Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Experimental SF6/-//SF6 and Cl/-//CFC13 electron-attachment cross sections in the energy range 0-200 meV

Experimental cross sections for the electron-attachment processes for SF6(-)/SF6 and Cl(-)/CFl3 are reported in the energy range 0-200 meV by normalizing each attachment line shape to measurement of a thermal rate coefficient. When the same ion states are detected, good agreement is found between present values, for which a monoenergetic electron source is used, and swarm-unfolded results. The present data constitute a new limit for cross sections reported at high resolution at the lowest electron energy.

Chutjian, A.↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Manipulating the Second Coordination Shell of Single-Atom Fe for Enhanced Fenton Reaction

While current methods use oxidizable metals as electron donors to effectively reduce Fe 3+ , they suffer from the irreversible oxidation of these metals, ultimately compromising the catalyst’s longevity. To address this challenge, we engineered the second coordination shell of a single-atom Fe center by doping boron (B) onto a graphene-based support (Fe 1 /B-graphene) and utilized H 2 O 2 as the electron source for efficient Fe 2+ regeneration. Experimental results, supported by theoretical calculations, revealed that the Fe–O–B motif functions like a micro galvanic cell, with intermediary O atoms facilitating electron transfer between electrodes. Specifically, electrons consumed during H 2 O 2 activation at Fe 1 sites (positive electrode) are replenished by electrons extracted from H 2 O 2 at B atoms (negative electrode), where the activation energy for H 2 O 2 oxidation is significantly lower than that at Fe 1 sites. This study offers inspirational insights into the design of Fenton catalysts through precise regulation of the second coordination shell, demonstrating the potential of tailoring the outer coordination environment of single-atom catalysts to enhance catalytic performance across various reactions.

36 MATERIALS SCIENCE↗

Theoretical Coupling of Free-Flowing Ions and Magnetically Insulated Electrons

Magnetic insulation of electrons prevents losses and can be applied to generating radiation or electron sources for high current and high power applications. Ion emission from the anode may degrade magnetic insulation. We develop equilibrium theory, self-consistently coupling magnetically insulated electron flow with free-flowing injected ions. Generally, ion injection is self-limiting from space charge; however, once insulation strength drops below about 1.2x the magnetic insulation threshold, ion space-charge limits vanish. Further, the gap effectively short-circuits and the electron flow layer asymptotically approaches the anode. In this regime a quasineutral, nonthermal plasma manifests, effectively reducing gap distance and suggesting quasiequilibrium gap closure evolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

A Dual 5T Superconducting Magnet System for the Brookhaven National Lab Electron Beam Ion Source

Cryomagnetics has delivered an upgraded magnet system to the Brookhaven National Laboratory's RHIC Electron Beam Ion Source project. This consists of two 2.25-m long, 215-mm room temperature bore 5T solenoids separated by 20 cm. The initial system used a single PT-415RM cryocooler but was unstable a long term. As a result, the new system adds a second SHI cryocooler, which produces much higher recondensing margins.

43 PARTICLE ACCELERATORS↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Comment on "Table-Top Laser-Based Source of Femtosecond, Collimated, Ultrarelativistic Positron Beams"

Sarri et al. have reported the generation of low divergence (~3 mrad), high-density (10 14 cm –3 ) positron beams using millimeter-scale converter targets and a 50 pC, 200 MeV laser-wakefield accelerated (LWFA) electron source. It was argued that the positron divergence was dominated by the pair-production birth cone angle $θ_{e+} ≈ 1/γ_{e–}$. The small, energy-independent divergence value was used to infer a positron beam density of 2 × 10 14 cm –3 from a 4.2 mm Ta converter target where the divergence and yield measurements agreed with their Monte Carlo (MC) simulations. We have repeated these simulations using experimental conditions and disagree with the reported density, divergence, and yield values by up to factors > 50. In our work, we find that a divergence on the order of milliradian is not physical and can only be achieved if inelastic particle scattering is omitted in the calculations.

