Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

In Situ Performance of the Low Frequency Array for Advanced ACTPol

The Advanced Atacama Cosmology Telescope Polarimeter (AdvACT) is an upgrade for the Atacama Cosmology Telescope using Transition Edge Sensor (TES) detector arrays to measure cosmic microwave background (CMB) temperature and polarization anisotropies in multiple frequencies. The low frequency (LF) array was deployed early 2020. It consists of 292 TES bolometers observing in two bands centered at 27 GHz and 39 GHz. At these frequencies, it is sensitive to synchrotron radiation from our galaxy as well as to the CMB, and complements the AdvACT arrays operating at 90, 150 and 230 GHz. We present the initial LF array on-site characterization, including the time constant, optical efficiency and array sensitivity.

Superconducting detectors↗

Development of a Compact, Ground-Based Ozone DIAL System

We are developing a portable, eye-safe, ground-based ozone lidar instrument specialized for ozone differential absorption lidar (DIAL) measurements in the troposphere. This prototype instrument is intended to operate at remote field sites and to serve as the basic unit for future monitoring projects requiring multi-instrument networks, such as that proposed for the Global Tropospheric Ozone Project (GTOP). GTOP is currently being formulated by a scientific panel of the International Global Atmospheric Chemistry Project to meet its goal to better understand the processes that control the global distribution of tropospheric ozone. In order for the lidar to be widely deployed in networks, it must be fairly easy to use and maintain as well as being cost-competitive with ground station launching ozone sondes which operate several times a day. To achieve these goals, emphasis is placed upon the incorporation of: (1) all-solid state transmitters which can reliably produce 20-40 mJ pulses; (2) a highly efficient, narrow-bandpass receiver; (3) dual analog and photon-counting detector channels; and (4) flexible, user-friendly control software.

Chyba, T. H.↗

Flame detector operable in presence of proton radiation

A detector of ultraviolet radiation for operation in a space vehicle which orbits through high intensity radiation areas is described. Two identical ultraviolet sensor tubes are mounted within a shield which limits to acceptable levels the amount of proton radiation reaching the sensor tubes. The shield has an opening which permits ultraviolet radiation to reach one of the sensing tubes. The shield keeps ultraviolet radiation from reaching the other sensor tube, designated the reference tube. The circuitry of the detector subtracts the output of the reference tube from the output of the sensing tube, and any portion of the output of the sensing tube which is due to proton radiation is offset by the output of the reference tube. A delay circuit in the detector prevents false alarms by keeping statistical variations in the proton radiation sensed by the two sensor tubes from developing an output signal.

Walker, D. J.↗

Dynamic Isolation for Cryogenic Refrigerators

Prototype pressure-compensated mounting isolates a Tunable Diode Laser (TDL) housing from mechanical vibration. Mounting is being tested as part of Langley Research Center program for development of highly sensitive instruments that remotely measure important chemical constituents of atmosphere. Instruments typically have requirement for cryogenic cooling of sensitive detectors and components that are necessary to detect presence of tenuous constituents of atmosphere. Key elements of mounting are two bellows, reaction plate, flexible straps and vibration isolators.

Averill, R. D.↗

A Far Infrared Echelle Spectrometer for the Kuiper Airborne Observatory

A liquid-helium-cooled grating spectrometer (CGS) is being developed as a facility instrument for the Kuiper Airborne Observatory (KAO), primarily to study for infrared lines originating in the interstellar medium. A maximum resolving power of approximately 6000 is achieved by means of a 45 cm long Echelle grating and is optically capable of operating in the spectral range from 25 to 300 microns. An array of detectors is used to simultaneously measure a line and the adjacent continuum from astronomical sources. Currently six detectors allow measurements in the 30 to 120 micron spectral band. The instrument, its operation, and its performance are described.

Erickson, E. F.↗

Thermal detectors for high resolution spectroscopy

Cryogenic microcalorimeters can be made sensitive enough to measure the energy deposited by a single particle or X-ray photon with an accuracy of about one electron volt. It may also be possible to construct detectors of several-kilograms mass whose resolution is only a few times worse than this. Data from relatively crude test devices are in good agreement with thermal performance calculations, and a total system noise of 11 eV FWHM has been obtained for a silicon detector operating at 98 mK. Observations of 35 eV FWHM for 6-keV X-rays with a different device have been made.

Mccammon, D.↗

Dust streams from comet Shoemaker-Levy 9?

In 1991 and 1992, the dust detector onboard the Ulysses spacecraft detected several dust streams apparently originating from the jovian system. The timing and measured speeds of the final two dust streams are compatible with dust from comet Shoemaker-Levy 9's (SL9) disruption in 1992. Our further investigations of stream characteristics and dust acceleration mechanisms, however, shed some doubt that two of the eleven dust streams are of SL9 origin. In July 1994 when SL9 impacts Jupiter, the Galileo spacecraft will be about 3500 jovian radii away from the planet. Submicronsized dust released into, and accelerated by, the jovian magnetosphere during this event may reach Galileo and impact its dust detector between September and November 1994. We also discuss the possibility of directly sampling dust from SL9 during Galileo's orbital tour.

Grun, E.↗

Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays

LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable.

