Search NASA⌕ Search

SEARCH · Search NASA

Results for “demand aggregation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integration of Retail and Wholesale Markets: Modeling Framework and Stability Analysis

As power systems cope with increasing amounts of renewable generation, there is an increasing need to engage flexible demand-side resources and distributed energy resources (DERs) into power systems operations. However engagine millions of DERs in a reliable manner into power systems operations can be a challenging problem. Retail markets can facilitate this by providing a platform to aggregate the flexibility of DERs and bid the aggregate flexibility into wholesale markets. However, unlike generators (which can typically be modeled accurately with capacity constraints and ramping limits), most flexible loads have physical dynamics (like air conditioners) that couples their flexibility over time. This coupling could have unintended undesirable consequences (for example, instability and oscillations in prices and other physical quantities). In this paper, we propose a simple model to capture evolution of load flexibility over time and analyze stability of the interconnection between wholesale and retail electricity markets. We prove that under a natural model of flexibility evolution (assuming a constant base load), oscillations cannot occur and prices converge to a unique equilibrium model quickly.

Ramachandran, Thiagarajan↗

Considerations for Distributed Edge Data Centers and Use of Building Loads to Support Large Interconnections

The rapid expansion of artificial intelligence (AI) and machine learning is driving unprecedented electricity demand from data centers. It is predicted that by 2030, 90% of AI workloads will be inference-based, requiring interconnection of multiple low-latency edge data centers (<20 MW) sited closer to end users - often on already constrained distribution feeders. Although individually small, these loads can aggregate to large loads per feeder, straining infrastructure, creating multi-year interconnection delays, and driving up customer costs. This paper proposes a data center-focused grid-integration framework that combines feeder hosting capacity analysis with building energy efficiency, building load flexibility, and waste heat reuse to expand effective feeder and substation headroom. Such approaches can reduce interconnection delays, lower costs for ratepayers, and accelerate AI-ready infrastructure deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

POINT: Partially Observable Imitation Network for Traffic Signal Control

Smart traffic signals bring together transportation infrastructure and advance technologies to improve the mobility and efficiency of urban transportation network. Adaptive traffic signal control studies can be categorized into modeling-based approaches and learning-based approaches. In order to take advantages of these two systems, this study developed an offline-online combined Partial Observable Imitation Network for Traffic signal control (POINT). In the offline system, the traffic signal timing optimization problem was formulated as a Mixed Integer Nonlinear Programming (MINLP) given complete traffic information, i.e., second-by-second speeds and locations of all vehicles. Furthermore, the objective of MINLP is to minimize total travel delays considering individual vehicle trajectories under Connected Vehicle (CV) environment. The calculated optimal solutions under various traffic conditions were considered as the ”expert” decisions. In the online system, an imitation neural network model was developed to learn the ”expert” signal plans generated from offline system. Given partial observable traffic conditions in real time, e.g., the aggregate-level of traffic volume, the POINT model can compute the signal timing parameters in the online system. The numerical results demonstrated that the proposed method outperformed other state-of-the-art signal control method under high and unbalanced traffic demand levels in terms of reducing travel delays and queue length.

33 ADVANCED PROPULSION SYSTEMS↗

BASIN-3D Data Integration for Selected ARM Data Field Campaign Report

The purpose of this data services request was to demonstrate integration of the Atmospheric Radiation Measurement (ARM) User Facility’s “met” datastreams with time series data from other earth science data sources using the BASIN-3D data synthesis software tool. BASIN-3D is an open-source Python library that enables researchers to integrate data across configured public and private data sources. It provides a common query language for researchers to request measurement locations and time series data based on specified locations, variables, time period, statistics, aggregation, and data quality. BASIN-3D acquires the data that match the query from each configured data source and translates the results into harmonized vocabularies, thus reducing researchers' data-wrangling effort. In addition, because the queries are executed on demand, researchers can easily regenerate their synthesized data sets as new data and/or data updates become available, eliminating one-off data products. BASIN-3D can output data using a variety of different data structures for end-user applications including Python pandas data frames and hdf5 output formats.

