Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Hemispherical Field-of-View Above-Water Surface Imager for Submarines

A document discusses solutions to the problem of submarines having to rise above water to detect airplanes in the general vicinity. Two solutions are provided, in which a sensor is located just under the water surface, and at a few to tens of meter depth under the water surface. The first option is a Fish Eye Lens (FEL) digital-camera combination, situated just under the water surface that will have near-full- hemisphere (360 azimuth and 90 elevation) field of view for detecting objects on the water surface. This sensor can provide a three-dimensional picture of the airspace both in the marine and in the land environment. The FEL is coupled to a camera and can continuously look at the entire sky above it. The camera can have an Active Pixel Sensor (APS) focal plane array that allows logic circuitry to be built directly in the sensor. The logic circuitry allows data processing to occur on the sensor head without the need for any other external electronics. In the second option, a single-photon sensitive (photon counting) detector-array is used at depth, without the need for any optics in front of it, since at this location, optical signals are scattered and arrive at a wide (tens of degrees) range of angles. Beam scattering through clouds and seawater effectively negates optical imaging at depths below a few meters under cloudy or turbulent conditions. Under those conditions, maximum collection efficiency can be achieved by using a non-imaging photon-counting detector behind narrowband filters. In either case, signals from these sensors may be fused and correlated or decorrelated with other sensor data to get an accurate picture of the object(s) above the submarine. These devices can complement traditional submarine periscopes that have a limited field of view in the elevation direction. Also, these techniques circumvent the need for exposing the entire submarine or its periscopes to the outside environment.

Hemmati, Hamid↗

Osteogenic Transcription Regulated by Exaggerated Stretch Loading via Convergent Wnt Signaling

Cell and animal studies conducted onboard the International Space Station and formerly the Shuttle flights have provided data illuminating the deleterious biological response of bone to mechanical unloading. Down regulation of proliferative mechanisms within stem cell populations of the osteogenic niche is a suggested mechanism for loss of bone mass. However the intercellular communicative cues from osteoblasts and osteocytes in managing stem cell proliferation and osteogenic differentiation are largely unknown. In this investigation, MLO-Y4 osteocyte-like and MC3T3-E1 osteoblast-like cells, are co-culture under dynamic tensile conditions and evaluated for phenotypic expression of biochemical signaling proteins influential in driving stem cell differentiation. MLO-Y4 and MC3T3-E1 were co-cultured on polyethersulfone membrane with a 0.45m porosity to permit soluble factor transfer and direct cell-cell gap junction signaling. Cyclic tensile stimulation was applied for 48 h at a frequency of 0.1Hz and strain of 0.1. Total Live cell counts indicate mechanical activation of MC3T3-E1s inhibits proliferation while MLO-Y4s increase in number. However, the percent of live MLO-Y4s within the population is low (46.3 total count, *p0.05, n4) suggesting a potential apoptotic signaling cascade. Immunofluorescence demonstrated that stimulation of co-cultures elicits increased gap junction communication. Previously reported PCR evaluation of osteogenic markers further corroborate that the co-cultured populations communicative networks play a role in translating mechanical signals to molecular messaging. These findings suggest that an osteocyte-osteoblast signaling feedback mechanism may regulate mechanotransduction of an apoptotic cascade within osteocytes and transcription of cytokine signaling proteins responsible for stem cell niche recruitment much more directly than previously believed.

mechanical stimulation↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Dual laser gyro test program

This paper addresses the results of a comparative test evaluation of two similar-sized but otherwise dissimilar ring laser gyroscopes (RLG's). Both units were tested side by side, with the input axes (IA's) parallel, on the same test table. This report describes the rationale and design factors considered important to the test objectives. Emphasis was placed upon the evaluation of the scale factor (SF) linearity, drift rate stability (short term and long term), and derived rate. Conclusions drawn were (1) that dual operation had an observable but insignificant effect on the test results, (2) that the benefits of dual operation outweighed the additional design and analysis efforts required at the outset of the program, and (3) that the performance characteristics of the two test articles were significantly different. The differences between the two test articles (1) led to suggestions which could direct one vendor toward obtaining improved performance and (2) resulted in the creation of a conceptually new method (DELTA TIME-COUNT histogram) for quickly assessing the quality of laser gyros (or any digital sensor device for that matter).

