On-Orbit Calibration and Performance Assessments of Terra and Aqua Modis Thermal Emissive Bands

Terra and Aqua MODIS have successfully operated for more than 20 and 18 years, respectively, and far exceeded their designed lifetimes of 6 years. MODIS has 36 spectral bands, among which 16 are the thermal emissive bands (TEB) covering a wavelength range from 3.75 to 14.24 μm. Observations from the MODIS TEB have been used to generate a number of data products, such as surface/cloud/atmospheric temperatures, cloud top altitude, and water vapor properties. To a large extent, the quality of the MODIS L1B radiance product has been maintained through the entirety of each mission via extensive on-orbit calibration and validation efforts. MODIS TEB calibration uses a quadratic algorithm and is referenced to an on-board blackbody with its temperature measurements traceable to the NIST standard. We provide an overview of the MODIS instrument operations, key TEB calibration activities, and algorithms used in the latest L1B data Collection 6.1 (C6.1) and describe the TEB on-orbit performance for both Terra and Aqua MODIS. The TEB gain trends have been stable to within 5% over the Terra mission after 2003 under the same electronic configuration, except for bands 27 to 30, and within 3% over the Aqua mission. The Terra MODIS optical crosstalk correction implemented right after launch has been very effective in removing the ghost images in its photoconductive detector bands 32 to 36. Starting from C6.1, an electronic crosstalk correction algorithm has also been applied to the Terra MODIS photovoltaic detector long-wave infrared bands 27 to 30. The noise characterization performance remains stable with most TEB detectors continuously meeting their design requirements. A gradual loss of the Aqua MODIS radiative cooler margin reached its maximum in 2013 and has been slowly recovering since then. On-orbit changes in TEB response versus scan angle are extremely small based on pitch maneuver observations and assessments using vicarious approaches. The remaining challenges in TEB calibration and proposed improvements for the upcoming data collection with L1B data production and reprocessing are discussed.

Terra↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

Few-Mode Fiber Coupled Superconducting Nanowire Single-Photon Detectors for Photon Efficient Optical Communications

The NASA Glenn Research Center's development of a high-photon efficiency real-time optical communications ground receiver has added superconducting nanowire single-photon detectors (SNSPDs) coupled with few-mode fibers (FMF). High data rate space-to-ground optical communication links require enhanced ground receiver sensitivity to reduce spacecraft transmitter constraints, and therefore require highly efficient coupling from fiber to detector. In the presence of atmospheric turbulence the received optical wave front can be severely distorted introducing higher-order spatial mode components to the received signal. To reduce mode filtering and mismatch loss and the resulting degradations to detector coupling efficiency, we explore the use of few-mode fiber coupling to commercial single-pixel SNSPDs. Graded index 20-µm few-mode fibers allow the commercial single pixel SNSPD's active area to couple with equal efficiency as single mode fibers. Here we determine detector characteristics such as count rate, detection efficiency, dark counts, and jitter, as well as detection efficiencies for higher-order fiber spatial modes. Additionally, we assess the laboratory performance of the detectors in an optical system which emulates future deep space optical communications links.

Vyhnalek, Brian E.↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

Float zone silicon for IR detectors

An overview of the state of the art of processing silicon for use as infrared detectors is presented. Improvements in the process that could be obtained in a low-g environment were examined. The various requirements for the different types of Si detector materials are summarized.

Kern, E. L.↗

Design Improvements and X-Ray Performance of a Time Projection Chamber Polarimeter for Persistent Astronomical Sources

The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.

GEMS↗

Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

Millimeter-Wave Detectors↗

Predicting Chandra CCD Degradation with the Chandra Radiation Model

Not long after launch of the Chandra X-Ray Observatory, it was discovered that the Advanced CCD Imaging Spectrometer (ACIS) detector was rapidly degrading due to radiation. Analysis by Chandra personnel showed that this degradation was due to 10w energy protons (100 - 200 keV) that scattered down the optical path onto the focal plane. In response to this unexpected problem, the Chandra Team developed a radiation-protection program that has been used to manage the radiation damage to the CCDs. This program consists of multiple approaches - scheduled sating of the ACIS detector from the radiation environment during passage through radiation belts, real-time monitoring of space weather conditions, on-board monitoring of radiation environment levels, and the creation of a radiation environment model for use in computing proton flux and fluence at energies that damage the ACIS detector. This radiation mitigation program has been very successful. The initial precipitous increase in the CCDs' charge transfer inefficiency (CTI) resulting from proton damage has been slowed dramatically, with the front-illuminated CCDS having an increase in CTI of only 2.3% per year, allowing the ASIS detector's expected lifetime to exceed requirements. This paper concentrates on one aspect of the Chandra radiation mitigation program, the creation of the Chandra Radiation Model (CRM). Because of Chandra's highly elliptical orbit, the spacecraft spends most of its time outside of the trapped radiation belts that present the severest risks to the ACIS detector. However, there is still a proton flux environment that must be accounted for in all parts of Chandra's orbit. At the time of Chandra's launch there was no engineering model of the radiation environment that could be used in the outer regions of the spacecraft's orbit, so the CRM was developed to provide the flux environment of 100 - 200 keV protons in the outer magnetosphere, magnetosheath, and solar wind regions of geospace. This presentation describes CRM, its role in Chandra operations, and its prediction of the ACIS CTI increase.