54 ENVIRONMENTAL SCIENCES↗

Demand modelling of passenger air travel: An analysis and extension. Volume 1: Background and summary

The framework for a model of travel demand which will be useful in predicting the total market for air travel between two cities is discussed. Variables to be used in determining the need for air transportation where none currently exists and the effect of changes in system characteristics on attracting latent demand are identified. Existing models are examined in order to provide insight into their strong points and shortcomings. Much of the existing behavioral research in travel demand is incorporated to allow the inclusion of non-economic factors, such as convenience. The model developed is characterized as a market segmentation model. This is a consequence of the strengths of disaggregation and its natural evolution to a usable aggregate formulation. The need for this approach both pedagogically and mathematically is discussed.

Jacobson, I. D.↗

The economic impact of NASA R and D spending: Executive summary

An evaluation of the economic impact of NASA research and development programs is made. The methodology and the results revolve around the interrelationships existing between the demand and supply effects of increased research and development spending, in particular, NASA research and development spending. The INFORUM Inter-Industry Forecasing Model is used to measure the short-run economic impact of alternative levels of NASA expenditures for 1975. An aggregate production function approach is used to develop the data series necessary to measure the impact of NASA research and development spending, and other determinants of technological progress, on the rate of growth in productivity of the U. S. economy. The measured relationship between NASA research and development spending and technological progress is simulated in the Chase Macroeconometric Model to measure the immediate, intermediate, and long-run economic impact of increased NASA research and development spending over a sustained period.

Evans, M. K.↗

Longitudinal data analysis in support of functional stability concepts for leachate management at closed municipal landfills

Highlights: • Longitudinal data analysis using a mixed-effects regression model. • Dataset consisted of a total of 1402 samples from 101 closed municipal landfills. • Target analytes and classes generally showed predictable degradation trends. • Validates historical studies focused on macro organic indicators such as BOD. • BOD can serve as “gateway” indicator for planning leachate management. - Abstract: Landfill functional stability provides a target that supports no environmental threat at the relevant point of exposure in the absence of active control systems. With respect to leachate management, this study investigates “gateway” indicators for functional stability in terms of the predictability of leachate characteristics, and thus potential threat to water quality posed by leachate emissions. Historical studies conducted on changes in municipal solid waste (MSW) leachate concentrations over time (longitudinal analysis) have concentrated on indicator compounds, primarily chemical oxygen demand (COD) and biochemical oxygen demand (BOD). However, validation of these studies using an expanded database and larger constituent sets has not been performed. This study evaluated leachate data using a mixed-effects regression model to determine the extent to which leachate constituent degradation can be predicted based on waste age or operational practices. The final dataset analyzed consisted of a total of 1402 samples from 101 MSW landfills. Results from the study indicated that all leachate constituents exhibit a decreasing trend with time in the post-closure period, with 16 of the 25 target analytes and aggregate classes exhibiting a statistically significant trend consistent with well-studied indicators such as BOD. Decreasing trends in BOD concentration after landfill closure can thus be considered representative of trends for many leachate constituents of concern.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study of appliance ownership and electricity consumption determinants in urban Ghanaian households

The residential sector in Ghana accounts for about 40% of aggregate electricity consumption out of which urban centers contribute 70%. The high weighted share of residential electricity use is attributed to high appliance ownership and use, and other household/building factors. The ability to determine how changes in the pattern of these factors influence electricity demand is critical if efforts to reduce consumption are to be effective. Here this study combines a residential electricity consumption survey (RECS) with electricity end-use monitoring of 60 households in Tema city Ghana, to yield the first ever comprehensive investigation of city-scale electricity consumption in urban Ghanaian homes. A multiple linear regression analysis is used to identify the most statistically significant indicators of appliance ownership and household electricity consumption. Results indicate that ownership of air conditioner, freezer, fan, refrigerator and television; and changes in socio-economic and building factors such as energy efficiency awareness and practice; income; household size and floor space show high statistical significance, and collectively explain 57% variance in households’ total electricity consumption. The presence of dependent children increases ownership of television, iron, washing machine and small kitchen appliances. This work provides a solid foundation for developing more tailored energy-saving policy interventions targeted at households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distinguishing magnetic particle size of iron oxide nanoparticles with first-order reversal curves

