Search NASA⌕ Search

SEARCH · Search NASA

Results for “electric propulsion modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Electric Medium- and Heavy-Duty Vehicle Charging Infrastructure Attributes and Development

Although more established for light-duty vehicles (LDVs), advancements in electric vehicle (EV) charging technology are being made in the medium- and heavy-duty (MD/HD) sector. Progress is also being made with the electrification of MD/HD vehicles, including transit buses, school buses, MD trucks, and HD trucks. The diverse set of operational requirements and duty cycles for each vocation, as well as the range in the size of fleets, present unique charging and infrastructure requirements. This report focuses on charging requirements for MD/HD vehicles and synergies with LDV infrastructure. This analysis leans toward the qualitative rather than quantitative because relevant model inputs are in development and will not be established for a few years, as EV deployments are more mature in the LDV sectors than MD/HD. The report begins with an overview of MD/HD vehicle classes and types of charging, including depot and residential charging, among others (Section 2). Section 3 analyzes the home bases (overnight dwell locations) of existing MD/HD vehicles, with an emphasis on depot and residential home bases, and discusses implications for charging infrastructure. Section 4 discusses the key characteristics for determining if, when, and where MD/HD vehicles can leverage LDV charging infrastructure rather than requiring dedicated chargers. These considerations include electricity demand, connectors, physical space requirements, payment considerations, and impacts on the grid. Section 5 summarizes shared characteristics for MD/HD vehicles that are appropriate for near-term electrification and includes a summary of the outlook of the electric MD/HD vehicle market. The conclusion (Section 6) summarizes the report's findings and outlines areas for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Charging needs for electric semi-trailer trucks

Battery-electric vehicles provide a pathway to decarbonize heavy-duty trucking, but the market for heavy-duty battery-electric semi-trailer trucks is nascent, and specific charging requirements remain uncertain. We leverage large-scale vehicle telematics data (>205 million miles of driving) to estimate the charging behaviors and infrastructure requirements for U.S. battery-electric semi-trailer trucks within three operating segments: local, regional, and long-haul. We model two types of charging - mid-shift (fast) and off-shift (slow) - and show that off-shift charging at speeds compatible with current light-duty charging infrastructure (i.e., =350 kW) can supply 35% to 77% of total energy demand for local and regional trucks with =300-mile range. Megawatt-level speeds are required for mid-shift charging, which make up 44% to 57% of energy demand for long-haul trucks with =500-mile range. However, demand shifts from mid-shift to off-shift charging as the range for battery-electric trucks increases and when off-shift charging is widely available. Finally, we observe geographic trends in charging demand, finding that local trucks have greater demand within urban areas, whereas long-haul trucks have more demand along rural interstate corridors. As the range for battery-electric trucks increases, we show that charging demand shifts from rural to urban locations due to observed vehicle dwell tendencies.

33 ADVANCED PROPULSION SYSTEMS↗

Controller Hardware-in-the-Loop Modeling and Operation of a High-Power DC Charging Hub

High-power charging (HPC) concept will be a critical enabler for the wide-scale adoption and integration of electric vehicles (EVs). HPC hubs will have a significant impact on achieving this goal, particularly when considering the charging requirements of next-generation medium and heavy-duty vehicles (MD/HD) used in various vocational scenarios. This emphasizes the significance of evaluating and confirming the technical planning and multi-level operation of HPC hubs through modeling, protocol implementation, and simulation before hardware demonstration. The focus of this study is to develop the architecture, modeling, communication, and real-time controller hardware-in-the-loop (C-HIL) simulation of HPC hubs using the DC distribution system approach. Specifically, this work demonstrates the practical implementation of a custom Smart Energy Management System (SEMS) for a real-time C-HIL HPC hub simulation using the Open Charge Point Protocol (OCPP) for communication. OCPP is implemented on the Node-Red framework and the custom controller is executed in Python. We developed a rule-based controller to demonstrate the proposed approach.