Jones, Malcolm E.↗

Exact computation of the unwrapped phase of a finite-length time series

McGowan and Kuc (1982) showed that a direct relationship between a time series and its unwrapped phase exists. They proposed an algorithm for computing the unwrapped phase by counting the number of sign changes in a Sturm sequence generated from the real and imaginary parts of the discrete Fourier transform. Their algorithm is limited to relatively short sequences by numerical accuracy. An extension of their algorithm is proposed which, by using all-integer arithmetic, permits exact computation of the number of multiples of pi required to determine the unwrapped phase for rational-valued time sequences of arbitrary length. Since the computation is exact, the extended numerical algorithm should be of interest when accurate phase unwrapping is required.

Long, David G.↗

Advanced Dependent Pressure Vessel (DPV) nickel-hydrogen spacecraft cell and battery design

The dependent pressure vessel (DPV) nickel-hydrogen (NiH2) battery is being developed as a potential spacecraft battery design for both military and commercial satellites. Individual pressure vessel (IPV) NiH2 batteries are currently flying on more than 70 Earth orbital satellites and have accumulated more than 140,000,000 cell-hours in actual spacecraft operation. The limitations of standard NiH2 IPV flight battery technology are primarily related to the internal cell design and the battery packaging issues associated with grouping multiple cylindrical cells. The DPV cell design offers higher specific energy and reduced cost, while retaining the established IPV NiH2 technology flight heritage and database. The advanced cell design offers a more efficient mechanical, electrical and thermal cell configuration and a reduced parts count. The internal electrode stack is a prismatic flat-plate arrangement. The flat individual cell pressure vessel provides a maximum direct thermal path for removing heat from the electrode stack. The cell geometry also minimizes multiple-cell battery packaging constraints by using an established end-plateltie-rod battery design. A major design advantage is that the battery support structure is efficiently required to restrain only the force applied to a portion of the end cell. As the cells are stacked in series to achieve the desired system voltage, this increment of the total battery weight becomes small. The geometry of the DPV cell promotes compact, minimum volume packaging and places all cell terminals along the length of the battery. The resulting ability to minimize intercell wiring offers additional design simplicity and significant weight savings. The DPV battery design offers significant cost and weight savings advantages while providing minimal design risks. Cell and battery level design issues will be addressed including mechanical, electrical and thermal design aspects. A design performance analysis will be presented at both the cell and battery level. The DPV is capable of delivering up to 76 Watt-hours per kilogram (Wh/kg) at the cell level and 70 Wh/kg at the full battery level. This represents a 40 percent increase in specific energy at the cell level and a 60 percent increase in specific energy at the battery level compared to current IPV NiH2 technology.

Coates, Dwaine↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

The solution of linear systems of equations with a structural analysis code on the NAS CRAY-2

Two methods for solving linear systems of equations on the NAS Cray-2 are described. One is a direct method; the other is an iterative method. Both methods exploit the architecture of the Cray-2, particularly the vectorization, and are aimed at structural analysis applications. To demonstrate and evaluate the methods, they were installed in a finite element structural analysis code denoted the Computational Structural Mechanics (CSM) Testbed. A description of the techniques used to integrate the two solvers into the Testbed is given. Storage schemes, memory requirements, operation counts, and reformatting procedures are discussed. Finally, results from the new methods are compared with results from the initial Testbed sparse Choleski equation solver for three structural analysis problems. The new direct solvers described achieve the highest computational rates of the methods compared. The new iterative methods are not able to achieve as high computation rates as the vectorized direct solvers but are best for well conditioned problems which require fewer iterations to converge to the solution.

Poole, Eugene L.↗

High Spectral Resolution, High Cadence, Imaging X-Ray Microcalorimeters for Solar Physics

