Search NASA⌕ Search

SEARCH · Search NASA

Results for “drying procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Waste Management System overview for future spacecraft.

Waste Management Systems (WMS) for post Apollo spacecraft will be significantly more sophisticated and earthlike in user procedures. Some of the features of the advanced WMS will be accommodation of both males and females, automatic operation, either tissue wipe or anal wash, measurement and sampling of urine, feces and vomitus for medical analysis, water recovery, and solids disposal. This paper presents an overview of the major problems of and approaches to waste management for future spacecraft. Some of the processes discussed are liquid/gas separation, the Dry-John, the Hydro-John, automated sampling, vapor compression distillation, vacuum distillation-catalytic oxidation, incineration, and the integration of the above into complete systems.

Ingelfinger, A. L.↗

Oxidizer Testing on Alternative Absorbents for Los Alamos National Laboratory - 18656

In the summer of 2016, during glovebox operations in TA-55, cheesecloth, a cellulosic material, was used to clean up a small spill of 9.8 molar nitric acid (oxidizer). Because cellulosic materials and oxidizers are incompatible, this prompted a chemical compatibility evaluation of the waste in TA-55 to determine if this waste was Resource Conservation and Recovery Act (RCRA) ignitable waste (D001) or RCRA reactive waste (D003). After testing and consulting with the Carlsbad Field Office in Carlsbad (CBFO), Los Alamos National Laboratory (LANL) NPI-7 decided to look for alternative absorbents to use in the gloveboxes that would not create an incompatibility issue with an oxidizer. While small spills are infrequent, they do happen and LANL wanted to be proactive and search for a material that would be compatible with an oxidizer. In December 2016, LANL NPI-7 requested LANL-Carlsbad's (LANL-CO) Difficult Waste Team to perform compatibility testing on potential alternative wipes for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose for testing was to meet the Operational Experience Level 3 (OE-3) requirements that states 'any proposed use of organic absorbents or engineered absorbents in combination with potentially oxidizing TRU waste, wet or dry, should be evaluated and approved by the National TRU Program, Carlsbad Field Office' [1]. LANL NPI-7 requested LANL-CO to perform these tests because they were the group that performed all of the oxidizer testing for CBFO for the Basis of Knowledge (BoK) [2]. LANL NPI-7 chose nine fabrics and KMI Zeolite to be tested. The testing in Carlsbad took approximately 2 months to prepare the procedures, test plans and for the procurement of items. The burn rate testing was done in accordance with the requirements discussed in the BoK and approved by the LANL-CO Difficult Waste Team. Each absorbent was tested for 1) capacity limiting tests, 2) verifying the non-oxidizer threshold concentration of the oxidizer and 3) establishing the non-oxidizer concentration based on the experimental results. The effect of rinsing cheesecloth samples that have absorbed an oxidizer was also tested [3]. The burn rate testing provided three potential alternative absorbents (Spilfyter Hazmat Sorbent SM Pads Premium, Kimtech Pure W4 Wipers and Polybenzimidazole (PBI) Staple fiber) that produced a non-oxidizer result as defined by the BoK. Two wipes Spilfyter Hazmat Sorbent SM Pads Premium and Kimtech Pure W4 Wipers were able to absorb the highest concentration of potassium nitrite and still produce a non-oxidizer. TA-55 has used Spilfyter Hazmat Sorbent SM Pads Premium for a number of years in several of the processes and has ordered Kimtech Pure W4 Wipers for use in the facility. PBI fabric passed at 25 wt. % solution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A rapid thioacidolysis method for biomass lignin composition and tricin analysis

Abstract Background Biomass composition varies from plant to plant and greatly affects biomass utilization. Lignin is a heterogeneous phenolic polymer derived mainly from p -coumaryl, coniferyl, and sinapyl alcohols and makes up to 10–25% of lignocellulosic biomass. Recently, tricin, an O -methylated flavone, was identified as a lignin monomer in many grass species. Tricin may function as a nucleation site for lignification and is advocated as a novel target for lignin engineering to reduce lignin content and improve biomass digestibility in grasses. Thioacidolysis is an analytical method that can be adapted to analyze both lignin monomeric composition and tricin content in the lignin polymer. However, the original thioacidolysis procedure is complex, laborious, and time consuming, making it difficult to be adopted for large-scale screening in biomass research. In this study, a modified, rapid higher throughput thioacidolysis method was developed. Results In combination with gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–mass spectrometry (LC–MS), the modified thioacidolysis method can be used to simultaneously characterize the lignin composition and tricin content using 2–5 mg of dry samples. The modified method eliminates the solvent extraction and drastically improves the throughput; 80 samples can be processed in one day per person. Our results indicate that there is no significant difference in the determination of lignin S/G ratio and tricin content between the original and modified methods. Conclusions A modified thioacidolysis protocol was established. The results demonstrate that the modified method can be used for rapid, high-throughput, and reliable lignin composition and tricin content analyses for screening transgenic plants for cell wall modifications or in large-scale genome-wide association studies (GWAS).

