Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integrating Variable Renewable Energy Into the Grid: Key Issues

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. The variability of solar and wind compared to traditional sources, coupled with growing demand for electricity, requires changes to power system planning and operations to meet these targets. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE), primarily wind and solar, to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE while maintaining or increasing system stability and reliability. To inform decarbonization strategies, policymakers, regulators, and system operators consider a variety of costs and opportunities associated with VRE integration, which can be organized into five topics: New renewable energy generation and transmission; Power system reliability; Transmission and distribution coordination; Cross-sectoral decarbonization opportunities; Energy equity and justice.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Constellation: The autonomous control and data acquisition system for dynamic experimental setups

The operation of instruments and detectors in laboratory or beamline environments presents a complex challenge, requiring stable operation of multiple concurrent devices, often controlled by separate hardware and software solutions. These environments frequently undergo modifications, such as the inclusion of different auxiliary devices depending on the experiment or facility, adding further complexity. The successful management of such dynamic configurations demands a flexible and robust system capable of controlling data acquisition, monitoring experimental setups, enabling seamless reconfiguration, and integrating new devices with limited effort. This paper presents Constellation, a flexible and network-distributed control and data acquisition software framework tailored to laboratory and beamline environments, that addresses the limitations of existing solutions. The framework is designed with a focus on extensibility, providing a streamlined interface for instrument integration. It supports efficient system setup via network discovery mechanisms, promotes stability through autonomous operational features, and provides comprehensive documentation and supporting tools for operators and application developers such as controllers and logging interfaces. At the core of the architectural design is the autonomy of the individual components, called satellites, which can make independent decisions about their operation and communicate these decisions to other components. This paper introduces the design principles and framework architecture of Constellation, presents the available graphical user interfaces, shares insights from initial successful deployments, and provides an outlook on future developments and applications.

Autonomy↗

Integrated Systems-to-Atoms (S2A) Framework for Designing Resilient and Efficient Hydrogen Infrastructure Solutions

The success of a future clean hydrogen infrastructure will depend on technology performance, operating conditions, and system configuration, which will be integrated to meet specific end-use requirements. We introduce a Systems-to-Atoms framework to cosimulate material, device, and system design for clean hydrogen storage and transport. Here we present a demonstration scenario in which hydrogen is distributed using a liquid organic hydrogen carrier to 700 bar refueling stations. Cross-scale analysis on hydrogen release at the refueling station reveals that while a high reaction pressure (up to 100 bar) may not enhance the catalyst performance, it can lead to system-level cost savings (up to 5% of total refueling station cost) due to savings in downstream gas compression. Further, a typically low-performing dehydrogenation catalyst material (e.g., copper) may be preferred over a high-performing catalyst (e.g., palladium) at different operating conditions when considering overall system affordability and supply chain resilience.

08 HYDROGEN↗

Architecture and performance of Perlmutter's 35 PB ClusterStor E1000 all-flash file system

NERSC's newest system, Perlmutter, features a 35 PB all-flash Lustre file system built on HPE Cray ClusterStor E1000. Here, we present its architecture, early performance figures, and performance considerations unique to this architecture. We demonstrate the performance of E1000 OSSes through low-level Lustre tests that achieve over 90% of the theoretical bandwidth of the SSDs at the OST and LNet levels. We also show end-to-end performance for both traditional dimensions of I/O performance (peak bulk-synchronous bandwidth) and nonoptimal workloads endemic to production computing (small, incoherent I/Os at random offsets) and compare them to NERSC's previous system, Cori, to illustrate that Perlmutter achieves the performance of a burst buffer and the resilience of a scratch file system. Finally, we discuss performance considerations unique to all-flash Lustre and present ways in which users and HPC facilities can adjust their I/O patterns and operations to make optimal use of such architectures.

97 MATHEMATICS AND COMPUTING↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Temperature Gas-Cooled Pebble-Bed Reactors Running In And Transient Modeling Capabilities Demonstration