High spectral resolution, high cadence, imaging x-ray spectroscopy has the potential to revolutionize the study of the solar corona. To that end we have been developing transition-edge-sensor (TES) based x-ray micro calorimeter arrays for future solar physics missions where imaging and high energy resolution spectroscopy will enable previously impossible studies of the dynamics and energetics of the solar corona. The characteristics of these x-ray microcalorimeters are significantly different from conventional micro calorimeters developed for astrophysics because they need to accommodate much higher count rates (300-1000 cps) while maintaining high energy resolution of less than 4 eV FWHM in the X-ray energy band of 0.2-10 keV. The other main difference is a smaller pixel size (less than 75 x 75 square microns) than is typical for x-ray micro calorimeters in order to provide angular resolution less than 1 arcsecond. We have achieved at energy resolution of 2.15 eV at 6 keV in a pixel with a 12 x 12 square micron TES sensor and 34 x 34 x 9.1 micron gold absorber, and a resolution of 2.30 eV at 6 keV in a pixel with a 35 x 35 micron TES and a 57 x 57 x 9.1 micron gold absorber. This performance has been achieved in pixels that are fabricated directly onto solid substrates, ie. they are not supported by silicon nitride membranes. We present the results from these detectors, the expected performance at high count-rates, and prospects for the use of this technology for future Solar missions.

Bandler, Simon R.↗

Cloud Microphysics in Hurricane Outflows: Observations in 'Bonnie' (1998) at 12 km Altitude

The water balance of a hurricane is controlled by boundary layer inflow, near vertical motion in the eyewall causing coalescence precipitation at above and residual ice precipitation at below freezing temperatures, and cirrus outflow at below -40 C aloft. In this paper we address the question of efficiency of water removal by this cirrus outflow which is important for the release of latent heat at high altitudes and its role in the dynamic flow at that level. During NASA's 1998 Convection and Moisture Experiment campaign we acquired microphysical outflow data in order to (1) determine the release and redistribution of latent heat near the top of hurricanes, (2) aid in TRMM algorithm development for remote sensing of precipitation, and (3) determine the optical/radiative characteristics of hurricane outflow. The data were acquired with Particle Measuring Systems two dimensional imaging spectrometers. On 23 August and again during the hurricane's landfall on 26 August, 1998, the NASA DC-8 aircraft penetrated hurricane 'Bonnie' four times each near 200 hPa pressure altitude. The eye crossing times were determined by (1) zero counts of cloud particles, (2) approximately 5 C increases in static and potential temperatures, and (3) minima in speeds and changes of direction of horizontal winds. The vertical winds showed shear between -6 m per second and +4 m per second and tangential winds approached 30 m per second in the eyewall. The particle volumes in the eyewall (determined by the pixels the particles shadowed in the direction of flight [x-direction] and normally to it by the number of diodes that they shadowed [y-direction]) ranged between 0.5 and 5.0 cubic centimeters per cubic meter. With a particle density near 0.2 g per cubic centimeter (determined from in situ melting and evaporation on a surface collector), the 1.0 g per meter corresponding mass of cloud ice ranged between 0.27 and 2.7 g per kilograms yielding horizontal fluxes between 8.1 and 81 g per square meters per second. The outflow ice was concentrated in crystals of a modal size of 190 micrometers. The particle size distributions were heavily skewed toward sizes with 98% of all cirrus particles smaller than the modal size comprising, however, only 20% of the mass. Thus the smaller than modal size particles dominantly affected the optical/radiative characteristics of the cloud, whereas the larger than modal size crystals determined the ice mass, hence dominated latent heating. Questions to be addressed relate to the origin of individual ice particles as the hurricane evolved and the likelihood of pristine and aggregate particle formation under the complicated conditions of rotation and outflow in the eyewall.

Pueschel, Rudolf F.↗

Cursor Control Device Test Battery

The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not include all of the underlined characters, or includes non-underlined characters, it is recorded as an error. Task 6, Multi-size and Multi-distance Pointing, presents the participant with 24 consecutively numbered buttons of different sizes (63 to 163 pixels), and at different distances (60 to 80 pixels) from the Start button. The task is to click on the Start button, and then move directly to, and click on, each numbered target button in consecutive order. Clicks outside of the target area are errors. Task 7, Standard Interface Elements Task, involves interacting with standard interface elements as instructed in written procedures, including: drop-down menus, sliders, text boxes, radio buttons, and check boxes. Task completion time is recorded. In Task 8, a circular track is presented with a disc in it at the top. Track width and disc size are adjustable. The task is to move the disc with circular motion within the path without touching the boundaries of the track. Time and errors are recorded. Task 9 is a discrete task that allows evaluation of discrete cursor control devices that tab from target to target, such as a castle switch. The task is to follow a predefined path and to click on the yellow targets along the path.

