Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SPECTRAL ENERGY DISTRIBUTIONS AND AGE ESTIMATES OF 104 M31 GLOBULAR CLUSTERS

We present photometry of 104 M31 globular clusters (GCs) and GC candidates in 15 intermediate-band filters of the Beijing-Arizona-Taiwan-Connecticut photometric system. The GCs and GC candidates were selected from the Revised Bologna Catalog (v.3.5). We obtain the cluster ages by comparing the photometric data with up-to-date theoretical synthesis models. The photometric data used are Galaxy Evolution Explorer far- and near-ultraviolet and Two Micron All Sky Survey near-infrared JHK {sub s} magnitudes, combined with optical photometry. The ages of our sample clusters cover a large range, although most clusters are younger than 10 Gyr. Combined with the ages obtained in our series of previous papers focusing on the M31 GC system, we present the full M31 GC age distribution. The M31 GC system contains populations of young and intermediate-age GCs, as well as the 'usual' complement of well-known old GCs, i.e., GCs of similar age as the majority of the Galactic GCs. In addition, young GCs (and GC candidates) are distributed nearly uniformly in radial distance from the center of M31, while most old GCs (and GC candidates) are more strongly concentrated.

79 ASTRONOMY AND ASTROPHYSICS↗

Deterministically estimated fission source distributions for Monte Carlo k-eigenvalue problems

The standard Monte Carlo (MC) k-eigenvalue algorithm involves iteratively converging the fission source distribution using a series of potentially time-consuming inactive cycles before quantities of interest can be tallied. One strategy for reducing the computational time requirements of these inactive cycles is the Sourcerer method, in which a deterministic eigenvalue calculation is performed to obtain an improved initial guess for the fission source distribution. This method has been implemented in the Exnihilo software suite within SCALE using the SPNSPN or SNSN solvers in Denovo and the Shift MC code. The efficacy of this method is assessed with different Denovo solution parameters for a series of typical k-eigenvalue problems including small criticality benchmarks, full-core reactors, and a fuel cask. Here it is found that, in most cases, when a large number of histories per cycle are required to obtain a detailed flux distribution, the Sourcerer method can be used to reduce the computational time requirements of the inactive cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian analysis for estimating statistical parameter distributions of elasto-viscoplastic material models

High temperature design methods rely on constitutive models for inelastic deformation and failure typically calibrated against the mean of experimental data without considering the associated scatter. Variability may arise from the experimental data acquisition process, from heat-to-heat material property variations, or both and need to be accurately captured to predict parameter bounds leading to efficient component design. Applying the Bayesian Markov Chain Monte Carlo (MCMC) method to produce statistical models capturing the underlying uncertainty in the experimental data is an area of ongoing research interest. This work varies aspects of the Bayesian MCMC method and explores their effect on the posterior parameter distributions for a uniaxial elasto-viscoplastic damage model using synthetically generated reference data. From our analysis with the uniaxial inelastic model we determine that an informed prior distribution including different types of test conditions results in more accurate posterior parameter distributions. The parameter posterior distributions, however, do not improve when increasing the number of similar experimental data. Additionally, changing the amount of scatter in the data affects the quality of the posterior distributions, especially for the less sensitive model parameters. Moreover, we perform a sensitivity study of the model parameters against the likelihood function prior to the Bayesian analysis. The results of the sensitivity analysis help to determine the reliability of the posterior distributions and reduce the dimensionality of the problem by fixing the insensitive parameters. The comprehensive study described in this work demonstrates how to efficiently apply the Bayesian MCMC methodology to capture parameter uncertainties in high temperature inelastic material models. Quantifying these uncertainties in inelastic models will improve high temperature engineering design practices and lead to safer, more effective component designs.

42 ENGINEERING↗

Estimating the joint distribution of rate parameters across multiple reactions in the absence of experimental data

Here, a procedure for determining the joint uncertainty of Arrhenius parameters across multiple combustion reactions of interest is demonstrated. This approach is capable of constructing the joint distribution of the Arrhenius parameters arising from the uncertain measurements performed in specific target experiments without having direct access to the underlying experimental data. The method involves constructing an ensemble of hypothetical data sets with summary statistics consistent with the available information reported by the experimentalists, followed by a fitting procedure that learns the structure of the joint parameter density across reactions using this consistent hypothetical data as evidence. The procedure is formalized in a Bayesian statistical framework, employing maximum-entropy and approximate Bayesian computation methods and utilizing efficient Markov chain Monte Carlo techniques to explore data and parameter spaces in a nested algorithm. We demonstrate the application of the method in the context of experiments designed to measure the rates of selected chain reactions in the H 2 -O 2 system and highlight the utility of this approach for revealing the critical correlations between the parameters within a single reaction and across reactions, as well as for maximizing consistency when utilizing rate parameter information in predictive combustion modeling of systems of interest.