Minow, Joseph I.↗

(abstract) 9 (micro)m Cutoff 640x480 Quantum Well Infrared Photodetector (QWIP) Focal Plane Array Camera

Long wavelength infrared (LWIR) detectors, 8 (micro)m to 12 (micro)m, are of great interest for a variety of ground-based and space-borne applications. These applications have placed stringent requirements on the performance of the infrared detectors and arrays including high detectivity, low dark current, uniformity, radiation hardness, and low power dissipation. I will discuss the development and progress of GaAs based long-wavelength quantum well infrared photodetectors (QWIPs) to meet those stringent requirements and the demonstration of a 9 (micro)m cutoff 640x480 QUIP focal plane array camera. The noise equivalent temperature difference of the focal plane array is 25 mK at 300 K background and the operating temperature is 70 K.

long wavelength infrared detectors LWIR detector a↗

Monte Carlo Simulations of the Response of the MARIE Instrument

The MARIE instrument aboard Mars Odyssey functions as a telescope for the detection of charged, energetic, nuclei. The directionality that leads to the telescope description is achieved by requiring coincident signals in two designated detectors in MARIE s silicon detector stack for the instrument to trigger. Because of this, MARIE is actually a bi directional telescope. Triggering particles can enter the detector stack by passing through the lightly shielded front of the instrument, but can also enter the back of the instrument by passing through the bulk of Odyssey. Because of this, understanding how to relate the signals recorded by MARIE to astrophysically important quantities such as particle fluxes or spectra exterior to the spacecraft clearly requires detailed modeling of the physical interactions that occur as the particles pass through the spacecraft and the instrument itself. In order to facilitate in the calibration of the MARIE data, we have begun a program to simulate the response of MARIE using the FLUKA [1] [2] Monte Carlo radiation transport code.

Andersen, V.↗

NASA Office of Aeronautics and Space Technology Summer Workshop. Volume 10: Basic research panel

Possible research experiments using the space transportation system are identified based on user requirements. Opportunity driven research areas include quantum electronics, cryogenics system technology, superconducting devices and detectors, and photo-induced reactions. Mission driven research requirements were examined and ranked based on inputs from the user group.

Source record↗

Cryogenic cooling study for the advanced limb scanner

The cryogenic operating requirements for a VM refrigerator to be used for detector cooling of the advanced limb scanner (ALS) instrument are defined. Determination of these requirements include consideration of mission and environmental constraints. Based on the operating requirements a detailed refrigerator design and performance analysis is conducted resulting in an optimized VM refrigerator conceptual design. The cooler-instrument-spacecraft interfaces are evaluated resulting in recommendations as to the best approach and most effective concepts resulting in simple and satisfactory interfaces. A preliminary implementation plan and schedule describing the general tasks required to develop, design, manufacture, test, and deliver three VM coolers and required support equipment to support an ALS flight experiment are presented. The result of this effort shows that existing VM cooler technology is sufficient to satisfy ALS mission requirements and schedules.

