Search NASA⌕ Search

SEARCH · Search NASA

Results for “detection efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

Holistic Measurement Driven Resilience: Combining Operational Fault and Failure Measurements and Fault Injection for Quantifying Fault Detection, Propagation and Impact. Final report

For HPC systems to date, application resilience to faults and failures has been accomplished by the brute- force method of checkpoint/restart, which allows an application to make forward progress in the face of system and application faults, errors, and failures independent of root cause or end result. It has remained the primary resilience mechanism because we lack a way to identify faults and anticipate consequences early enough to take meaningful mitigating action. However, checkpoint/restart implementations put a tremendous burden on system resources and on the applications themselves and is becoming less feasible at scale. Because we have not yet operated at scales at which checkpoint/restart fails to provide forward progress, despite increasing costs, vendors have had little motivation to provide the instrumentation necessary for early identification of faults and failures. However, as we move from petascale to exascale, component mean time to failure (MTTF) will render the existing techniques ineffectual and/or too expensive. Furthermore, fault recovery mechanisms such as failover and/or error correction introduce performance inconsistency. Instrumentation allowing early indication of problems and tools to enable use of such information by systems, operating systems, and applications offer an alternative, more scalable and less costly solution. In the HMDR project, we built on our experience and expertise developed and accumulated over years of research on design, monitoring, measurement, and assessment of resilient computing systems. Analysis of field data on the current and past generations of extreme-scale systems revealed several challenges that, if not addressed in increasingly larger and more complex systems, may hinder the effectiveness of future exascale computing systems. Specifically, i) file systems and interconnects in current-generation large-scale systems already operate at the margins of resiliency, including consistent performance, and may not scale to larger deployments; ii) automated, software-based failover mechanisms are frequently inadequate and can introduce wider failures, such that failures during recovery may lead to system/application failures, including system-wide outages; and iii) silent data corruption represents a critical fault mode and will require efficient detection mechanisms if next-generation applications are to take full advantage of exascale hardware. To address the above challenges, we assembled a team of world-renowned experts in resilient extreme- scale computing from the University of Illinois (Electrical and Computer Engineering, Computer Science, and NCSA), SNL, LANL, NERSC, and Cray. Our team includes representatives from centers that house many of the largest HPC resources in the world, both today and over the coming years. The team has a unique track record of research in i) system and application failure characterization based on the analysis of field data, ii) data-driven design of fault/error detection mechanisms, and iii) experimental characterization of system/application resiliency. The team includes system owners/operators who provide continuous data collection and access and ensure installation of appropriate analysis tools.

97 MATHEMATICS AND COMPUTING↗

Cathodoluminescence of Ultrathin Twisted Ge 1–x Sn x S van der Waals Nanoribbon Waveguides

Ultrathin van der Waals semiconductors have shown extraordinary optoelectronic and photonic properties. Propagating photonic modes make layered crystal waveguides attractive for photonic circuitry and for studying hybrid light-matter states. Accessing guided modes by conventional optics is challenging due to limited spatial resolution and poor out-of-plane far field coupling. Scanning near-field optical microscopy (SNOM) can overcome these issues and can characterize waveguide modes down to tens of nm resolution, albeit for planar samples or nanostructures with moderate height variations. Electron microscopy provides atomic-scale localization also for more complex geometries, and recent advances extended the accessible excitations from interband transitions to phonons. In this work, bottom-up synthesized layered semiconductor (Ge 1-x Sn x S) nanoribbons with axial twist and deep sub-wavelength thickness are demonstrated as a platform for realizing waveguide modes, and cathodoluminescence (CL) spectroscopy is introduced as a tool to characterize them. Combined experiments and simulations show the excitation of guided modes by the electron beam and their efficient detection via photons emitted in the ribbon plane, which enables measuring key properties such as the evanescent field into the vacuum cladding with nanometer resolution. The results identify van der Waals waveguides operating in the infrared and highlight an electron microscopy-based approach for probing complex-shaped nanophotonic structures.

