Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Growth of Cd 0.9 Zn 0.1 Te 1-y Se y Single Crystals for Room Temperature Gamma-Ray Detection

Quaternary Cd 0.9 Zn 0.1 Te 1-y Sey (CZTS) single crystals, a novel room-temperature nuclear radiation detector semiconductor material, have been grown using a modified vertical Bridgman method (VBM) and a travelling heater method (THM). The percentage concentration of selenium in the VBM-grown crystal was 3% and that in the THM-grown crystal was 2%. While the THM Frisch collar detector (4.4 × 4.4 × 10.7 mm 3 ) produced a highly resolved pulse height spectra (PHS) with a resolution of ~1.06% for 662-keV gamma rays without any correction, the VBM-grown detector (10 × 10 × 2 mm 3 ) offered a high energy resolution of ~2% after application of a digital biparametric correction. The high-resolution performance of these detectors has been attributed to the addition of Se in the Cd 0.9 Zn 0.1 Te (CZT) matrix. Ab-initio calculations based on density functional theory (DFT) also confirmed that the addition of Se in the CZT matrix helps to reduce the formation of TeCd and the TeZn anti-sites. The VBM-grown crystals were characterized using powder x-ray diffraction (XRD) and energy dispersive x-ray spectroscopy (EDS). While XRD results revealed sharp diffraction peaks confirming the crystalline nature of the grown crystal, the EDS results confirmed the targeted stoichiometry of the elemental composition. The bulk resistivity of the grown crystal was calculated to be ~3 × 10 10 Ω-cm from current-voltage characteristics recorded at room temperature in a planar configuration, ensuring that the grown CZTS crystals have low dark current as required for detector-grade crystals.

42 ENGINEERING↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ptychographic phase retrieval by proximal algorithms

We derive a set of ptychography phase-retrieval iterative engines based on proximal algorithms originally developed in convex optimization theory, and discuss their connections with existing ones. The use of proximal operator creates a simple frame work that allows us to incorporate the effect of noise from a maximum-likelihood (ML) principle. We focus on three particular algorithms, namely proximal minimization, alternating direction method of multiplier and accelerated proximal gradient (APG). We benchmark their performance with numerical simulations, and discuss their optimal conditions for convergence and accuracy. An experimental dataset is used to demonstrate their effectiveness as well, in which case an array of cubic Au nanoparticles with a size of 50 nm is imaged. We show that with the presence of Poisson noise, a dataset with photon counts up to 10 4 at one detector pixel already requires ML-based methods to achieve a stable convergence. Among the three algorithms derived in this work, APG method is reported first time for its application in ptychographic reconstruction and shows superior performance in terms of both accuracy and convergence rate with a noisy dataset.

36 MATERIALS SCIENCE↗

Design of ePixM, a fully-depleted monolithic CMOS active pixel sensor for soft X-ray experiments at LCLS-II

The LCLS-II Free Electron Laser (FEL) will produce X-ray pulses with a repetition rate of up to 1 MHz and energies between 250 eV and 5 keV. Experiments conducted at LCLS-II will require 2D imaging detectors with a unique set of features, such as high-spatial resolution, low-noise performance, high-dynamic range and high-frame rates up to 1 MHz. We present the design of ePixM, a fully-depleted monolithic CMOS detector tailored for soft X-rays applications at high-repetition rates FEL. It consists of an array of 384×192 active pixel sensors, with a pixel size of 50×50 μm 2 and a total sensitive area of 2×1 cm 2 . ePixM has been designed in a 150 nm CMOS technology on high-resistivity substrate to achieve full depletion of the substrate. Each pixel includes a Charge Sensitive Amplifier (CSA) with gain auto-ranging capability and a noise-shaper performing Correlated Double Sampling (CDS). A novel technique named correlated pre-charging removes the excess noise introduced by the gain-switching mechanism. The performance of the design has been evaluated through post-layout simulations. The Equivalent Noise Charge (ENC) of 11.3 electrons enables single-photon detection at X-ray energies down to 250 eV, and the dynamic range exceeds 10 3 photons at 500 eV thanks to the auto-ranging circuitry.