Russo, S. C.↗

CCSDS File Delivery Protocol (CFDP): Why it's Useful and How it Works

Reliable delivery of data products is often required across space links. For example, a NASA mission will require reliable delivery of images produced by an on-board detector. Many missions have their own (unique) way of accomplishing this, requiring custom software. Many missions also require manual operations (e.g. the telemetry receiver software keeps track of what data is missing, and a person manually inputs the appropriate commands to request retransmissions). The Consultative Committee for Space Data Systems (CCSDS) developed the CCSDS File Delivery Protocol (CFDP) specifically for this situation. CFDP is an international standard communication protocol that provides reliable delivery of data products. It is designed for use across space links. It will work well if run over the widely used CCSDS Telemetry and Telecommand protocols. However, it can be run over any protocol, and will work well as long as the underlying protocol delivers a reasonable portion of the data. The CFDP receiver will autonomously determine what data is missing, and request retransmissions as needed. The CFDP sender will autonomously perform the requested transmissions. When the entire data product is delivered, the CFDP receiver will let the CFDP sender know that the transaction has completed successfully. The result is that custom software becomes standard, and manual operations become autonomous. This paper will consider various ways of achieving reliable file delivery, explain why CFDP is the optimal choice for use over space links, explain how the core protocol works, and give some guidance on how to best utilize CFDP within various mission scenarios. It will also touch on additional features of CFDP, as well as other uses for CFDP (e.g. the loading of on-board memory and tables).

Ray, Tim↗

Particle background effects for Hubble Space Telescope (HST) and the Lyman Far Ultraviolet Spectroscopic Explorer

Requirements on orbital background counting rates are described for the UV and visible detectors on the planned second generation instrument Space Telescope Imaging Spectrograph (STIS) and for the proposed Lyman Far Ultraviolet Spectroscopic Explorer. Expected background rates and shielding requirements are analyzed for detector types in both instruments for low earth orbits, and for high orbits in the case of Lyman.

Woodgate, B. E.↗

Intraband Radiometric Performance of the LANDSAT 4 Thematic Mapper

Those radiometric characteristics of the LANDSAT 4 thematic mapper (TM) that could be established without absolute calibration of spectral data were examined. Radiometrically raw (B type) data of three daytime and two nighttime scenes were used, including TM scenes from Washington, DC; northeast Arkansas; Cape Cod, MA; Roanoke, VA; Richmond, VA; and Silver Bell, AZ. The effective resolution in radiance is degraded by a factor of about 2 by the irregular width of the digital levels. Underpopulated levels are consistent over all bands and detectors, and are spaced an average of 4 digital numbers (DN) apart. In band 6, level 127 is avoided by a factor 30. Several detectors exhibit a change of gain with a period of several scans; the largest effect is about 4%. At high contrast boundaries, some of the detectors in band 5 commonly overshoot by several DN and require about 30 samples to recover. The high frequency noise level of each detector was characterized by the standard deviation of the first derivative in the sample direction across a flat field. A coherent-sinusoidal-noise pattern is evident in detector 1 of band 3. The correlation between the six reflective bands was determined and used to select three groups of bands whose aggregate first principal components contain the greatest total information. A composite of the first components of bands 1, 2, 3, bands 5 and 7, and band 4, together containing 89% of the information in the reflectance bands, has reduced the effect of noise.

Kieffer, H. H.↗

Atmosphere monitoring requirements

Atmospheric monitoring needs and requirements associated with the use of the Mass Spectrometer Electro-Optical Ion Detector for space stations contamination studies are discussed. Instrument performance requirements and design specifications are examined. A general overview is presented of the types of chemical contaminants found in spacecraft environments.

Ruecker, M.↗

The hidden ion population of the magnetosphere

The presence of a cold ion population in the magnetosphere which is normally hidden from particle detector observation by the positive charging of the spacecraft is reported. Ion and electron data were obtained from particle detectors on the ATS 6 and SCATHA satellites designed to measure the 1-eV to 80-keV plasma population. The cold, isotropic ion population, with temperature 1 eV and density 10-100/cu cm, was detected only when the spacecraft were in eclipse, when spacecraft potential had dropped from +10 V in sunlight to +4 to +5 V. The hidden ion population was found at geosynchronous altitude only during geomagnetically quiet times and when there has been an absence of geomagnetic activity for several hours, and appears to coexist with the plasma sheet. More consistent measurements of the cold ion population at midnight or at other local times would require the biasing of the ion detector with respect to the spacecraft, or the controlling of spacecraft potential.

Olsen, R. C.↗

Methods of Optimizing X-Ray Optical Prescriptions for Wide-Field Applications

We are working on the development of a method for optimizing wide-field x-ray telescope mirror prescriptions, including polynomial coefficients, mirror shell relative displacements, and (assuming 4 focal plane detectors) detector placement and tilt that does not require a search through the multi-dimensional parameter space. Under the assumption that the parameters are small enough that second order expansions are valid, we show that the performance at the detector surface can be expressed as a quadratic function of the parameters with numerical coefficients derived from a ray trace through the underlying Wolter I optic. The best values for the parameters are found by solving the linear system of equations creating by setting derivatives of this function with respect to each parameter to zero. We describe the present status of this development effort.

Elsner, R. F.↗