36 MATERIALS SCIENCE↗

Probing non-standard neutrino interactions with supernova neutrinos at Hyper-K

Non-standard neutrino self interactions (NSSI) could be stronger than Fermi interactions. We investigate the ability to constrain these four-neutrino interactions by their effect on the flux of neutrinos originating from a galactic supernova. In the dense medium of a core collapse supernova, these new self interactions can have a significant impact on neutrino oscillations, leading to changes at the flavor evolution and spectra level. We use simulations of the neutrino flux from a 13 solar mass, core collapse supernova at 10 kpc away, and numerically propagate these neutrinos through the stellar medium taking into account vacuum/MSW oscillations, SM ν – ν scattering as well as ν – ν interactions that arise from NSSI. We pass the resulting neutrino flux to a simulation of the future Hyper-Kamiokande detector to see what constraints on NSSI parameters are possible when the next galactic supernova becomes visible. We find that these constraints depend strongly on the neutrino mass hierarchy and if the NSSI is flavor-violating or preserving. Sensitivity to NSSI in the normal hierarchy (NH) at Hyper-K is limited by the experiment’s ability to efficiently detect ν e , but deviations from no NSSI could be seen if the NSSI is particularly strong. In the inverted hierarchy (IH) scenario, Hyper-K can significantly improve constraints on flavor-violating NSSI down to O(10 –1 )G F .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Amplitude analysis and branching-fraction measurement of ${D}_s^{+}\to {K}_S^0{\pi}^{+}{\pi}^0$

By using 6.32 fb -1 of data collected with the BESIII detector at center-of-mass energies between 4.178 and 4.226 GeV, we perform an amplitude analysis of the decay $D^+_s$→$K^0_Sπ^+π^0$ and determine the relative fractions and phase differences of different intermediate processes, which include $K^0_Sρ$(770) + ,$K^0_Sρ$(1450) + , $K^*$(892)$^0π^+$, $K^*$(892)$^+π^0$, and $K^*$(1410)$^0π^+$. With the detection efficiency based on the amplitude analysis results, the absolute branching fraction is measured to be $\mathcal{B}$($D^+_s$→$K^0_Sπ^+π^0$)=(5.43±0.30 stat ±0.15 syst )×10 -3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Expected sensitivity of the Light Dark Matter eXperiment to long-lived dark photons and axion-like particles

The Light Dark Matter eXperiment (LDMX) is an electron-beam fixed-target experiment primarily designed to achieve world-leading, model-independent sensitivity to sub-GeV dark matter particles. LDMX aims to identify dark sector particle production through the detection of events with substantial missing energy and momentum, a signature of invisible particles escaping detection. Beyond this primary objective, LDMX offers a complementary search strategy for long-lived, visibly decaying particles, such as dark photons and axion-like particles. We present the first detailed evaluation of the ability of LDMX to identify visibly decaying, long-lived particles that couple to electrons using a detailed simulation, based on the Geant 4-toolkit, that incorporates realistic detection efficiencies and background levels. We demonstrate that LDMX can achieve a sensitivity that is competitive with other experiments that are currently running. The models explored in this paper are distinct and complementary to those probed in the LDMX flagship missing-momentum analysis. Through searching for both invisible dark matter and visibly decaying long-lived signatures, LDMX will significantly advance the search for light dark matter and provide a broad exploration of the sub-GeV dark sector.[graphic not available: see fulltext]

Akesson, Torsten [Lund U.] (ORCID:0000000341415408↗

Amplitude analysis and branching fraction measurement of the decay $\mathrm{D}_s^+$ → $\mathrm{K}^+π^+π^-π^0$

The singly Cabibbo-suppressed decay D$^+_s$ → K + π + π - π 0 is observed by using a data set corresponding to an integrated luminosity of 6.32 fb -1 recorded by the BESIII detector at the centre-of-mass energies between 4.178 and 4.226 GeV. The first amplitude analysis of D$^+_s$ → K + π + π - π 0 reveals the sub-structures in this decay and determines the fractions and relative phases of different intermediate processes. The dominant intermediate process is D$^+_s$ → K *0 ρ + , with a fit fraction of (40.5 ± 2.8 stat. ± 1.5 syst. )%. With the detection efficiency based on our amplitude analysis, the absolute branching fraction for D$^+_s$ → K + π + π - π 0 is measured to be (9.75 ± 0.54 stat. ± 0.17 syst. ) x 10 -3 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Assessment of two benzylation strategies for the analysis of nerve-agent derived ethyl- and pinacolyl methyl phosphonic acids in sandy loam soil by GC–MS

