Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototype Development for MBSE-Driven Digital Environment at Fermilab

Complex projects like Fermilab s accelerators and detectors involve thousands of interdependent components and requirements, making traditional documentation hard to keep consistent and often causing rework. Model-Based Systems Engineering (MBSE) tackles this by representing the system as a digital, queryable model. While widely used in aerospace and safety-critical industries, MBSE adoption has been limited elsewhere due to steep learning curves and high costs. This project investigates how a web-first, low-code MBSE stack can reduce those barriers and offer an accessible, unified source of truth for engineers and physicists.

Valle, Diego Pedro (ORCID:0009000865900663)↗

Proposal from the NA61/SHINE Collaboration for update of European Strategy for Particle Physics

Building on the current program's success and driven by new physics challenges, the NA61/SHINE Collaboration proposes to continue measuring hadron production properties in reactions induced by hadron and ion beams after CERN Long Shutdown 3. These measurements are of significant interest to the heavy-ion, cosmic-ray, and neutrino physics communities and will focus on: - Investigating hadron production in the light-ion systems to explore the diagram of high-energy nuclear collisions, and to obtain new insight into the unexpected violation of isospin (flavor) symmetry recently observed by the experiment; - Measuring charm-anticharm correlations to gain unique insights into the production locality of charm and anticharm quark pairs; - Examining strangeness and multi-strangeness production to improve our understanding of the early Universe's evolution and neutron star formation; - Measuring cross sections relevant for cosmic-ray measurements, significantly boosting searches for new physics in our Galaxy; - Conducting hadron production measurements with proton, pion, and kaon beams for neutrino physics, enhancing the precision of hadron production data needed for initial neutrino flux predictions in neutrino oscillation experiments; - Measuring hadron production processes relevant for understanding the flux of atmospheric neutrinos, as well as neutrinos and muons from spallation sources. To achieve these objectives, a detector upgrade and a beam upgrade are required, with data-taking planned for the period 2029-2032 and beyond.

Adhikary, H. [Jan Kochanowski U.] (ORCID:000000025↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurements of Differential Cross Sections In Kinematic Imbalance Variables With The MicroBooNE Detector

Making high-precision measurements of neutrino oscillation parameters requires an unprecedented understanding of neutrino-nucleus scattering. In this presentation, we present the first muon neutrino charged current double-differential cross sections in kinematic imbalance variables. These variables characterize the imbalance in the plane transverse to an incoming neutrino. We use events with a single muon above 100 MeV/c, a single final state proton above 300 MeV/c, and no recorded final state pions. Thus, these variables act as a direct probe of nuclear effects such as final state interactions, Fermi motion, and multi-nucleon processes. We also present a complementary ongoing analysis using electron neutrinos. This channel is of the utmost importance for the extraction of neutrino oscillation parameters by making high-precision measurements. Our measurements allow us to constrain systematic uncertainties associated with neutrino oscillation results performed by near-future experiments of the Short Baseline Neutrino (SBN) program, as well as by future large-scale experiments like DUNE.

43 PARTICLE ACCELERATORS↗

Elimination LArTPC Simulation Uncertainty With Modifcations to TPC Wire Waveforms

This paper introduces a novel approach to reducing systematic uncertainties in LArTPC detector simulations, which arise from known detector effects that are challenging and computationally intensive to model. The proposed method involves modifying simulated waveforms based on observed discrepancies in ionization signals from the TPC between actual data and simulations. This approach reduces the sensitivity to detailed detector modeling and decreases the computational resources required for accurate simulations.

Mktchyan, Karen↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection efficiency of the Neutron dEtector with Xn Tracking (NEXT)

An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where β-delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking (NEXT) has been designed to measure β-delayed neutron emitters. By segmenting the detector along the neutron flight path, NEXT reduces the associated uncertainties in neutron time-of-flight measurements, improving energy resolution while maintaining detection efficiency. Detector prototypes are comprised of optically separated segments of a neutron-gamma discriminating plastic scintillator coupled to position-sensitive photomultiplier tubes. In this work we discuss how the first performance studies of this detector showed that high intrinsic neutron detection efficiency could be achieved while retaining good energy resolution. The results from the efficiency measurements using neutrons from direct reactions are presented

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Optical leakage mitigation in ortho-mode transducer detectors for microwave applications

