Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.

43 PARTICLE ACCELERATORS↗

Spectral broadening and pulse shaping in the deep ultraviolet

Here, we report the generation and shaping of ∼20 femtosecond pulses in the deep ultraviolet (DUV). Our approach combines spectral broadening in a stretched hollow-core fiber with compression and shaping via an acousto-optic modulator-based pulse shaper. The pulse shaper allows for automatic compression, useful for in-air delivery of pulses to two-dimensional (2D) spectroscopy and other time-resolved experiments. Unlike previous DUV pulse generation schemes that lack phase stability, our method enables programmable generation of phase-locked pulse-pairs with attosecond-level stability. We demonstrate pulse characterization via self-diffraction frequency-resolved optical gating and dispersion scan methods in the DUV and validate performance through a pump-probe experiment resolving electronic dynamics on attosecond timescales.

Codere, Julia [Stony Brook Univ., NY (United State↗

Progress in Hybrid Plasma Wakefield Acceleration

Plasma wakefield accelerators can be driven either by intense laser pulses (LWFA) or by intense particle beams (PWFA). A third approach that combines the complementary advantages of both types of plasma wakefield accelerator has been established with increasing success over the last decade and is called hybrid LWFA→PWFA. Essentially, a compact LWFA is exploited to produce an energetic, high-current electron beam as a driver for a subsequent PWFA stage, which, in turn, is exploited for phase-constant, inherently laser-synchronized, quasi-static acceleration over extended acceleration lengths. The sum is greater than its parts: the approach not only provides a compact, cost-effective alternative to linac-driven PWFA for exploitation of PWFA and its advantages for acceleration and high-brightness beam generation, but extends the parameter range accessible for PWFA and, through the added benefit of co-location of inherently synchronized laser pulses, enables high-precision pump/probing, injection, seeding and unique experimental constellations, e.g., for beam coordination and collision experiments. We report on the accelerating progress of the approach achieved in a series of collaborative experiments and discuss future prospects and potential impact.

43 PARTICLE ACCELERATORS↗

Cyclotron resonance accelerators for industrial applications

Here, this paper describes novel configurations for cyclotron resonance acceleration of electrons and ions that have several attractive features including: a compact robust room-temperature single-cell RF cavity as the accelerator structure; and continuous high current accelerated un-bunched beam output with self-scanning, obviating need for a separate beam scanner. An electron accelerator version, the electron Cyclotron Resonance Accelerator (eCRA), is under development to be an efficient source for high power electron and x-ray beams for medical, research, sterilization, and National Security applications, so as to replace radioactive materials. An ion accelerator version, the ion Cyclotron Auto-Resonance Accelerator (iCARA) is described here, suggesting its potential to produce, as an example, a high-current multi-MeV beam of deuterons which could be highly competitive with that produced either with linacs or cyclotrons. Such a deuteron beam could produce a high flux of fast neutrons via deuteron stripping, for applications including the transmutation of used nuclear fuel, material studies relevant for a fusion reactor inner wall, tritium breeding and medical isotope production. For the high-current, high efficiency simulated performance for eCRA and iCARA as described in this paper, the particle beams produced may not exhibit the low emittance values that are important for most discovery research. Rather, the beams could be useful for industrial applications where higher emittance and some energy spread can be tolerated, in favor of high beam power.

43 PARTICLE ACCELERATORS↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗

Ultrafast Suppression of the Ferroelectric Instability in KTaO 3

We use an x-ray free-electron laser to study the lattice dynamics following photoexcitation with ultrafast near-UV light (wavelength 266 nm, 50 fs pulse duration) of the incipient ferroelectric potassium tantalate, KT a O 3 . By probing the lattice dynamics corresponding to multiple Brillouin zones through the x-ray diffuse scattering with pulses from the Linac Coherent Light Source (LCLS) (wavelength 1.3 Å and < 10 fs pulse duration), we observe changes in the diffuse intensity associated with a hardening of the transverse acoustic phonon branches along Γ to X and Γ to M. Using force constants from density functional theory, we fit the quasiequilibrium intensity and obtain the instantaneous lattice temperature and density of photoexcited charge carriers. Additionally, the density functional theory calculations demonstrate that photoexcitation transfers charge from oxygen 2p derived π-bonding orbitals to Ta 5d derived antibonding orbitals, further suppressing the ferroelectric instability and increasing the stability of the cubic, paraelectric structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The time-resolved atomic, molecular and optical science instrument at the Linac Coherent Light Source

