Search NASA⌕ Search

SEARCH · Search NASA

Results for “effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An effective description of dark matter and dark energy in the mildly non-linear regime

In the next few years, we are going to probe the low-redshift universe with unprecedented accuracy. Among the various fruits that this will bear, it will greatly improve our knowledge of the dynamics of dark energy, though for this there is a strong theoretical preference for a cosmological constant. We assume that dark energy is described by the so-called Effective Field Theory of Dark Energy, which assumes that dark energy is the Goldstone boson of time translations. Such a formalism makes it easy to ensure that our signatures are consistent with well-established principles of physics. Since most of the information resides at high wavenumbers, it is important to be able to make predictions at the highest wavenumber that is possible. Furthermore, the Effective Field Theory of Large-Scale Structure (EFTofLSS) is a theoretical framework that has allowed us to make accurate predictions in the mildly non-linear regime. In this paper, we derive the non-linear equations that extend the EFTofLSS to include the effect of dark energy both on the matter fields and on the biased tracers. For the specific case of clustering quintessence, we then perturbatively solve to cubic order the resulting non-linear equations and construct the one-loop power spectrum of the total density contrast.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective anisotropy due to the surface of magnetic nanoparticles

Analytical solution has been discovered for the second-order effective anisotropy of magnetic nanoparticles of a cubic shape due to the surface anisotropy (SA) of the Néel type. Similarly to the spherical particles, for the simple cubic lattice the grand-diagonal directions (±1,±1,±1) are favored by the effective cubic anisotropy but the effect is twice as strong. Uniaxial core anisotropy and applied magnetic field cause screening of perturbations from the surface at the distance of the domain-wall width and reduce the effect of SA near the energy minima. Yet, screening disappears near the uniaxial energy barrier, and the uniform barrier state of larger particles may become unstable. For these effects the analytical solution is obtained as well, and the limits of the additive formula with the uniaxial and effective cubic anisotropies for the particle are established. Thermally-activated magnetization-switching rates have been computed by the pulse-noise technique for the stochastic Landau-Lifshitz equation for a system of spins.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Continuum and symmetry-conserving effects in drip-line nuclei using finite-range forces

We report the first calculations of nuclear properties near the drip lines using the spherical Hartree-Fock-Bogoliubov mean-field theory with a finite-range force supplemented by continuum and particle-number projection effects. Calculations were carried out in a basis made of the eigenstates of a Woods-Saxon potential computed in a box, thereby guaranteeing that continuum effects were properly taken into account. Projection of the self-consistent solutions on good particle number was carried out after variation, and an approximation of the variation after projection result was used. We give the position of the drip lines and examine neutron densities in neutron-rich nuclei. We discuss the sensitivity of nuclear observables upon continuum and particle-number restoration effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Form of the effective interaction in harmonic-oscillator-based effective theory

I explore the form of the effective interaction in harmonic-oscillator-based effective theory (HOBET) in leading order (LO) through next-to-next-to-next-to-leading order (N{sup 3}LO). Because the included space in a HOBET (as in the shell model) is defined by the oscillator energy, both long-distance (low-momentum) and short-distance (high-momentum) degrees of freedom reside in the high-energy excluded space. A HOBET effective interaction is developed in which a short-range contact-gradient expansion, free of operator mixing and corresponding to a systematic expansion in nodal quantum numbers, is combined with an exact summation of the relative kinetic energy. By this means the very strong coupling of the included (P) and excluded (Q) spaces by the kinetic energy is removed. One finds a simple and rather surprising result, that the interplay of QT and QV is governed by a single parameter {kappa}, the ratio of an observable, the binding energy |E|, to a parameter in the effective theory, the oscillator energy ({Dirac_h}/2{pi}){omega}. Once the functional dependence on {kappa} is identified, the remaining order-by-order subtraction of the short-range physics residing in Q becomes systematic and rapidly converging. Numerical calculations are used to demonstrate how well the resulting expansion reproduces the running of H{sup eff} from high scales to a typical shell-model scale of 8({Dirac_h}/2{pi}){omega}. At N{sup 3}LO various global properties of H{sup eff} are reproduced to a typical accuracy of 0.01%, or about 1 keV, at 8({Dirac_h}/2{pi}){omega}. Channel-by-channel variations in convergence rates are similar to those found in effective field theory approaches. The state dependence of the effective interaction has been a troubling problem in nuclear physics and is embodied in the energy dependence of H{sup eff}(|E|) in the Bloch-Horowitz formalism. It is shown that almost all of this state dependence is also extracted in the procedures followed here, isolated in the analytic dependence of H{sup eff} on {kappa}. Thus there exists a simple, Hermitian H{sup eff} that can be use in spectral calculations. The existence of a systematic operator expansion for H{sup eff}, depending on a series of short-range constants augmented by {kappa}, will be important to future efforts to determine the HOBET interaction directly from experiment, rather than from an underlying NN potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear transparency and effective kaon-nucleon cross section from the A(e,e{sup '}K{sup +}) reaction