Magnetic nanoparticles encompass a wide range of scientific study and technological applications. The success of using the nanoparticles in various applications demands control over size, dispersibility, and magnetics. Hence, the nanoparticles are often characterized by transmission electron microscopy (TEM), X-ray diffraction, and magnetic hysteresis loops. TEM analysis requires a thin layer of dispersed particles on the grid, which may often lead to particle aggregation thus making size analysis difficult. Magnetic hysteresis loops on the other hand provide information on the bulk property of the material without discriminating size, composition, and interaction effects. First order reversal curves (FORCs), described as an assembly of partial hysteresis loops originating from the major loop are efficient in identifying the domain size, composition, and interaction in a magnetic system. This study presents FORC diagrams on a variety of well-characterized biogenic and synthetic magnetite nanoparticles. It also introduces deconvoluted reversible and irreversible components from FORC as an important method for obtaining a semi-quantitative measure of the effective magnetic particle size. This is particularly important in a system with aggregation and interaction among the particles that often leads to either the differences between physical size and effective magnetic size. We also emphasize the extraction of secondary components by masking dominant coercivity fraction on FORC diagram to explore more detailed characterization of nanoparticle systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Factors Influencing Building Demand Flexibility

The U.S. Department of Energy’s National Roadmap for Grid-interactive Efficient Buildings (GEB) acknowledged that building demand flexibility (DF) is both an important strategy to decarbonizing the buildings sector and an important resource for meeting the changing needs of the electrical grid such as improving grid reliability. However, understanding the complexity and uncertainties in real building field performance of DF strategies is a large gap hindering stakeholders on both grid and buildings side to make investments on deploying such strategies. The research work in this report intended to advance understanding of the variability and influential factors in building demand flexibility. Adding such knowledge based on lab testing results and measured performance data from real buildings is an important contribution. The report uses standardized metrics and methods to quantify DF performance from field-measured DF datasets of two significant building groups of big-box retail and medium office buildings to present the challenge of building DF variability in multiple dimensions. The report presents findings related to how several key factors influence building demand flexibility from implementing a common, cost-effective DF control strategy (i.e., adjusting zone temperatures). The findings are supported by full-scale lab testing, field data analysis and simulation research. The authors also provided application-oriented recommendations to stakeholders such as building aggregators, utility program design professionals, sophisticated building portfolio owners, and more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Individual Data Sparsity in Smart Thermostat Big Data: Impacts on Modeling Thermostat Use Behavior Dynamics

This study explores the impacts of the sparsity of individual thermostat interaction data on modeling thermostat use behavior dynamics using a dataset of over 100,000 smart thermostats. In developing a data-driven model of Thermal Frustration Theory (TFT), we investigate the challenges and trade-offs in clustering occupant data to enhance predictive accuracy. Our findings reveal that a single, aggregated model fails to capture the diversity of occupant behaviors, resulting in extremely poor prediction performance. Conversely, excessive clustering exacerbates data sparsity, undermining model reliability. By identifying an optimal clustering strategy, we achieve a balance that significantly improves the prediction of manual setpoint changes during demand response (DR) events, enhancing energy management and occupant comfort

Fannon, David↗

A Kinetic Monte Carlo Approach for Simulating Cascading Transmission Line Failure