The newly constructed time-resolved atomic, molecular and optical science instrument (TMO) is configured to take full advantage of both linear accelerators at SLAC National Accelerator Laboratory, the copper accelerator operating at a repetition rate of 120 Hz providing high per-pulse energy as well as the superconducting accelerator operating at a repetition rate of about 1 MHz providing high average intensity. Both accelerators power a soft X-ray free-electron laser with the new variable-gap undulator section. With this flexible light source, TMO supports many experimental techniques not previously available at LCLS and will have two X-ray beam focus spots in line. Thereby, TMO supports atomic, molecular and optical, strong-field and nonlinear science and will also host a designated new dynamic reaction microscope with a sub-micrometer X-ray focus spot. The flexible instrument design is optimized for studying ultrafast electronic and molecular phenomena and can take full advantage of the sub-femtosecond soft X-ray pulse generation program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Power Solid Target for Positron Source at CEBAF

The progress in the development of a polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is presented. The polarized positron beam is generated by a high current polarized electron beam (>1 mA @ 120 MeV) via bremsstrahlung radiation and e+e- pair production in the tungsten target. The simulations show that using an optimized target and positron beamline, the positron injector can provide a cw positron beam with a current larger than 50 nA and a polarization as large as 60%. Injected into the North Linac of CEBAF at an energy of 123 MeV, the positron beam can reach a maximum energy of 12 GeV to perform a rich experimental program. The results of the thermal and structural FEA analysis of the heat load in the target are presented, as well as the simulation results of radiation damage in the target. The performed and planned target material fatigue and radiation damage tests are discussed. This work is supported by the U.S. DOE, Office of Science, Office of Nuclear Physics, Contract No. DE-AC05-06OR23177 and the European Union?s Horizon 2020 research and innovation program under grant agreement No. 824093.

Ushakov, Andriy↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Shake-Down Spectroscopy as State- and Site-Specific Probe of Ultrafast Chemical Dynamics

Tracking the multifarious ultrafast electronic and structural changes occurring in a molecule during a photochemical transformation is a challenging endeavor that benefits from recent experimental and computational progress in time-resolved techniques. Measurements of valence electronic states, which provide a global picture of the bonding structure of the molecule, and core electronic states, which provide insight into the local environment, traditionally require different approaches and are often studied separately. Here, we demonstrate that X-ray pulses from a seeded free-electron laser (FEL) enable the measurement of high-resolution, time-resolved X-ray photoelectron spectra (XPS) that capture weak satellite states resulting from shake-down processes in a valence-excited molecule. This approach effectively combines the advantages of both valence- and core-state investigations. We applied this method to investigate photoexcited CS2 molecules, where the role of internal conversion (IC) and intersystem crossing (ISC) in determining the predissociation dynamics is controversial. We present XPS spectra from photoexcited CS2, obtained at the FERMI FEL. High-resolution measurements, compared to the corresponding spectra obtained from accurate multireference quantum chemical calculations, reveal that shake-down satellite channels are highly sensitive to both valence electronic and geometric changes. Previous studies of the predissociation dynamics have led to uncertain assignments of the branching between singlet and triplet excited states. We derive a propensity rule that demonstrates the spin-selectivity of the shake-downs. This selectivity allows us to unequivocally assign contributions from the bright and dark singlet excited states, with populations tracked along the predissociation dynamic pathway.

Thompson, Henry J. [Univ. of Southampton (United K↗

Proton and electron RLA optics design

We describe optics designs of the key components of proton and electron Recirculating Linear Accelerators (RLAs). They are presented in the context of a high-power hadron accelerator being considered at ORNL and a CEBAF electron energy doubling study, FFA@CEBAF, being developed at Jefferson Lab. Both concepts rely on the Fixed-Field Alternating gradient (FFA) arc optics designs where multiple beam passes are transported by a single beam line. Some of the main challenges of the optics design are in synchronization and orbital and linear optics match of the individual passes with the linac straight. To minimize the complexity of the matching sections and make them more practical, it is preferable to complete as much of the orbital and optical match as possible within a single beam line using the FFA approach. The adiabatic matching technique proposed earlier is one such solution, but it requires a large number of cells. We present a much shorter matching section design based on another approach. A compact dog-leg-type section of several bending dipoles and quadrupoles is used to suppress the orbital offset and dispersion coming out of a periodic cell. Additional quadrupoles are used in the section to keep the beta functions under control and simplify their subsequent match to the linac. Initial beam tracking results are presented.

