditions. Methanol was the most reactive, while ethanol completely oxidized at higher temperatures. Alcohols typically formed less reactive aldehyde intermediates. DRIFTS revealed strongly adsorbing surface formates and acetates during methanol and ethanol oxidation, respectively, resulting in inhibition effects. Preliminary alcohol oxidation mechanisms combining flow reactor and DRIFTS observations are presented. Aldehydes inhibited CO oxidation. Minimal N 2 O formation was observed for the alcohols investigated.

Alcohol oxidation↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