Despite their prohibition by the Chemical Weapons Convention, nerve agents (NAs) remain in use against military and civilian targets. Due to their high reactivity, NAs readily degrade to phosphonic acids, making them important markers in the inspection of areas of presumed NA use. In this work, we assess the use of benzylation to modify ethyl- and pinacolyl methylphosphonic acids, degradation products of VX and Soman respectively, for their efficient detection in a soil matrix at ~10 and ~1 μg/g using GC–MS. The soil matrix, Sandy Loam (SL), was chosen for its ubiquitous nature, complex composition with silica particles embedded in clay, and low organic content. In this study, we demonstrate that benzylation via benzyl bromide yields a LOD = 25.6 ng/mL for benzylated-EMPA and LOD = 30.1 ng/mL for benzylated-PMPA. This is superior to the use of p-methoxybenzyl trichloroacetimidate in providing stable phosphonic acid ester derivatives for analysis. A base-modified procedure for p-methoxybenzylation was explored in this study yielding a LOD = 29.1 ng/mL for p-methoxybenzylated-EMPA and LOD = 39.8 ng/mL for p-methoxybenzylated-PMPA. Both benzylation pathways (benzyl bromide and p-methoxybenzyl trichloroacetimidate) can be used to yield phosphonic acid derivatives that provide further confirmation of these Soman and VX degradation products in soil samples in investigative scenarios. The work herein represents the first application of benzylation methods for the analysis of these NA markers in the acidic, silicon-based SL soil.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the complex chemistry of grain boundaries in K-doped BaFe 2 As 2 with atom probe tomography

Iron-based superconductors have attractive properties for high-field applications, but there is a lack of understanding of the effect of grain boundary chemistry on the in-field performance. The near atomic-scale resolution, ppm sensitivity and 3D analysis offered by atom probe tomography make it a powerful tool to investigate the nanoscale structure and chemistry of these defects in fine-grained K-doped BaFe 2 As 2 samples. A computational method to systematically extract and compare the Gibbsian interfacial excess of chemical species across grain boundaries has been explored in this work. The robustness of the method has been tested by evaluating the effects of selected variables on simulated APT datasets. The accuracy and precision of the calculated Gibbsian interfacial excess were found to be stable over a range of analysis conditions: varying grain boundary widths and detection efficiencies, spatial precisions below 1.5 nm, and bin widths between 1.2 and 1.6 nm. For the K-doped BaFe 2 As 2 samples studied, segregation of As, Ba, K and impurities of O, Na, and Sb were found at grain boundaries. The Gibbsian excess values were found to vary widely between different boundaries, showing the complexity of the grain boundary chemistry in this material. Possible links between the observed critical current density (Jc) of these samples and their nano- and micro-structure have also been investigated and discussed.

36 MATERIALS SCIENCE↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Multianode Photomultiplier Tubes for use in the CLAS12 RICH detector

In this work, we present results of the detailed study of several hundred Hamamatsu H12700 Multianode Photomultiplier Tubes (MaPMTs), characterizing their response to the Cherenkov light photons in the second Ring Imaging Cherenkov detector, a part of the CLAS12 upgrade at Jefferson Lab. The total number of pixels studied was 25536. The single photoelectron spectra were measured for each pixel at different high voltages and light intensities of the laser test setup. Using the same dedicated front-end electronics as in the first RICH detector, the setup allowed us to characterize each pixel’s properties such as gain, quantum efficiency, signal crosstalk between neighboring pixels, and determine the signal threshold values to optimize their efficiency to detect Cherenkov photons. A recently published state-of-the-art mathematical model, describing photon detector response functions measured in low light conditions, was extended to include the description of the crosstalk contributions to the spectra. The database of extracted parameters will be used for the final selection of the MaPMTs, their arrangement in the new RICH detector, and the optimization of the operational settings of the front-end electronics. The results show that the characteristics of the H12700 MaPMTs satisfy our requirements for the position-sensitive single photoelectron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automated QC station for the calibration of the Mu2e calorimeter readout units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