97 MATHEMATICS AND COMPUTING↗

Neutron Production and Fast Deuteron Characteristics at the Plasma Focus Discharge

This paper summarized the results of interferometry, X-ray and neutron diagnostics performed at the plasma focus facility filled with deuterium. The fusion processes are produced mainly in the dense and hot spherical structure of 2 cm diameter 5-8 cm in front of the anode. The electron temperature of this structure is about 750 eV and the density 5x10{sup 24}-5x10{sup 25}. The neutron energy distribution was calculated using time of flight analysis and showed the dominant direction of the fast deuteron velocity downstream. The deuteron energy distribution was estimated supposing isotropy distribution of the sum of opposite orientation. The total number of fast deuterons in the energy range of 10-400 keV is about 10{sup 18} with total energy of 20 kJ. Plasma in the spherical structure is heated dominantly with ion-ion Coulomb collisions of fast deuterons in the energy range below 10 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of proton distribution by means of three-dimensional reconstruction of prompt gamma rays

In proton therapy, the dose distribution of proton beams in the human body needs to be measured accurately. The distribution of prompt gamma rays emitted from patients during irradiation is strongly associated with the dose distribution of the proton beam. The (three-dimensional) 3D distribution of the prompt gamma rays detected by a single photon emission computed tomography was simulated using a Monte Carlo method. The 3D distribution of the prompt gamma rays was well matched with the dose distribution of the proton beam and was superior to the (two-dimensional) distribution of the prompt gamma rays detected using a conventional gamma camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-314: Estimation of Dose Distributions with Different Types of Breast Implants in Various Radiation Treatment Techniques for Breast Cancer

Purpose: This study investigates the effects of different kinds and designs of commercialized breast implants on the dose distributions in breast cancer radiotherapy under a variety of conditions. Methods: The dose for the clinical conventional tangential irradiation, Intensity Modulated Radiation Therapy (IMRT), volumetric modulated arc therapy (VMAT) breast plans was measured using radiochromic films and stimulated luminescence dosimeter (OSLD). The radiochromic film was used as an integrating dosimeter, while the OSLDs were used for real-time dosimetry to isolate the contribution of dose from individual segment. The films were placed at various slices in the Rando phantom and between the body and breast surface OSLDs were used to measure skin dose at 18 positions spaced on the two (right/left) breast. The implant breast was placed on the left side and the phantom breast was remained on the right side. Each treatment technique was performed on different size of the breasts and different shape of the breast implant. The PTV dose was prescribed 50.4 Gy and V47.88≥95%. Results: In different shapes of the breast implant, because of the shadow formed extensive around the breast implant, dose variation was relatively higher that of prescribed dose. As the PTV was delineated on the whole breast, maximum 5% dose error and average 3% difference was observed averagely. VMAT techniques largely decrease the contiguous hot spot in the skin by an average of 25% compared with IMRT. The both IMRT and VMAT techniques resulted in lower doses to normal critical structures than tangential plans for nearly all dose analyzation. Conclusion: Compared to the other technique, IMRT reduced radiation dose exposure to normal tissues and maintained reasonable target homogeneity and for the same target coverage, VMAT can reduce the skin dose in all the regions of the body.

60 APPLIED LIFE SCIENCES↗

Estimate of the Distribution of Solids Within Mixed Hanford Double-Shell Tank AZ-101: Implications for AY-102

This paper describes the current level of understanding of the suspension of solids in Hanford double-shell waste tanks while being mixed with the baseline configuration of two 300-horsepower mixer pumps. A mixer pump test conducted in Tank AZ-101 during fiscal year 2000 provided the basis for this understanding. Information gaps must be filled to demonstrate the capability of the baseline feed delivery system to effectively mix, sample, and deliver double-shell tank waste to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