In this work, cascading transmission line failures are studied through a dynamical model of the power system operating under fixed conditions. The power grid is modeled as a stochastic dynamical system where first-principles electromechanical dynamics are excited by small Gaussian disturbances in demand and generation around a specified operating point. In this context, a single line failure is interpreted in a large deviation context as a first escape event across a surface in phase space defined by line security constraints. The resulting system of stochastic differential equations admits a transverse decomposition of the drift, which leads to considerable simplification in evaluating the quasipotential (rate function) and, consequently, computation of exit rates. Tractable expressions for the rate of transmission line failure in a restricted network are derived from large deviation theory arguments and validated against numerical simulations. Extensions to realistic settings are considered, and individual line failure models are aggregated into a Markov model of cascading failure inspired by chemical kinetics. Cascades are generated by traversing a graph composed of weighted edges representing transitions to degraded network topologies. Numerical results indicate that the Markov model can produce cascades with qualitative power-law properties similar to those observed in empirical cascades.

Kinetic Monte Carlo, rare events, Cascading Failur↗

Simulated building energy demand biases resulting from the use of representative weather stations

Numerical building models are typically forced with weather data from a limited number of “representative cities” or weather stations representing different climate regions. The use of representative weather stations reduces computational costs, but often fails to capture spatial heterogeneity in weather that may be important for simulations aimed at understanding how building stocks respond to a changing climate. We quantify the potential reduction in bias from using an increasing number of weather stations over the western U.S. The approach is based on deriving temperature and load time series using incrementally more weather stations, ranging from 8 to roughly 150, to capture weather across different seasons. Using 8 stations, one from each climate zone, across the western U.S. results in an average absolute summertime temperature bias of 7.2°F with respect to a spatially-resolved gridded dataset. The mean absolute bias drops to 2.8°F using all available weather stations. Temperature biases of this magnitude could translate to absolute summertime mean simulated load biases as high as 13.8%, a significant error for capacity expansion planners who may use these types of simulations. Increasing the size of the domain over which biases are calculated reduces their magnitude as positive and negative biases may cancel out. Using 8 representative weather stations can lead to a 20-40% overestimation of peak building loads during both summer and winter. Using weather stations close to population centers reduces both mean and peak load biases. This approach could be used by others designing aggregate building simulations to understand the sensitivity to their choice of weather stations used to drive the models.

Burleyson, Casey D.↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Synthetic residential load models for smart city energy management simulations

The ability to control tens of thousands of residential electricity customers in a coordinated manner has the potential to enact system-wide electric load changes, such as reduce congestion and peak demand, among other benefits. To quantify the potential benefits of demand-side management and other power system simulation studies (e.g. home energy management, large-scale residential demand response), synthetic load datasets that accurately characterize the system load are required. This study designs a combined top-down and bottom-up approach for modelling individual residential customers and their individual electric assets, each possessing their own characteristics, using time-varying queueing models. The aggregation of all customer loads created by the queueing models represents a known city-sized load curve to be used in simulation studies. The three presented residential queueing load models use only publicly available data. An open-source Python tool to allow researchers to generate residential load data for their studies is also provided. The simulation results presented consider the ComEd region (utility company from Chicago, IL) and demonstrate the characteristics of the three proposed residential queueing load models, the impact of the choice of model parameters, and scalability performance of the Python tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand modelling of passenger air travel: An analysis and extension, volume 2

Previous intercity travel demand models in terms of their ability to predict air travel in a useful way and the need for disaggregation in the approach to demand modelling are evaluated. The viability of incorporating non-conventional factors (i.e. non-econometric, such as time and cost) in travel demand forecasting models are determined. The investigation of existing models is carried out in order to provide insight into their strong points and shortcomings. The model is characterized as a market segmentation model. This is a consequence of the strengths of disaggregation and its natural evolution to a usable aggregate formulation. The need for this approach both pedagogically and mathematically is discussed. In addition this volume contains two appendices which should prove useful to the non-specialist in the area.

Jacobson, I. D.↗