Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrochemical sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Bridging Additive Manufacturing and Electronics Printing in the Age of AI

Printing techniques have been instrumental in developing flexible and stretchable electronics, including organic light-emitting diode displays, organic thin film transistor arrays, electronic skins, organic electrochemical transistors for biosensors and neuromorphic computing, as well as flexible solar cells with low-cost processes such as inkjet printing, ultrasonic nozzle, roll-to-roll coating. The rise of additive manufacturing provides even more opportunities to print electronics in automated and customizable ways. In this work, we will review the current technologies of printing electronics (including printed batteries, supercapacitors, fuel cells, and sensors), especially with 3D printing. In this age of ongoing AI revolution, the application of AI algorithms is discussed in terms of combining them with 3D printing and electronics printing for a future with automated optimization, sustainable design, and customizable and scalable manufacturing.

Chemistry↗

Cyanine-Incorporated Amorphous Polymeric Carbon Dots for Optical Reactive Oxygen Species Sensing

Reactive oxygen species (ROS) are common cellular oxidants that when overproduced by cellular stressors cause harm to cells. Detection of ROS is of utmost importance to understanding a wide variety of cellular function and toxicity mechanisms. Conventional ROS fluorescence assays involve using a single dye to visualize the ROS quantity. Herein, we describe ROS-sensitive, fluorescent-dye-incorporated carbon dots with dual fluorescence capabilities and good biocompatibility. Carbon dots (CDs) made of citric acid and urea were synthesized with incorporated cyanine-3-amine (Cy3), a bright red fluorescent dye, to create Cy3-CDs. Additionally, to get Cy3 into the ROS-sensitive form, this work demonstrated that Cy3 alone and Cy3 within carbon dots can be electrochemically reduced to their colorless ROS-sensitive form. Cy3, CDs, and Cy3-CDs are all responsive to additions of superoxide, leading to an increase in the fluorescence. Overall, this work examines how O 2 •– and additional oxidizers interact with CDs, Cy3, and Cy3-CDs, and molecular-level hypotheses are explored that will inform the design of future carbon dot-based ROS sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-Cost and Portable Biosensor Based on Monitoring Impedance Changes in Aptamer-Functionalized Nanoporous Anodized Aluminum Oxide Membrane

We report a low-cost, portable biosensor composed of an aptamer-functionalized nanoporous anodic aluminum oxide (NAAO) membrane and a commercial microcontroller chip-based impedance reader suitable for electrochemical impedance spectroscopy (EIS)-based sensing. The biosensor consists of two chambers separated by an aptamer-functionalized NAAO membrane, and the impedance reader is utilized to monitor transmembrane impedance changes. The biosensor is utilized to detect amodiaquine molecules using an amodiaquine-binding aptamer (OR7)-functionalized membrane. The aptamer-functionalized membrane is exposed to different concentrations of amodiaquine molecules to characterize the sensitivity of the sensor response. The specificity of the sensor response is characterized by exposure to varying concentrations of chloroquine, which is similar in structure to amodiaquine but does not bind to the OR7 aptamer. A commercial potentiostat is also used to measure the sensor response for amodiaquine and chloroquine. The sensing response measured using both the portable impedance reader and the commercial potentiostat showed a similar dynamic response and detection threshold. The specific and sensitive sensing results for amodiaquine demonstrate the efficacy of the low-cost and portable biosensor.

60 APPLIED LIFE SCIENCES↗

A mini-review on proton conduction of BaZrO 3 -based perovskite electrolytes

Abstract Proton conducting ceramics show promise in fuel cells, electrolyzers, permeation membranes, sensor applications, and membrane reactors. Among several types of materials that exhibit proton conduction, perovskite oxides show high proton conductivity at intermediate temperatures, presenting potential benefits for long-term use and lower costs for energy applications. Doped barium zirconate, BaZrO 3 , is a material that has shown high proton conductivity with encouraging chemical stability. Therefore, it is considered a promising material especially for proton-conducting solid oxide electrochemical cells. Although the proton conduction of doped BaZrO 3 has been extensively characterized, the specific phenomena behind its proton conduction are not fully understood. Only recently have specialized techniques and computational tools begun to elucidate the phenomena that determine the conduction properties of the material. In this mini review, an evaluation of the factors affecting the proton conductivity of doped BaZrO 3 perovskites and the phenomena governing variations in proton concentration and mobility are presented. Special attention is given to proton interactions with dopants and their resulting effect on hydration and transport properties. Technical strategies are provided to give some guidance on the development of protonic ceramics in energy conversion applications.