47 OTHER INSTRUMENTATION↗

A Non-destructive Magnetic Momentum Monitor Using a TE011 Cavity

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam. The bunched beam cooler complex consists of a high current magnetized electron source, an energy recovery linac, a circulating ring, and a pair of long solenoids where the cooling takes place. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we will show the mechanism and scaling law of this device, as well as the design and testing results of the prototype cavity.

Guo, Jiquan↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗

Hot Electron Scaling and Energy Coupling In Nonlinear Laser Plasma Interactions

Energy conversion from high power lasers to energetic hot electrons is a fundamental phenomenon in laser-plasma interactions. At laser intensities above a few times 10 14 W/cm 2 , nonlinear laser-plasma interactions lead to the generation of hot electrons with a broad energy distribution at typical temperatures of 10’s – 100’s kilo-electron-volt (keV). The fraction of laser energy transferred to hot electrons, their energy distribution and energy coupling efficiency to the targets are strongly affected by the laser intensity, wavelength and the plasma condition. Most investigations to date that are related to the fusion of high-energy-density laboratory plasmas (HEDLP) are carried out with relatively moderate laser intensity and lower laser wavelength to minimize hot electron generation, as electron preheating can degrade the fuel assembly. An alternative fusion scheme known as shock ignition (SI) has been proposed, requiring a high intensity spike pulse at the end of a fuel assembly phase to generate a strong shock to ignite the fuel. An initial shock pressure of 0.3 Gbar is required for ignition-scale targets using the SI scheme, requiring a relatively high on-target laser intensity of 5-10X10 15 W/cm 2 for the spike pulse. At such intensities, copious hot electrons can be produced by laser-plasma-instabilities (LPI), e.g., Stimulated Raman Scattering (SRS) and Two-Plasmon Decay (TPD). While very energetic electrons (>200 keV) could preheat the fuel, electrons with moderate energies may actually be beneficial for the SI scheme. Electrons in the 50-100 keV range can be stopped in the compressed high-density outer ablator layer leading to an increase in the ignitor shock strength and therefore enhancing overall efficiency in the SI scheme. Considering this importance of total energy and temperature of hot electrons, it is necessary to understand the LPI in the SI high intensity regime. Characterizing the hot electron source and energy coupling is key to investigating the viability of the SI concept. The overall goal of the HEDLP award was to perform a detailed study of the scaling of hot electron generation and energy coupling on high power laser systems, with intensity, wavelength, and target ablator material relevant to the nonlinear laser-plasma interaction at SI relevant conditions. This was a collaborative project between the Center for Energy Research at the University of California, San Diego (UCSD) and General Atomics. The experiment was performed at the Omega Laser Facility at the Laboratory for Laser Energetics (LLE) in the University of Rochester. Specific objectives of the work were to: understand the basic physics of laser-plasma interactions and instabilities at high laser intensities (up to 10 17 W/cm 2 ) and the effects of low-Z ablator materials and laser wavelengths (IR pulse at 1.054 µm versus UV pulse at 0.351 µm) and intensity scaling, fully characterize the resultant hot electron energy distribution, validate hot electron energy deposition via collisional and kinetic processes in the target and the induced shocks in support of electron-assisted SI concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using a TE011 Cavity as a Magnetic Momentum Monitor

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam constrained in a pair of long solenoids. The high current cooling electron beam needs to be generated in a magnetized electron source, and the beam's magnetization needs to be maintained during the acceleration and transport to the cooling channel. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we present the mechanism and scaling law of this device, as well as the design and preliminary test results of the prototype cavity.

