Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamical process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Time-dependent oral absorption models

The plasma concentration-time profiles following oral administration of drugs are often irregular and cannot be interpreted easily with conventional models based on first- or zero-order absorption kinetics and lag time. Six new models were developed using a time-dependent absorption rate coefficient, ka(t), wherein the time dependency was varied to account for the dynamic processes such as changes in fluid absorption or secretion, in absorption surface area, and in motility with time, in the gastrointestinal tract. In the present study, the plasma concentration profiles of propranolol obtained in human subjects following oral dosing were analyzed using the newly derived models based on mass balance and compared with the conventional models. Nonlinear regression analysis indicated that the conventional compartment model including lag time (CLAG model) could not predict the rapid initial increase in plasma concentration after dosing and the predicted Cmax values were much lower than that observed. On the other hand, all models with the time-dependent absorption rate coefficient, ka(t), were superior to the CLAG model in predicting plasma concentration profiles. Based on Akaike's Information Criterion (AIC), the fluid absorption model without lag time (FA model) exhibited the best overall fit to the data. The two-phase model including lag time, TPLAG model was also found to be a good model judging from the values of sum of squares. This model also described the irregular profiles of plasma concentration with time and frequently predicted Cmax values satisfactorily. A comparison of the absorption rate profiles also suggested that the TPLAG model is better at prediction of irregular absorption kinetics than the FA model. In conclusion, the incorporation of a time-dependent absorption rate coefficient ka(t) allows the prediction of nonlinear absorption characteristics in a more reliable manner.

Non-NASA Center↗

A global empirical model of thermospheric composition based on OGO-6 mass spectrometer measurements

The analysis of composition measurements made with the neutral mass spectrometer aboard the OGO-6 satellite leads to the following conclusions. The measured atomic oxygen densities are generally in good agreement with those deduced from drag. The molecular nitrogen densities in the annual and semiannual variations depart significantly from those predicted by drag models and suggest similar departures for exospheric temperatures. The helium densities generally tend to vary in an inverse manner to the nitrogen densities. These composition changes are consistent with dynamical processes associated with the global circulation in the thermosphere.

Hedin, A. E.↗

Analysis of inner and outer zone: OGO-1 and OGO-2 electron spectrometer and ion chamber data

The dynamic processes governing the acceleration and loss of electrons in the radiation zones are investigated. The radial diffusion coefficient was determined for a McIlwain parameter between 1.6 and 2.2 for electrons having a first adiabatic invariant of 12 MeV/gauss. The coefficient is larger than earlier values and suggests that there exists a lower limit to the fluxes in the inner zone. The agreement between observed and calculated magnetic fields and particle fluxes is improved by using solar wind pressure as input to the magnetic field models. Changes in the plasma pressure can cause apparent local time asymmetries in particle flux. A comparison of the magnetic field models with observed location of the trapping boundary also indicates the need for including distributed currents within the magnetosphere. The high latitude trapping boundary is only weakly dependent on A sub p, and the trapping boundary data are improved by including in the models a stand-off distance which varies with the plasma pressure.

Pfitzer, K. A.↗

Neutral composition variation above 400 kilometers during a magnetic storm.

Examination of data from the neutral atmospheric composition experiment launched aboard Ogo 6, June 5, 1969, for the period from Sept. 27 through Oct. 3, 1969. Several magnetic storms occurred during this time, and the response of the neutral atmosphere to the energy deposition causing these storms was studied. The data indicate that the major portion of the energy is deposited at high latitudes, causing enhancements in N2 densities corresponding to Jacchia (1970) temperature increases on the order of 400 to 500 K. The time difference between atmospheric response and magnetic activity appears to be very short at high latitudes. The O/N2 ratio variations suggest dynamic processes that cause a circulation in the atmosphere that is upward at the pole with subsidence at the equator.

Taeusch, D. R.↗

Outer planets grand tours: Planetary radio astronomy team report

Requirements related to scientific observations of planetary radio emissions during outer planets grand tours are discussed. Observations at low frequencies where non-thermal cooperative plasma phenomena play a major role are considered for determining dynamical processes and magnetic fields near a planet. Magnetic field measurements by spacecraft magnetometers, and by radio receivers in their harmonic modes are proposed for interpretation of planetary radio emission.

Warwick, J. W.↗

Postflight simulation of parachute deployment dynamics of Viking qualification flight tests

Simulation calculations of the Viking qualification flight tests are conducted by use of analytical models of the parachute deployment dynamics process. Results from the study indicate that good simulations of event times and trajectory are obtained. If the full-scale parachute drag coefficient is used, a good simulation of first opening load is obtained and the overall nature of the load history is calculated. For longitudinal motions, the two-degree-of-freedom models give good agreement with a six-degree-of-freedom model. It is believed that the analytical models used are tools which will aid in the analysis of future flight systems.

Whitlock, C. H.↗

Development of propulsion for high atmospheric pressure or dense environments

The development of a propulsion system that employs a detonating propellant is described, and the need for such a system and its use in certain planetary atmospheres are demonstrated. A theoretical formulation of the relevant gas-dynamic processes was developed, and a related series of experimental tests were pursued.

Varsi, G.↗

S-band radio occultation measurements of the atmosphere and topography of Mars with Mariner 9: Extended mission coverage of polar and intermediate latitudes

Radio occultation measurements from Mariner 9 orbits around Mars show that the radius of Mars changes by only about 2 km from a latitude of 65 deg to the north pole, that the north polar area is about average in elevation, and that polar temperature profiles are indicative of the possibility that the remnant north polar cap may be at least partially composed of water ice. It is also found that Mars, in addition to being asymmetrical equatorially, is also significantly asymmetrical in the north and south direction with the Southern Hemisphere lying 3 to 4 km higher. Temperature gradients in the clear Martian atmosphere of only about one-half of the adiabatic gradients of 5 deg K/km suggest the importance of dynamical processes.

Kliore, A. J.↗

Miniature biotelemeter giving 10 channels of wideband biomedical data.

A miniature biotelemeter has been developed for sensing and transmitting multiple channels of wideband biomedical data over a radio link. Its small size and weight make it capable of being carried by free-moving laboratory animals as small as rats. Ten data channels each of 5-kHz data bandwidth are provided to permit monitoring of a wide variety of physiological signals. Multichannel telemetry of electroencephalograms, electrocardiograms, electromyograms, state functions, and dynamic processes such as blood flow and body chemistry are possible applications. Utilization of newly available monolithic chip components, low-power COS/MOS MSI digital logic, and state-of-the-art hybrid mounting techniques makes this novel device useful for both research and clinical bioinstrumentation.

Carraway, J.↗