08 HYDROGEN↗

Influence of the molecular weight and size distribution of PSS on mixed ionic-electronic transport in PEDOT:PSS

The commercially available polyelectrolyte complex poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) is ubiquitous in organic and hybrid electronics. As such, it has often been used as a benchmark material for fundamental studies and the development of new electronic devices. Yet, most studies on PEDOT:PSS have focused on its electronic conductivity in dry environments, with less consideration given to its ion transport, coupled ionic-electronic transport, and charge storage properties in aqueous environments. These properties are essential for applications in bioelectronics (sensors, actuators), charge storage devices, and electrochromic displays. Importantly, past studies on mixed ionic-electronic transport in PEDOT:PSS neglected to consider how the molecular structure of PSS affects mixed ionic-electronic transport. Herein, we therefore investigated the effect of the molecular weight and size distribution of PSS on the electronic properties and morphology of PEDOT:PSS both in dry and aqueous environments, and overall performance in organic electrochemical transistors (OECTs). Using reversible addition–fragmentation chain transfer (RAFT) polymerization with two different chain transfer agents, six PSS samples with monomodal, narrow (D = 1.1) and broad (D = 1.7) size distributions and varying molecular weights were synthesized and used as matrices for PEDOT. We found that using higher molecular weight of PSS (Mn = 145 kg mol –1 ) and broad dispersity led to OECTs with the highest transconductance (up to 16 mS) and [μC*] values (~140 F cm –1 V –1 s –1 ) in PEDOT:PSS, despite having a lower volumetric capacitance (C* = 35 ± 4 F cm –3 ). The differences were best explained by studying the microstructure of the films by atomic force microscopy (AFM). We found that heterogeneities in the PEDOT:PSS films (interconnected and large PEDOT- and PSS-rich domains) obtained from high molecular weight and high dispersity PSS led to higher charge mobility (μOECT ~4 cm 2 V –1 s –1 ) and hence transconductance. Furthermore, these studies highlight the importance of considering molecular weight and size distribution in organic mixed ionic-electronic conductor, and could pave the way to designing high performance organic electronics for biological interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensing strategies for toxic vapor detection

This work was motivated by the recommendations of the American Conference of Governmental Industrial Hygienists (ACGIH) that threshold limits for hydrazine, H2N-NH2 in air be lowered from 100 to 10 parts-per-billion (ppb) concentration levels. Hydrazine is one of the high-energy propellants used in large volumes in Space Shuttle, Titan, payloads, and other aerospace operations. Since analytical methods presently available for hydrazine detection and/or determination do not satisfy such low levels of detection, the ultimate goal of this research is the development and characterization of a portable and compact chemical sensor ideally capable to detect (in real time) 1 ppb of hydrazine, continuously and reversibly. The laboratory prototype developed as part of this project is comprised of: (1) a reactor part in which H2N-NH2 reacts, generating chemiluminescence emission, with tris(2,2'-bipyridine)ruthenium(III), which is immobilized on an ion-exchange polymeric materials of a perfluorinated hydrocarbon containing sulfonate groups as exchange centers (Nafion); (2) an electrochemical three-electrode cell posed at a potential at which the immobilized ruthenium complex could be reoxidized to the 3-oxidation state (as to provide reversible and continuous detection); and (3) a low power consumption photomultiplier tube to collect and quantitatively integrate the emitted photons with the help of auxiliary electronics and readout device.

Mottola, Horacio A.↗

Tuning Surface Acidity of Mixed Conducting Electrodes: Recovery of Si‐Induced Degradation of Oxygen Exchange Rate and Area Specific Resistance

Abstract Metal oxides are an important class of functional materials, and for many applications, ranging from solid oxide fuel/electrolysis cells, oxygen permeation membranes, and oxygen storage materials to gas sensors (semiconducting and electrolytic) and catalysts, the interaction between the surface and oxygen in the gas phase is central. Ubiquitous Si‐impurities are known to impede this interaction, commonly attributed to the formation of glassy blocking layers on the surface. Here, the surface oxygen exchange coefficient ( k chem ) is examined for Pr 0.1 Ce 0.9 O 2‐δ (PCO), a model mixed ionic electronic conductor, via electrical conductivity relaxation measurements, and the area‐specific resistance (ASR) by electrochemical impedance spectroscopy. It is demonstrated that even low silica levels, introduced by infiltration, depress k chem by a factor 4000, while the ASR increases 40‐fold and we attribute this to its acidity relative to that of PCO. The ability to fully regenerate the poisoned surface by the subsequent addition of basic Ca‐ or Li‐species is further shown. This ability to not only recover Si‐poisoned surfaces by tuning the relative surface acidity of an oxide surface, but subsequently outperform the pre‐poisoned response, promises to extend the operating life of materials and devices for which the catalytic oxygen/solid interface reaction is central.