Kritina Holden↗

Optical Array Versus Monolithic Telescope Ground Station Cost Assessment

The purpose of this study is to outline the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope in support of deep-space communications. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link. The design is approached from a practical, engineering perspective. Pulse position modulation (PPM) signal formatting and photon counting detectors are assumed at each telescope in the array. That is, the telescopes function as so-called light buckets, so direct detection (as opposed to coherent reception) of the received signals is assumed, and there is no intention to consider active compensation for atmospheric turbulence-induced phase fluctuations. A parametric analysis among aperture size, detector size, and primary mirror surface quality, in the context of field-of-view expansion, is presented to minimize the cost function.

Romanofsky, Robert R.↗

ATP as a biomarker of viable microorganisms in clean-room facilities

A new firefly luciferase bioluminescence assay method that differentiates free extracellular ATP (dead cells, etc.) from intracellular ATP (viable microbes) was used to determine the viable microbial cleanliness of various clean-room facilities. For comparison, samples were taken from both clean-rooms, where the air was filtered to remove particles >0.5 microm, and ordinary rooms with unfiltered air. The intracellular ATP was determined after enzymatically degrading the sample's free ATP. Also for comparison, cultivable microbial populations were counted on nutrient-rich trypticase soy agar (TSA) plates. Both the cultivable and ATP-based determinations indicate that the microbial burden was lower in clean-room facilities than in ordinary rooms. However, there was no direct correlation between the two sets of measurements because the two assays measured very different populations. A large fraction of the samples yielded no colony formers on TSA, but were positive for intracellular ATP. Subsequently, genomic DNA was isolated directly from selected samples and 16S rDNA fragments were cloned and sequenced, identifying nearest neighbors, many of which are known to be noncultivable in the media employed. It was concluded that viable microbial contamination can be reliably monitored by measurement of intracellular ATP, and that this method may be considered superior to cultivable colony counts due to its speed and its ability to report the presence of viable but noncultivable organisms. When the detection of nonviable microbes is of interest, the ATP assay can be supplemented with DNA analysis.

NASA Discipline Environmental Health↗

Generation of a fluorescent short-lifetime oxygen nanosensor by coupling of an exciplex forming dye pair

Typical oxygen-sensitive dyes have lifetimes in the μs-ms regime for sensitive oxygen detection based on molecular quenching. Due to the long triplet-state lifetimes and poor quenching efficiency of these probes, it has been difficult to develop short lifetime probes. We have developed oxygen sensors using a short-lifetime dye (∼30–60 ns) that forms an anthracene-aniline exciplex, which is quenched by molecular oxygen through an excited-state charge transfer mechanism. To achieve measurements in aqueous systems, we have tethered the dyes together via a C3 alkyl linker to facilitate greater exciplex formation at low dye concentration (20 μg mL −1 ) and encapsulated the resulting compound into polymeric nanoparticles to form an aqueous-dispersible short-lifetime oxygen nanosensor. The sensors emit at 420 nm (unfolded dye) and 500 nm (exciplex), and the ratiometric Stern-Volmer Constant is 1.52 ± 0.02 L mol −1 , showing good sensitivity from 0 % to 40 % dissolved oxygen without the tradeoff of a long lifetime needed for direct molecular quenching. In this paper, we characterize this sensor for both lifetime-based measurements using time-correlated single-photon counting and ratiometric intensity-based measurements using the unfolded dye emission as an internal reference peak.

Biological and medical sciences↗

Strong lensing of high-energy neutrinos

Here, we consider the effects of strong gravitational lensing by galaxy-scale deflectors on the observations of high-energy ( E $\gg$ GeV ) neutrinos (HENs). For HENs at cosmological distances, the optical depth for multiple imaging is ~10 –3 , implying that while we do not expect any multiply imaged HENs with present samples, next-generation experiments should be able to detect the first such event. We then present the distribution of expected time delays to aid in the identification of such events, in combination with directional and energy information. In order to assist in the evaluation of HEN production mechanisms, we illustrate how lensing affects the observed number counts for a variety of intrinsic luminosity functions of the source population. Finally, we see that the lensing effects on the cosmic neutrino background flux calculation would be negligible by taking kiloparsec-scale jets as an example.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