Guo, Jiquan↗

The multiple applications of electrons in space

An electron source such as a simple cathode is a cheap and light device which can serve several technological and scientific purposes in space: (1) electrostatic charging of a spacecraft can be limited by releasing electrons accumulated on the conductive elements of their surface; (2) the erosion of conductive coatings and the ability of conductive paints to withstand the space environment can be evaluated by monitoring the flow of charged particles impinging on their surface; (3) measuring the current collected by the spacecraft surface as a function of its potential with respect to an emitter is a very sensitive diagnostic technique which can yield a number of plasma parameters, such as density and temperature; (4) it is possible to convert the thermal motion of space plasmas into electrical energy by collecting energetic electrons and returning them to the medium as cold particles; (5) a wave in a plasma is characterized by a conduction current density which gives rise to fluctuations of the current flowing to the surface.

Grard, R. J. L.↗

Effects of secondary electron emission on charging

Laboratory charging studies using two electron sources with different energies show that the charging behaviors of typical spacecraft thermal control dielectric surface are extremely sensitive to the shape of their secondary emission curves. The results also suggest that the electron spectrum in a natural charging environment can be separated into three distinct regions (noninteracting, discharging, and charging) depending on the kinetic energy of the incident electron relative to the charged surface, and on the secondary emission characteristics of the material. To a first order approximation, the relative number of electrons in these different regions determines the potential of the charged surface. Detailed measurements of the secondary electron emission characteristics of Kapton, the effects of bulk conductivity and secondary emission on surface charging of these materials is reported.

Leung, M. S.↗

Quantum efficiency enhancement in simulated nanostructured negative electron affinity GaAs photocathodes

We report nanostructured negative electron affinity GaAs photocathodes for a polarized electron source are studied using finite difference time domain optical simulation. The structures studied are nanosquare columns, truncated nanocones, and truncated nanopyramids. Mie-type resonances in the 700–800 nm waveband, suitable for generation of polarized electrons, are identified. At resonance wavelengths, the nanostructures can absorb up to 99% of the incident light. For nanosquare columns and truncated nanocones, the maximum quantum efficiency (QE) at 780 nm obtained from simulation is 27%, whereas for simulated nanopyramids, the QE is ~21%. The high photocathode quantum efficiency is due to the shift of Mie resonance toward the longer wavelength, leading to increased light absorption. The field profile distribution shows the excitation of dipole and quadrupole modes within the nanostructures at resonant frequencies. This leads to enhanced photoabsorption and photoelectron generation closer to emission surfaces than for a flat photocathode. The enhanced photoabsorption and reduced electron transport distance for the nanostructured photocathode enhance its QE compared to that for the flat surface wafer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

‘Universal Injector’ at LERF - Layout and Optics Architecture

Here, we present a next level design of a compact injector within the LERF vault, which would serve both the 22 GeV CEBAF and the positron program, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three C-75 cryo-modules, five isochronous return arcs and three straight sections, facilitating electron beam acceleration up to 650 MeV. The Universal Injector offers flexibility of extraction 1-pass and 2-pass energy electrons, as needed for positron production, with a final 3-pass extraction required by the 650 MeV injector for 22 GeV CEBAF. This note provides an overview of the baseline optics design of the Universal Injector complex, including the 8 MeV injector merger and the recirculator racetrack, including individual extraction lines for all three passes. A comprehensive suite of beam dynamics studies to validate the design is under way; starting with the orbit correction scheme, followed by start-to-end tracking with lattice misalignments and magnet errors.

Bogacz, Alex [Thomas Jefferson National Accelerato↗

Charge Breeding of Radioactive Isotopes at the CARIBU Facility

An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne National Laboratory as part of the californium rare ion breeder upgrade. For the past year, the EBIS-CB has been undergoing commissioning as part of the ATLAS accelerator complex. It has delivered both stable and radioactive beams with A/Q < 6, breeding times < 30 ms, low background contamination, and charge breeding efficiencies > 18% into a single charge state. The operation of this device, challenges during the commissioning phase, and future improvements will be discussed. Published by AIP Publishing.

Vondrasek, Richard↗