09 BIOMASS FUELS↗

Chromium electrodes for REDOX cells

An improved electrode having a gold coating for use in the anode compartment of a REDOX cell is described. The anode fluid utilizes a chromic/chromous couple. A carbon felt is soaked in methanol, rinsed in water, dried and then heated in KOH after which it is again washed in deionized water and dried. The felt is then moistened with a methanol water solution containing chloroauric acid and is stored in a dark place while still in contact with the gold-containing solution. After all the gold-containing solution is absorbed in the felt, the latter is dried by heat and then heat treated at a substantially greater temperature. The felt is then suitable for use as an electrode and is wetted with water or up to two molar HCl prior to installation in a REDOX cell. The novelty of the invention lies in the use of KOH for cleaning the felt and the use of alcohol as a carrier for the gold together with the heat treating procedure.

Jalan, V.↗

Microscopic evaluation of a polyimide (PMR-15)-graphite composite

An effort to evaluate the high temperature performance of a polyimide (PMR-15)-graphite composite which consists of several plies of woven strands of carbon fibers was undertaken. The longterm effect of high temperature on the dry material was studied by exposing polished test specimens of 473 F in a oven for nearly 400 hours. Periodically the specimens were removed and observed microscopically. Gradually surface cracks began to appear and the number of cracks increased over time. At the conclusion of the exposure the specimens were graudually ground down and observed in order to determine the depth of the cracks into the interior of the material. This procedure was repeated at an exposure temperature of 550 F.

Fedderly, J. J.↗

Challenges to Cabin Humidity Removal Presented by Intermittent Condensing Conditions

On-orbit temperature and humidity control (THC) is more easily accomplished when the THC hardware is either consistently dry (i.e., no humidity control is occurring), or consistently wet. The system is especially challenged when intermittent wet/dry conditions occur. The first six years of on-orbit ISS operations have revealed specific concerns within the THC system, specifically in the condensing heat exchanger and the downstream air/water separator. Failed or degraded hardware has been returned to ground and investigated. This paper presents the investigation findings, and the recommended hardware and procedural revisions to prevent and recover from the effects of intermittent condensing conditions.

vonJouanne, Roger G.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Prospects for commercial production of diatoms

In this paper, a simple procedure that portends the open-pond growth of commercially viable diatoms is discussed. We examined a number of topics relevant to the production and harvesting of diatoms as well as topics concerning the production of bioproducts from diatoms. Among the former topics, we show that it is currently possible to continuously grow diatoms and control the presence of invasive species without chemical toxins at an average annual yield of 132 MT dry diatoms ha -1 over a period of almost 5 years, while maintaining the dominancy of the optimal diatom species on a seasonal basis. The dominant species varies during the year. The production of microalgae is essentially agriculture, but without the ability to control invasive species in the absence of herbicides and insecticides, pollution and production costs would be prohibitive. Among the latter topics are the discussions of whether it is better to produce lipids and then convert them to biofuels or maximize the production of diatom biomass and then convert it to biocrude products using, for example, hydrothermal processes. It is becoming increasingly evident that without massive public support, the commercial production of microalgal biofuels alone will remain elusive. While economically competitive production of biofuels from diatoms will be difficult, when priority is given to multiple high-value products, including wastewater treatment, and when biofuels are considered co-products in a systems approach to commercial production of diatoms, an economically competitive process will become more likely.

