Search NASA⌕ Search

SEARCH · Search NASA

Results for “district energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Metagenomes and metagenome-assembled genomes from a nutrient removal plant at Los Angeles County Sanitation Districts (LACSD) that transitioned from high to low dissolved oxygen

Operating biological nutrient removal (BNR) wastewater treatment plants with low dissolved oxygen (DO) conditions can reduce energy costs. We report on five metagenomes and 492 metagenome-assembled genomes (MAGs) obtained from samples collected at the Pomona water reclamation plant before and after a DO reduction from 3.5 to 0.7 mg/L.

dissolved oxygen↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University: Preprint

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ("CUBO") was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

EGS Reservoir Modeling for Developing Geothermal District Heating at Cornell University

Cornell University is pursuing development of an enhanced geothermal system (EGS) for providing heating to its main campus in Upstate New York. A ~10,000 ft (~3 km) deep vertical observation well ('CUBO') was drilled in 2022 to characterize the subsurface using wellbore logging, borehole imaging, fluid sampling, mini-frac tests, coring and drill cutting analysis. Down-hole temperatures measured at 3 km depth are about 80 degrees C, sufficiently high for direct-use heating. The well drilled through generally low porosity and low permeability Paleozoic sedimentary formations and into metamorphic basement rock, encountered at about 9,400 ft depth. Leveraging subsurface data obtained through CUBO, we investigated technical feasibility and design requirements of a doublet well system with horizontal laterals connected to a fracture network created through hydraulic fracturing. The EGS reservoir is sized to provide a nominal heat output in the range 5 to 10 MWth of continuous heating over a 15 year-lifetime with limited thermal drawdown. We applied the Gringarten Multiple parallel fracture model, the Cornell Discrete Fracture Simulator FOXFEM and the commercial simulator ResFrac to estimate required heat transfer area and design a potential hydraulic stimulation treatment. Reservoir simulations indicate that, depending on fluid flow rate and injection temperature, 2 to 3 km2 of effective fracture heat transfer area is required to supply the target heat output of 5 to 10 MWth over 15 years.

district heating↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IrrigationViz: A Geospatial Visualization Application to Facilitate Irrigation Modernization

Irrigation water delivery infrastructure, such as canals and pipelines, are essential to agriculture in the Western U.S., yet many of these systems are reaching the end of their useful lives. Reinvestment can achieve a wide variety of benefits, from water conservation to energy savings or renewable energy generation. Modernization requires significant planning, design, and implementation funding which can be a challenge for many irrigation districts. Here, this paper introduces IrrigationViz, a web-based mapping application designed to help irrigation districts visualize and generate high-level cost and benefit estimates for infrastructure modernization projects. These estimates can help water managers identify projects that benefit from additional engineering resources and ultimately obtain funding. IrrigationViz includes map interactions, graphs, and visualization components to facilitate planning and communication to stakeholders and funders. IrrigationViz combines user-provided information about a water-delivery system with public datasets and basic engineering formulas to generate estimates of the benefits of reinvestment. Estimates include the amount of water seepage in earthen canals, potential hydropower generation associated with replacing a canal with a pressurized pipe, and pipe size recommendations. We found that hydropower generation estimates compared favorably with real world projects, but seepage loss estimates showed high variability relative to on-the-ground measurements

99 - GENERAL AND MISCELLANEOUS↗

Specification Guidance for School Lighting Systems [Slides]

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. LED lighting is a common lighting technology being specified today and many options are available for replacement or integration with existing fluorescent lighting systems. This document intends to help school districts retrofit or replace existing lighting systems in order to improve the classroom and school environment and reduce energy consumption and associated carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GHG Emissions Inventory Report for LvivTeploEnergo (LTE)