ADVANCED PROPULSION SYSTEMS↗

Evaluation of Aggregated EV Flexibility With TSO-DSO Coordination

Electric vehicles (EVs) are becoming a promising source of grid ancillary services due to the temporal and spatial charging flexibility, quick response and storage capability. Such advantages are increasing with government policy promotion and technology improvement. However, the exploration of EV flexibility requires the coordination of both transmission system operators (TSOs) and distribution system operators (DSOs), to ensure the safe and reliable operation of power network. In this paper, we propose a coordinated evaluation method that determines the optimal utilization of EV temporal flexibility without compromising EV owners’ usage. At the distribution level, DSOs first evaluate EV aggregators’ operational boundaries to exploit distribution level services. At the transmission level, TSOs then determine EV charging schedules and ancillary service capacity simultaneously, taking into account the requirement from DSOs. Here, we validate the model in a case study using the IEEE 123 node test feeder and EV charging sessions obtained from a transportation simulation tool that uses real-world data.

33 ADVANCED PROPULSION SYSTEMS↗

An experimentally validated electro-thermal EV battery pack model incorporating cycle-life aging and cell-to-cell variations

Lithium-ion batteries are used in a wide variety of applications. To meet the power and energy demands of these applications battery packs are composed of hundreds to thousands of cells. The electrical and thermal interactions between cells introduce additional complexity in the pack dynamics. To capture these effects, a battery pack model composed of 192 cells based on a first-generation (2012) Nissan Leaf battery pack is developed in MATLAB/Simulink/Simscape. Here, with this model, we simulate the electrical dynamics (using a first-order equivalent-circuit model), the thermal dynamics (using a first-order lumped-parameter thermal model), and the aging dynamics (using a semi-empirical severity factor-based model) of every cell in the pack and we also create a pack thermal model that explicitly captures the heat exchange between the modules, and the cells contained within, during operation. The models are calibrated and validated, both at the cell and pack level, with experimental data. Two different case studies of this pack model are investigated. In the first case study, an initial, normally-distributed, cell-to-cell capacity variation is introduced and its effect on the pack voltage and module temperatures is studied. In the second case study, we deliberately insert cells with lower than nominal capacity into the pack and we investigate how this type of initial cell-to-cell capacity variation affects the pack’s ability to deliver energy over time. Finally, we also study how parallel-connected cells can reduce the effects of cell-to-cell variations at the expense of increased aging of the pack overall.

25 ENERGY STORAGE↗

Estimating Fast Charging Infrastructure Requirements to Fully Electrify Ride-Hailing Fleets Across the United States

Ride-hailing electrification is made challenging by a variety of factors, including limited driver access to overnight charging and a nascent network of public direct-current fast charging (DCFC). This article projects the DCFC infrastructure needed to electrify ride-hailing across 384 cities in the United States. Research leveraging a novel infrastructure projection tool, Electric Vehicle Infrastructure Tool for On-Demand Mobility Services model (EVI-OnDemand), estimates that 25,400 DCFC ports capable of charging vehicles at a mean power of 150 kW are required to electrify 1.45 million ride-hailing vehicles in the baseline scenario. Results show that ride-hailing vehicles require 17.5 DCFC ports per 1000 vehicles, three times that of personal electric vehicles (EVs). Infrastructure demand is also shown to vary across cities; 63% more DCFC ports are needed to support 1000 battery EVs in Chicago versus Miami. The analysis also includes sensitivity studies that explore variation in charging demand across input assumptions, finding that charging power, vehicle class, overnight charging access rates, and port utilization influence the network size needed. Projections vary from 18,600 to 41,300 DCFC ports across sensitivity scenarios, indicating that ride-hailing electrification will require significant expansion of access to fast charging even in the most optimistic scenarios, and investments into supporting assets can reduce the scale of the public charging expansion needed.

33 ADVANCED PROPULSION SYSTEMS↗

Electricity demand in South Asia – data gaps and pathways for research and modeling

South Asia is one of the fastest growing regions - economically and energy-wise in the world. However, there are significant uncertainties in how the energy demand would grow given the rapidly rising incomes, urbanization, industrialization, access to energy, warming climate and technological change. The transition to clean energy in the region is a priority and is critical to limiting emissions in the region and increasing regional energy security. The power sector will play an important role in decarbonization of energy systems, lowering emissions in other sectors through electrification. However, as existing end uses are scaled up more and new end uses are electrified, the temporal and spatial patterns of electricity consumption could change. These changes have implications for the magnitude, shape, and timing of peak demand, which in turn affects the power sector’s investments and operations, and ability to provide reliable power. In this report, we outline key uncertainties in demand growth that South Asian countries would face in the near to medium term, along with summarizing insights from stakeholder consultations we held over the past 6 months.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EVI-Equity