Rausch, Adam J.↗

In-flight absolute radiometric calibration of the Thematic Mapper

In order to determine temporal changes of the absolute radiometric calibration of the entire TM system in flight spectroradiometric measurements of the ground and the atmosphere were made simultaneously with TM image collections over the White Sands, NM area. By entering the measured values in an atmospheric radiative transfer program, the radiance levels in four of the spectral bands of the TM were determined, band 1: 0.45 to 0.52 micrometers, band 2: 0.53 to 0.61 micrometers, band 3: 0.62 to 0.70 micrometers, and 4: 0.78 to 0.91 micrometers. These levels were compared to the output digital counts from the detectors that sampled the radiometrically measured ground area, thus providing an absolute radiometric calibration of the entire TM system utilizing those detectors. Previously announced in STAR as N84-15633

Castle, K. R.↗

Design of a Particle Beam Satellite System for Lunar Prospecting

One potential use for neutral particle beam (NPB) technology is as an active orbital probe to investigate the composition of selected locations on the lunar surface. Because the beam is narrow and can be precisely directed, the NPB probe offers possibilities for high resolution experiments that cannot be accomplished using passive techniques. Rather, the combination of both passive and active techniques can be used to provide both full-coverage mapping (passively) at low resolution (tens of kilometers) and high-resolution information for discrete locations of special interest. A preliminary study of NPB applicability for this dual-use application was recently conducted. The study was completed in Feb. 1993. A novel feature was the consideration of the use of a Russian launch vehicle (e.g., the Proton). The use of other Russian space hardware and capabilities was also encouraged. This paper describes the lunar prospector system design. Other researchers discuss the issues and opportunities involving lunar scientific experimentation using an NPB. The NPB lunar prospector utilizes a modified design of the Far Field Optics Experiment (FOX). Like the Earth-orbiting FOX, the core capability of the NPB lunar prospector will be a pulsed RF LINAC that produces a 5-MeV proton beam that is projected to the target with a 30-micro-r beam divergence and a 10-micro-r beam-pointing accuracy. Upon striking the lunar surface, the proton beam will excite characteristic radiation (e.g., X-rays) that can be sensed by one or more detectors on the NPB platform or on a separate detector satellite.

Berwald, D. H.↗

A bolometric millimeter-wave system for observations of anisotropy in the cosmic microwave background radiation on medium angular scales

The performance of a bolometric system designed to measure the anisotropy of the cosmic microwave background (CMB) radiation on angular scales from 0.3 to 3 deg is presented. The system represents a collaborative effort combining a low-background 1-m diameter balloon-borne telescope with new multimode feed optics, a beam modulation mechanism with high stability, and a four-channel bolometric receiver with passbands centered near frequencies of 3, 6, 9, and 12/cm (90, 180, 270, and 360 GHz). The telescope has been flown three times with the bolometric receiver and has demonstrated detector noise limited performance capable of reaching sensitivity levels of about 0.00001 with detectors operated at 0.3 K.

Fischer, M. L.↗

An interpretation of the broadband VLF waves near the Io torus as observed by Ulysses

The requirements for the Ulysses trajectory to attain high ecliptic latitudes using a Jovian gravitational assist resulted in a fortuitous passage through the Io torus region. Specifically, the spacecraft spent many hours at latitudes just above the torus. During this time the low-frequency cutoff of an ordinary mode (O mode) emission allowed a determination of the local electron plasma frequency (i.e., electron density) along the northern flank of the torus. Also, near a Jovian System III longitude of 100 deg, the spacecraft flew past a set of active field lines that have been previously identified to be associated with the hectometric generation region. During the passage, Ulysses observed a newly discovered O mode component and a whistler mode emission similar to that observed by Voyager 1 13 years previously. All of the broadband VLF emissions imply the presence of a particular population of electrons. We suggest that broadband VLF emissions can be used as a `particle detector' to qualitatively measure the electron plasma conditions in the torus region and identify active regions.

Farrell, W. M.↗

The NANOGrav 12.5 yr Data Set: The Frequency Dependence of Pulse Jitter in Precision Millisecond Pulsars

Low-frequency gravitational-wave experiments require the highest timing precision from an array of the moststable millisecond pulsars. Several known sources of noise on short timescales in single radio pulsar observationsare well described by a simple model of three components: template fitting from a finite signal-to-noise ratio, pulsephase/amplitude jitter from single-pulse stochasticity, and scintillation errors from short-timescale interstellarscattering variations. Currently template-fitting errors dominate, but as radio telescopes push toward higher signalto-noise ratios, jitter becomes the next dominant term for most millisecond pulsars. Understanding the statistics ofjitter becomes crucial for properly characterizing arrival time uncertainties. We characterize the radio frequencydependence of jitter using data on 48 pulsars in the North American Nanohertz Observatory for GravitationalWaves timing program. We detect significant jitter in 43 of the pulsars and test several functional forms for itsfrequency dependence; we find significant frequency dependence for 30 pulsars. We find moderate correlations ofrms jitter with pulse width (R = 0.62) and number of profile components (R = 0.40); the single-pulse rms jitter istypically 1% of pulse phase. The average frequency dependence for all pulsars using a power-law model hasindex 0.42. We investigate the jitter variations for the interpulse of PSR B1937+21 and find no significantdeviations from the main pulse rms jitter. We also test the time variation of jitter in two pulsars and find thatsystematics likely bias the results for high-precision pulsars. Pulsar timing array analyses must properly modeljitter as a significant component of the noise within the detector.

Lam, M. T.↗

Intruder detection system

An intruder detection system is described. The system contains a transmitter which sends a frequency modulated and amplitude modulated signal to a remote receiver in response to a geophone detector which responds to seismic impulses created by the intruder. The signal makes it possible for an operator to determine the number of intruders and the manner of movement.

Lee, R. D.↗