30 DIRECT ENERGY CONVERSION↗

Tethered Balloon System Ozone Profiles during CoURAGE Summer Intensive Operational Period Field Campaign Report

During the summer IOP, the small ARM field campaign CRGTBSO3 collected measurements to gain an improved understanding of differences between the atmospheric composition in and just above the marine layer at the CoURAGE TBS site near the eastern shore of Chesapeake Bay. CRGTBSO3 included guest instrumentation with ozone (O 3 ) profile measurements on the TBS and surface O3 and meteorological measurements at the TBS site. An En-Sci 2Z electrochemical cell (ECC) ozonesonde (Komhyr 1969, 1986, Witte et al. 2018) was included on the TBS. The ozonesonde was connected to an InterMet iMet-4RSB radiosonde, and the overall data collected included vertical profiles of ozone, relative humidity, temperature, pressure, and altitude. The CRGTBSO3 iMet-4 radiosonde data is identical to that of the iMet in the Tethered Balloon System Merged Data Product (TBSMERGED; Gaustad and Dexheimer 2025). The TBSMERGED data product also includes meteorological data from a different sensor, the iMet XQ2. In some cases, the iMet XQ2 relative humidity (RH) data may be more accurate than the iMet-4, such as for some instances when the iMet-4 RH data stays at 100% for an extended period throughout a profile.

54 ENVIRONMENTAL SCIENCES↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amplifying Electrochemical Indicators

Dendrimeric reporter compounds have been invented for use in sensing and amplifying electrochemical signals from molecular recognition events that involve many chemical and biological entities. These reporter compounds can be formulated to target specific molecules or molecular recognition events. They can also be formulated to be, variously, hydrophilic or amphiphilic so that they are suitable for use at interfaces between (1) aqueous solutions and (2) electrodes connected to external signal-processing electronic circuits. The invention of these reporter compounds is expected to enable the development of highly miniaturized, low-power-consumption, relatively inexpensive, mass-producible sensor units for diverse applications.

Fan, Wenhong↗

P-Type Electrochemical Doping Can Occur by Cation Expulsion in a High Performing Polymer for Organic Electrochemical Transistors

We investigate the mechanism of ion-dependent charge compensation during electrochemical oxidation (doping) of the model mixed ionic/electronic transporting polythiophene derivative poly(3-{[2-(2-methoxyethoxy)ethoxy]methyl}thiophene-2,5-diyl) (P3MEEMT). Using a combination of electrochemical quartz microbalance gravimetry and glow discharge optical emission spectroscopy, we show that charge compensation during polymer redox processes proceeds via a cation-dependent mechanism. For p-type polymer oxidation in certain electrolytes, charge compensation is achieved by both eventual injection of anions into the film, as well as initial expulsion of cations from the film. We compare doping mechanisms for a variety of electrolyte salts including potassium chloride, tetrabutylammonium chloride, potassium hexafluorophosphate (KPF6), and tetrabutylammonium hexafluorophosphate. For the electrolyte KPF6, both the cations and anions coexist in the water-swelled polymer even prior to application of electrical bias. Our data indicate that electrochemical doping (hole injection into the polymer and ionic charge compensation) proceeds via the following mechanism: (1) hydration of the neutral film by electrolyte (water, cations, anions), (2) cation (K+) expulsion from the film upon initial application of an oxidative bias, and (3) anion injection into the film at higher oxidation/doping levels (>~2 × 1020/cm3). Understanding the mechanism of charge compensation during the doping process should allow for the design of improved mixed ionic/electronic conductors for use in applications ranging from organic supercapacitors and redox flow batteries to bioelectronic sensors, thermoelectrics, and devices for neuromorphic computing.