We have determined the transparency of the nuclear medium to kaons from A(e,e{sup '}K{sup +}) measurements on {sup 12}C, {sup 63}Cu, and {sup 197}Au targets. The measurements were performed at the Jefferson Laboratory and span a range in four-momentum-transfer squared Q{sup 2}=1.1-3.0 GeV{sup 2}. The nuclear transparency was defined as the ratio of measured kaon electroproduction cross sections with respect to deuterium ({sigma}{sup A}/{sigma}{sup D}). We further extracted the atomic number (A) dependence of the transparency as parametrized by T=(A/2){sup {alpha}-1} and, within a simple model assumption, the in-medium effective kaon-nucleon cross sections. The effective cross sections extracted from the electroproduction data were found to be smaller than the free cross sections determined from kaon-nucleon scattering experiments, and the parameter {alpha} was found to be significantly larger than those obtained from kaon-nucleus scattering. We have included similar comparisons between pion- and proton-nucleon effective cross sections as determined from electron-scattering experiments and pion-nucleus and proton-nucleus scattering data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗

Equilibrium criterion and effective spin models for finite temperature gauge theories

Using the example of the SU(2) gauge theory in 3+1 dimensions we consider the construction of a 3-dimensional effective model in terms of Polyakov loops. We demonstrate the application of an equilibrium self-consistency condition to the systematic analysis of the contribution of various [global Z(2) symmetric] terms in the effective model action. We apply this analysis to the construction of a simple effective action with the minimum necessary number of operators. Such an action is shown to be capable of reproducing relevant observables, e.g. the Polyakov loop ensemble average, within the desired accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Indication on the Process Dependence of the Sivers Effect

We analyze the spin asymmetry for single inclusive jet production in proton-proton collisions collected by the AnDY experiment at the Relativistic Heavy Ion Collider and the Sivers asymmetry data from semi-inclusive deep inelastic scattering experiments. In particular, we consider the role color gauge invariance plays in determining the process dependence of the Sivers effect. We find that after carefully taking into account the initial-state and final-state interactions between the active parton and the remnant of the polarized hadron, the calculated jet spin asymmetry based on the Sivers functions extracted from HERMES and COMPASS experiments is consistent with the AnDY experimental data. This provides a first indication for the process dependence of the Sivers effect in these processes. Furthermore, we also make predictions for both direct photon and Drell-Yan spin asymmetry, to further test the process dependence of the Sivers effect in future experiments.

Gamberg, Leonard↗

Effects of impurities on membrane-protein crystallization in different systems

The effects of commonly encountered impurities on various membrane-protein crystallization regimes are investigated and it is found that the lipidic cubic phase crystallization methodology is the most robust, tolerating protein contamination levels of up to 50%, with little effect on crystal quality. If generally applicable, this tolerance may be exploited (i) in initial crystallization trials to determine the ‘crystallizability’ of a given membrane-protein and (ii) to subject partially pure membrane-protein samples to crystallization trials. When starting a protein-crystallization project, scientists are faced with several unknowns. Amongst them are these questions: (i) is the purity of the starting material sufficient? and (ii) which type of crystallization experiment is the most promising to conduct? The difficulty in purifying active membrane-protein samples for crystallization trials and the high costs associated with producing such samples require an extremely pragmatic approach. Additionally, practical guidelines are needed to increase the efficiency of membrane-protein crystallization. In order to address these conundrums, the effects of commonly encountered impurities on various membrane-protein crystallization regimes have been investigated and it was found that the lipidic cubic phase (LCP) based crystallization methodology is more robust than crystallization in detergent environments using vapor diffusion or microbatch approaches in its ability to tolerate contamination in the forms of protein, lipid or other general membrane components. LCP-based crystallizations produced crystals of the photosynthetic reaction center (RC) of Rhodobacter sphaeroides from samples with substantial levels of residual impurities. Crystals were obtained with protein contamination levels of up to 50% and the addition of lipid material and membrane fragments to pure samples of RC had little effect on the number or on the quality of crystals obtained in LCP-based crystallization screens. If generally applicable, this tolerance for impurities may avoid the need for samples of ultrahigh purity when undertaking initial crystallization screening trials to determine preliminary crystallization conditions that can be optimized for a given target protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation Metrics for Fixed Effects and Mixed-Effects Calibration