EVI-Equity (Electric Vehicle Infrastructure for Equity) is a $200k project, started around in June of 2021, with a funding from the Vehicle Technologies Office (VTO). The motivation was to create a new analytical capability that can enable us to quantify and investigate equitable access to and distribution of existing and future deployment of PEVs and EVSEs in neighborhoods, cities, states, and the nation. EVI-Equity is a bottom-up equity-focused analysis model, built upon individual (synthetic) households, aggregated by census block groups. It consists of four core components - community engagement, environmental profiling, household expenditures, and network design. Although there are some commonalities, EVI-Equity is not a vehicle choice model, charging simulation model, or transportation demand model. EVI-Equity is rather a cross-cutting analysis tool, dedicated for evaluating equitable EV adoption and EVSE deployment, encompassing and bridging a wide variety of related tools, models, and frameworks. Some of the results indicate the importance of used vehicle market for low-income households. The presentation also highlights similarities and variations as to preferred public charging locations. For example, regardless of household income, retail spots are the most preferred location for public charging, followed by curbside/street. However, the results also imply that the importance of workplace charging may vary with income - the lower the income, the less important. Environmental profiling results, with an example of ground-level ozone in Atlanta area, show that the contrast between the haves and the have nots of plug-in electric vehicles depends on location. The assessment of household expenditures illustrates the economic impact of home charging access on an individual household level - the lower the income, the greater the impact is. Lastly, Denver metro area and the state of South Dakota are used to showcase the impact of different network design of charging infrastructure, as well as alternative (vs. baseline/existing) electric vehicle adoption pattern.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Modeling Future Demand for EV Charging Infrastructure [Slides]

U.S. climate goals for economy-wide net-zero greenhouse gas emissions by 2050 require rapid decarbonization of the light-duty vehicle fleet and plug-in electric vehicles (EVs) are poised to become the preferred technology for achieving this end. Considerable investments in public and private EV charging infrastructure will be needed to support widespread adoption, however, guidance is lacking on when, where, and what types of chargers will be needed. In this PLMA Load Management Dialogue session, researchers from the National Renewable Energy Laboratory (NREL) discuss findings from a recent quantitative assessment of the charging network requirements to support high penetrations of light-duty EVs by 2030. The study produced multiple detailed network growth trajectories at the national, state, and local levels that serve as a guidepost for future planning. In addition, an overview of NREL's publicly accessible EV infrastructure tools and data sets, designed to support planning and decision-making for EV infrastructure stakeholders, is provided.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.

33 ADVANCED PROPULSION SYSTEMS↗

Quantifying and modeling of stress-driven short-circuits in lithium-ion batteries in electrified vehicles

Despite the huge expansion of electric vehicle sales in the market, customers are discouraged by the possible catastrophic consequences brought by the safety issues of lithium-ion batteries, such as internal short circuits, especially in crash scenarios. Herein, we reveal the quantitative relationship between the deformations of the battery and the internal short circuit. By in situ and ex situ observations and post mortem characterization of the component materials, we quantify the stress-driven internal short circuit and failure behavior of the component material. With the aid of a validated numerical computational model as well as the in situ characterization of the global-field temperature, we successfully identify the minor and major short circuits of the cells upon various mechanical abusive loadings. Finally, we establish the internal short circuit criteria for typical formats of batteries. Furthermore, this discovery also provides a fundamental understanding of both internal and external stress-driven short circuits in a much broader context.

