Machine learning modeling and model predictive control of a closed-circuit reverse osmosis system

Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.

Desalination↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Annual Industrial Locomotive Energy Consumption in the United States

While US Class 1 railroad locomotive rosters and annual fuel consumption are well-documented, considerably less is known regarding the overall energy consumption of operations involving industrial locomotives. To determine the energy savings potential of this rail operating sector, the objective of this research is to develop an inventory of US industrial locomotives and a baseline estimate of their annual energy consumption. Creating an industrial locomotives roster from public data is challenging given their diverse ownership by shippers or leasing companies, and operating locales largely out of public view. By cross-referencing public data on locomotive reporting marks, serial numbers, online images and aerial images, the project team confirmed the age, model and horsepower of over one thousand industrial locomotives. Estimating energy consumption is complicated by the variability in industrial locomotive types and power ratings, and extreme differences in duty cycles and utilization. Given these limitations, using quantified case study examples and adjustments to standard EPA line-haul and switching duty cycles, bounds on the magnitude of annual US industrial locomotive energy consumption were estimated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characteristics and mathematical modeling of apple slice drying in an electrohydrodynamic system with a needle‐plate electrode

Abstract The drying of apple slices in an electrohydrodynamic (EHD) system with a needle‐plate electrode was characterized and mathematically modeled at voltages of 30, 40, and 50 kV and with distances between needles of 5, 6, and 7 cm. The results showed that the drying rate, effective water diffusion coefficient, and rehydration ratio of the apple slices, and specific energy consumption of drying, all increased with increasing voltage. Initially, there was a period when the drying rate was approximately constant in the low‐voltage EHD, but not in the high voltage conditions. At the same voltage, the drying rate was highest when the distance between needles was 6 cm. The voltage and distance between needles had a significant ( p < .05) interactive effect on the effective water diffusion coefficient and specific energy consumption, but not on the rehydration ratio. General mathematical models for drying can be used to represent the drying behavior of apple slices. The Midilli and Kucuk model and the Logarithmic model had the best fits, with correlation coefficients of 0.998803 and 0.998267, respectively. Predictive functions for the moisture ratio of apple slices based on voltage and distance between needles were established and verified. The results indicated that the Logarithmic model could more accurately predict the moisture ratio of apple slices dried using the EHD method. Practical Applications As a new drying technology, electrohydrodynamic (EHD) drying has unequaled advantages. According to the results, using the appropriate voltage and distance between needles improves not only drying efficiency, but also the rehydration ratio of apple slices, which reflects the quality of dried products. The Logarithmic model can accurately predict the EHD drying behavior of apple slices, which is of great significance in optimizing actual production.

Li, Bowen↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units With Exhaust Air Energy Recovery

This technical report documents the Advanced Rooftop Unit Control End Use Savings Shapes (EUSS) measure, including providing a description of the technology, modeling methods, and the energy savings calculated from applying the measure to applicable across the US commercial building stock using ComStock to quantify its potential. This measure replaces gas furnace and electric resistance rooftop units with high-efficiency variable speed heat pump rooftop units (HP-RTU) that include exhaust air heat or energy recovery. The measure uses the same assumptions and technology as the variable speed HP-RTU measure from EUSS 2023 release 1 but adds energy recovery to precondition outdoor ventilation air to reduce HVAC loads. The HP-RTU compressor lockout temperature is modeled as 0 degrees Fahrenheit; below this temperature, the heat pump is set to shut off. The unit is sized based on the design cooling loads, with backup electric resistance heating addressing any remaining loads including heating hours below the compressor lockout temperature when there is no heat pump heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Model Building Energy Codes – Interim Update

The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates state and national impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, assessed the prospective impacts of national model building energy codes from 2010 through 2040. The model codes of interest in this report are the International Energy Conservation Code (IECC) for residential buildings and ASHRAE Standard 90.1 for commercial buildings. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions at the state and national levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculating Average Hot Water Mixes of Residential Plumbing Fittings Using the ANSI 301-2019 Hot Water Draw Model and National Residential Data to Estimate Hot Water Use in Showerheads and Lavatory Faucets

Available studies of hot water use percentages may not necessarily be generalized to a national level given regional differences, varying methodological approaches, and limited sample sizes. While some publicly available usage data, reports, and surveys estimate actual household usage, a lack of water use data specific to end uses make more precise savings calculations difficult. Additionally, most hot water draw models tend to focus on overall household use and may not readily estimate lavatory fixture use. However, reviewing more recent studies and standards enables the U.S. Environmental Protection Agency’s WaterSense program to update its estimates for hot water use and consumers’ corresponding energy and monetary savings to better reflect realworld conditions. This report specifically focuses on improving hot water use and savings estimates of lavatory faucets and showerheads. To estimate the hot water use of lavatory faucets and showerheads, we employed the 2015 Residential Energy Consumption Surveys (RECS) microdata alongside the ANSI 301-2019 Hot Water Draw Model. These estimates account for regional differences in hot water use, including regional cold water inlet temperatures. As a result, the refinements presented in this report are more robust, more recent, and better describe the geographic variation than previous inputs used by the WaterSense program. In addition, the approach described in this paper can be updated over time or tailored to regionally specific needs given available inputs. We conclude that hot water percentages for showers and faucets calculated using publicly available national data are close to the percentages found by regional studies and are consistent with household-level models of water use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water desalination through the dewpoint evaporative system

This paper presents the first numerical analysis of a novel Dew Point Desalination unit (DPD), which utilizes the phenomenon of the evaporative cooling process to minimize energy consumption. The proposed solution is based on a modular structure, which allows it to obtain any required water production capacity. The analyses for various operational parameters and various climatic conditions are based on the numerical simulations conducted using a validated mathematical model. The system performance was described with different factors, including specific energy consumption (SEC) and daily water production rate respected to 1 m^3*s^-1 of passing air stream (DWP). It is shown that the DPD system can operate in almost every climate zone, and the desalinated water production consumes less than 1.5 kWh*m^-3 of electric energy It is noted the best performance of the DPD system is achieved in the semi-arid, desert and subtropical climate zones. In these climate zones, the 2-stage DPD system allows the production of desalinated water with an electric energy consumption SEC lower than 0.5 kWh*m^-3. The additional benefit of the DPD system is its modularity. The presented DPD system stands as a module, that can be multiplied as needed to achieve the desired size of the desalination plant.

Desalination↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Efficient Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Efficient Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