Flagg, Lucas Q.↗

Sodium, Silver and Lithium-Ion Conducting β''-Alumina + YSZ Composites, Ionic Conductivity and Stability

Na-β''-alumina (Na 2 O.~6Al 2 O 3 ) is known to be an excellent sodium ion conductor in battery and sensor applications. In this study we report fabrication of Na- β''-alumina + YSZ dual phase composite to mitigate moisture and CO 2 corrosion that otherwise can lead to degradation in pure Na-β''-alumina conductor. Subsequently, we heat-treated the samples in molten AgNO 3 and LiNO3 to respectively form Ag-β''-alumina + YSZ and Li-β''-alumina + YSZ to investigate their potential applications in silver- and lithium-ion solid state batteries. Ion exchange fronts were captured via SEM and EDS techniques. Their ionic conductivities were measured using electrochemical impedance spectroscopy. Both ion exchange rates and ionic conductivities of these composite ionic conductors were firstly reported here and measured as a function of ion exchange time and temperature.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record↗

Silica: ubiquitous poison of metal oxide interfaces

In this review, we consider the detrimental effects of Si-contamination on electrochemical applications, broadly conceived, in which both ions and electrons play key roles in device operation and where exchange of oxygen between the gas and solid phase is likewise essential for operation.

30 DIRECT ENERGY CONVERSION↗

Experimental studies and applications of vanadium oxides.

The electrical and electrochemical properties of V-5 and V-7 vanadium oxides were investigated. The effects of pressure, temperature and moisture on the bulk resistivity of the oxides in powder, sintered, and crystalline form were determined, and the static and dynamic volt-ampere characteristics were obtained. Sintered samples tested showed better electrical stability than the compressed powder samples. Two types of commercially available vanadium pentoxide were heat-treated to obtain various crystalline oxide forms which were mounted on alumina substrates and terminated by thick-film conductors for making electrical connections. Indications are that these materials could have applications as sensors, critical-temperature resistors, high-speed switches, and temperature-compensation elements in hybrid microelectronic circuits.

Williams, L., Jr.↗

Propagation of Radiosonde Pressure Sensor Errors to Ozonesonde Measurements

Several previous studies highlight pressure (or equivalently, pressure altitude) discrepancies between the radiosonde pressure sensor and that derived from a GPS flown with the radiosonde. The offsets vary during the ascent both in absolute and percent pressure differences. To investigate this problem further, a total of 731 radiosonde-ozonesonde launches from the Southern Hemisphere subtropics to Northern mid-latitudes are considered, with launches between 2005 - 2013 from both longer-term and campaign-based intensive stations. Five series of radiosondes from two manufacturers (International Met Systems: iMet, iMet-P, iMet-S, and Vaisala: RS80-15N and RS92-SGP) are analyzed to determine the magnitude of the pressure offset. Additionally, electrochemical concentration cell (ECC) ozonesondes from three manufacturers (Science Pump Corporation; SPC and ENSCI-Droplet Measurement Technologies; DMT) are analyzed to quantify the effects these offsets have on the calculation of ECC ozone (O3) mixing ratio profiles (O3MR) from the ozonesonde-measured partial pressure. Approximately half of all offsets are 0.6 hPa in the free troposphere, with nearly a third 1.0 hPa at 26 km, where the 1.0 hPa error represents 5 persent of the total atmospheric pressure. Pressure offsets have negligible effects on O3MR below 20 km (96 percent of launches lie within 5 percent O3MR error at 20 km). Ozone mixing ratio errors above 10 hPa (30 km), can approach greater than 10 percent ( 25 percent of launches that reach 30 km exceed this threshold). These errors cause disagreement between the integrated ozonesonde-only column O3 from the GPS and radiosonde pressure profile by an average of +6.5 DU. Comparisons of total column O3 between the GPS and radiosonde pressure profiles yield average differences of +1.1 DU when the O3 is integrated to burst with addition of the McPeters and Labow (2012) above-burst O3 column climatology. Total column differences are reduced to an average of -0.5 DU when the O3 profile is integrated to 10 hPa with subsequent addition of the O3 climatology above 10 hPa. The RS92 radiosondes are superior in performance compared to other radiosondes, with average 26 km errors of -0.12 hPa or +0.61 percent O3MR error. iMet-P radiosondes had average 26 km errors of -1.95 hPa or +8.75 percent O3MR error. Based on our analysis, we suggest that ozonesondes always be coupled with a GPS-enabled radiosonde and that pressure-dependent variables, such as O3MR, be recalculated-reprocessed using the GPS-measured altitude, especially when 26 km pressure offsets exceed 1.0 hPa 5 percent.

pressure measurements↗