25 ENERGY STORAGE↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Developing rapid electrochemical relithiation protocols for scalable relithiation of lithium-ion battery cathode materials

The recent and ongoing boom in electric vehicle sales has caused the circularity of the supply chain for electric vehicle battery materials to come under a great deal of scrutiny. Innovative recycling processes, or direct recycling, that offer the possibility of reducing the cost of recycling are one possible solution to regaining resources from end-of-life (EoL) electric vehicle batteries. Electrochemically shuttling lithium back into the cathode, or electrochemical relithiation, is a possible technique for restoring lithium content to NMC materials (EoL) in a direct recycling process. This study provides essential understanding towards developing an electrochemical relithiation protocol that will restore lithium loss in intercalation cathode materials that reach EoL by loss of lithium inventory (LLI) as opposed to other degradation mechanisms like loss of active material (LAM), cation mixing or phase transition. Electrochemically aged NMC cathode materials have been prepared and characterized to establish the extent of EoL material structural degradation and lithium loss. A model-informed experimental process is used to identify the optimal electrochemical relithiation protocol to minimize the time taken to relithiate EoL materials and maximize the amount of lithium restored. Protocols were evaluated based on their ability to enable rapid lithium intercalation, maintain structural uniformity in the EoL material and fully restore lithium content. An optimal protocol was identified at elevated temperatures utilizing a novel scanning voltage step.

25 ENERGY STORAGE↗

Temperature Rise on Liner Surfaces of Fuel Cell Electric Vehicle Tanks during Fueling Process

Herein, the temperature of the inner tank walls, or plastic liners, of composite pressure tanks in fuel cell electric vehicles during fueling using three‐dimensional computational fluid dynamics (CFD) models is evaluated. The liner materials are limited to 85.0 °C to prevent thermal stress causing material failure that would result in a hydrogen leak. Therefore, the temperature of hydrogen gas must be limited to below 85.0 °C during the fueling process as dictated by the current fueling protocol. However, there are limited experimental or simulation data confirming that the temperature changes do not exceed the threshold. Herein, the liner temperatures with CFD tank models for two sizes of type IV tanks representative of the upper and lower system bounds that are close to the SAE J2601 fueling protocol (36.0 and 244.0 L) are evaluated. First, each model's reliability is validated with experimental data and then analyzed, and the data are used to evaluate the maximum hydrogen and liner temperatures under real‐world fueling conditions. The evaluation shows that the maximum liner surface temperature of each tank model is at least 7 °C lower than that of the hydrogen. Additionally, there is at least 12 °C difference found between the upper limit and actual liner temperatures.

33 ADVANCED PROPULSION SYSTEMS↗

Port of New York and New Jersey Drayage Electrification Analysis

The National Renewable Energy Laboratory (NREL) evaluated the potential for drayage electrification in the Port of New York and New Jersey (PoNYNJ), with a focus on operators: Harbor Freight Transport (HF), Safeway Trucking (SWT), and International Motor Freight Inc (IMF). This report summarizes the data collection and electrification evaluation of all three drayage operators, includes detailed operational data, and identifies the performance requirements for battery electric tractors (BETs) and corresponding infrastructure operated within the context of PoNYNJ drayage operation. This report also details a methodology to evaluate opportunities, strategies, and challenges associated with future expansions of BETs in meeting PANYNJ emissions goals. The Port Authority has established a goal of achieving Net Zero carbon emissions by 2050 across all facilities, including from tenant and stakeholder sources such as drayage trucks. NREL used real-world performance data collected on the three PoNYNJ drayage operations, along with modeling and analysis tools to compare BET to diesel trucks. From March to July 2021, NREL collected 1Hz vehicle and engine data from 46 drayage trucks at the three operators totaling nearly 121,000 miles of operation, providing enough information to assess vehicle operations for electrification potential. A Future Automotive Systems Technology Simulator (FASTSim) electric truck powertrain model was validated using PoNYNJ data and scenarios were run to evaluate drayage truck electrification requirements over the real-world cycles. The first scenario examined BET viability with minimal changes to existing operations. This assumes the trucks charge when stopped for two hours or longer, have a functional battery size of 375 kWh, and can charge at 270 kilowatts (kW) average which are the specification of the commercially available Freightliner eCascadia. The second scenario looked at what operational, charging infrastructure, and BET technology changes would be needed to fully electrify. Finally, detailed analysis was run on charging rate structure to understand operational costs to the fleets. The studied drayage trucks averaged 5.1 MPG, spent roughly 9% of their energy at idle, and drove an average of 140 miles per day with a maximum daily distance of 573 miles. The FASTSim model results indicate a comparable BET would use 417 kWh of energy per day on average accounting for cargo weight, which is close to the full usable capacity of the eCascadia currently available on the market. Based on the daily average operating data, partial fleet electrification is possible with current technology. However, some specific days of operation would require over 1,600 kWh of energy due to longer distances traveled by the trucks and more intense operation. Trucks used for long distance and intense operation cannot be readily electrified with current technology without operational changes. Full adoption of BETs could reduce CO 2 emissions from these fleets by roughly 75% today, eliminating 76 metric tons of CO 2 (MTCO 2 ) per vehicle each year, which equates to 24,100 MTCO 2 per year for all three operators. Commercially available direct current fast chargers (DCFC) have charge rates up to 350 kW. Based on the average daily modeled energy use for each operator, current industrial rate structures, and the assumption of 350 kW peak charging, full drayage electrification would increase electricity consumption. In addition, peak demand usage would increase with unmanaged charging along with cost of electricity having a direct impact on cost per mile for electric vehicles. The resulting cost per mile for BETs along with comparable cost per mile for conventional diesel trucks are also examined at $\$$4.00 per gallon of diesel. It will be important for PANYNJ and the drayage operators within the PoNYNJ to consider these load impacts to their existing electrical infrastructure and devise operational strategies that avoid coincident charging of vehicles to mitigate demand charges. Despite these electricity cost increases, savings from reductions in diesel consumption will help offset the costs of this increased electricity consumption. However, prices of both electricity and diesel are subject to change based on various factors meaning the realized savings will vary over time. This shows BETs could be cost-competitive on an energy cost per mile basis for all scenarios while diesel is above $\$$3.00/gal. Further, if diesel prices dropped to the 15-year low of $2.33/gal, it would still be cost competitive to operate the EVs with electricity costs of 16.3 ¢/kWh or less.