Benesch, J.↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗

FFA@CEBAF beam transport error and tolerance simulation studies

The Continuous Electron Beam Accelerator Facility (CEBAF) is a 12 GeV recirculating electron accelerator at the Thomas Jefferson National Accelerator Facility (JLAB). Major upgrades to the accelerator are being investigated which include a new 650 MeV injection beamline and state-of-the-art fixed-field alternating (FFA) gradient recirculation arcs. The upgrade will extend the energy of the electron beam to over 20 GeV. In this paper, we provide an error and tolerance simulation study of the amended beam optics transport of the existing accelerator tuned for 22 GeV operation. The study is conducted with the particle tracking codes elegant and Bmad in two parts. In the first part, we treat each section of the accelerator (electromagnetic arcs and linacs) modularly with ideal conditions at the beginning. The second part is a pseudo start-to-end (S2E) simulation with accumulated errors propagating from one beamline to the next.

Accelerator Physics↗

Observation of photo-induced plasmon–phonon coupling in PbTe via ultrafast x-ray scattering

We report the observation of photo-induced plasmon–phonon coupled modes in the group IV–VI semiconductor PbTe using ultrafast x-ray diffuse scattering at the Linac Coherent Light Source. We measure the near-zone-center excited-state dispersion of the heavily screened longitudinal optical (LO) phonon branch as extracted from differential changes in x-ray diffuse scattering intensity following above bandgap photoexcitation. We suggest that upon photoexcitation, the LO phonon-plasmon coupled (LOPC) modes themselves become coupled to longitudinal acoustic modes that drive electron band shifts via acoustic deformation potentials and possibly to low-energy single-particle excitations within the plasma and that these couplings give rise to displacement-correlations that oscillate in time with a period given effectively by the heavily screened LOPC frequency.

36 MATERIALS SCIENCE↗

Understanding the superconductivity and charge density wave interaction through quasi-static lattice fluctuations

In unconventional superconductors, coupled charge and lattice degrees of freedom can manifest in ordered phases of matter that are intertwined. In the cuprate family, fluctuating short-range charge correlations can coalesce into a longer-range charge density wave (CDW) order which is thought to intertwine with superconductivity, yet the nature of the interaction is still poorly understood. Here, by measuring subtle lattice fluctuations in underdoped YBa 2 Cu 3 O 6+y on quasi-static timescales (thousands of seconds) through X-ray photon correlation spectroscopy, we report sensitivity to both superconductivity and CDW. The atomic lattice shows remarkably faster relaxational dynamics upon approaching the superconducting transition at T c ≈ 65 K. By tracking the momentum dependence, we show that the intermediate scattering function almost monotonically scales with the relaxation distance of atoms away from their average positions above T c and in the presence of the CDW state, while this peculiar trend is reversed for other temperatures. These observations are consistent with an incipient CDW stabilized by local strain. This work provides insights into the crucial role of relaxational atomic fluctuations for understanding the electronic physics cuprates, which are inherently disordered due to carrier doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlation-driven attosecond photoemission delay in the plasmonic excitation of C60 fullerene

Extreme light confinement in plasmonic nanosystems enables novel applications in photonics, sensor technology, energy harvesting, biology, and quantum information processing. Fullerenes represent an extreme case for nanoplasmonics: they are sub-nanometer carbon- based molecules showing high-energy and ultrabroad plasmon resonances, however the fundamental mechanisms driving the plasmonic response and the corresponding collective electron dynamics are still elusive. Here, we uncover the dominant role of electron correlations in the dynamics of the giant plasmon resonance (GPR) of the sub-nanometer system C60 by employing attosecond photoemission chronoscopy. We find a characteristic photoemission delay of up to about 300 attoseconds that is purely induced by coherent large-scale electron correlations in the plasmonic potential. These results provide novel insights into the nature of the plasmon resonances in sub-nanometer systems and open new perspectives for advancing nanoplasmonic applications.

Biswas, Shubhadeep [SLAC National Accelerator Labo↗