PNNL prepared the greenhouse gas (GHG) emissions inventory for LTE to help gain international funding for modernization requirements necessary to decarbonize LTE’s DH network. The inventory itself provides a comprehensive account of total greenhouse gas emissions from (a) LTE’s transportation (commuting and product transport), (b) purchased electricity (for water heating, heat production, and other uses), and (c) heat production for the DH network. The greenhouse gases analyzed in the inventory are Carbon Dioxide (CO 2 ), Carbon Monoxide (CO), and Nitrogen Oxide (NO x ). All data gathered for the inventory came directly from previous years of LTE data, with total emissions of each activity calculated by using emission factors from several internationally reputable sources (e.g., United National Framework Convention on Climate Change (UNFCCC), the ECLIPSE v6 dataset from the International Institute for Applied Systems Analysis (IIASA), the European Modeling and Evaluation Programme (EMEP), and the World Resources Institute (WRI)). This report further explains the methodology and justification for which scopes of emissions were included in the GHG emissions inventory spreadsheet and a description of references from which the emission factors were taken.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applying Particle Swarm Optimization and Extended Kalman Filtering to Model Kaplan Generation Dynamics for Hydropower Systems

Variable renewable generation is increasing the need for hydropower plants to provide fast and flexible grid support, which places new demands on plant-level dynamic models used for monitoring, control, and operational decision-making. This need is especially important for hydroelectric systems, where turbine and generator dynamics are strongly coupled, nonlinear, and time-varying, making accurate real-time representation difficult. To address this problem, this paper develops a digital twin (DT) framework for a synchronous generator–Kaplan turbine system using an explicit separation of slow turbine dynamics and fast generator dynamics. The turbine subsystem is represented by a six-coefficient model, whose parameters are identified offline using particle swarm optimization, while the generator subsystem is updated online through an extended Kalman filter for real-time state and parameter estimation. These models are integrated within a closed-loop simulation that includes a proportional–integral–derivative–double-derivative governor and excitation system, allowing the DT to track plant behavior under realistic operating conditions. Unlike prior studies that treat turbine and generator modeling separately or rely mainly on simulated inputs, the proposed framework is validated using real operational data from a hydropower plant. Results show that the DT reproduces terminal voltage, active power, and reactive power with a normalized root mean square error of approximately 5%. This hybrid offline–online formulation constitutes the main contribution of the work, providing an adaptive and practically deployable DT for hydropower systems with direct relevance to control improvement, performance monitoring, and grid-support applications under high renewable penetration.

13 HYDRO ENERGY↗

Geothermal Heat Pump Case Study: Berkeley County School District

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Berkeley County School District and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

15 GEOTHERMAL ENERGY↗

Thermal Reservoir Networks for Modularly Expandable Thermal Microgrids

The Department of Defense (DoD) faces the substantial challenge of cost-effectively retrofitting one to two installations per month, each comprising approximately 1,000 buildings, to improve resilience, reduce energy consumption, and enhance energy supply security. Achieving these objectives requires optimal system selection and effective risk mitigation during system integration. To address this need, we introduce Platform-Based Design (PBD), a structured, hierarchical methodology adapted from other industrial sectors to the domain of energy system retrofits. We demonstrate the effectiveness of PBD through a techno-economic feasibility study comparing geothermal-coupled thermal energy networks (TENs) with conventional energy systems for heating, cooling, and powering 17 buildings at Joint Base Andrews (JBA) in Maryland. Our analysis illustrates that the PBD approach enables rigorous, data-driven, sequential decision making, resulting in a family of Pareto-optimal systems, among which the TEN emerged as the most promising solution. The selected TEN design integrates geothermal borefields, heat recovery heat pumps, photovoltaic (PV) arrays, and battery storage. Compared to the baseline system – gas heating combined with air-source chillers – the proposed TEN reduces annual imported energy by 74% and peak electricity demand by 45%, achieves a levelized cost of energy of $\$0.210$/kWh, and substantially enhances resilience. Life-cycle costs increase by approximately 6%, and initial investment costs are about 2.5 times higher than the baseline. However, if central plant infrastructure, district loops, and utility-scale PV and battery systems are privately funded and operated, the initial investment would fall below the baseline system cost. Critical to achieving these significant performance improvements were detailed nonlinear dynamic simulations coupling geothermal heat transfer, energy system operation, and realistic feedback control logic. These simulations identified essential design modifications and control strategy refinements that substantially reduced energy use, peak demand, and compressor shortcycling, thereby improving durability and reliability—issues that would have been significantly more expensive to resolve during operation. Additionally, the verification step highlighted sensitivities to key design parameters that could reduce initial investment by approximately $\$2$ million and reduce annual life-cycle costs more than $\$300,000$. We recommend adopting the PBD methodology for future feasibility studies and TEN pilot projects to gain valuable operational experience. Furthermore, we recommend that DoD invest in transferring and scaling the PBD methodology to other installations. This entails developing standardized computational frameworks and component libraries as well as training industry in conducting PBD. Such investments would enable rapid, robust, reliable, and cost-effective retrofits, supporting DoD’s ambitious energy system modernization goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Resilience Options for the Koolauloa Community Resilience Hub – Energy Technology Innovation Partnership Project, Cohort 2: Summary of Findings and Assessment

