Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Three-dimensional theory of superradiant free-electron lasers

The solitonlike superradiant regime of free-electron lasers (FEL) offers a promising path towards ultrashort pulses, beyond the natural limit dictated by the bandwidth of the high-gain FEL instability. In this work we present a three-dimensional theory of the superradiant regime, including the effects of beam emittance and energy spread. Our work takes advantage of recent developments in nonlinear FEL theory to provide a fully analytical description of solitonlike superradiance. Our theory proves the existence of a diffraction-dominated steady-state regime in which the superradiant peak power grows indefinitely while leaving the pulse duration and on-axis intensity almost unchanged. These results are in excellent agreement with three-dimensional simulations and are supported by recent experimental results at the Linac Coherent Light Source. This work advances nonlinear FEL theory and provides a theoretical framework for the next generation of attosecond x-ray FELs. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V

A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at the beam center region with an irradiation temperature around 120 oC. Tensile tests showed increased hardness and a large decrease in ductility for the dual a+ß-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near a-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each a-phase grain. The ß-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated ?-phase precipitation in an advanced formation stage. The radiation-induced ?-phase transformation in the ß-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less ß-phase.google scho

Tensile Test, titanium, acclerator, proton beam↗

A New Design of a Dressed Balloon Cavity with Superior Mechanical Properties

Superconducting spoke cavities are prone to multipactor - resonant raise of a number of electrons due to secondary emission. Recently proposed and tested by TRIUMF balloon-type spoke cavity showed an outstanding multipactor (MP) suppression property but unfortunately serious Q degradation at high fields. A new fully developed design of a dressed balloon cavity which can be used for any proton linac SSR2 section is developed. The design incorporates additional EP ports for high Q-factor demonstration. Superior properties are demonstrated, such as effective multipactor suppression, 40% lower Lorentz force coefficient, zero sensitivity to external pressure. This paper presents the results of coupled structural Multiphysics analysis, and engineering design of the dressed balloon cavity with EP ports.

43 PARTICLE ACCELERATORS↗

The chemRIXS Instrument for Solution-Phase Resonant Inelastic X-ray Scattering at the Linac Coherent Light Source

The chemRIXS instrument at the Linac Coherent Light Source (LCLS) offers new opportunities for studying solution-phase systems with time-resolved soft X-ray spectroscopic methods such as resonant inelastic X-ray scattering (RIXS) using the recently commissioned high-repetition-rate LCLS-II X-ray free electron laser. The orders-of-magnitude X-ray flux improvement provided by the superconducting accelerator, combined with corresponding advances in the optical laser system and the liquid jet recirculation system, enables studies on dilute systems with high signal-to-noise compared to what was possible with the LCLS-I copper accelerator. These capabilities open up time-resolved X-ray absorption spectroscopy and RIXS to entirely new classes of samples, as well as enabling the development of new soft X-ray spectroscopic methods on liquid samples. An overview of the beamline components and the first LCLS-II commissioning results are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.

43 PARTICLE ACCELERATORS↗

Spectral broadening and pulse shaping in the deep ultraviolet

Here, we report the generation and shaping of ∼20 femtosecond pulses in the deep ultraviolet (DUV). Our approach combines spectral broadening in a stretched hollow-core fiber with compression and shaping via an acousto-optic modulator-based pulse shaper. The pulse shaper allows for automatic compression, useful for in-air delivery of pulses to two-dimensional (2D) spectroscopy and other time-resolved experiments. Unlike previous DUV pulse generation schemes that lack phase stability, our method enables programmable generation of phase-locked pulse-pairs with attosecond-level stability. We demonstrate pulse characterization via self-diffraction frequency-resolved optical gating and dispersion scan methods in the DUV and validate performance through a pump-probe experiment resolving electronic dynamics on attosecond timescales.