The modern scientific process often involves the development of a predictive computational model. To improve its accuracy, a computational model can be calibrated to a set of experimental data. A variety of validation metrics can be used to quantify this process. Some of these metrics have direct physical interpretations and a history of use, while others, especially those for probabilistic data, are more difficult to interpret. In this work, a variety of validation metrics are used to quantify the accuracy of different calibration methods. Frequentist and Bayesian perspectives are used with both fixed effects and mixed-effects statistical models. Through a quantitative comparison of the resulting distributions, the most accurate calibration method can be selected. Two examples are included which compare the results of various validation metrics for different calibration methods. It is quantitatively shown that, in the presence of significant laboratory biases, a fixed effects calibration is significantly less accurate than a mixed-effects calibration. This is because the mixed-effects statistical model better characterizes the underlying parameter distributions than the fixed effects model. The results suggest that validation metrics can be used to select the most accurate calibration model for a particular empirical model with corresponding experimental data.

97 MATHEMATICS AND COMPUTING↗

The Effects of Channel Supplies on Overall Film-Cooling Effectiveness

Abstract Cooling components in the hot section of a gas turbine are essential to component durability. Common methods of cooling include rib turbulators in internal passages and film cooling on external surfaces. The holes that produce the film cooling are fed from the internal channels often containing ribs. Consequently, there is an interdependence of internal heat transfer and external film cooling. The purpose of this study was to obtain a better understanding of the interaction of ribs and film cooling. To quantify the cooling performance, the surface temperatures were measured, from which overall effectiveness was calculated. For the experiments, additively manufactured test coupons were made of Inconel 718 to match engine Biot numbers. These test coupons had internal feed channels with and without ribs and had both cylindrical holes and meter-diffuser-shaped holes with 15 deg lateral expansion angles and a 1 deg forward expansion angle. A single rectangular channel was one type of feed channel. The other type of feed channel was individual circular channels, with each circular channel supplying an individual film-cooling hole. The experimental results showed that the circular individual channels have 80% higher baseline overall effectiveness than the single rectangular channels without any film cooling. Ribbed turbulators without film cooling also increased the overall effectiveness by 21% for single rectangular channels and by 29% for the circular individual channels compared to the respective non-ribbed channels. While the film cooling increased the overall effectiveness of all geometries, the single rectangular channels had increased overall effectiveness levels by up to twice that of the no film-cooling case. On average, the single rectangular channels had an 80% improvement from film cooling, whereas the individual channel feeds, on average, had only a 50% improvement, given their high baseline effectiveness levels.

Engineering↗

The Effect of Transient Fuel Staging on Self-Excited Instabilities in a Multi-Nozzle Model Gas Turbine Combustor

Combustion instability in gas turbines can be mitigated using active techniques or passive techniques, but passive techniques are almost exclusively used in industrial settings. While fuel staging, a common passive technique, is effective in reducing the amplitude of self-excited instabilities in gas turbine combustors at steady-state conditions, the effect of transients in fuel staging on self-excited instabilities is not well understood. This paper examines the effect of fuel staging transients on a laboratory-scale five-nozzle can combustor undergoing self-excited instabilities. The five nozzles are arranged in a four-around-one configuration and fuel staging is accomplished by increasing the center nozzle equivalence ratio. When the global equivalence ratio is φ = 0.70 and all nozzles are fueled equally, the combustor undergoes self-excited oscillations. These oscillations are suppressed when the center nozzle equivalence ratio is increased to φ = 0.80 or φ = 0.85. Two transient staging schedules are used, resulting in transitions from unstable to stable operation, and vice-versa. It is found that the characteristic instability decay times are dependent on the amount of fuel staging in the center nozzle. It is also found that the decay time constants differ from the growth time constants, indicating hysteresis in stability transition points. High speed CH* chemiluminescence images in combination with dynamic pressure measurements are used to determine the instantaneous phase difference between the heat release rate fluctuation and the combustor pressure fluctuation throughout the combustor. This analysis shows that the instability onset process is different from the instability decay process.

Culler, Wyatt↗

The effect of head size/shape, miscentering, and bowtie filter on peak patient tissue doses from modern brain perfusion 256-slice CT: How can we minimize the risk for deterministic effects?