This study presents a comprehensive benchmarking and verification effort of several thermal-hydraulic and multiphysics capabilities for high-temperature gas-cooled reactor (HTGR) applications. The first part of this effort focuses on the running-in verification of Griffin's multiphysics capabilities, specifically for simulating the evolution of Pebble Bed reactor cores from startup to equilibrium. In the absence of validation data, code-to-code comparisons are conducted with Kugelpy, showing good agreement for key quantities like maximum power density and fresh core k-eigenvalue predictions. However, discrepancies in equilibrium core predictions suggest potential issues with cross sections, underscoring the need for further refinement and evaluation. The HTTF system analysis code benchmark involves RELAP5-3D, SAM, and GAMMA+ to assess their predictive capabilities for HTTF behavior under both normal operation and pressurized conduction cooldown (PCC) transient conditions. While there is good agreement in predicting major parameters such as coolant temperature, solid temperature, and flow distribution, discrepancies in transient behavior highlight differences in modeling approaches, nodalizations, and heat transfer models. The HTTF lower plenum CFD benchmark employs nekRS to simulate flow mixing phenomena, successfully capturing relevant flow physics and demonstrating mesh independence in complex geometries. Preliminary results suggest a relatively uniform temperature field but significant unsteadiness in the flow, requiring time-averaging analyses. The GPBR200 system analysis code benchmark uses SAM's core channel and porous media models, incorporating an RCCS loop for decay heat removal. During steady-state and transient conditions, including protected de-pressurized and pressurized loss of forced cooling (DLOFC and PLOFC), both models show good agreement in predicting temperature profiles and key parameters. Notably, while the core channel model underpredicts convective heat transfer effects, both models maintain temperatures well below the TRISO fuel safety limit. These benchmarking efforts collectively enhance the predictive capabilities of the tools used in HTGR design and safety analysis, guiding developments to improve their accuracy and applicability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rational design of heterogeneous single-site catalysts via surface organometallic chemistry

Single-site heterogeneous catalysts offer an attractive route to unite the molecular precision of homogeneous catalysis with the durability and practical advantages of solids. Surface organometallic chemistry (SOMC) provides a particularly powerful strategy for this purpose by grafting molecular precursors onto tailored surfaces and converting support functionalities into ligand environments for isolated metal centers. As a result, SOMC brings the language and logic of coordination chemistry to heterogeneous catalysis, where the support becomes an integral part of the active site coordination sphere. This Review surveys recent progress in the rational design of SOMC-derived single-site catalysts, with emphasis on synthetic routes, post synthetic transformations, and the deliberate tuning of catalytic behavior through metal-support interactions. Discussions are made on how support identity, hydroxyl topology, acidity, and redox activity shape the geometry, electronic structure, and oxidation state of supported metal sites, as well as how these factors determine activity, selectivity, and stability. We also examine a central limitation of these systems: despite their molecularly informed design, supported single sites often exist as structurally distributed ensembles rather than uniform species, particularly on amorphous supports. This site heterogeneity, along with catalyst dynamics under operating conditions, remains a major barrier to definitive structure-activity relationships. Therefore, emerging approaches that combine advanced characterization, first-principles modeling, ensemble kinetics, and machine learning to resolve active-site structure and guide catalyst development are highlighted. Together, these advances position SOMC as a versatile coordination chemistry framework for the predictive design of heterogeneous catalysts with well-defined molecularly tailored active sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generative AI for Grid Operations [Slides]

In the last few years, the development and use of generative artificial intelligence (AI) and large-language models (LLMs) have changed the landscape of how AI and machine learning (ML) are being used in power systems. LLMs are built on foundational models based on large data sets that can be trained to provide information rapidly and through simple natural language prompts. Generative AI can then perform human-like tasks using ML models to identify and mimic pattens in the data sets. This presentation explores how generative AI can enhance grid operations by improving forecasts, enabling rapid contingency analyses, and offering real-time operational suggestions. By providing grid operators with valuable insights, generative AI will empower them to manage power systems more effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SynthEsizing Novel H2 Sensors for Operational Resilience in Pipeline Infrastructure (SENSOR) (CRADA Final Report)

Hydrogen (H₂) is gaining attention as a versatile energy carrier with potential applications across industrial processes, power generation, and transportation. However, its practical deployment, particularly in large-scale distribution systems, faces significant infrastructure challenges. Transporting hydrogen through dedicated pipelines or blending it into existing natural gas networks can lead to serious issues, such as leakage due to the small size of hydrogen molecules and material degradation in pipelines through embrittlement. These technical risks raise safety concerns and could limit the integration of hydrogen into current energy infrastructures. Additionally, using hydrogen-enriched gas mixtures in combustion systems like turbines and engines introduces new performance and compatibility challenges that must be resolved before widespread use becomes feasible.