Hui o Hau‘ula (HoH) is a community organization dedicated to the well-being of the population of the Ko‘olauloa district on the Hawaiian island of Oahu. In response to growing concerns about challenges related to extreme weather events or natural disasters, HoH formulated the concept of the Ko‘olauloa Community Resilience Hub, or KCRH. The KCRH facility would serve as a focal point for the community during normal conditions, while also providing essential services and acting as a safe space during emergencies, natural or man-made. The concept of the KCRH was initially developed in partnership with the Hawaii Natural Energy Institute, +Lab Architects, and the City and County of Honolulu. In the fall of 2023, the U.S. Department of Energy, under the Energy Technology Innovation Partnership Project Program (ETIPP), provided support to the KCRH project, in the form of technical assistance (TA) to be provided by its National Laboratory complex. In this case, the core TA was provided by Sandia National Laboratories, and it was directed to providing options for designing an energy system based at the KCRH that could support critical loads in the event of a 30- day grid outage. The National Renewable Energy Laboratory (NREL) provided communications and logistics support in the project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photographic Mitigation Documentation Related to the Engine Assembly and Disassembly Facility, Area 25, Nevada National Security Site, Nye County, Nevada

This letter report provides documentation in partial fulfillment of the mitigation of adverse effects to the Engine Maintenance Assembly and Disassembly (E-MAD) facility, a major component of the Nuclear Rocket Development Station (NRDS) Historic District located in Area 25 of the Nevada National Security Site (NNSS). Construction of the E-MAD facility began in 1962 for the purpose of disassembling and maintaining nuclear-powered rocket engines. Once the building was complete in 1967, the E-MAD facility remained in continuous operation until the nuclear rocket program was terminated in 1973. The mothballed facility was repurposed in 1977 for spent nuclear fuel handling and packaging activities. By the mid-1980s, all activities at the E-MAD facility had ceased (Reno et al. 2019). This submission is intended to comply with Stipulation III.D.1 of the Memorandum of Agreement DE-GM58-20NA25534 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Corrective Action Activities and Demolition of the Engine Maintenance Assembly and Disassembly Facility and the Test Cell C Historic District, Major Components of the Nuclear Rocket Development Station Historic District Located in Area 25 at the Nevada National Security Site Nye County (hereafter referred to as the MOA). Stipulation III.D.1 states the U.S. Department of Energy (DOE) will submit the existing supplementary collection of the large-format, black-and-white photographic prints taken during the 1996 Historic American Engineering Record (HAER) documentation of the E-MAD facility to the Nuclear Testing Archive (NTA), located on the second floor of the Rogers Building at Desert Research Institute (DRI) in Las Vegas, Nevada.

54 ENVIRONMENTAL SCIENCES↗

Submission of Mitigation Documentation Related to the Demolition of Building 12-7, Area 12 Camp, Nevada National Security Site, Nye County, Nevada

The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 12-7 (Nevada State Historic Preservation Office [SHPO] Resource No. B18287) in the Area 12 Camp Historic District (SHPO Resource No. D372) on the Nevada National Security Site (NNSS). Building 12-7 is a contributing element to the historic district. This submission is intended to comply with the stipulations in the Memorandum of Agreement DE-GM58-22NA25555 between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding the Removal of Buildings 12-7 and 12-30 in the Area 12 Camp of the Nevada National Security Site, Nye County, Nevada, hereafter referred to as the MOA.

54 ENVIRONMENTAL SCIENCES↗