Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Advanced Atmospheric Sounder and Imaging Radiometer (AASIR)

Design information for the Advanced Atmospheric Sounder and Imaging Radiometer is reported, which was developed to determine the configuration of a sensor for IR and visible imaging. The areas of technology reported include: systems design, optics, mechanics, electronics, detectors, radiative cooler, and radiometric calibration.

Source record↗

The energy spectrum of cosmic ray electrons between 9 and 300 GeV

The high-energy cosmic-ray electron spectrum between 9 and 300 GeV has been measured using an instrument consisting of a combination of a transition-radiation detector and a shower detector. The instrument has been calibrated at accelerators over the energy range 5-300 GeV and has been exposed in a balloon flight for 9.3 sq m sr hr. The design of the instrument and the data analysis procedures are described. It is found that the electron spectrum is significantly steeper than the proton spectrum. If the spectrum is fitted to a single power law, a spectral index of 3.35 is obtained. This suggests the influence of radiative energy losses on galactic electrons at low energies. The results are interpreted in the context of the homogeneous model for galactic cosmic rays.

Prince, T. A.↗

The High Visible Resolution (HVR) instrument of the spot ground observation satellite

Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.

Otrio, G.↗

A study to identify research issues in the area of electromagnetic measurements and signal handling of remotely sensed data

Research issues in the area of electromagnetic measurements and signal handling of remotely sensed data are identified. The following seven issues are discussed; platform/sensor system position and velocity, platform/sensor attitudes and attitude rates, optics and antennas, detectors and associated electronics, sensor calibration, signal handling, and system design.

Source record↗

Nimbus-6 and -7 Earth Radiation Budget (ERB) sensor details and component tests

Construction details and operating characteristics are described for the thermopile (used in the solar and fixed-Earth channels) and the pyroelectric detector (used in the Earth-scanning channels) carried on the Nimbus 6 and the Nimbus 7 satellites for gathering Earth radiation budget data. Properties of the black coating for the detectors, and sensor testing and calibration are discussed.

Soule, H. V.↗

Honeywell multispectral linear array (MLA) instrument design A system overview

In support of NASA's Experimental Land Observing System, a simple, reliable and relatively inexpensive multispectral linear array (MLA) instrument concept has been developed. The design satisfies requirements for multichannel radiometry and wide field imaging. A reflective off-axis anastigmat telescope is mounted in a highly strength-to-weight efficient truss structure, coupled to a solid beamsplitter assembly. Attention is given to the optical design of the MLA instrument, the telescope structure, the detector arrays, detector cooling, on-orbit calibration, signal processing electronics, the spacecraft interfaces, the modulation transfer function, the signal-to-noise ratio, radiometric accuracy, and spatial registration.

Eyring, D.↗

The Earth Radiation Budget Experiment nonscanner instrument

Two Earth Radiation Budget Experiment (ERBE) nonscanner instruments are flying with companion scanner instruments to measure the earth's energy budget from low earth orbit. A third set of instruments will be launched in March 1986. This program is the first designed to make a comprehensive set of highly accurate measurements of the earth's energy budget on the spectral, spatial, and temporal scales specified by the scientific community for use in climatological research. The ERBE nonscanner combines the use of the highly accurate active cavity radiometer (ACR) detector with a comprehensive preflight calibration and characterization program and a design which includes operational flexibility and in-flight calibration checks to achieve and maintain, throughout its 2-year design life, a measurement accuracy capability not previously possible. This paper describes the ERBE nonscanner instrument, its operation, calibration, and mission profile.

Luther, M. R.↗

Glass-to-Metal Seal Against Liquid Helium

Simple compression joint with indium gasket forms demountable seal for superfluids. Seal developed for metal lid on glass jar used in experiments on liquid helium. Glass container allows contents to be viewed for such purposes as calibration of liquid-level detectors and adjustments of displacement plungers. Seal contains liquid helium even when temperature drops below 2.19K. Made from inexpensive, commercially available materials and parts.

Watkins, John L.↗

Compact X-Ray And Extreme-Ultraviolet Monochromator

Monochromator for x-ray and extreme-ultraviolet radiation provides higher spectral resolution than achieved with thin-metal-foil broad-band-pass filters. Uses Bragg reflection to band-pass-filter radiation from high-intensity, broad-spectrum source. Operates over much broader x-ray and extreme-ultraviolet spectrum than devices based upon natural crystals. Intended to filter continuum radiation from sources like synchrotrons, laser plasma sources, free-electron lasers, and wigglers to produce monochromatic beams for testing and analysis of x-ray and extreme-ultraviolet telescopes and microscopes, for calibration of photographic films and detectors, for biological and biomedical research, for x-ray lithography, for processing of materials, and for research in properties of materials.

Hoover, Richard B.↗

Light-heavy ion measurements in CR-39 located on the Earth side of LDEF

The azimuthal angle distribution and the charge and energy spectra of selected light-heavy (3 less than or = Z less than or = 8) stopping particles were measured in a single layer of CR-39 plastic nuclear track detector (PNTD) from the stack of the A0015 experiment located on the Earth-end of the satellite. The directional incidence of the trapped protons is studied by comparing the azimuthal angle distribution of selected recoils, obtained in the LDEF detectors, to that obtained through calibrations of PNTDs with exposure performed with 200 MeV proton beams from different directions. Similar measurements will be performed in a CR-39 sample exposed on the space-end of the LDEF satellite for intercomparison. The experimental results will also be compared to theoretical calculations.

Csige, I.↗

Light-heavy ion measurements in CR-39 located on the Earth side of LDEF

The azimuthal angle distribution and the charge and energy spectra of selected light-heavy (5 less than or equal to Z less than or equal to 8) stopping particles were measured in a single layer of CR-39 plastic nuclear track detector (PNTD) from the stack of the A0015 experiment located on the Earth-end of the LDEF satellite. The directional incidence of the trapped protons is studied by comparing the azimuthal angle distribution of selected recoils, obtained in the LDEF detectors, to that obtained through calibrations of PNTD's with exposures performed with 200 MeV proton beams from different directions.

Csige, I.↗

Detector noise statistics in the non-linear regime

The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

Shopbell, P. L.↗

Uses of continuum radiation in the AXAF calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Uses of Continuum Radiation in the AXAF Calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Radiometric Calibration of the NASA Advanced X-Ray Astrophysics Facility

We present the results of absolute calibration of the quantum efficiency of soft x-ray detectors performed at the PTB/BESSY beam lines. The accuracy goal is 1%. We discuss the implementation of that goal. These detectors were used as transfer standards to provide the radiometric calibration of the AXAF X-ray observatory, to be launched in April 1999.

Kellogg, Edwin M.↗

Progress in Using Continuum radiation for AXAF Calibration

X-ray calibration of the AXAF observatory at MSFC's X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis. Further verification of AXAF response models will be presented.

Kolodziejczak, J. J.↗

CGRO Cycle6

This is the final report covering the contract that supported several interrelated task. The first was the calibration of the BATSE SPECtroscopy detectors by comparison with known spectra. The second project was the installation and support of software to enable routine analysis of BATSE data. The third project was the support of several scientific investigations utilizing BATSE flare data.

Schwartz, Richard A.↗