09 BIOMASS FUELS↗

Perspectives on the relationship between materials chemistry and roll-to-roll electrode manufacturing for high-energy lithium-ion batteries

As lithium-ion battery (LIB) active material and cell manufacturing costs continue to drop with wider adoption of electric vehicles, electrode and cell processing costs remain too high in terms of reaching the ultimate U.S. Department of Energy (DOE) cell cost target of $80/kWh. This paper primarily covers major materials chemistry advancements made over the last 10 years at Oak Ridge National Laboratory (ORNL) in the space of advanced manufacturing science for LIBs with the aim of simultaneously meeting the ultimate cost target, 500 Wh/kg gravimetric energy density, 10-15-min fast charge times, and 1000 deep discharge cycles. Aqeous electrode processing with a variety of active anode and cathode materials is now a standard procedure at the DOE Battery Manufacturing R&D Facility at ORNL (BMF), including the latest processes developed for Ni-rich cathodes. New results on cobalt-free LiNi 0.8 Fe 0.1 Al 0.1 O 2 (NFA 811) are also included and discussed in an electrode processing advantage context. In addition, colloidal processing advancements have been made for Si/C composite anodes for achieving >600 mA h/g capacities. Optimization of electrode coating parameters and drying protocols have been completed, which has elucidated how key processing variables need to be changed when parameters such as slurry solids loading, solvent type, and wet electrode thickness are changed. ORNL has also increased the line speeds at which thick cathodes can be processed using ultra-fast electron beam (EB) curing and substantially decreased formation cycling times to <1 day. Finally, key details of these advancements are discussed in the context of materials chemistry and process-property-performance relationships.

25 ENERGY STORAGE↗

XPS analysis of molecular contamination and sp 2 amorphous carbon on oxidized (100) diamond

The efficacy of oxygen (O) surface terminations on diamond is an important factor for the performance and stability for diamond-based quantum sensors and electronics. Given the wide breadth of O-termination techniques, it can be difficult to discern which method would yield the highest and most consistent O coverage. Furthermore, the interpretation of surface characterization techniques is complicated by surface morphology and purity, which if not accounted for will yield inconsistent determination of the oxygen coverage. We present a comprehensive approach to consistently prepare and analyze oxygen termination of surfaces on (100) single-crystalline diamond. We report on x-ray photoelectron spectroscopy (XPS) characterization of diamond surfaces treated with six oxidation methods that include various wet chemical oxidation techniques, photochemical oxidation with UV illumination, and steam oxidation using atomic layer deposition (ALD). Our analysis entails a rigorous XPS peak-fitting procedure for measuring the functionalization of O-terminated diamond. The findings herein have provided molecular-level insights on oxidized surfaces in (100) diamond, including the demonstration of clear correlation between the measured oxygen atomic percentage and the presence of molecular contaminants containing nitrogen, silicon, and sulfur. We also provide a comparison of the sp 2 carbon content with the O1s atomic percentage and discern a correlation with the diamond samples treated with dry oxidation which eventually tapers off at a max O1s atomic percentage value of 7.09 ± 0.40%. Given these results, we conclude that the dry oxidation methods yield some of the highest oxygen amounts, with the ALD water vapor technique proving to be the cleanest technique out of all the oxidation methods explored in this work.

XPS↗

Steady-state wear and friction in boundary lubrication studies

A friction and wear study was made at 20 C to obtain improved reproducibility and reliability in boundary lubrication testing. Ester-base and C-ether-base fluids were used to lubricate a pure iron rider in sliding contact with a rotating M-50 steel disk in a friction and wear apparatus. Conditions included loads of 1/2 and 1 kg and sliding velocities of 3.6 to 18.2 m/min in a dry air atmosphere and stepwise time intervals from 1 to 250 min for wear measurements. The wear rate results were compared with those from previous studies where a single 25 min test period was used. Satisfactory test conditions for studying friction and wear in boundary lubrication for this apparatus were found to be 1 kg load; sliding velocities of 7.1 to 9.1 m/min (50 rpm disk speed); and use of a time stepwise test procedure. Highly reproducible steady-state wear rates and steady-state friction coefficients were determined under boundary conditions. Wear rates and coefficients of friction were constant following initially high values during run-in periods.