33 ADVANCED PROPULSION SYSTEMS↗

Component Modeling, Co-Optimization, and Trade-Space Evaluation (FY2021 Annual Progress Report)

This project is intended to support the development of new traction drive systems that meet the targets of 100 kW/L for power electronics and 50 kW/L for electric machines with reliable operation to 300,000 miles. To meet these goals, new designs must be identified that make use of state-of-the-art and next-generation electronic materials and design methods. Designs must exploit synergies between components, for example converters designed for high-frequency switching using wide band gap devices and ceramic capacitors. This project includes: (1) a survey of available technologies; (2) the development of design tools that consider the converter volume and performance; (3) exercising the design software to evaluate performance gaps and predict the impact of certain technologies and design approaches, i.e. GaN semiconductors, ceramic capacitors, and select topologies; and (4) building and testing hardware prototypes to validate models and concepts. Early instantiations of the design tools enable co-optimization of the power module and passive elements and provide some design guidance; later instantiations will enable the co-optimization of inverter and machine. Prototype testing begins with evaluation of simpler conversion topologies (i.e. the half-bridge boost converter) and progresses with fabrication of prototype inverter drives.

33 ADVANCED PROPULSION SYSTEMS↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Assessment and Coordination of EVSE Cybersecurity Standards

Cybersecurity certification programs for Electric Vehicle Supply Equipment (EVSE) are fragmented due to no single certification covering all aspects of the device and additionally the existence of multiple programs and under different levels of regulation. These devices are also confronted by the intricate assembly of product software, firmware, and hardware. Devices contain both logical and physical interfaces. These multifaceted devices have vulnerabilities at many levels and interconnect with other potentially vulnerable systems including the electric vehicle, the cloud where data and payment information are stored, and the electric grid and electric grid equipment including utilities. Of the EVSE certification programs that are found, none are directly for the cybersecurity of EVSE. Many standards are for safety, specifically battery safety, some are cybersecurity standards for other types of equipment and can be modeled for EVSE. In specific, ISA/IEC 62443 is found to be significantly in line with EVSE security needs and will be used in future testing to certify EVSE and help guide the project to demonstrate where gaps exist, where strengths lie in the standard and how this can be used to lead the certification efforts in harmonizing EVSE cybersecurity standards. In addition, there are multiple efforts that are currently seeking to build EVSE standards or revise existing standards to address gaps. This effort is seeking to establish a cybersecurity program for EVSE that will inform customers and help increase the level of security across products and state EVSE procurements to achieve consistency across different jurisdictions.

33 ADVANCED PROPULSION SYSTEMS↗