Ortho-mode transducers (OMT) are a commonly used method of coupling opti-cal signals between waveguides and on-chip circuitry and detectors. While the ideal OMT-waveguide coupling requires minimal disturbance to the waveguide, when used for mm-wave applications the waveguide is often slide though and the OMT probes inserted on a thin support membrane. This interface is a potential source of signal leakage and can lead to signal loss and experimental systematics (e.g. in CMB polarization experiments where lost signal can result in temperature to polarization leakage). Here we report on the development of new OMT- waveguide coupling structures with the goal of reducing leakage at the horn-to-detector-wafer interface. The pixel to pixel optical leakage due to the gap be-tween the coupling waveguide and the backshort is reduced by means of a protrusion that passes through the OMT membrane and connects the waveguide sections on each side of the wafer. High frequency electromagnetic simulations indicate that these protrusions can reduce optical leakage in the gap by ~80% percent, with a ~60% filling factor, respect to an ordinary OMT coupling without protrusion, using designs that are compatible with current fabrication processes. We describe the design of the new coupling structure including the impact of varying two key parameters: wafer to optical coupling gap and protrusion fill factor. Prototype devices have been designed that will characterize the performance of the new design using a relative measurement with varying filling factors. We describe the simulation setup and results, and present a chip layout and sample box designed to perform an initial measurement.

Detectors↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis of CdZnTeSe single crystals for room temperature radiation detector fabrication: mitigation of hole trapping effects using a convolutional neural network

In this article, we report the growth of Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) wide bandgap semiconductor single crystals for room temperature gamma-ray detection using a modified vertical Bridgman method. Charge transport properties measured in the radiation detectors, fabricated from the grown CZTS crystals, indicated signs of hole trapping. Hole traps inhibit high-resolution radiation detection especially for energetic gamma rays. Machine learning (ML) applications are gaining tremendous mpetus in improving device and sensor performance by compensating for limi tations arising from such intrinsic material properties. In this article, we describe a deep convolutional neural network (CNN) that has demonstrated remarkable efficiency in identifying the energy of a gamma photon detected by a CZTS detector. The CNN has been trained using simulated data that resemble output pulses from actual CZTS detectors when exposed to 662-keV gamma photons. The device properties required for the simulation have been derived from radiation detection measurements on a real Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 detector fabricated in our laboratory. The CNN has been trained with detector pulses arising through photoelectric (PE) and Compton scattering (CS) separately. The percentage error in predicting the detected energies, within an extremely small duration of 0.28 ms, was found to be lower than 0.1% for gamma energies above 50 keV and for training datasets con taining PE and CS events separately. The CNN was also validated for a mixed PE and CS dataset to obtain a prediction error of 1%. Additionally, the effect of detector resolution on the efficiency of the CNN was also explored.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Status of the DUNE experiment

The Deep Underground Neutrino Experiment aims at an unprecedentedly precise neutrino CPviolation phase measurement with a broad-band muon neutrino and antineutrino beam, a 1,300 km baseline, an order of 10skt fiducial mass detector with high particle identification efficiency and low external background.Additionally, the orders of systematic uncertainty should be constrained to 2% for the signal and5% for the background. This uncertainty constraint requires an unprecedented level of robustnessand redundancy in the near detector measurement. In this presentation, the near detector designand the far detector prototyping status are shown. The long-baseline sensitivity and differentphysics potentials are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Neutrino interaction vertex reconstruction in DUNE with Pandora deep learning

The Pandora Software Development Kit and algorithm libraries perform reconstruction of neutrino interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at the Deep Underground Neutrino Experiment, which will operate four large-scale liquid argon time projection chambers at the far detector site in South Dakota, producing high-resolution images of charged particles emerging from neutrino interactions. While these high-resolution images provide excellent opportunities for physics, the complex topologies require sophisticated pattern recognition capabilities to interpret signals from the detectors as physically meaningful objects that form the inputs to physics analyses. A critical component is the identification of the neutrino interaction vertex. Subsequent reconstruction algorithms use this location to identify the individual primary particles and ensure they each result in a separate reconstructed particle. A new vertex-finding procedure described in this article integrates a U-ResNet neural network performing hit-level classification into the multi-algorithm approach used by Pandora to identify the neutrino interaction vertex. The machine learning solution is seamlessly integrated into a chain of pattern-recognition algorithms. The technique substantially outperforms the previous BDT-based solution, with a more than 20% increase in the efficiency of sub-1 cm vertex reconstruction across all neutrino flavours.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