Loomis, W. R.↗

Treatment of Radioactive Sludge From Waste Water Treatment for Weight and Volume Reduction with FreezeTec-Technique - 17010

At the Studsvik site in Sweden, Studsvik Nuclear AB operates a water treatment facility that treat all the waste water from the nuclear facilities at the site. The facility contains several pools for waste water treatment. The standard procedure for treating the water consist of adding FeCl{sub 3} to precipitate any particulates. Historically this waste has been mixed with concrete and grouted into barrels which will increase the volume needed for disposal in final repository. The sludge that is generated from the water treatment facility has been subject to treatment with the Freeze-Tec method where the sludge is freeze dewatered and after thawing generating a solid phase with high dry substance and a clear water phase. The radioactive particles/nuclides tend to stay in the solid phase while the water phase has very low concentration of radioactive particles. 99.9% of the Co-60 and Cs-137 activity end up in the solids and a dry solid with smaller volume and weight is obtained after treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The pressure and deformation profile between two colliding lubricated cylinders

The pressure and deformation profiles between two colliding lubricated cylinders are obtained by solving the coupled, time-dependent elastohydrodynamic equations with an iterative procedure. The analysis includes effects which were not considered in a previous solution, namely, the effect of the lubricant compressibility and the effect of a lubricant with composite pressure-viscosity coefficients. It is found that the local approach velocity plays an important role during final stages of normal approach. It causes the lubricant to be entrapped within the contact region; neither the pressure nor the deformation profile converges to the Hertzian profile for a dry contact. The use of a smaller pressure-viscosity coefficient at high pressures reduces the sharp pressure gradient at the center of the contact and produces a much milder variation of load with respect to the film thickness. The effect of compressibility of the lubricant is found to be relatively small.

Lee, K.↗

The Use of Liquid Isopropyl Alcohol and Hydrogen Peroxide Gas Plasma to Biologically Decontaminate Spacecraft Electronics

Legitimate concern exists regarding sending spacecraft and their associated hardware to solar system bodies where they could possibly contaminate the body's surface with terrestrial microorganisms. The NASA approved guidelines for sterilization as set forth in NPG 8020.12C, which is consistent with the biological contamination control objectives of the Committee on Space Research (COSPAR), recommends subjecting the spacecraft and its associated hardware to dry heat-a dry heat regimen that could potentially employ a temperature of 110(deg)C for up to 200 hours. Such a temperature exposure could prove detrimental to the spacecraft electronics. The stimulated growth of intermetallic compounds (IMCs) in metallic interconnects and/or thermal degradation of organic materials composing much of the hardware could take place over a prolonged temperature regimen. Such detrimental phenomena would almost certainly compromise the integrity and reliability of the electronics. Investigation of sterilization procedures in the medical field suggests that hydrogen peroxide (H202) gas plasma (HPGP) technology can effectively function as an alternative to heat sterilization, especially for heat-sensitive items. Treatment with isopropyl alcohol (IPA) in liquid form prior to exposure of the hardware to HPGP should also prove beneficial. Although IPA is not a sterilant, it is frequently used as a disinfectant because of its bactericidal properties. The use of IPA in electronics cleaning is widely recognized and has been utilized for many years with no adverse affects reported. In addition, IPA is the principal ingredient of the test fluid used in ionic contamination testers to assess the amount of ionic contamination found on the surfaces of printed wiring assemblies. This paper will set forth experimental data confirming the feasibility of the IPA/H202 approach to reach acceptable microbial reduction (MR) levels of spacecraft electronic hardware. In addition, a proposed process flow in which both IPA liquid and HPGP are utilized will be presented in Section 7.0.

microbial reduction↗

Using Holey Graphene for Improved Interfacial Contact in Solid Electrolyte Ionic Conductivity Measurements

Solid-state batteries (SSBs) are poised to become the batteries of the future with advantages such as higher energy density, lighter weight, versatile geometry, and greater safety due to low flammability risk. An important parameter of the solid electrolyte (SE) used is its ionic conductivity. The ionic conductivity is generally calculated from the bulk resistance of a SE pellet, measured from the electrochemical impedance spectroscopy data. The SE pellet is typically prepared from the electrolyte powder by dry compression and is sandwiched between two blocking current collectors to obtain the impedance spectroscopy data. One of the challenges in conducting this measurement is poor interfacial contacts between the SE pellet and the current collector surfaces. Therefore, measurements reported in the literature may underestimate the true ionic conductivity of a given electrolyte. Holey graphene is a carbon nanomaterial with high electrical conductivity and unique dry compressibility, which is unusual for carbon materials but similar to many oxide and sulfide SEs. In this work, it is demonstrated that adding a thin layer of holey graphene between the electrolyte and the stainless steel current collectors significantly improves the interfacial contact. The ionic conductivity values obtained in the effort were sometimes several times higher than the data measured for SEs without the holey graphene layers. This work calls for more standardized measurement procedures to reduce the discrepancies in reported ionic conductivity values.