08 HYDROGEN↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗

Heterogeneous Multi-Domain Dataset Synthesis to Facilitate Privacy and Risk Assessments in Smart City IoT

The emergence of the Smart Cities paradigm and the rapid expansion and integration of Internet of Things (IoT) technologies within this context have created unprecedented opportunities for high-resolution behavioral analytics, urban optimization, and context-aware services. However, this same proliferation intensifies privacy risks, particularly those arising from cross-modal data linkage across heterogeneous sensing platforms. To address these challenges, this paper introduces a comprehensive, statistically grounded framework for generating synthetic, multimodal IoT datasets tailored to Smart City research. The framework produces behaviorally plausible synthetic data suitable for preliminary privacy risk assessment and as a benchmark for future re-identification studies, as well as for evaluating algorithms in mobility modeling, urban informatics, and privacy-enhancing technologies. As part of our approach, we formalize probabilistic methods for synthesizing three heterogeneous and operationally relevant data streams—cellular mobility traces, payment terminal transaction logs, and Smart Retail nutrition records—capturing the behaviors of a large number of synthetically generated urban residents over a 12-week period. The framework integrates spatially explicit merchant selection using K-Dimensional (KD)-tree nearest-neighbor algorithms, temporally correlated anchor-based mobility simulation reflective of daily urban rhythms, and dietary-constraint filtering to preserve ecological validity in consumption patterns. In total, the system generates approximately 116 million mobility pings, 5.4 million transactions, and 1.9 million itemized purchases, yielding a reproducible benchmark for evaluating multimodal analytics, privacy-preserving computation, and secure IoT data-sharing protocols. To show the validity of this dataset, the underlying distributions of these residents were successfully validated against reported distributions in published research. We present preliminary uniqueness and cross-modal linkage indicators; comprehensive re-identification benchmarking against specific attack algorithms is planned as future work. This framework can be easily adapted to various scenarios of interest in Smart Cities and other IoT applications. By aligning methodological rigor with the operational needs of Smart City ecosystems, this work fills critical gaps in synthetic data generation for privacy-sensitive domains, including intelligent transportation systems, urban health informatics, and next-generation digital commerce infrastructures.

IoT↗

A State-Space Model for Stability Boundary Analysis of Grid-Following Voltage Source Converters Considering Grid Conditions

With the growing significance of renewable energy resources and energy storage systems, the number of grid-connected inverters has been rising at an increasingly rapid pace. Generally, these inverters are directly integrated with the distribution network by synchronizing with the grid voltage at the point of common coupling. However, the low grid strength and varying R/X ratios, as the common characteristics of most distribution networks or weak grids, can lead to dynamic interactions that comprise stability and limit the power transfer capacity of grid-connected inverters. To ensure stable operation of the inverters, researchers must determine the stability boundary, described as the maximum power transfer capacity of grid-connected inverters under the premise of maintaining system small-signal stability. For this purpose, we propose to formulate a state-space model of the system in the synchronously rotating dq-frame of reference and perform eigenvalue analysis to determine the stability boundary. With a detailed model of the control structure and parameters of the grid-connected inverters, the stability boundary is identified as a surface with respect to different grid strengths and R/X ratios. Case study results of proposed eigenvalue analysis are compared with those of admittance model-based stability analysis as well as time-domain simulation using a switching model in Matlab/Simulink, validating the effectiveness and accuracy of the proposed eigenvalue analysis for stability boundary identification.

grid-connected inverters↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

Machine Learning for Scalable and Optimal Load Shedding Under Power System Contingency

Prompt and effective corrective actions in response to unexpected contingencies are crucial for improving power system resilience and preventing cascading blackouts. The optimal load shedding (OLS) accounting for network limits has the potential to address the diverse system-wide impacts of contingency scenarios as compared to traditional local schemes. However, due to the fast cascading propagation of initial contingencies, real-time OLS solutions are challenging to attain in large systems with high computation and communication needs. In this paper, we propose a decentralized design that leverages offline training of a neural network (NN) model for individual load centers to autonomously construct the OLS solutions from locally available measurements. Our learning-for-OLS approach can greatly reduce the computation and communication needs during online emergency responses, thus preventing the cascading propagation of contingencies for enhanced power grid resilience. Numerical studies on both the IEEE 118-bus system and a synthetic Texas 2000-bus system have demonstrated the efficiency and effectiveness of our scalable OLS learning design for timely power system emergency operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. The cryogenic plant is composed of two nitrogen precooled Tevatron satellite refrigerators, two Mycom 2016C compressors, a cryogenic distribution system, a Frick purifier compressor, two charcoal bed adsorber purifiers, and a liquid ring vacuum pump with a roots booster. The SRF cavities are immersed in a 2.0 K liquid helium bath, shielded with a 5 K gaseous helium shield and a liquid nitrogen cooled thermal shield. Since 2019, this R&D accelerator complex has gone through four science runs with an average duration of 12 months. Operational experience for each run, availability metrics, performance data and common outages are presented in this paper.

Wallace, Timothy [Fermilab] (ORCID:000900051589302↗