Codere, Julia [Stony Brook Univ., NY (United State↗

Progress in Hybrid Plasma Wakefield Acceleration

Plasma wakefield accelerators can be driven either by intense laser pulses (LWFA) or by intense particle beams (PWFA). A third approach that combines the complementary advantages of both types of plasma wakefield accelerator has been established with increasing success over the last decade and is called hybrid LWFA→PWFA. Essentially, a compact LWFA is exploited to produce an energetic, high-current electron beam as a driver for a subsequent PWFA stage, which, in turn, is exploited for phase-constant, inherently laser-synchronized, quasi-static acceleration over extended acceleration lengths. The sum is greater than its parts: the approach not only provides a compact, cost-effective alternative to linac-driven PWFA for exploitation of PWFA and its advantages for acceleration and high-brightness beam generation, but extends the parameter range accessible for PWFA and, through the added benefit of co-location of inherently synchronized laser pulses, enables high-precision pump/probing, injection, seeding and unique experimental constellations, e.g., for beam coordination and collision experiments. We report on the accelerating progress of the approach achieved in a series of collaborative experiments and discuss future prospects and potential impact.

43 PARTICLE ACCELERATORS↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗

Ultrafast Suppression of the Ferroelectric Instability in KTaO 3

We use an x-ray free-electron laser to study the lattice dynamics following photoexcitation with ultrafast near-UV light (wavelength 266 nm, 50 fs pulse duration) of the incipient ferroelectric potassium tantalate, KT a O 3 . By probing the lattice dynamics corresponding to multiple Brillouin zones through the x-ray diffuse scattering with pulses from the Linac Coherent Light Source (LCLS) (wavelength 1.3 Å and < 10 fs pulse duration), we observe changes in the diffuse intensity associated with a hardening of the transverse acoustic phonon branches along Γ to X and Γ to M. Using force constants from density functional theory, we fit the quasiequilibrium intensity and obtain the instantaneous lattice temperature and density of photoexcited charge carriers. Additionally, the density functional theory calculations demonstrate that photoexcitation transfers charge from oxygen 2p derived π-bonding orbitals to Ta 5d derived antibonding orbitals, further suppressing the ferroelectric instability and increasing the stability of the cubic, paraelectric structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Shake-Down Spectroscopy as State- and Site-Specific Probe of Ultrafast Chemical Dynamics

Tracking the multifarious ultrafast electronic and structural changes occurring in a molecule during a photochemical transformation is a challenging endeavor that benefits from recent experimental and computational progress in time-resolved techniques. Measurements of valence electronic states, which provide a global picture of the bonding structure of the molecule, and core electronic states, which provide insight into the local environment, traditionally require different approaches and are often studied separately. Here, we demonstrate that X-ray pulses from a seeded free-electron laser (FEL) enable the measurement of high-resolution, time-resolved X-ray photoelectron spectra (XPS) that capture weak satellite states resulting from shake-down processes in a valence-excited molecule. This approach effectively combines the advantages of both valence- and core-state investigations. We applied this method to investigate photoexcited CS2 molecules, where the role of internal conversion (IC) and intersystem crossing (ISC) in determining the predissociation dynamics is controversial. We present XPS spectra from photoexcited CS2, obtained at the FERMI FEL. High-resolution measurements, compared to the corresponding spectra obtained from accurate multireference quantum chemical calculations, reveal that shake-down satellite channels are highly sensitive to both valence electronic and geometric changes. Previous studies of the predissociation dynamics have led to uncertain assignments of the branching between singlet and triplet excited states. We derive a propensity rule that demonstrates the spin-selectivity of the shake-downs. This selectivity allows us to unequivocally assign contributions from the bright and dark singlet excited states, with populations tracked along the predissociation dynamic pathway.

Thompson, Henry J. [Univ. of Southampton (United K↗

Proton and electron RLA optics design

We describe optics designs of the key components of proton and electron Recirculating Linear Accelerators (RLAs). They are presented in the context of a high-power hadron accelerator being considered at ORNL and a CEBAF electron energy doubling study, FFA@CEBAF, being developed at Jefferson Lab. Both concepts rely on the Fixed-Field Alternating gradient (FFA) arc optics designs where multiple beam passes are transported by a single beam line. Some of the main challenges of the optics design are in synchronization and orbital and linear optics match of the individual passes with the linac straight. To minimize the complexity of the matching sections and make them more practical, it is preferable to complete as much of the orbital and optical match as possible within a single beam line using the FFA approach. The adiabatic matching technique proposed earlier is one such solution, but it requires a large number of cells. We present a much shorter matching section design based on another approach. A compact dog-leg-type section of several bending dipoles and quadrupoles is used to suppress the orbital offset and dispersion coming out of a periodic cell. Additional quadrupoles are used in the section to keep the beta functions under control and simplify their subsequent match to the linac. Initial beam tracking results are presented.

Benesch, J.↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