Solid state battery↗

Turbojet engine blade damping

The potentials of various sources of nonaerodynamic damping in engine blading are evaluated through a combination of advanced analysis and testing. The sources studied include material hysteresis, dry friction at shroud and root disk interfaces as well as at platform type external dampers. A limited seris of tests was conducted to evaluate damping capacities of composite materials (B/AL, B/AL/Ti) and thermal barrier coatings. Further, basic experiments were performed on titanium specimens to establish the characteristics of sliding friction and to determine material damping constants J and n. All the tests were conducted on single blades. Mathematical models were develthe several mechanisms of damping. Procedures to apply this data to predict damping levels in an assembly of blades are developed and discussed.

Srinivasan, A. V.↗

Quantitative analysis of wet-heat inactivation in bovine spongiform encephalopathy

Highlights: ► We quantitatively analyzed wet-heat inactivation of the BSE agent. ► Infectivity of the BSE macerate did not survive 155 °C wet-heat treatment. ► Once the sample was dehydrated, infectivity was observed even at 170 °C. ► A quantitative PMCA assay was used to evaluate the degree of BSE inactivation. - Abstract: The bovine spongiform encephalopathy (BSE) agent is resistant to conventional microbial inactivation procedures and thus threatens the safety of cattle products and by-products. To obtain information necessary to assess BSE inactivation, we performed quantitative analysis of wet-heat inactivation of infectivity in BSE-infected cattle spinal cords. Using a highly sensitive bioassay, we found that infectivity in BSE cattle macerates fell with increase in temperatures from 133 °C to 150 °C and was not detected in the samples subjected to temperatures above 155 °C. In dry cattle tissues, infectivity was detected even at 170 °C. Thus, BSE infectivity reduces with increase in wet-heat temperatures but is less affected when tissues are dehydrated prior to the wet-heat treatment. The results of the quantitative protein misfolding cyclic amplification assay also demonstrated that the level of the protease-resistant prion protein fell below the bioassay detection limit by wet-heat at 155 °C and higher and could help assess BSE inactivation. Our results show that BSE infectivity is strongly resistant to wet-heat inactivation and that it is necessary to pay attention to BSE decontamination in recycled cattle by-products.

60 APPLIED LIFE SCIENCES↗

Development of iron phosphate ceramic waste form to immobilize radioactive waste solution

The objective of this research was to develop an iron phosphate ceramic (IPC) waste form using converter slag obtained as a by-product of the steel industry as a source of iron instead of conventional iron oxide. Both synthetic off-gas scrubber solution containing technetium-99 (or Re as a surrogate) and LiCl-KCl eutectic salt, a final waste solution from pyrochemical processing of spent nuclear fuel, were used as radioactive waste streams. The IPC waste form was characterized for compressive strength, reduction capacity, chemical durability, and contaminant leachability. Compressive strengths of the IPC waste form prepared with different types of waste solutions were 16 MPa and 19 MPa for LiCl-KCl eutectic salt and the off-gas scrubber simulant, respectively, which meet the minimum compressive strength of 3.45 MPa (500 psi) for waste forms to be accepted into the radioactive waste repository. The reduction capacity of converter slag, a main dry ingredient used to prepare the IPC waste form, was 4,136 meq/kg by the Ce(IV) method, which is much higher than those of the conventional Fe oxides used for the IPC waste form and the blast furnace slag materials. Average leachability indexes of Tc, Li, and K for the IPC waste form were higher than 6.0, and the IPC waste form demonstrated stable durability even after 63-day leaching. In addition, the Toxicity Characteristic Leach Procedure measurements of converter slag and the IPC waste form with LiCl-KCl eutectic salt met the universal treatment standard of the leachability limit for metals regulated by the Resource Conservation and Recovery Act. This study confirms the possibility of development of the IPC waste form using converter slag, showing its immobilization capability for radionuclides in both LiCl-KCl eutectic salt and off-gas scrubber solutions with significant cost savings.

converter slag↗