Purpose: To determine patient-specific absorbed peak doses to skin, eye lens, brain parenchyma, and cranial red bone marrow (RBM) of adult individuals subjected to low-dose brain perfusion CT studies on a 256-slice CT scanner, and investigate the effect of patient head size/shape, head position during the examination and bowtie filter used on peak tissue doses. Methods: The peak doses to eye lens, skin, brain, and RBM were measured in 106 individual-specific adult head phantoms subjected to the standard low-dose brain perfusion CT on a 256-slice CT scanner using a novel Monte Carlo simulation software dedicated for patient CT dosimetry. Peak tissue doses were compared to corresponding thresholds for induction of cataract, erythema, cerebrovascular disease, and depression of hematopoiesis, respectively. The effects of patient head size/shape, head position during acquisition and bowtie filter used on resulting peak patient tissue doses were investigated. The effect of eye-lens position in the scanned head region was also investigated. The effect of miscentering and use of narrow bowtie filter on image quality was assessed. Results: The mean peak doses to eye lens, skin, brain, and RBM were found to be 124, 120, 95, and 163 mGy, respectively. The effect of patient head size and shape on peak tissue doses was found to be minimal since maximum differences were less than 7%. Patient head miscentering and bowtie filter selection were found to have a considerable effect on peak tissue doses. The peak eye-lens dose saving achieved by elevating head by 4 cm with respect to isocenter and using a narrow wedge filter was found to approach 50%. When the eye lies outside of the primarily irradiated head region, the dose to eye lens was found to drop to less than 20% of the corresponding dose measured when the eye lens was located in the middle of the x-ray beam. Positioning head phantom off-isocenter by 4 cm and employing a narrow wedge filter results in a moderate reduction of signal-to-noise ratio mainly to the peripheral region of the phantom. Conclusions: Despite typical peak doses to skin, eye lens, brain, and RBM from the standard low-dose brain perfusion 256-slice CT protocol are well below the corresponding thresholds for the induction of erythema, cataract, cerebrovascular disease, and depression of hematopoiesis, respectively, every effort should be made toward optimization of the procedure and minimization of dose received by these tissues. The current study provides evidence that the use of the narrower bowtie filter available may considerably reduce peak absorbed dose to all above radiosensitive tissues with minimal deterioration in image quality. Considerable reduction in peak eye-lens dose may also be achieved by positioning patient head center a few centimeters above isocenter during the exposure.

60 APPLIED LIFE SCIENCES↗

Effect of burst and recombination models for Monte Carlo transport of interacting carriers in a-Se x-ray detectors on Swank noise

Purpose: The authors describe the modification to a previously developed Monte Carlo model of semiconductor direct x-ray detector required for studying the effect of burst and recombination algorithms on detector performance. This work provides insight into the effect of different charge generation models for a-Se detectors on Swank noise and recombination fraction. Methods: The proposed burst and recombination models are implemented in the Monte Carlo simulation package, ARTEMIS, developed byFang et al. [“Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se,” Med. Phys. 39(1), 308–319 (2012)]. The burst model generates a cloud of electron-hole pairs based on electron velocity, energy deposition, and material parameters distributed within a spherical uniform volume (SUV) or on a spherical surface area (SSA). A simple first-hit (FH) and a more detailed but computationally expensive nearest-neighbor (NN) recombination algorithms are also described and compared. Results: Simulated recombination fractions for a single electron-hole pair show good agreement with Onsager model for a wide range of electric field, thermalization distance, and temperature. The recombination fraction and Swank noise exhibit a dependence on the burst model for generation of many electron-hole pairs from a single x ray. The Swank noise decreased for the SSA compared to the SUV model at 4 V/μm, while the recombination fraction decreased for SSA compared to the SUV model at 30 V/μm. The NN and FH recombination results were comparable. Conclusions: Results obtained with the ARTEMIS Monte Carlo transport model incorporating drift and diffusion are validated with the Onsager model for a single electron-hole pair as a function of electric field, thermalization distance, and temperature. For x-ray interactions, the authors demonstrate that the choice of burst model can affect the simulation results for the generation of many electron-hole pairs. The SSA model is more sensitive to the effect of electric field compared to the SUV model and that the NN and FH recombination algorithms did not significantly affect simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer

Purpose: The authors evaluated the effects of multileaf collimator (MLC) leaf width (2.5 vs. 5 mm) on dosimetric parameters and delivery efficiencies of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) for head and neck (H and N) cancers. Methods: The authors employed two types of mock phantoms: large-sized head and neck (LH and N) and small-sized C-shape (C-shape) phantoms. Step-and-shoot IMRT (S and S-IMRT) and VMAT treatment plans were designed with 2.5- and 5.0-mm MLC for both C-shape and LH and N phantoms. Their dosimetric characteristics were compared in terms of the conformity index (CI) and homogeneity index (HI) for the planning target volume (PTV), the dose to organs at risk (OARs), and the dose-spillage volume. To analyze the effects of the field and arc numbers, 9-field IMRT (9F-IMRT) and 13-field IMRT (13F-IMRT) plans were established for S and S-IMRT. For VMAT, single arc (VMAT{sub 1}) and double arc (VMAT{sub 2}) plans were established. For all plans, dosimetric verification was performed using the phantom to examine the relationship between dosimetric errors and the two leaf widths. Delivery efficiency of the two MLCs was compared in terms of beam delivery times, monitor units (MUs) per fraction, and the number of segments for each plan. Results: 2.5-mm MLC showed better dosimetric characteristics in S and S-IMRT and VMAT for C-shape, providing better CI for PTV and lower spinal cord dose and high and intermediate dose-spillage volume as compared with the 5-mm MLC (p < 0.05). However, no significant dosimetric benefits were provided by the 2.5-mm MLC for LH and N (p > 0.05). Further, beam delivery efficiency was not observed to be significantly associated with leaf width for either C-shape or LH and N. However, MUs per fraction were significantly reduced for the 2.5-mm MLC for the LH and N. In dosimetric error analysis, absolute dose evaluations had errors of less than 3%, while the Gamma passing rate was greater than 95% according to the 3%/3 mm criteria. There were no significant differences in dosimetric error between the 2.5- and 5-mm MLCs. Conclusions: As compared with MLC of 5-mm leaf widths, MLC with finer leaf width (2.5-mm) can provide better dosimetric outcomes in IMRT for C-shape. However, the MLC leaf width may only have minor effects on dosimetric characteristics in IMRT for LH and N. The results of the present study will serve as a useful assessment standard when assigning or introducing equipment for the treatment of H and N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the interplay effects with proton scanning beams in stage III lung cancer

Purpose: To assess the dosimetric impact of interplay between spot-scanning proton beam and respiratory motion in intensity-modulated proton therapy (IMPT) for stage III lung cancer. Methods: Eleven patients were sampled from 112 patients with stage III nonsmall cell lung cancer to well represent the distribution of 112 patients in terms of target size and motion. Clinical target volumes (CTVs) and planning target volumes (PTVs) were defined according to the authors' clinical protocol. Uniform and realistic breathing patterns were considered along with regular- and hypofractionation scenarios. The dose contributed by a spot was fully calculated on the computed tomography (CT) images corresponding to the respiratory phase that the spot is delivered, and then accumulated to the reference phase of the 4DCT to generate the dynamic dose that provides an estimation of what might be delivered under the influence of interplay effect. The dynamic dose distributions at different numbers of fractions were compared with the corresponding 4D composite dose which is the equally weighted average of the doses, respectively, computed on respiratory phases of a 4DCT image set. Results: Under regular fractionation, the average and maximum differences in CTV coverage between the 4D composite and dynamic doses after delivery of all 35 fractions were no more than 0.2% and 0.9%, respectively. The maximum differences between the two dose distributions for the maximum dose to the spinal cord, heart V40, esophagus V55, and lung V20 were 1.2 Gy, 0.1%, 0.8%, and 0.4%, respectively. Although relatively large differences in single fraction, correlated with small CTVs relative to motions, were observed, the authors' biological response calculations suggested that this interfractional dose variation may have limited biological impact. Assuming a hypofractionation scenario, the differences between the 4D composite and dynamic doses were well confined even for single fraction. Conclusions: Despite the presence of interplay effect, the delivered dose may be reliably estimated using the 4D composite dose. In general the interplay effect may not be a primary concern with IMPT for lung cancers for the authors' institution. The described interplay analysis tool may be used to provide additional confidence in treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrinsic quantized anomalous Hall effect in a moiré heterostructure

The quantum anomalous Hall (QAH) effect combines topology and magnetism to produce precisely quantized Hall resistance at zero magnetic field. We report the observation of a QAH effect in twisted bilayer graphene aligned to hexagonal boron nitride. The effect is driven by intrinsic strong interactions, which polarize the electrons into a single spin- and valley-resolved moiré miniband with Chern number C = 1. In contrast to magnetically doped systems, the measured transport energy gap is larger than the Curie temperature for magnetic ordering, and quantization to within 0.1% of the von Klitzing constant persists to temperatures of several kelvin at zero magnetic field. Electrical currents as small as 1 nanoampere controllably switch the magnetic order between states of opposite polarization, forming an electrically rewritable magnetic memory.

Science & Technology - Other Topics↗