47 OTHER INSTRUMENTATION↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interactions Observed Between Torus and Solenoid Superconducting Magnets at JLab

The Jefferson Lab 12 GeV Upgrade of Experimental End Station Hall B required a new detector system that would be more sensitive to forward going particles and able to handle higher luminosity. This new detector is CLAS12 and includes two superconducting iron-free magnets – a torus and an actively-shielded solenoid. The torus magnet consists of 6-trapezoidal racetrack-type coils while the solenoid is an actively shielded 5 T magnet. The torus and the solenoid are located in close proximity to one another and are surrounded by sensitive particle detectors. In this work, the torus and solenoid, operating at 3770 A and 2416 A respectively, were commissioned successfully and are operating normally. This paper presents observed electromagnetic interactions which include induced static mechanical loads and inductive coupling as well as a summary of some of the cryogenic interactions and how they are mitigated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-element balanced detector giving 65 dB CMRR at 30 MHz

We present a simple design for a single-element balanced detector (BD) that utilizes optical fibers in the sensing and reference channels with path length differences set to detect the differential signal at a desired frequency. With this approach, we easily achieve a common-mode rejection ratio of 65 dB, corresponding to the shot-noise limit of our setup. The CMRR demonstration is made in the MHz frequency range but could be extended to the kHz or GHz range. Using a single detector, the BD achieves stable CMRR over extended periods and does not require careful matching of detectors and amplification electronics. We demonstrate the single-element balanced detector design using the optical Kerr effect induced by a 30 MHz pulsed laser, showing a significant improvement over similar experiments using a commercial balanced detector.

Badilla-Nunez, Kelly [Georgia Institute of Technol↗

A pion-argon cross section measurement in the ProtoDUNE-SP experiment with cosmogenic muon

Neutrinos are tiny mysterious fundamental particles with small cross sections. Through neutrino physics, scientists across the world are trying to answer many intriguing questions about nature such as the dominance of matter over antimatter, CP violation in the lepton sector, number of supernovas in the early universe, etc. Detection of neutrinos requires massive particle detectors and intense neutrino beam owing to their small cross section. Deep Underground Neutrino Experiment (DUNE) is a next-generation neutrino experiment that is planned to start taking data beginning in 2026. DUNE will consist of 4 massive detectors, the first of which will be using single-phase liquid argon time projection chamber (LArTPC) technology. The ProtoDUNE-SP experiment is a prototype of the DUNE built at the CERN neutrino platform and uses the same detector technology that will be used in DUNE first module. The ProtoDUNE-SP experiment collected months of test beam and cosmic ray data beginning in September 2018. It was built to provide a testbed for the installation of detector parts for DUNE, showing long-term stability of the detector, understanding detector response for different test beam particles (including protons, pions, electrons, kaons, muons), and measurement of hadron-argon cross sections. When a particle passes through LArTPC electron-ion pairs are produced. To reconstruct the position and energy of a particle passing through the medium knowledge of ionization electron drift velocity is essential. The electron drift velocity is distorted by an excess positive charge built up in the detector, known as space charge. This study discusses a novel technique for measuring the ionization electron drift velocity using cosmic-ray muons. The technique uses tracks that travel the entire drift distance of the TPC for drift velocity determination. Secondly, the study discusses a method for converting the charge deposited into energy. The method is carried out in two step s. In th e first step detector response for energetic cosmic ray muons crossing the entire the TPC is used to make the charge deposition uniform throughout the TPC, and in the second step stopping cosmic-ray muons are used for determining the energy scale. Finally, the study discusses a pion-argon cross section measurement based on reweighting of Monte Carlo simulations using J. Calcutt's Geant4Reweight framework. Neutrinos cannot be directly detected; they are identified based on the interaction products. Pions are a common interaction product in a neutrino interaction. For precise modeling of neutrino event generators, it is essential to understand the pion-argon interaction. Pion-argon cross section measurement serves as an important input for neutrino interaction models. The results of the pion-argon total reaction cross section using the Geant4 reweighting technique are found to be in good agreement with Geant4 predictions. The many studies carried out in the ProtoDUNE-SP experi ment wil l be useful for current and future neutrino experiments using LArTPC technology including ICARUS, MicroBooNE, DUNE

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model.

47 OTHER INSTRUMENTATION↗

Extraction of Drell-Yan Angular Parameters in $pp$ Collisions with a 120 GeV Beam Energy Using a Deep-Learning Unfolding Algorithm

Dilepton production in pp collisions through the Drell-Yan process provides a crucial tool for studying the internal quark-gluon structure of the nucleon. By precisely measuring the $\cos2\phi$ asymmetry, where $\phi$ represents the azimuthal angle of the $l^{+}l^{-}$ pair in the Collins-Soper frame, we can gain valuable insights into the proton’s structure and the transverse momentum ($q_{T}$) dependence of the $\cos2\phi$ asymmetry. SeaQuest, a fixed-target Drell-Yan experiment at Fermilab, involved an unpolarized proton beam colliding with unpolarized LH$_{2}$ and LD$_{2}$ targets. Measurements obtained from experiments typically require corrections for detector inefficiencies, smearing, and acceptance. Traditionally, these corrections involve “unfolding” the detector-level measurements through matrix operations. However, in higher-dimensional phase space, these conventional methods fail to scale effectively. To overcome these limitations, we employ an unbinned unfolding method that utilizes deep neural networks for unfolding higher-dimensional phase space. In this presentation, we will explain the design of the neural network architecture, our training strategies, and outline our plans to achieve conclusive results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrastable reference pulser for high-resolution spectrometers

Solid-state double-pulse generator for a high resolution semiconductor detector meets specific requirements for resolution /0.05 percent/, amplitude range /0.1-13 MeV/, and repetition rate /0.1-1000 pulses per second/. A tag pulse is generated in coincidence with each reference pulse.

Brenner, R.↗

Low-noise video amplifiers for imaging CCD's

Various techniques were developed which enable the CCD (charge coupled device) imaging array user to obtain optimum performance from the device. A CCD video channel was described, and detector-preamplifier interface requirements were examined. A noise model for the system was discussed at length and laboratory data presented and compared to predicted results.

Scinicariello, F.↗

Infrared focal plane arrays for planetary missions

Requirements for infrared detector array focal planes suitable for a set of prospective planetary missions are developed. Using the Galileo mission to Jupiter as a starting point, objectives and constraints applicable to outer planet missions are developed. The concept for an advanced mapping spectrometer utilizing 128 x 128 element infrared detector arrays is described. Specific implementations for the Saturn Orbiter Dual Probe mission, a Mars Orbiter mission, and a Titan Orbiter mission are defined. The analysis indicates that within the 1 to 5 micron range, broad scientific objectives for these missions can be met using focal plane arrays with detectivities on the order of 10 to the 14th cm sq root of Hz per W. The realization of such high detectivities in a low background application will necessitate careful development of the method by which the detector signals are multiplexed and read out.

Wellman, J. B.↗

Near-infrared mapping spectrometer optical subsystem development and testing

The Near-Infrared Mapping Spectrometer (NIMS) is one of the four remote-sensing science instruments of the Galileo Orbiter scientific payload. The NIMS scientific objectives require operating the detector and optical subsystem at cryogenic temperatures. The necessity of assembling, aligning, and testing the optics at room temperature and meeting design specifications at the cryogenic operating temperature (130 K) presented a set of challenging technical problems. A systematic approach to the development of athermalized mounts and supporting structures for optical components is described. A technique utilizing the visible spectral range and supplementary ray-trace information for alignment of an infrared instrument is presented. The optical subsystem point-spread function and spatial and spectral resolution were determined at room temperature using selected spectral and spatial targets. Based on thermal-distortion analyses of the structure and mounts, compensators were selected, implemented, and verified at cryogenic temperatures. The selection of the compensator and the overall system performance were verified in a thermal vacuum chamber. Various external and internal calibration targets were used.

Macenka, S. A.↗

A payload to evaluate photodiodes for the detection of soft and hard x rays in a space environment using a Get Away Special

We propose to use the Get Away Special (GAS) facility to evaluate P-intrinsic-N (PIN) detectors and avalanche photodiodes (APD's) for the detection of both solar and nonsolar soft and hard x rays. We would like to fly both types of silicon detectors for the direct detection of the x ray photons in the energy range from 1 to 30 keV with an energy resolution of about 1 keV. We would also like to use both types of photodiodes viewing CsI(Tl) scintillators to extend the energy range up to 1 MeV with -6 percent resolution at 660 keV. Solar flares would be detected with this instrumentation during periods of solar pointing providing high energy resolution spectra with high time resolution. Similar data would be obtained in the scanning mode on nonsolar transient and steady x ray sources with the same instrumentation. A commandable door over the detectors would be required to allow measurements to be made as low as 1 keV.

Desai, Upendra D.↗

Instrumental and observational requirements for space-based imaging of magnetospheric emissions

Simulated images of extreme ultraviolet (EUV) emissions from energetic outflowing ions have been constructed to study techniques for remotely sensing the dynamic behavior of hot plasmas in the near-Earth environment. These calculations include realistic assumptions about the energetic ion outflow from high latitudes and take into account the effects of cold plasmaspheric and ionospheric ions. The energetic ion outflow is determined from a statistical study based on five years of measurements from the Energetic Ion Composition Spectrometer on Dynamics Explorer 1. The simulated images change significantly with viewing geometry and certain spacecraft locations are clearly favorable for observing emissions from energetic ions. For example, for a near equatorial orbit, viewing locations greater than 9 Earth radii are required to observe outflowing ions above the cold plasmaspheric background. We will discuss other important considerations for magnetospheric imaging including the sensitivity requirements of the detector. In particular, we consider the performance of multi-layer optics for EUV wavelengths.

Robinson, R. M.↗